To investigate the seismic performance of a composite frame comprised of steel reinforced ultra high-strength concrete (SRUHSC) columns and steel reinforced concrete (SRC) beams, six interior frame joint specimens...To investigate the seismic performance of a composite frame comprised of steel reinforced ultra high-strength concrete (SRUHSC) columns and steel reinforced concrete (SRC) beams, six interior frame joint specimens were designed and tested under low cyclically lateral load. The effects of the axial load ratio and volumetric stirrup ratio were studied on the characteristics of the frame joint performance including crack pattern, failure mode, ductility, energy dissipation capacity, strength degradation and rigidity degradation. It was found that all joint specimens behaved in a ductile manner with flexural-shear failure in the joint core region while plastic hinges appeared at the beam ends. The ductility and energy absorption capacity of joints increased as the axial load ratio decreased and the volumetric stirIup ratio increased. The displacement ductility coefficient and equivalent damping coefficient of the joints fell between the corresponding coefficients of the steel reinforced concrete (SRC) frame joint and RC frame joint. The axial load ratio and volumetric stirrup ratio have less influence on the strength degradation and more influence on the stiffness degradation. The stiffness of the joint degrades more significantly for a low volumetric stirrup ratio and high axial load ratio. The characteristics obtained from the SRUHSC composite frame joint specimens with better seismic performance may be a useful reference in future engineering applications.展开更多
A beam-column joint of precast and partial steel reinforced concrete( PPSRC) is proposed for precast reinforced concrete frames. The PPSRC consists of partial steel and reinforced concrete. The partial steel is locate...A beam-column joint of precast and partial steel reinforced concrete( PPSRC) is proposed for precast reinforced concrete frames. The PPSRC consists of partial steel and reinforced concrete. The partial steel is located in the core joint region and the connections between concrete members. This paper presents an experimental study of a series of PPSRC specimens. These specimens are tested under low cyclic loading.Experimental results demonstrate that the bearing capacity of the PPSRC specimens is 3 times that of the ordinary reinforced concrete( RC) beam-column joints. The strength and stiffness degradation rates are slower compared with that of the RC beam-column joints. In addition,the strength of the core joint region and the connections is higher than other parts of the PPSRC specimens. Beam failure occurs firstly for the PPSRC specimens,followed by column failure and connections failure. The failure of the core joint region occurs finally.Test results show that the seismic performance of the PPSRC is better than that of the ordinary RC beam-column joints.展开更多
In this paper stresses at joints forming by hollow steel tube and concrete filled steel tube (CFST) are calculated, analyzed and compared. It is founded that the stress concentration at joints of CFST is a quite dif...In this paper stresses at joints forming by hollow steel tube and concrete filled steel tube (CFST) are calculated, analyzed and compared. It is founded that the stress concentration at joints of CFST is a quite different from that of hollow steel tube. A conclusion can be made that analysis of fatigue at the joints of CFST truss arch bridge can not apply the results developed from analyzing at joints of hollow steel tube in marine structure.展开更多
The authors show the results of a study conducted on a joint connecting a concrete column to a composite steel concrete floor,subjected to tension on the beams as a result of the decomposition of sagging bending momen...The authors show the results of a study conducted on a joint connecting a concrete column to a composite steel concrete floor,subjected to tension on the beams as a result of the decomposition of sagging bending moment.The beam to column connection is achieved by means of headed studs welded to the beam and embedded in the concrete cast.Five different configurations have been tested at failure and the results are compared to formulae proposed in literature.Different degrees of ductility,reliability and strength have been obtained varying geometry and reinforcement ratio on the joints tested.展开更多
A new type of semi-rigid thin-walled steel-concrete composite beam-to-column joint has been proposed in this paper.Five semi-rigid composite beam-to-column joint specimens subjected to hogging moments under monotonic ...A new type of semi-rigid thin-walled steel-concrete composite beam-to-column joint has been proposed in this paper.Five semi-rigid composite beam-to-column joint specimens subjected to hogging moments under monotonic loading were tested to study the static behavior of this new type of joint.The main variable parameters for the five joint specimens were the longitudinal reinforcement ratio and the joint type.The experimental results designated that the magnitude of extension of the longitudinal reinforcement is the most important factor that influenced the moment-rotation characteristic of the new type of joint.The concrete slabs could resist 3.8%-19.1% of the total shear load applied to the cross-sections near the beam-to-column connection.The edge stiffened elements,such as the flange of the lipped I-section thin-walled steel beam,were capable of having considerable inelastic deformation capacity although they had comparatively large width-to-thickness ratios.The shear failure of the concrete cantilever edge strip must be taken into account in practical design because it has significant influence on the anchorage of the longitudinal reinforcement in the new type of external joints.展开更多
结合钢筋混凝土结构和钢结构的优势,设计一种型钢-螺栓-后浇混凝土装配式剪力墙型钢混合连接。基于ABAQUS有限元软件建立混合连接的剪力墙模型,探究低周往复荷载作用下该混合连接预制剪力墙的受力性能,主要分析模型的破坏形态、受力机...结合钢筋混凝土结构和钢结构的优势,设计一种型钢-螺栓-后浇混凝土装配式剪力墙型钢混合连接。基于ABAQUS有限元软件建立混合连接的剪力墙模型,探究低周往复荷载作用下该混合连接预制剪力墙的受力性能,主要分析模型的破坏形态、受力机制、变形曲线、特征承载力等,并扩展分析了材料强度、轴压比、连接件数量、型钢截面高度等参数对模型受力性能影响。结果表明:装配式剪力墙破坏形态为压弯破坏,破坏时钢连接件仍保持完整,符合“强连接,弱墙肢”的基本设计理念;装配式剪力墙具有较好的承载力、延性和刚度;轴压比对结构承载力影响显著,型钢混合连接间距的增大能有效提升剪力墙延性。建立了型钢混合连接抗剪需求承载力计算模型和公式,并与国内外规范计算值对比分析,公式计算值和BS EN 1992欧洲规范计算值分别与模拟值的误差在15%和20%以内,均可用于型钢混合连接剪力墙竖缝受剪承载力设计参考。展开更多
基金National Natural Science Foundation of China Under Grant No.50878037
文摘To investigate the seismic performance of a composite frame comprised of steel reinforced ultra high-strength concrete (SRUHSC) columns and steel reinforced concrete (SRC) beams, six interior frame joint specimens were designed and tested under low cyclically lateral load. The effects of the axial load ratio and volumetric stirrup ratio were studied on the characteristics of the frame joint performance including crack pattern, failure mode, ductility, energy dissipation capacity, strength degradation and rigidity degradation. It was found that all joint specimens behaved in a ductile manner with flexural-shear failure in the joint core region while plastic hinges appeared at the beam ends. The ductility and energy absorption capacity of joints increased as the axial load ratio decreased and the volumetric stirIup ratio increased. The displacement ductility coefficient and equivalent damping coefficient of the joints fell between the corresponding coefficients of the steel reinforced concrete (SRC) frame joint and RC frame joint. The axial load ratio and volumetric stirrup ratio have less influence on the strength degradation and more influence on the stiffness degradation. The stiffness of the joint degrades more significantly for a low volumetric stirrup ratio and high axial load ratio. The characteristics obtained from the SRUHSC composite frame joint specimens with better seismic performance may be a useful reference in future engineering applications.
文摘A beam-column joint of precast and partial steel reinforced concrete( PPSRC) is proposed for precast reinforced concrete frames. The PPSRC consists of partial steel and reinforced concrete. The partial steel is located in the core joint region and the connections between concrete members. This paper presents an experimental study of a series of PPSRC specimens. These specimens are tested under low cyclic loading.Experimental results demonstrate that the bearing capacity of the PPSRC specimens is 3 times that of the ordinary reinforced concrete( RC) beam-column joints. The strength and stiffness degradation rates are slower compared with that of the RC beam-column joints. In addition,the strength of the core joint region and the connections is higher than other parts of the PPSRC specimens. Beam failure occurs firstly for the PPSRC specimens,followed by column failure and connections failure. The failure of the core joint region occurs finally.Test results show that the seismic performance of the PPSRC is better than that of the ordinary RC beam-column joints.
文摘In this paper stresses at joints forming by hollow steel tube and concrete filled steel tube (CFST) are calculated, analyzed and compared. It is founded that the stress concentration at joints of CFST is a quite different from that of hollow steel tube. A conclusion can be made that analysis of fatigue at the joints of CFST truss arch bridge can not apply the results developed from analyzing at joints of hollow steel tube in marine structure.
文摘The authors show the results of a study conducted on a joint connecting a concrete column to a composite steel concrete floor,subjected to tension on the beams as a result of the decomposition of sagging bending moment.The beam to column connection is achieved by means of headed studs welded to the beam and embedded in the concrete cast.Five different configurations have been tested at failure and the results are compared to formulae proposed in literature.Different degrees of ductility,reliability and strength have been obtained varying geometry and reinforcement ratio on the joints tested.
基金Sponsored by the National Natural Science Foundation of China (Grant No.50478027)
文摘A new type of semi-rigid thin-walled steel-concrete composite beam-to-column joint has been proposed in this paper.Five semi-rigid composite beam-to-column joint specimens subjected to hogging moments under monotonic loading were tested to study the static behavior of this new type of joint.The main variable parameters for the five joint specimens were the longitudinal reinforcement ratio and the joint type.The experimental results designated that the magnitude of extension of the longitudinal reinforcement is the most important factor that influenced the moment-rotation characteristic of the new type of joint.The concrete slabs could resist 3.8%-19.1% of the total shear load applied to the cross-sections near the beam-to-column connection.The edge stiffened elements,such as the flange of the lipped I-section thin-walled steel beam,were capable of having considerable inelastic deformation capacity although they had comparatively large width-to-thickness ratios.The shear failure of the concrete cantilever edge strip must be taken into account in practical design because it has significant influence on the anchorage of the longitudinal reinforcement in the new type of external joints.
文摘结合钢筋混凝土结构和钢结构的优势,设计一种型钢-螺栓-后浇混凝土装配式剪力墙型钢混合连接。基于ABAQUS有限元软件建立混合连接的剪力墙模型,探究低周往复荷载作用下该混合连接预制剪力墙的受力性能,主要分析模型的破坏形态、受力机制、变形曲线、特征承载力等,并扩展分析了材料强度、轴压比、连接件数量、型钢截面高度等参数对模型受力性能影响。结果表明:装配式剪力墙破坏形态为压弯破坏,破坏时钢连接件仍保持完整,符合“强连接,弱墙肢”的基本设计理念;装配式剪力墙具有较好的承载力、延性和刚度;轴压比对结构承载力影响显著,型钢混合连接间距的增大能有效提升剪力墙延性。建立了型钢混合连接抗剪需求承载力计算模型和公式,并与国内外规范计算值对比分析,公式计算值和BS EN 1992欧洲规范计算值分别与模拟值的误差在15%和20%以内,均可用于型钢混合连接剪力墙竖缝受剪承载力设计参考。