期刊文献+
共找到1,946篇文章
< 1 2 98 >
每页显示 20 50 100
Internal Force Distribution in Steel-Concrete Composite Structure for Pylon of Cable-Stayed Bridge 被引量:5
1
作者 蒲黔辉 白光亮 《Journal of Southwest Jiaotong University(English Edition)》 2009年第2期95-101,共7页
Adopting a steel-anchor beam and steel corbel composite structure in the anchor zone on pylon is one of the key techniques for the design of Jintang bridge, a cable-stayed bridge in Zhoushan, China. In order to ensure... Adopting a steel-anchor beam and steel corbel composite structure in the anchor zone on pylon is one of the key techniques for the design of Jintang bridge, a cable-stayed bridge in Zhoushan, China. In order to ensure the safety of the steel-concrete composite structure, a stud connector model for the joint section was put forward. Experiments were conducted to obtain the relation between load and slip of specimen, the failure pattern of stud connector, the yield bearing capacity and ultimate bearing capacity of a single stud, etc. The whole process of the structural behavior of the specimen was comprehensively analyzed. The features of the internal force distribution in the steel-concrete composite structure and the strain distribution of stud connector under different loads were emphatically studied. The test results show that the stud connector is applicable for the steel-concrete composite structure for pylon of Jintang bridge. The stud has a good ductility performance and a obvious yield process before its destruction. The stud connector basically works in a state of elasticity under a load less than the yield load. 展开更多
关键词 Stud connector Experimental research steel-concrete composite structure Cable-stayed bridge Internal force distribution
下载PDF
Experimental research on mechanical properties of prestressed truss concrete composite beam encased with circular steel tube 被引量:3
2
作者 张博一 郑文忠 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2009年第3期338-345,共8页
Tests of 4 simply supported unbonded prestressed truss concrete composite beams encased with circular steel tube were carried out. It is found that the ratio of the stress increment of the unbonded tendon to that of t... Tests of 4 simply supported unbonded prestressed truss concrete composite beams encased with circular steel tube were carried out. It is found that the ratio of the stress increment of the unbonded tendon to that of the tensile steel tube is 0.252 during the using stage,and the average crack space of beams depends on the ratio of the sum of the bottom chord steel tube's outside diameter and the secondary bottom chord steel tube's section area to the effective tensile concrete area. The coefficient of uneven crack distribution is 1.68 and the formula for the calculation of crack width is established. Test results indicate that the ultimate stress increment of unbonded tendon in the beams decreases in linearity with the increase of the composite reinforcement index β0. The pure bending region of beams accords with the plane section assumption from loading to failure. The calculation formula of ultimate stress increment of the unbonded tendon and the method to calculate the bearing capacity of normal section of beams have been presented. Besides,the method to calculate the stiffness of this sort of beams is brought forward as well. 展开更多
关键词 truss concrete composite beam encased with circular steel tube bearing capacity of normal section STIFFNESS crack width unbonded prestressed tendon
下载PDF
Bearing capacity of composite columns reinforced by concrete filled steel tube 被引量:1
3
作者 韦建刚 ZHU Pu CHEN Bao-chun 《Journal of Chongqing University》 CAS 2013年第1期27-34,共8页
In this study, nine simplified short composite columns consisting of core CFST (concrete filled steel tube) of different diameters and outer reinforced concrete were constructed to study their compressive performance ... In this study, nine simplified short composite columns consisting of core CFST (concrete filled steel tube) of different diameters and outer reinforced concrete were constructed to study their compressive performance under axial or eccentric compression. The failure mode is characterized by the crush of the outer concrete. The bearing capacity increases at first and then decreases with further increase of the position coefficient. It can be concluded that position coefficient is an important structural parameter that has considerable influences on the ultimate bearing capacity of the composite columns. The outer concrete, steel tubes and longitudinal reinforcement are found to work in a cooperative manner under axial or eccentric compression when the position coefficient is about 0.5. An improved bearing capacity algorithm that takes the position coefficient into account has been proposed based on the experimental and simulation results and current technical specification in China. It has been proven to be precise and safe. 展开更多
关键词 concrete filled steel tube composite column position factor TEST FORMULA
下载PDF
Study on Interface mechanical behavior of steel tube reinforced concrete composite pile
4
作者 ZHAO Jiehao 《International English Education Research》 2016年第4期93-94,共2页
Currently for the steel tube reinforced concrete composite pile research, although predecessors make a comprehensive research on the composite pile beating performance, design technology, but there are still many prob... Currently for the steel tube reinforced concrete composite pile research, although predecessors make a comprehensive research on the composite pile beating performance, design technology, but there are still many problems have not been solved, such as the steel tube reinforced concrete pile composite interracial force learn performance research is still in the initial stage. In this paper, we mainly discuss the research methods of several interface mechanical properties and propose the possibility of studying the mechanical properties of the steel tube reinforced concrete composite pile by using the principle of ultrasonic speckle. 展开更多
关键词 steel tube reinforced concrete composite pile Interface mechanical properties research methods
下载PDF
Seismic behavior of concrete filled steel tubular arch structures 被引量:4
5
作者 熊峰 Sashi K Kunnath 刘浩吾 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2005年第1期107-115,共9页
Shaking table tests of a 1:10 scale arch model performed to investigate the seismic behavior and resistance of concrete filled steel tubular (CFT) arch structures are described in this paper. The El-Centro record and ... Shaking table tests of a 1:10 scale arch model performed to investigate the seismic behavior and resistance of concrete filled steel tubular (CFT) arch structures are described in this paper. The El-Centro record and Shanghai artificial wave were adopted as the input excitation. The entire test process can be divided into three stages depending on the lateral brace configurations, i.e., fully (five) braced, two braces removed, and all braces removed. A total of 46 tests, starting from the elastic state to failure condition, have been conducted. The natural vibration frequencies, responses of acceleration, displacement and strain were measured. From the test results, it is demonstrated that the CFT arch structures are capable of resisting severe ground motions and that CFT arches offer a credible alternative to reinforced concrete arches, especially in regions of high seismic intensity. 展开更多
关键词 concrete filled steel tube arch structures shaking table test seismic behavior lateral braces
下载PDF
Evaluation of Current Design Practices on Estimation of Axial Capacity of Concrete Encased Steel Composite Stub Columns: A Review
6
作者 Amiya Kumar Samanta Amit Paul 《Journal of Civil Engineering and Architecture》 2013年第9期1080-1091,共12页
This paper presents the design assessment of concrete encased I-sections composite column based approaches given in Eurocode, ACI Code, BS Code and AISC-LRFD. This study includes comparison of various design parameter... This paper presents the design assessment of concrete encased I-sections composite column based approaches given in Eurocode, ACI Code, BS Code and AISC-LRFD. This study includes comparison of various design parameters and evaluation of design strength based on the procedures predicted in the various codes of practices. A practical example has been assumed and calculation has been shown to evaluate their potentiality in understanding in predicting the potentiality of various procedures. The obtained results based on the methods varies widely, because of the different design considerations adopted by the different codes. As such, they have hardly considered the effect of confinement of the concrete due to the presence of longitudinal reinforcements as well as lateral ties. The study has attempted to throw light on critical review and their potentiality in assessing the strength of such concrete encased composite column under purely axial loads. 展开更多
关键词 concrete encased structural steel composite column design philosophy.
下载PDF
Static behavior of semi-rigid thin-walled steel-concrete composite beam-to-column joints with bolted partial-depth flush end plate:experimental study
7
作者 郜京峰 张耀春 +2 位作者 王海明 姚淇誉 金路 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2011年第5期91-102,共12页
A new type of semi-rigid thin-walled steel-concrete composite beam-to-column joint has been proposed in this paper.Five semi-rigid composite beam-to-column joint specimens subjected to hogging moments under monotonic ... A new type of semi-rigid thin-walled steel-concrete composite beam-to-column joint has been proposed in this paper.Five semi-rigid composite beam-to-column joint specimens subjected to hogging moments under monotonic loading were tested to study the static behavior of this new type of joint.The main variable parameters for the five joint specimens were the longitudinal reinforcement ratio and the joint type.The experimental results designated that the magnitude of extension of the longitudinal reinforcement is the most important factor that influenced the moment-rotation characteristic of the new type of joint.The concrete slabs could resist 3.8%-19.1% of the total shear load applied to the cross-sections near the beam-to-column connection.The edge stiffened elements,such as the flange of the lipped I-section thin-walled steel beam,were capable of having considerable inelastic deformation capacity although they had comparatively large width-to-thickness ratios.The shear failure of the concrete cantilever edge strip must be taken into account in practical design because it has significant influence on the anchorage of the longitudinal reinforcement in the new type of external joints. 展开更多
关键词 SEMI-RIGID thin-walled steel-concrete composite structures beam-to-column joints static behavior experimental study
下载PDF
Discrete Numerical Study on Type II Fracture of Partially Detached Concrete Panels in Cold Region
8
作者 Huayi Zhang Maobin Song +2 位作者 Lei Shen Nizar Faisal Alkayem Maosen Cao 《Structural Durability & Health Monitoring》 EI 2025年第1期167-191,共25页
When the upper chord beam of the beam-string structure(BSS)is made of concrete-filled steel tube(CFST),its overall stiffness will change greatly with the construction of concrete placement,which will have an impact on ... When the upper chord beam of the beam-string structure(BSS)is made of concrete-filled steel tube(CFST),its overall stiffness will change greatly with the construction of concrete placement,which will have an impact on the design of the tensioning plans and selection of control measures for the BSS.In order to accurately obtain the bending stiffness of CFST beam and clarify its impact on the mechanical properties of composite BSS during con-struction,the influence of some factors such as height-width ratio,wall thickness of steel tube,elasticity modulus of concrete,and friction coefficient on the bending stiffness are analyzed parametrically by the numerical simula-tion technology based on an actual project.The calculation formula of the equivalent bending stiffness of CFST is also established through mathematical statistical simulation.Then,the equivalent bending stiffness is introduced into the construction and use stages of the composite BSS,respectively,and the mechanical properties such as prestress-tensioning control value,structural deformation,and internal force of key members are comparatively analyzed when adopting two different construction plans.Moreover,the optimal construction plan of concrete placementfirst and then prestress-tensioning is proposed. 展开更多
关键词 Beam-string structure(BSS) concrete-filled steel tube(CFST) bending stiffness timing of concrete placement prestress-tensioning
下载PDF
Ductility and Ultimate Capacity of Concrete-Filled Lattice Rectangular Steel Tube Columns
9
作者 Chengquan Wang Yun Zou +3 位作者 Tianqi Li Jie Ding Xiaoping Feng Tiange Lei 《Structural Durability & Health Monitoring》 EI 2018年第2期99-110,共12页
A kind of concrete-filled lattice rectangular steel tube(CFLRST)column was put forward.The numerical simulation was modeled to analyze the mechanical characteristic of CFLRST column.By comparing the load-deformation c... A kind of concrete-filled lattice rectangular steel tube(CFLRST)column was put forward.The numerical simulation was modeled to analyze the mechanical characteristic of CFLRST column.By comparing the load-deformation curves from the test results,the rationality and reliability of the finite element model has been confirmed,moreover,the change of the section stiffness and stress in the forcing process and the ultimate bearing capacity of the column were analyzed.Based on the model,the comparison of ultimate bearing capacity and ductility between CFLRST column and reinforced concrete(RC)column were also analyzed.The results of the finite element analysis show that the loading process of CFLRST column consists of elastic stage,yield stage and failure stage.The failure modes are mainly strength failure and failure of elastoplastic instability.CFLRST column has higher bearing capacities in comparison with reinforced concrete columns with the same steel ratio.In addition,the stiffness degeneration of CFLRST column is slower than RC column and CFLRST column has good ductility. 展开更多
关键词 steel-concrete composite structure concrete-filled lattice rectangular steel tube column nonlinear finite element ultimate strength DUCTILITY
下载PDF
Analysis and seismic tests of composite shear walls with CFST columns and steel plate deep beams 被引量:1
10
作者 Dong Hongying Cao Wanlin +2 位作者 Wu Haipeng Zhang Jianwei Xu Fangfang 《Earthquake Engineering and Engineering Vibration》 SCIE EI CSCD 2013年第4期609-624,共16页
A composite shear wall concept based on concrete filled steel tube (CFST) columns and steel plate (SP) deep beams is proposed and examined in this study. The new wall is composed of three different energy dissipat... A composite shear wall concept based on concrete filled steel tube (CFST) columns and steel plate (SP) deep beams is proposed and examined in this study. The new wall is composed of three different energy dissipation elements: CFST columns; SP deep beams; and reinforced concrete (RC) strips. The RC strips are intended to allow the core structural elements - the CFST columns and SP deep beams - to work as a single structure to consume energy. Six specimens of different configurations were tested under cyclic loading. The resulting data are analyzed herein. In addition, numerical simulations of the stress and damage processes for each specimen were carried out, and simulations were completed for a range of location and span-height ratio variations for the SP beams. The simulations show good agreement with the test results. The core structure exhibits a ductile yielding mechanism characteristic of strong column-weak beam structures, hysteretic curves are plump and the composite shear wall exhibits several seismic defense lines. The deformation of the shear wall specimens with encased CFST column and SP deep beam design appears to be closer to that of entire shear walls. Establishing optimal design parameters for the configuration of SP deep beams is pivotal to the best seismic behavior of the wall. The new composite shear wall is therefore suitable for use in the seismic design of building structures. 展开更多
关键词 concrete filled steel tube (CFST) column steel plate (SP) deep beam composite shear wall seismic test calculation and analysis
下载PDF
Identification of Connection Flexibility Effects Based on Load Testing of a Steel-Concrete Bridge
11
作者 Czeslaw Machelski Robert Toczkiewicz 《Journal of Civil Engineering and Architecture》 2012年第11期1504-1513,共10页
In the case of composite girders, an effective cooperation of both parts of the section is influenced by deformability of connectors. Limited flexural stiffness of welded studs, used commonly in bridge structures, doe... In the case of composite girders, an effective cooperation of both parts of the section is influenced by deformability of connectors. Limited flexural stiffness of welded studs, used commonly in bridge structures, does not provide full interaction of a steel beam and a concrete slab. This changes strain distribution in cross-sections of a composite girder and results in redistribution of internal forces in steel and concrete element. In the paper partial interaction index defined on the basis of a neutral axis position, which can be used for verification of steel-concrete interaction in real bridge structures rather than in specimens is proposed. The range of the index value changes, obtained during load testing of a typical steel-concrete composite beam bridge, is presented. The investigation was carried out on a motorway viaduct, consisting of two parallel structures. During the testing values of strains in girders under static and quasi-static loads were measured. The readings from the gauges were used to determine the index, characterizing composite action of the girders. Results of bridge testing under movable load, changing position along the bridge span is presented and obtained in-situ influence functions of strains and index values are commented in the paper. 展开更多
关键词 Abstract: In the case of composite girders an effective cooperation of both parts of the section is influenced by deformability of connectors. Limited flexural stiffness of welded studs used commonly in bridge structures does not provide full interaction of a steel beam and a concrete slab. This changes strain distribution in cross-sections of a composite girder and results in redistribution of internal forces in steel and concrete element. In the paper partial interaction index defined on the basis of a neutral axis position which can be used for verification of steel-concrete interaction in real bridge structures rather composite bridge partial interaction
下载PDF
Technological development and engineering applications of novel steel-concrete composite structures 被引量:13
12
作者 Jianguo NIE Jiaji WANG +2 位作者 Shuangke GOU Yaoyu ZHU Jiansheng FAN 《Frontiers of Structural and Civil Engineering》 SCIE EI CSCD 2019年第1期1-14,共14页
In view of China's development trend of green building and building industrialization,based on the emerging requirements of the structural engineering community,the development and proposition of novel resourcesav... In view of China's development trend of green building and building industrialization,based on the emerging requirements of the structural engineering community,the development and proposition of novel resourcesaving high-performance steel-concrete composite structural systems with adequate safety and durability has become a kernel development trend in structural engineering.This paper provides a state of the art review of China's cutting-edge research and technologies in steel-concrete composite structures in recent years,including the building engineering,the bridge engineering and the special engineering.This paper summarizes the technical principles and applications of the long-span bi-directional composite structures,the long-span composite transfer structures,the comprehensive crack control technique based on uplift-restricted and slip-permitted (URSP)connectors,the steel plate concrete composite (SPCC)strengthen technique,and the innovative composite joints.By improving and revising traditional structure types, the comprehensive superiority of steel-concrete composite structures is well elicited.The research results also indicate that the high-performance steel-concrete composite structures have a promising popularizing prospect in the future. 展开更多
关键词 HIGH-PERFORMANCE composite structure bi-directional composite composite transfer uplift-restricted and slip- permitted connectors steel plate concrete composite STRENGTHEN
原文传递
Behavior of eccentrically loaded concrete-filled GFRP tubular short columns
13
作者 王清湘 关宏波 阮冰峰 《Journal of Harbin Institute of Technology(New Series)》 EI CAS 2011年第6期127-132,共6页
The glass fiber reinforced polymer (GFRP) tube is an effective material that can increase the bearing capacity and ductility of concrete.To study the mechanical behavior of this composite structure,twenty-one concrete... The glass fiber reinforced polymer (GFRP) tube is an effective material that can increase the bearing capacity and ductility of concrete.To study the mechanical behavior of this composite structure,twenty-one concrete-filled GFRP tubular short columns were tested under an eccentric load.The principle influencing factors,such as the eccentricity ratio,concrete strength and ratio of longitudinal reinforcement were also studied.In addition,the course of deformation,failure mode,and failure mechanism were analyzed by observing the phenomena and summarizing the data.The test results indicated that the strength and deformation characteristics of core concrete increase as a result of the addition of the GFRP tube.However,the gain in strength due to the addition of the GFRP tube decreases as the ratio of e /d increases.An increase in the longitudinal steel ratio can improve the bearing capacity of the composite short column effectively.Furthermore,the study showed that the constraint effect of the GFRP tube on high-strength concrete is not as effective as that on common concrete.The reason is that the lateral deformation of the high-strength concrete is less than that of the common concrete when the concrete column was tested under the same axial compression ratio. 展开更多
关键词 GFRP tube eccentric loading concrete short column composite structure
下载PDF
Performance of steel bridge deck pavement structure with ultra high performance concrete based on resin bonding 被引量:1
14
作者 Hui ZHANG Zhixiang ZHANG +3 位作者 Peiwei GAO Lei CUI Youqiang PAN Kuan LI 《Frontiers of Structural and Civil Engineering》 SCIE EI CSCD 2021年第4期895-904,共10页
This research investigated a pavement system on steel bridge decks that use epoxy resin(EP)bonded ultra-high performance concrete(UHPC).Through FEM analysis and static and dynamic bending fatigue tests of the composit... This research investigated a pavement system on steel bridge decks that use epoxy resin(EP)bonded ultra-high performance concrete(UHPC).Through FEM analysis and static and dynamic bending fatigue tests of the composite structure,the influences of the interface of the pavement layer,reinforcement,and different paving materials on the structural performance were compared and analyzed.The results show that the resin bonded UHPC pavement structure can reduce the weld strain in the steel plate by about 32%and the relative deflection between ribs by about 52%under standard axial load conditions compared to traditional pavements.The EP bonding layer can nearly double the drawing strength of the pavement interface from 1.3 MPa,and improve the bending resistance of the UHPC structure on steel bridge decks by about 50%;the bending resistance of reinforced UHPC structures is twice that of unreinforced UHPC structure,and the dynamic deflection of the UHPC pavement structure increases exponentially with increasing fatigue load.The fatigue life is about 1.2×10^(7) cycles under a fixed force of 9 kN and a dynamic deflection of 0.35 mm,which meets the requirements for fatigue performance of pavements on steel bridge decks under traffic conditions of large flow and heavy load. 展开更多
关键词 steel bridge deck pavement ultra-high-performance concrete epoxy resin composite structure bending fatigue performance
原文传递
双壁波纹钢管混凝土构件短柱轴压力学性能
15
作者 路博 崔燕 +2 位作者 方勇 王玉银 李豪 《哈尔滨工业大学学报》 EI CAS 北大核心 2025年第1期56-64,共9页
为改善空心钢筋混凝土柱(HRC)的使用与受力性能,提出一种双壁波纹钢管混凝土(CFDCST)构件。本文共进行了4个大尺寸双壁波纹钢管混凝土短柱与2个空心钢筋混凝土短柱的轴压试验,关键试验参数为试件类型与波纹钢管类型。分析构件的破坏模式... 为改善空心钢筋混凝土柱(HRC)的使用与受力性能,提出一种双壁波纹钢管混凝土(CFDCST)构件。本文共进行了4个大尺寸双壁波纹钢管混凝土短柱与2个空心钢筋混凝土短柱的轴压试验,关键试验参数为试件类型与波纹钢管类型。分析构件的破坏模式,对比不同参数下构件的承载力、峰值应变、延性系数等关键力学指标,获得荷载-波纹钢管应变关系曲线以揭示试件的约束机理并验证外波纹钢管类型的影响。试验结果表明:外波纹钢管可为夹层混凝土提供约束作用,且螺旋角越小,外波纹钢管的约束作用越强;内波纹钢管则主要为夹层混凝土内壁提供有效支撑,以保持截面的完整性。名义约束效应系数与空心率相近时,由于咬口滑移影响,大螺旋角双壁波纹钢管混凝土比小螺旋角双壁波纹钢管混凝土的峰值应力、峰值应变与延性系数分别降低15.5%、21.8%与16.7%。在总用钢量相近的情况下,小螺旋角双壁波纹钢管混凝土柱的承载力、峰值应变与延性系数分别比空心钢筋混凝土柱提高10.6%、36.2%与50.0%。基于试验结果,检验了3种典型承载力公式的适用性,并提出了相应设计建议。 展开更多
关键词 组合结构 空心钢筋混凝土 波纹钢管 双壁构件 约束机理
下载PDF
轨道交通钢混组合连续梁及剪力件设计探讨
16
作者 李牧 《价值工程》 2025年第1期71-73,共3页
由于钢混组合梁结构可以充分发挥混凝土和钢结构的性能优势,因此在轨道交通桥梁设计中逐步得到推广。目前对于轨道交通组合梁上部结构构造设计及计算参考较少,不同设计标准、规范针对剪力件的计算仍存在区别,因此有必要对上述问题进行... 由于钢混组合梁结构可以充分发挥混凝土和钢结构的性能优势,因此在轨道交通桥梁设计中逐步得到推广。目前对于轨道交通组合梁上部结构构造设计及计算参考较少,不同设计标准、规范针对剪力件的计算仍存在区别,因此有必要对上述问题进行分析探讨。本文结合国内某轨道交通项目(45+70+45)m钢混组合连续梁的设计,通过有限元软件建模计算,分析钢混组合梁的受力特点,并针对国内外不同规范对于钢混组合梁剪力件的抗剪承载力计算公式进行比较及探讨,以期为同类型桥梁设计计算提供一定参考。 展开更多
关键词 轨道交通桥梁 钢混组合连续梁 剪力连接件 焊钉 结构分析
下载PDF
Seismic behavior of thin-walled circular and stiffened square steel tubed-reinforced-concrete columns 被引量:4
17
作者 GAN Dan ZHOU XuHong +1 位作者 LIU JiePeng LI Jiang 《Science China(Technological Sciences)》 SCIE EI CAS CSCD 2019年第3期511-520,共10页
Steel tubed-reinforced-concrete(TRC) columns have been gradually used in the construction of high-rise buildings recently because of their high axial load-carrying capacities and excellent seismic behavior. Existing s... Steel tubed-reinforced-concrete(TRC) columns have been gradually used in the construction of high-rise buildings recently because of their high axial load-carrying capacities and excellent seismic behavior. Existing studies about their seismic behavior were focused on columns with relatively thick tubes, i.e., diameter-to-thickness/width-to-thickness(D/t) ratios were below 100,while little is known about thin-walled TRC columns, especially for square TRC columns. Considering the infilled concrete of square TRC columns is non-uniformly and non-effectively confined, accordingly, stiffened square TRC columns are usually adopted in practice. Thus, two thin-walled circular TRC columns(D/t=120) and two stiffened square ones with diagonal stiffeners in plastic hinge regions(D/t=106) were tested under a constant axial compression combined with cyclic lateral loading.Both the circular and stiffened square TRC columns had the same cross sectional area, tube thickness, reinforcing bar ratio and column height. Flexural failure occurred for all the four specimens. Test results showed the strengths of the stiffened square TRC columns were a little higher in comparison to their circular counterparts; the ductility and energy dissipation capacities were excellent for both the stiffened and circular TRC columns, indicating very good confinement was gained from the yielded steel tubes of the plastic hinge regions at the peak loads. And shear stresses(35–90 MPa) in the sheared plates showed their moderate contribution of carrying lateral loads. Finally, cross sectional capacity analysis results demonstrated the method for TRC columns is acceptable for the stiffened square TRC columns. 展开更多
关键词 steel tubed-reinforced-concrete COLUMN concrete filled steel tube composite COLUMN cyclic behavior steel JACKET
原文传递
常泰长江大桥组合索塔锚固结构钢-混传剪构造足尺模型试验研究 被引量:3
18
作者 赵灿晖 王康康 +1 位作者 沈孔健 郑清刚 《桥梁建设》 EI CSCD 北大核心 2024年第1期31-38,共8页
常泰长江大桥索塔锚固结构采用钢箱-核芯混凝土组合结构,为研究该新型组合索塔锚固结构钢-混传剪构造的受力特性,进行钢-混传剪构造足尺模型试验研究。制作2个锚固结构足尺节段试验模型,通过压剪试验研究锚固结构的荷载~滑移曲线及应力... 常泰长江大桥索塔锚固结构采用钢箱-核芯混凝土组合结构,为研究该新型组合索塔锚固结构钢-混传剪构造的受力特性,进行钢-混传剪构造足尺模型试验研究。制作2个锚固结构足尺节段试验模型,通过压剪试验研究锚固结构的荷载~滑移曲线及应力、应变分布等受力特性,并通过有限元模型分析锚固结构的传力机理和各组件的内力分配比例,推导剪力钉剪力计算方法。结果表明:在2.14倍单索最大索力荷载作用下,锚固结构保持弹性状态,钢壁板未产生明显滑移,钢-混界面最大滑移不超过0.25 mm,该锚固结构中钢-混传剪构造至少具有2.14倍的安全系数;荷载作用下,剪力钉剪力从上至下逐渐增大,锚腹板附近底部3排剪力钉剪力较大,钢-混传剪构造至少存在剪力钉和界面摩擦力2种传剪机制,钢-混传剪构造的承载能力显著提高;钢-混传剪构造受力过程分为粘结力传力阶段和局部滑移阶段,剪力钉剪力分布不仅与沿剪切方向长度分布有关,也与荷载的大小线性相关。 展开更多
关键词 斜拉桥 组合索塔锚固结构 钢-混传剪构造 荷载~滑移曲线 足尺模型试验 有限元法
下载PDF
装配式轻钢框架-轻钢骨架轻混凝土墙板结构抗震性能 被引量:6
19
作者 曹万林 杨兆源 《北京工业大学学报》 CAS CSCD 北大核心 2024年第2期165-179,共15页
为研究装配式轻钢框架-轻钢骨架轻混凝土墙板结构抗震性能,对1个足尺轻钢框架结构试件和3个足尺轻钢框架-轻钢骨架轻混凝土墙板结构试件进行了低周反复荷载下的抗震性能试验及理论分析,试件变量包括:2种装配构造,即内嵌式装配墙板、外... 为研究装配式轻钢框架-轻钢骨架轻混凝土墙板结构抗震性能,对1个足尺轻钢框架结构试件和3个足尺轻钢框架-轻钢骨架轻混凝土墙板结构试件进行了低周反复荷载下的抗震性能试验及理论分析,试件变量包括:2种装配构造,即内嵌式装配墙板、外贴式装配墙板;2种轻钢骨架轻混凝土墙板,即框架式轻钢骨架轻混凝土墙板、桁架式轻钢骨架轻混凝土墙板。研究了各试件的破坏特征和损伤演化过程,分析了结构滞回特性、承载力、变形能力、刚度退化、耗能性能和应变。结果表明:装配式轻钢框架-轻钢骨架轻混凝土墙板结构共同工作性能良好,其水平承载力相比轻钢框架提高了204.7%~210.4%,抗侧刚度提高了257.3%~512.5%,结构变形及耗能能力有显著提高;内嵌墙板的自攻钉连接构造以及外贴墙板的螺栓连接构造传力性能可靠,结构具备2道抗震防线的受力特征;基于简化塑性分析模型以及拉压杆软化桁架模型,对试件承载力进行了计算,计算结果与试验符合较好。 展开更多
关键词 装配式组合结构 轻钢框架 轻钢骨架轻混凝土墙板 抗震性能 低周反复荷载试验 承载力计算
下载PDF
乌兹别克斯坦9度区某超高层建筑结构设计与优化 被引量:1
20
作者 闫锋 花炳灿 安东亚 《建筑结构》 北大核心 2024年第13期51-56,共6页
对于9度设防地区的超高层建筑,其结构设计基本由地震作用控制,因此抗震设计尤为重要。建筑消能减震技术可在提高结构地震安全储备的同时,降低整体工程造价,是结构优化设计的有效措施。对位于9度区的超高层建筑进行了结构方案选型对比、... 对于9度设防地区的超高层建筑,其结构设计基本由地震作用控制,因此抗震设计尤为重要。建筑消能减震技术可在提高结构地震安全储备的同时,降低整体工程造价,是结构优化设计的有效措施。对位于9度区的超高层建筑进行了结构方案选型对比、结构方案优化、减震设计方案比选、剪力墙内嵌钢板优化。结果显示,钢骨混凝土框架⁃核心筒方案相对于钢框架⁃支撑方案具备更高的成本优势;框架⁃核心筒方案可通过精细化设计作进一步优化;在此基础上,对钢骨混凝土框架⁃核心筒方案采用两种消能减震方案进行比选,结果表明,采用黏滞阻尼器方案的结构抗震性能明显优于采用黏滞阻尼墙方案;最后通过增大剪力墙竖向分布钢筋配筋率,对低区核心筒墙肢中的内嵌钢板进行了优化。 展开更多
关键词 9度抗震设防 超高层建筑 钢骨混凝土结构 框架⁃核心筒 消能减震
下载PDF
上一页 1 2 98 下一页 到第