Lateral deflection formulas are presented for analysis of the strengthened story applied to flame-core structures. For the framecore structures with top outriggers and with middle outriggers, the relationship between ...Lateral deflection formulas are presented for analysis of the strengthened story applied to flame-core structures. For the framecore structures with top outriggers and with middle outriggers, the relationship between stiffness characteristic parameters of frame and outriggers and the top drift of structures under different loads is analyzed. It is indicated that when stiffness characteristic parameter of frame is large, outrigger efficiency for top drift reduction is low, and the mutation of internal forces occurs; when the stiffness characteristic parameter of frame is less than 3, installing the strengthened story is advantageous to frame-core structures.展开更多
基金The Natural Science Foundation of China(No.50708041)
文摘Lateral deflection formulas are presented for analysis of the strengthened story applied to flame-core structures. For the framecore structures with top outriggers and with middle outriggers, the relationship between stiffness characteristic parameters of frame and outriggers and the top drift of structures under different loads is analyzed. It is indicated that when stiffness characteristic parameter of frame is large, outrigger efficiency for top drift reduction is low, and the mutation of internal forces occurs; when the stiffness characteristic parameter of frame is less than 3, installing the strengthened story is advantageous to frame-core structures.