Required by the supercritical carbon dioxide(s CO_(2))coal-fired power cycle,s CO_(2)entering a boiler has a high temperature and can cause overheating of tubes.To eliminate the pressure drop penalty effect,the s CO_(...Required by the supercritical carbon dioxide(s CO_(2))coal-fired power cycle,s CO_(2)entering a boiler has a high temperature and can cause overheating of tubes.To eliminate the pressure drop penalty effect,the s CO_(2)boiler consists of several modules,each having different heat flux received from the furnace side(q)and different CO_(2)temperature in the cooling wall tube(T_f).We aim to search for the best matching strategy coupling furnace side and tube side to obtain the lowest temperature of tubes.By theoretically analyzing the wall temperature influenced by q,T_f and a comprehensive thermal resistance C,two matching methods are introduced:the heat flux-temperature matching(HTM)which matches higher q with lower T_f,and the heat flux-heat flux matching(HHM)that matches higher q with higher allowable-heat-flux at the temperature limit of tubes.HTM is a conventional method but HHM is newly proposed here.We show that,if C is identical for different modules,the two methods coincide;otherwise,HHM is recommended.For a s CO_(2)boiler driving 1000 MWe power plant,smaller cooling wall temperatures are obtained by HHM than HTM.Based on HHM,the mid-partition wall,heat transfer enhancement,and downward flow are comprehensively used,decreasing the wall temperature significantly.展开更多
基金support of the National Key R&D Program of China(2017YFB0601801)the National Natural Science Foundation of China(No.51776064)。
文摘Required by the supercritical carbon dioxide(s CO_(2))coal-fired power cycle,s CO_(2)entering a boiler has a high temperature and can cause overheating of tubes.To eliminate the pressure drop penalty effect,the s CO_(2)boiler consists of several modules,each having different heat flux received from the furnace side(q)and different CO_(2)temperature in the cooling wall tube(T_f).We aim to search for the best matching strategy coupling furnace side and tube side to obtain the lowest temperature of tubes.By theoretically analyzing the wall temperature influenced by q,T_f and a comprehensive thermal resistance C,two matching methods are introduced:the heat flux-temperature matching(HTM)which matches higher q with lower T_f,and the heat flux-heat flux matching(HHM)that matches higher q with higher allowable-heat-flux at the temperature limit of tubes.HTM is a conventional method but HHM is newly proposed here.We show that,if C is identical for different modules,the two methods coincide;otherwise,HHM is recommended.For a s CO_(2)boiler driving 1000 MWe power plant,smaller cooling wall temperatures are obtained by HHM than HTM.Based on HHM,the mid-partition wall,heat transfer enhancement,and downward flow are comprehensively used,decreasing the wall temperature significantly.