Background The rocking and instability of a loaded complete denture (CD) during lateral excursion reduce the bearing area under the denture base, causing localized high stress concentrations. This can lead to mucosa...Background The rocking and instability of a loaded complete denture (CD) during lateral excursion reduce the bearing area under the denture base, causing localized high stress concentrations. This can lead to mucosal tenderness, ulceration, and alveolar bone resorption, and the linear occlusion design was to decrease the lateral force exerted on the denture and to ensure denture stability. But it is not known how the bearing areas of linear occlusal CDs (LOCDs) and anatomic occlusal CDs (AOCDs) differ. The purpose of this study was to analyze and compare the distributions of the high and low vertical stress-bearing areas in the mandibular alveolar mucosa under LOCDs and AOCDs at lateral excursion.Methods Computerized tomography (CT) and finite element analysis were used to establish three-dimensional models of an edentulous maxilla and mandible with severe residual ridge resorption. These models were composed of maxillary and mandibular bone structure, mucosa, and the LOCD or AOCD. Lateral excursion movements of the mandible were simulated and the vertical stress-bearing areas in the mucosa under both mandibular CDs were analyzed using ANSYS 7.0.Results On the working side, the high stress-bearing (-0.07 to -0.1 Mpa) area under the LOCD during lateral excursion was smaller than that under the AOCD, while the medium stress-bearing (-0.03 to -0.07 Mpa) area under the LOCD was 1.33-fold that under the AOCD. The medium stress-bearing area on the non-working side under the LOCD was 2.4-fold that under the AOCD. Therefore, the overall medium vertical stress-bearing area under the LOCD was 20% larger than that under the AOCD.Conclusions During lateral excursion, the medium vertical stress-bearing area under a mandibular LOCD was larger and the high vertical stress-bearing area was smaller than that under an AOCD. Thus, the vertical stress under the LOCD was distributed more evenly and over a wider area than that under the AOCD, thereby improving denture stability.展开更多
基金This study was supported by a grant from the Beijing Natural Science Foundation, China (No. 3073018).
文摘Background The rocking and instability of a loaded complete denture (CD) during lateral excursion reduce the bearing area under the denture base, causing localized high stress concentrations. This can lead to mucosal tenderness, ulceration, and alveolar bone resorption, and the linear occlusion design was to decrease the lateral force exerted on the denture and to ensure denture stability. But it is not known how the bearing areas of linear occlusal CDs (LOCDs) and anatomic occlusal CDs (AOCDs) differ. The purpose of this study was to analyze and compare the distributions of the high and low vertical stress-bearing areas in the mandibular alveolar mucosa under LOCDs and AOCDs at lateral excursion.Methods Computerized tomography (CT) and finite element analysis were used to establish three-dimensional models of an edentulous maxilla and mandible with severe residual ridge resorption. These models were composed of maxillary and mandibular bone structure, mucosa, and the LOCD or AOCD. Lateral excursion movements of the mandible were simulated and the vertical stress-bearing areas in the mucosa under both mandibular CDs were analyzed using ANSYS 7.0.Results On the working side, the high stress-bearing (-0.07 to -0.1 Mpa) area under the LOCD during lateral excursion was smaller than that under the AOCD, while the medium stress-bearing (-0.03 to -0.07 Mpa) area under the LOCD was 1.33-fold that under the AOCD. The medium stress-bearing area on the non-working side under the LOCD was 2.4-fold that under the AOCD. Therefore, the overall medium vertical stress-bearing area under the LOCD was 20% larger than that under the AOCD.Conclusions During lateral excursion, the medium vertical stress-bearing area under a mandibular LOCD was larger and the high vertical stress-bearing area was smaller than that under an AOCD. Thus, the vertical stress under the LOCD was distributed more evenly and over a wider area than that under the AOCD, thereby improving denture stability.