In order to consider the influence of steel pole on the measurement of wind speed sensors and determinate the installation position of wind speed sensors, the flow field around wind speed sensors was investigated. Bas...In order to consider the influence of steel pole on the measurement of wind speed sensors and determinate the installation position of wind speed sensors, the flow field around wind speed sensors was investigated. Based on the three-dimensional steady Reynolds-averaged Navier-Stokes equations and k-ε double equations turbulent model, the field flow around the wind speed sensor and the steel pole along a high-speed railway was simulated on an unstructured grid. The grid-independent validation was conducted and the accuracy of the present numerical simulation method was validated by experiments and simulations carried out by previous researchers. Results show that the steel pole has a significant influence on the measurement results of wind speed sensors. As the distance between two wind speed sensors is varied from 0.3 to 1.0 m, the impact angles are less than ±20°, it is proposed that the distance between two wind speed sensors is 0.8 m at least, and the interval between wind speed sensors and the steel pole is more than 1.0 m with the sensors located on the upstream side.展开更多
The magnetic property of soft magnetic metals and alloys depends strongly on the crystallo-graphic orientation. In automated equipment for orientation research, the intensity for drawing up the pole figure is measured...The magnetic property of soft magnetic metals and alloys depends strongly on the crystallo-graphic orientation. In automated equipment for orientation research, the intensity for drawing up the pole figure is measured in detail. The present research shows that the accurate pole figure can be drawn up without measuring concretely the intensity. For directional Si steel sheet the measuring step may be 4~5 degrees. In this paper the experimental equation for defo-cusing correction was derived from the experimental data in different specimens with random orientation.展开更多
In the present paper,46 cases of periarthritis of shoulder were treated by needlingthe Jiansanzhen with magnetic pole needle and massage. Among them,43 cases were cured, ac-counting for 93. 48% and 46 were effective. ...In the present paper,46 cases of periarthritis of shoulder were treated by needlingthe Jiansanzhen with magnetic pole needle and massage. Among them,43 cases were cured, ac-counting for 93. 48% and 46 were effective. The total effective rate was 100%. In control groupI there were 23 cases, who received treatment of acupuncture with traditional stainless-steel fili-form needle and massage, the total effective rate was 91. 3%. Comparison of the therapeutic ef-fects between the two groups showed X^2=4. 12, P【0.05. In control group II there were 23 cas-es, who received needling Tiaokou point (ST 38)-through-Chengshan (BL 57) with the abovementioned stainless-steel filiform, one of ancient and modern experimental methods, the total ef-fecive rate was 82. 6%, which was compared with that in the treatment group, indicating X^2=8.492, P【0. 01. It is suggested that the therapeutic effect in the treatment group was superior tothat in the control group I and significantly superior to that in the control group II.展开更多
基金Projects(U1334205,51205418)supported by the National Natural Science Foundation of ChinaProject(2014T002-A)supported by the Science and Technology Research Program of China Railway CorporationProject(132014)supported by the Fok Ying Tong Education Foundation of China
文摘In order to consider the influence of steel pole on the measurement of wind speed sensors and determinate the installation position of wind speed sensors, the flow field around wind speed sensors was investigated. Based on the three-dimensional steady Reynolds-averaged Navier-Stokes equations and k-ε double equations turbulent model, the field flow around the wind speed sensor and the steel pole along a high-speed railway was simulated on an unstructured grid. The grid-independent validation was conducted and the accuracy of the present numerical simulation method was validated by experiments and simulations carried out by previous researchers. Results show that the steel pole has a significant influence on the measurement results of wind speed sensors. As the distance between two wind speed sensors is varied from 0.3 to 1.0 m, the impact angles are less than ±20°, it is proposed that the distance between two wind speed sensors is 0.8 m at least, and the interval between wind speed sensors and the steel pole is more than 1.0 m with the sensors located on the upstream side.
文摘The magnetic property of soft magnetic metals and alloys depends strongly on the crystallo-graphic orientation. In automated equipment for orientation research, the intensity for drawing up the pole figure is measured in detail. The present research shows that the accurate pole figure can be drawn up without measuring concretely the intensity. For directional Si steel sheet the measuring step may be 4~5 degrees. In this paper the experimental equation for defo-cusing correction was derived from the experimental data in different specimens with random orientation.
文摘In the present paper,46 cases of periarthritis of shoulder were treated by needlingthe Jiansanzhen with magnetic pole needle and massage. Among them,43 cases were cured, ac-counting for 93. 48% and 46 were effective. The total effective rate was 100%. In control groupI there were 23 cases, who received treatment of acupuncture with traditional stainless-steel fili-form needle and massage, the total effective rate was 91. 3%. Comparison of the therapeutic ef-fects between the two groups showed X^2=4. 12, P【0.05. In control group II there were 23 cas-es, who received needling Tiaokou point (ST 38)-through-Chengshan (BL 57) with the abovementioned stainless-steel filiform, one of ancient and modern experimental methods, the total ef-fecive rate was 82. 6%, which was compared with that in the treatment group, indicating X^2=8.492, P【0. 01. It is suggested that the therapeutic effect in the treatment group was superior tothat in the control group I and significantly superior to that in the control group II.