期刊文献+
共找到6篇文章
< 1 >
每页显示 20 50 100
Monte Carlo method for evaluation of surface emission rate measurement uncertainty
1
作者 Yuan-Qiao Li Min Lin +4 位作者 Li-Jun Xu Rui Luo Yu-He Zhang Qian-Xi Ni Yun-Tao Liu 《Nuclear Science and Techniques》 SCIE EI CAS CSCD 2024年第7期126-136,共11页
The aim of this study is to evaluate the uncertainty of 2πα and 2πβ surface emission rates using the windowless multiwire proportional counter method.This study used the Monte Carlo method (MCM) to validate the co... The aim of this study is to evaluate the uncertainty of 2πα and 2πβ surface emission rates using the windowless multiwire proportional counter method.This study used the Monte Carlo method (MCM) to validate the conventional Guide to the Expression of Uncertainty in Measurement (GUM) method.A dead time measurement model for the two-source method was established based on the characteristics of a single-channel measurement system,and the voltage threshold correction factor measurement function was indirectly obtained by fitting the threshold correction curve.The uncertainty in the surface emission rate was calculated using the GUM method and the law of propagation of uncertainty.The MCM provided clear definitions for each input quantity and its uncertainty distribution,and the simulation training was realized with a complete and complex mathematical model.The results of the surface emission rate uncertainty evaluation for four radioactive plane sources using both methods showed the uncertainty’s consistency E_(n)<0.070 for the comparison of each source,and the uncertainty results of the GUM were all lower than those of the MCM.However,the MCM has a more objective evaluation process and can serve as a validation tool for GUM results. 展开更多
关键词 surface emission rate Monte Carlo method METROLOGY Probability distribution function Dead time low-energy loss correction Least-squares method
下载PDF
Modeling of Inner Surface Modification of a Cylindrical Tube by Plasma-Based Low-Energy Ion Implantation
2
作者 郑博聪 王克胜 雷明凯 《Plasma Science and Technology》 SCIE EI CAS CSCD 2015年第4期309-316,共8页
The inner surface modification process by plasma-based low-energy ion implantation(PBLEII)with an electron cyclotron resonance(ECR)microwave plasma source located at the central axis of a cylindrical tube is model... The inner surface modification process by plasma-based low-energy ion implantation(PBLEII)with an electron cyclotron resonance(ECR)microwave plasma source located at the central axis of a cylindrical tube is modeled to optimize the low-energy ion implantation parameters for industrial applications.In this paper,a magnetized plasma diffusion fluid model has been established to describe the plasma nonuniformity caused by plasma diffusion under an axial magnetic field during the pulse-off time of low pulsed negative bias.Using this plasma density distribution as the initial condition,a sheath collisional fluid model is built up to describe the sheath evolution and ion implantation during the pulse-on time.The plasma nonuniformity at the end of the pulse-off time is more apparent along the radial direction compared with that in the axial direction due to the geometry of the linear plasma source in the center and the difference between perpendicular and parallel plasma diffusion coefficients with respect to the magnetic field.The normalized nitrogen plasma densities on the inner and outer surfaces of the tube are observed to be about 0.39 and 0.24,respectively,of which the value is 1 at the central plasma source.After a 5μs pulse-on time,in the area less than 2 cm from the end of the tube,the nitrogen ion implantation energy decreases from 1.5 keV to 1.3 keV and the ion implantation angle increases from several degrees to more than 40°;both variations reduce the nitrogen ion implantation depth.However,the nitrogen ion implantation dose peaks of about 2×10^(10)-7×10^(10)ions/cm^2 in this area are 2-4 times higher than that of 1.18×10^(10)ions/cm^2 and 1.63×10^(10)ions/cm^2 on the inner and outer surfaces of the tube.The sufficient ion implantation dose ensures an acceptable modification effect near the end of the tube under the low energy and large angle conditions for nitrogen ion implantation,because the modification effect is mainly determined by the ion implantation dose,just as the mass transfer process in PBLEII is dominated by low-energy ion implantation and thermal diffusion.Therefore,a comparatively uniform surface modification by the low-energy nitrogen ion implantation is achieved along the cylindrical tube on both the inner and outer surfaces. 展开更多
关键词 plasma-based low-energy ion implantation inner surface modification magnetized plasma diffusion fluid model sheath collisional fluid model
下载PDF
The Fabrication of Microstructure Surface of Superhydrophobic Coating by Surface Gelation Technology 被引量:4
3
作者 DUAN Hui WANG Houzhi +1 位作者 ZHAO Lei ZHAO Huizhong 《Journal of Wuhan University of Technology(Materials Science)》 SCIE EI CAS 2008年第2期163-165,共3页
The microstructured surface of materials were fabricated by a two-step acid-base catalyzed sol-gel process. In fluorinated polymer with PTFE doping, the well-proportioned composite sols were prepared using sol-gel pro... The microstructured surface of materials were fabricated by a two-step acid-base catalyzed sol-gel process. In fluorinated polymer with PTFE doping, the well-proportioned composite sols were prepared using sol-gel processing under the hydrochloric acid and deficiency of water conditions. After the substrate was coated by composite sols, and the gelation treatment on the surface of composite coating, the micrometer-scale and nanometer-scale hierarchical structures were formed in surface layer of material. XPS and TEM technologies were employed to identify that the gelation occurs just on the surface of composite coating. The morphology of coating surface was observed by SEM and AFM technologies. The microstructured surface of material can be fabricated using this inexpensive and easily controlled method on low surface energy resin materials, the super-hydrophobic coatings materials can be prepared. 展开更多
关键词 surface gelation technology ROUGHNESS contact angle super-hydrophobic
下载PDF
Development of Bionic Polymers 被引量:5
4
作者 Xu Jian Xie Qiongdan +6 位作者 Guo Xinlin Feng Lin Jiang Lei Tang Wenghong Luo Xiandong Zhang Xiaoli Han Charles C. 《合成化学》 CAS CSCD 2004年第z1期89-90,共2页
关键词 BIONICS super-hydrophobic polymer surface lotus-effect
下载PDF
Preparation and Characterization of PVC/PAN Membrane Used as Medical Exhaust Membranes
5
作者 王洪 张磊 朱益德 《Journal of Donghua University(English Edition)》 EI CAS 2017年第2期229-232,共4页
The wet phase inversion process was used to prepare a kind of medical exhaust membranes with super-hydrophobicity and good gas permeability capacity by using non-woven fabric as the support base.The influences of solu... The wet phase inversion process was used to prepare a kind of medical exhaust membranes with super-hydrophobicity and good gas permeability capacity by using non-woven fabric as the support base.The influences of solution temperature,the evaporation time,the content of the non-solvent additive and the ratio of polyvinyl chloride(PVC)/polyacrylonitrile(PAN) on the gas permeability capacity and hydrostatic pressure of the resultant membranes were investigated.A kind of composite membrane with gas permeability about 2 800 mL/min and hydrostatic pressure of 36 kPa was obtained.In addition,the relationship between the properties and structure of the membrane was analyzed. 展开更多
关键词 super-hydrophobic MEMBRANE polyvinyl chloride(PVC) surface roughness nonwoven fabric
下载PDF
n-Octadecanethiol Self-Assembled Monolayer Coating with Microscopic Roughness for Dropwise Condensation of Steam 被引量:2
6
作者 Liang CHEN Shiqiang LIANG +3 位作者 Runsheng YAN Yanjun CHENG Xiulan HUA Shuling CHEN 《Journal of Thermal Science》 SCIE EI CAS CSCD 2009年第2期160-165,共6页
Here we presented a novel technology to achieve a Super-hydrophobic coating with microscopic roughness on copper surface. First, make a layer of verdigris grow on the fresh pure copper surface. Gain it by exposing the... Here we presented a novel technology to achieve a Super-hydrophobic coating with microscopic roughness on copper surface. First, make a layer of verdigris grow on the fresh pure copper surface. Gain it by exposing the copper to air and the mist of acetic acid solution. The green coating is a mixture of basic copper(II) carbonate and copper(II) acetate. Second heat the coating and make it decompose to CuO. Lastly, form an n-octadecanethiol self-assembled monolayers coating on the outermost surface. Contact angle test, scanning electron microscope analysis and electrochemical testing were carded out to characterize the surface, and a heat transfer experiment for dropwise condensation of steam was performed also. Results show that the modified surface bears a few Super-hydrophobic features, the static contact angle is higher than that in literatures, reaching 153.1±1.7°. The microscopic roughness can be seen in SEM images, differing much from H2O2 etched surface and bare copper surface. The condensation of steam on the surface is a typical form of dropwise condensation, in the measured range of temperature difference, under 0.1 MPa, the average convection heat transfer coefficients of the vertical surface are 1.7-2.1 times for those of film condensation. At the same time, the inhibition efficiency of surface is improved to some extent comparing with the same kind of SAMs, which suggests that the lifetime of maintenance dropwise condensation would have the possibility to surpass the existing record. 展开更多
关键词 Dropwise condensation Self-assembled monolayers Microscopic roughness super-hydrophobic surface Heat transfer coefficient
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部