Series compensation has proven to increase stability in transmission of electric power. On the other hand insertion of series capacitor results in severe subsynchronous torques. The subsynchronous torque leads to gene...Series compensation has proven to increase stability in transmission of electric power. On the other hand insertion of series capacitor results in severe subsynchronous torques. The subsynchronous torque leads to generator-turbine shaft damage. Mitigation of subsynchronous transient torques is achieved through resistor bank connected to generator terminals. The insertion of resistor bank is controlled by fuzzy logic controller. The proposed controller has been tested on IEEE First Benchmark Model and it proved to have good damping for the torsional torques.展开更多
In subsynchronous resonance (SSR) systems where shaft systems of turbine-generator sets are coupling with electric networks, Hopf bifurcation will occur under certain conditions. Some singularity phenomena may generat...In subsynchronous resonance (SSR) systems where shaft systems of turbine-generator sets are coupling with electric networks, Hopf bifurcation will occur under certain conditions. Some singularity phenomena may generate when the hysteretic behavior of couplings in the shaft systems is considered. In this paper, the intrinsic multiple-scale harmonic balance method is extended to the nonlinear autonomous system with the non-analytic property, and the dynamic complexities of the system near the Hopf bifurcation point are analyzed.展开更多
With more and more wind power generation integrated into power grids to replace the conventional turbine-generator (T-G) units,how the subsynchronous resonance (SSR) of conventional T-G units is affected becomes an im...With more and more wind power generation integrated into power grids to replace the conventional turbine-generator (T-G) units,how the subsynchronous resonance (SSR) of conventional T-G units is affected becomes an important technical issue.In this paper,a group of T-G units are interconnected with a series compensated transmission line,and some units are substituted by a nearby DFIG-based wind farm (WF).Under such circumstances,the SSR of power systems would change accordingly.This paper establishes the mathematical model to analyze the torsional interaction (TI) and the induction generator effect of the T-G units.Both eigenvalue analysis and time domain simulations demonstrate the impact of DFIG-based WF on SSR of power systems and how the control parameters of wind farms can affect the SSR.展开更多
This paper proposes an implicit function based open-loop analysis method to detect the subsynchronous resonance(SSR),including asymmetric subsynchronous modal attraction(ASSMA)and asymmetric subsynchronous modal repul...This paper proposes an implicit function based open-loop analysis method to detect the subsynchronous resonance(SSR),including asymmetric subsynchronous modal attraction(ASSMA)and asymmetric subsynchronous modal repulsion(ASSMR),of doubly-fed induction generator based wind farms(DFIG-WFs)penetrated power systems.As some important parameters of DFIG-WF are difficult to obtain,reinforcement learning and least squares method are applied to identify those important parameters.By predicting the location of closed-loop subsynchronous oscillation(SSO)modes based on the calculation of partial differentials of characteristic equation,both ASSMA and ASSMR can be found.The proposed method in this paper can select SSO modes which move to the right half complex planes as control parameters change.Besides,the proposed open-loop analysis method is adaptive to parameter uncertainty.Simulation studies are carried out on the 4-machine 11-bus power system to verify properties of the proposed method.展开更多
The creation of a suitable wide area monitoring system(WAMS) is widely recognized as an essential aspect of delivering a power system that will be secure,efficient and sustainable for the foreseeable future. In Great ...The creation of a suitable wide area monitoring system(WAMS) is widely recognized as an essential aspect of delivering a power system that will be secure,efficient and sustainable for the foreseeable future. In Great Britain(GB), the deployment of the first WAMS to monitor the entire power system in real time was the responsibility of the visualization of real time system dynamics using enhanced monitoring(VISOR) project. The core scope of the VISOR project is to deploy this WAMS and demonstrate how WAMS applications can in the near term provide system operators and planners with clear, actionable information. This paper presents the wider scope of the VISOR project and the GB wide WAMS that has been deployed. Furthermore, the paper describes some of the WAMS applications that have been deployed and provides examples of the measurement device performance issues that have been encountered during the project.展开更多
文摘Series compensation has proven to increase stability in transmission of electric power. On the other hand insertion of series capacitor results in severe subsynchronous torques. The subsynchronous torque leads to generator-turbine shaft damage. Mitigation of subsynchronous transient torques is achieved through resistor bank connected to generator terminals. The insertion of resistor bank is controlled by fuzzy logic controller. The proposed controller has been tested on IEEE First Benchmark Model and it proved to have good damping for the torsional torques.
基金The project supported by the National Natural Science Foundation of China(as a key project)the State Education Committee Pre-research Foundation.
文摘In subsynchronous resonance (SSR) systems where shaft systems of turbine-generator sets are coupling with electric networks, Hopf bifurcation will occur under certain conditions. Some singularity phenomena may generate when the hysteretic behavior of couplings in the shaft systems is considered. In this paper, the intrinsic multiple-scale harmonic balance method is extended to the nonlinear autonomous system with the non-analytic property, and the dynamic complexities of the system near the Hopf bifurcation point are analyzed.
文摘With more and more wind power generation integrated into power grids to replace the conventional turbine-generator (T-G) units,how the subsynchronous resonance (SSR) of conventional T-G units is affected becomes an important technical issue.In this paper,a group of T-G units are interconnected with a series compensated transmission line,and some units are substituted by a nearby DFIG-based wind farm (WF).Under such circumstances,the SSR of power systems would change accordingly.This paper establishes the mathematical model to analyze the torsional interaction (TI) and the induction generator effect of the T-G units.Both eigenvalue analysis and time domain simulations demonstrate the impact of DFIG-based WF on SSR of power systems and how the control parameters of wind farms can affect the SSR.
基金supported in part by the State Key Program of National Natural Science Foundation of China under Grant No.U1866210the National Natural Science Foundation of China under Grant No.51807067.
文摘This paper proposes an implicit function based open-loop analysis method to detect the subsynchronous resonance(SSR),including asymmetric subsynchronous modal attraction(ASSMA)and asymmetric subsynchronous modal repulsion(ASSMR),of doubly-fed induction generator based wind farms(DFIG-WFs)penetrated power systems.As some important parameters of DFIG-WF are difficult to obtain,reinforcement learning and least squares method are applied to identify those important parameters.By predicting the location of closed-loop subsynchronous oscillation(SSO)modes based on the calculation of partial differentials of characteristic equation,both ASSMA and ASSMR can be found.The proposed method in this paper can select SSO modes which move to the right half complex planes as control parameters change.Besides,the proposed open-loop analysis method is adaptive to parameter uncertainty.Simulation studies are carried out on the 4-machine 11-bus power system to verify properties of the proposed method.
基金supported by the GB Network Innovation Competition(NIC)
文摘The creation of a suitable wide area monitoring system(WAMS) is widely recognized as an essential aspect of delivering a power system that will be secure,efficient and sustainable for the foreseeable future. In Great Britain(GB), the deployment of the first WAMS to monitor the entire power system in real time was the responsibility of the visualization of real time system dynamics using enhanced monitoring(VISOR) project. The core scope of the VISOR project is to deploy this WAMS and demonstrate how WAMS applications can in the near term provide system operators and planners with clear, actionable information. This paper presents the wider scope of the VISOR project and the GB wide WAMS that has been deployed. Furthermore, the paper describes some of the WAMS applications that have been deployed and provides examples of the measurement device performance issues that have been encountered during the project.