Determination of Trace Germanium in Marine Sediments by Hydride Generation-Atomic Fluorescence Spectrometry (HG-AFS) 被引量:2
1
作者 LIJing ZHAOShilan +1 位作者 ZHANGZhaohui ZENGXianjie 《Journal of Ocean University of China》 SCIE CAS 2004年第2期179-182,共4页
A method for the analysis of trace germanium in marine sediments by HG-AFS has been investigated. The experimental conditions such as the acidity of reduction reaction, the amount of sodium boro-hydride, the carrier g... A method for the analysis of trace germanium in marine sediments by HG-AFS has been investigated. The experimental conditions such as the acidity of reduction reaction, the amount of sodium boro-hydride, the carrier gas flow rate, etc., were tested and optimized by using a kind of orthogonal design. The detection limit of the presented method is 0.95 μg L -1 for germanium. The calibration curve shows a satisfactory line in the concentration range 0-320 μg L -1 Ge with a variation coefficient of ±2.1%. 展开更多
关键词 hydride generation-atomic fluorescence spectrometry (HG-AFS) GERMANIUM marine sediment TRACE
下载PDF
Determination of Selenium in Marine Aquatic Products by Hydride Generation-atomic Fluorescence Spectrometry (HG-AFS)
2
作者 ZHANG Zhaohui GAO Xin +1 位作者 Tashiro Yuri Hiroo Ogawa 《Journal of Ocean University of China》 SCIE CAS 2005年第3期252-256,共5页
A method for the analysis of selenium in marine aquatic products by HG-AFS has been investigated. The method is based on the reduction of inorganic selenium to volatile SeH2 which is bubbled out by carrier gas of pure... A method for the analysis of selenium in marine aquatic products by HG-AFS has been investigated. The method is based on the reduction of inorganic selenium to volatile SeH2 which is bubbled out by carrier gas of pure argon, and then swept to Ar-H2 flame quarts atomizer to measure its fluorescence intensity. The hydride generation, transportation, atomization and some instrumental parameters were studied by a kind of orthogonal design. The optimum conditions selected are as follows: reactive acidity, 20% HC1; the amount of NaBH4, 4.9mL; gas flow of argon, 600mLmin^-1; atomizing temperature, 200 ℃ ; negative high voltage, - 300V; light current, 100 mA; integral time, 7s. The detection limit of the presented method is 0.072μgL^-1 for selenium. The calibration curve shows a satisfactory line inthe concentration range from 0.000 to 1.000μgL^-1 Se. The recovery is 95.8%-102.2%. 展开更多
关键词 hydride generation-atomic fluorescence spectrometry(HG-AFS) SELENIUM marine aquatic products
下载PDF
Microwave Digestion Sample Hydride Generation-Atomic Fluorescence Spectrometry Determines Trace Selenium of Mogroside
3
作者 Xiujing Zhang 《International Journal of Technology Management》 2013年第7期128-130,共3页
0.2000g mogroside sample is digested by 7.0ml nitric acid and 3.0ml hydrogen peroxide, and generated by coprecipitation enrichment hydride - atomic fluorescence spectrometry determines trace selenium in it. Under opti... 0.2000g mogroside sample is digested by 7.0ml nitric acid and 3.0ml hydrogen peroxide, and generated by coprecipitation enrichment hydride - atomic fluorescence spectrometry determines trace selenium in it. Under optimum experiment conditions, a standard curve was produced using selenium standard solution, the linear equation is Ise=2890.6c+0.0012,compared wish the linear relaticnship is not by coprecipitation direct determination of standard series Ise=82.56c+0.0018 Selenium detection sensitivity was increased by 35.01 times,the correlation coefficient of obtained linear regression equation is 0.9996, the detection limit is 0.0012~tg/L and the relative standard deviation is 0.76% (n=5). Containing 0.1808pg.g-1 Se Luo Han Shen samples. Based on mogroside sample, add a certain of standard solution to do recovery experiment, the obtained recovery rate is in 95.8%-103.6% and the result is satisfactory. 展开更多
关键词 Hydride generation-atomic fluorescence spectrometry MOGROSIDE SELENIUM
下载PDF
碱性体系-蒸汽发生-原子荧光光谱法测定地质样品中的锌 被引量:4
4
作者 朱园园 宋虎跃 +1 位作者 邱海鸥 汤志勇 《岩矿测试》 CAS CSCD 北大核心 2010年第6期691-694,共4页
研究了原子荧光光谱法测定锌的新体系,针对基体较为复杂的样品,建立了碱性体系-蒸汽发生-原子荧光光谱法测定锌的方法。优化了碱性体系锌蒸汽发生的实验条件及仪器测定的参数,加入镍离子作增敏剂,增强了荧光信号,方法检出限为0.24μg/L... 研究了原子荧光光谱法测定锌的新体系,针对基体较为复杂的样品,建立了碱性体系-蒸汽发生-原子荧光光谱法测定锌的方法。优化了碱性体系锌蒸汽发生的实验条件及仪器测定的参数,加入镍离子作增敏剂,增强了荧光信号,方法检出限为0.24μg/L,精密度RSD(n=6)小于4.0%,锌的标准曲线线性范围为0.5-800.0μg/L。与传统的酸性体系相比,碱性体系具有更高的灵敏度和更宽的线性范围,并且可以大幅度降低共存元素的干扰。方法应用于国家一级标准物质中锌的分析,测定值与标准值基本吻合,加标回收率为94.1%-101.2%。 展开更多
关键词 碱性体系 蒸汽发生-原子荧光光谱法 地质样品
下载PDF