期刊文献+
共找到2篇文章
< 1 >
每页显示 20 50 100
Effect of time bin size on accuracy of streak tube imaging lidar
1
作者 叶光超 樊荣伟 +3 位作者 陈兆东 徐新瑞 贺平 陈德应 《Chinese Optics Letters》 SCIE EI CAS CSCD 2016年第2期19-22,共4页
Streak tube imaging lidar (STIL) is an active imaging system that has a high range accuracy with tile use of a pulsed lapser transmitter and streak tube receiver to produce 3D range inlages. This work investigates t... Streak tube imaging lidar (STIL) is an active imaging system that has a high range accuracy with tile use of a pulsed lapser transmitter and streak tube receiver to produce 3D range inlages. This work investigates the effect of tile time bin size oil the range accuracy of STIL systems based on the peak detection algorithm. The nunlerical simulation indicates that the time bin size has a significant effect on the range aceuracy, resulting in a modified analytical estimate of the range error. An indoor experilnent with a planar target is carried out to validate the theory that shows the linear relationship between tile range error and the time bin size. Finer 3D depth iinages of a fist model are acquired by using a smaller time bin size and the best range error of 0.003 In is achieved with the optimal time bin size of 0.07 ns. 展开更多
关键词 TIME Effect of time bin size on accuracy of streak tube imaging lidar
原文传递
Depth resolution improvement of streak tube imaging lidar system using three laser beams
2
作者 Zhaodong Chen Rongwei Fan +4 位作者 Guangchao Ye Tong Luo Jiayu Guan Zhigang Zhou Deying Chen 《Chinese Optics Letters》 SCIE EI CAS CSCD 2018年第4期61-65,共5页
The work proposes a three-laser-beam streak tube imaging lidar system. Besides the main measuring laser beam,the second beam is used to decrease the error of time synchronization. The third beam has n+0.5 pixels' di... The work proposes a three-laser-beam streak tube imaging lidar system. Besides the main measuring laser beam,the second beam is used to decrease the error of time synchronization. The third beam has n+0.5 pixels' difference compared to the main measuring beam on a CCD, and it is used to correct the error caused by CCD discrete sampling. A three-dimensional(3D) imaging experiment using this scheme is carried out with time bin size of 0.066 ns(i.e., corresponding to a distance of 9.9 mm). An image of a 3D model is obtained with the depth resolution of 〈2 mm, which corresponds to ~0.2 pixel. 展开更多
关键词 CCD Depth resolution improvement of streak tube imaging lidar system using three laser beams
原文传递
上一页 1 下一页 到第