This article shows an innovative method to model and validate the hot air flow through the blast furnacés tuyeres. This study will be the basis for flow measurements implementation and safety interlocks for the p...This article shows an innovative method to model and validate the hot air flow through the blast furnacés tuyeres. This study will be the basis for flow measurements implementation and safety interlocks for the pulverized coal injection. The flow measurements were taken in the blast furnace down leg pipes by installing refractory Venturi tubes. The system for the calculation of differential pressure takes into consideration the dimension of the Venturi, the air density and compressibility. The objective is to specify the flow transmitters required to automate a control system and implement safety interlocks for the coal injection plant.展开更多
Objective: Determine the occurrence rate of cochlear implant (CI) electrode tip fold-over and electrode scalar deviation as reported in patient cases with different commercial electrode types. Data-sources: PubMed sea...Objective: Determine the occurrence rate of cochlear implant (CI) electrode tip fold-over and electrode scalar deviation as reported in patient cases with different commercial electrode types. Data-sources: PubMed search for identifying peer-reviewed articles published till 2018 on CI electrode tip fold-over and scalar deviation. Key-words for searching were “Cochlear electrode tip fold-over”,“Cochlear electrode scalar position” and “Cochlear electrode scalar location”. Articles-selection: Only if electrode related issues were investigated in patient cases. 38 articles met the inclusion-criteria. Results: 13 articles on electrode tip fold-over issue covering 3177 implanted ears, out of which 50 ears were identified with electrode tip fold-over with an occurrence rate of 1.57%. Out of 50 ears, 43 were implanted with pre-curved electrodes and the remaining 7 with lateral-wall electrodes. One article reported on both tip fold-over and scalar deviation. 26 articles reported on the electrode scalar deviation covering an overall number of 2046 ears out of which, 458 were identified with electrode scalar deviation at a rate of 22.38%. After removing the studies that did not report on the number of electrodes per electrode type, it was 1324 ears implanted with pre-curved electrode and 507 ears with lateral-wall electrode. Out of 1324 pre-curved electrode implanted ears, 424 were reported with scalar deviation making an occurrence rate of 32%. Out of 507 lateral-wall electrode implanted ears, 43 were associated with scalar deviation at an occurrence rate of 6.7%. Conclusion: This literature review revealing the fact of higher rate of electrode insertion trauma associated with pre-curved electrode type irrespective of CI brand is one step closer to obsolete it from the clinical practice in the interest of patient's cochlear health.展开更多
Pipeline plays an indispensable role in process industries,because the progressing crack-like defects of in it may result in serious accidents and significant economic losses.Therefore,it is essential to detect the cr...Pipeline plays an indispensable role in process industries,because the progressing crack-like defects of in it may result in serious accidents and significant economic losses.Therefore,it is essential to detect the cracks occurred in pipelines.The axial crack-like defects in elbows with different angle are inspected by using the T(0,1)mode guided waves,in which different configurations including 45°,90°,135°and 180°(straight pipe)are considered respectively.Firstly,the detection sensitivity for different defect location is experimentally investigated.After that,finite element simulation is used to explore the propagation behaviors of T(0,1)mode in different bend structures.Simulation and experiment results show that the crack in different areas of the elbow can affect the detection sensitivity.It can be found that the detection sensitivity of crack in the middle area of the elbow is higher compared to the extrados and intrados of the elbow.Finally,the mode conversion is also investigated when the T(0,1)crosses the bend,and the results show that bend is a key factor to the mode conversion phenomenon which presents between the T(0,1)mode and F(1,2)mode.展开更多
A geometric model was built to represent the position relation of a wheeled mobile robot relative to a pipe. The relationship between the deviation of falling off for the robot and the curvature of the pipe was formul...A geometric model was built to represent the position relation of a wheeled mobile robot relative to a pipe. The relationship between the deviation of falling off for the robot and the curvature of the pipe was formulated quantitatively. Based on the relationship, a mathematical model was derived and a fuzzy control algorithm for the robot was developed. Simulations were carried out to confirm the dynamic index and the validity of the mathematical model of the fuzzy control algorithm for seam tracking of pipe welding. Experiments for pipe welding with the mobile robot were also carried out to verify the algorithm, and the results showed that the seam has a good quality with a preferable appearance of weld.展开更多
文摘This article shows an innovative method to model and validate the hot air flow through the blast furnacés tuyeres. This study will be the basis for flow measurements implementation and safety interlocks for the pulverized coal injection. The flow measurements were taken in the blast furnace down leg pipes by installing refractory Venturi tubes. The system for the calculation of differential pressure takes into consideration the dimension of the Venturi, the air density and compressibility. The objective is to specify the flow transmitters required to automate a control system and implement safety interlocks for the coal injection plant.
文摘Objective: Determine the occurrence rate of cochlear implant (CI) electrode tip fold-over and electrode scalar deviation as reported in patient cases with different commercial electrode types. Data-sources: PubMed search for identifying peer-reviewed articles published till 2018 on CI electrode tip fold-over and scalar deviation. Key-words for searching were “Cochlear electrode tip fold-over”,“Cochlear electrode scalar position” and “Cochlear electrode scalar location”. Articles-selection: Only if electrode related issues were investigated in patient cases. 38 articles met the inclusion-criteria. Results: 13 articles on electrode tip fold-over issue covering 3177 implanted ears, out of which 50 ears were identified with electrode tip fold-over with an occurrence rate of 1.57%. Out of 50 ears, 43 were implanted with pre-curved electrodes and the remaining 7 with lateral-wall electrodes. One article reported on both tip fold-over and scalar deviation. 26 articles reported on the electrode scalar deviation covering an overall number of 2046 ears out of which, 458 were identified with electrode scalar deviation at a rate of 22.38%. After removing the studies that did not report on the number of electrodes per electrode type, it was 1324 ears implanted with pre-curved electrode and 507 ears with lateral-wall electrode. Out of 1324 pre-curved electrode implanted ears, 424 were reported with scalar deviation making an occurrence rate of 32%. Out of 507 lateral-wall electrode implanted ears, 43 were associated with scalar deviation at an occurrence rate of 6.7%. Conclusion: This literature review revealing the fact of higher rate of electrode insertion trauma associated with pre-curved electrode type irrespective of CI brand is one step closer to obsolete it from the clinical practice in the interest of patient's cochlear health.
基金supported by the National Natural Science Foundation of China(Nos.51575185,51175178)
文摘Pipeline plays an indispensable role in process industries,because the progressing crack-like defects of in it may result in serious accidents and significant economic losses.Therefore,it is essential to detect the cracks occurred in pipelines.The axial crack-like defects in elbows with different angle are inspected by using the T(0,1)mode guided waves,in which different configurations including 45°,90°,135°and 180°(straight pipe)are considered respectively.Firstly,the detection sensitivity for different defect location is experimentally investigated.After that,finite element simulation is used to explore the propagation behaviors of T(0,1)mode in different bend structures.Simulation and experiment results show that the crack in different areas of the elbow can affect the detection sensitivity.It can be found that the detection sensitivity of crack in the middle area of the elbow is higher compared to the extrados and intrados of the elbow.Finally,the mode conversion is also investigated when the T(0,1)crosses the bend,and the results show that bend is a key factor to the mode conversion phenomenon which presents between the T(0,1)mode and F(1,2)mode.
基金This paper is supported by National Natural Science Foundation of China ( Grant No. 51275051 ), the innovation and improvement plan of Beijing Education Commission (Grant No. TJSHG201510017023 )
文摘A geometric model was built to represent the position relation of a wheeled mobile robot relative to a pipe. The relationship between the deviation of falling off for the robot and the curvature of the pipe was formulated quantitatively. Based on the relationship, a mathematical model was derived and a fuzzy control algorithm for the robot was developed. Simulations were carried out to confirm the dynamic index and the validity of the mathematical model of the fuzzy control algorithm for seam tracking of pipe welding. Experiments for pipe welding with the mobile robot were also carried out to verify the algorithm, and the results showed that the seam has a good quality with a preferable appearance of weld.