Analysis of the handling of ophthalmic surgical instruments in hospitals
1
作者 Xingling Deng Chunmei Du +2 位作者 Jiehui Huang Wenyuan Wang Xiulan Feng 《Annals of Eye Science》 2019年第1期61-65,共5页
Background:We investigated the procedures used by medical institutions in Guangdong Province for reprocessing ophthalmic surgical instruments and analyzed the problems identified in order to improve the quality of cle... Background:We investigated the procedures used by medical institutions in Guangdong Province for reprocessing ophthalmic surgical instruments and analyzed the problems identified in order to improve the quality of cleaning medical instruments and its management.Methods:The reprocessing of ophthalmic surgical instruments was investigated in 72 hospitals in Guangdong Province using a questionnaire designed for this purpose.Results:Ophthalmic surgical instruments underwent centralized reprocessing in the disinfection and supply centers in 50%of the 72 hospitals.Cataract phacoemulsification surgery was the main ophthalmic surgery performed in 94%of the 72 hospitals.The main reasons for using centralized reprocessing were an insufficient supply of ophthalmic surgical instruments,short turnaround times between surgeries,and the high cost of losing these precise and fragile instruments.Manual processing was the predominant method of reprocessing ophthalmic surgical instruments;enzyme detergents were used in 63.89%of the hospitals;and 48.61%of the hospitals used N-model small pressure-steam sterilizers for the ophthalmic surgical instruments.Conclusions:In order to improve the quality and management of the cleaning of medical instruments,and guarantee high-quality medical care,the following measures are recommended.Centralized management of ophthalmic surgical instruments should be based on the instruments’characteristics.Pay more attention to reprocessing site locations and staff training.Choose detergents based on manufacturers’instructions for use with specific instruments.Increase the number of available ophthalmic instruments in accordance with their demand and select appropriate small pressure-steam sterilizers. 展开更多
关键词 Ophthalmic surgical instruments centralized reprocessing ANALYSIS
下载PDF
Study of Individual Characteristic Abdominal Wall Thickness Based on Magnetic Anchored Surgical Instruments 被引量:4
2
作者 Ding-Hui Dong Wen-Yan Liu +4 位作者 Hai-Bo Feng Yi-Li FU Shi Huang Jun-Xi Xiang Yi Lyu 《Chinese Medical Journal》 SCIE CAS CSCD 2015年第15期2040-2044,共5页
Background:Magnetic anchored surgical instruments (MASI),relying on magnetic force,can break through the limitations of the single port approach in dexterity.Individual characteristic abdominal wall thickness (IC... Background:Magnetic anchored surgical instruments (MASI),relying on magnetic force,can break through the limitations of the single port approach in dexterity.Individual characteristic abdominal wall thickness (ICAWT) deeply influences magnetic force that determines the safety of MASI.The purpose of this study was to research the abdominal wall characteristics in MASI applied environment to find ICAWT,and then construct an artful method to predict ICAWT,resulting in better safety and feasibility for MASI.Methods:For MASI,ICAWT is referred to the thickness of thickest point in the applied environment.We determined ICAWT through finding the thickest point in computed tomography scans.We also investigated the traits of abdominal wall thickness to discover the factor that can be used to predict ICAWT.Results:Abdominal wall at C point in the middle third lumbar vertebra plane (L3) is the thickest during chosen points.Fat layer thickness plays a more important role in abdominal wall thickness than muscle layer thickness."BMI-ICAWT" curve was obtained based on abdominal wall thickness of C point in L3 plane,and the expression was as follow:f(x) =P1 × x^2 + P2 x x + P3,where P1 =0.03916 (0.01776,0.06056),P2 =1.098 (0.03197,2.164),P3 =-18.52 (-31.64,-5.412),R-square:0.99.Conclusions:Abdominal wall thickness of C point at L3 could be regarded as ICAWT.BMI could be a reliable predictor of ICAWT.In the light of "BMI-ICAWT" curve,we may conveniently predict ICAWT by BMI,resulting a better safety and feasibility for MASI. 展开更多
关键词 Individual Characteristic Abdominal Wall Thickness Magnetic Anchored surgical instruments Minimally Invasive Surgery
原文传递
Analysis and Design of Surgical Instrument Localization Algorithm
3
作者 Siyu Lu Jun Yang +4 位作者 Bo Yang Zhengtong Yin Mingzhe Liu Lirong Yin Wenfeng Zheng 《Computer Modeling in Engineering & Sciences》 SCIE EI 2023年第10期669-685,共17页
With the help of surgical navigation system,doctors can operate on patients more intuitively and accurately.The positioning accuracy and real-time performance of surgical instruments are very important to the whole sy... With the help of surgical navigation system,doctors can operate on patients more intuitively and accurately.The positioning accuracy and real-time performance of surgical instruments are very important to the whole system.In this paper,we analyze and design the detection algorithm of surgical instrument location mark,and estimate the posture of surgical instrument.In addition,we optimized the pose by remapping.Finally,the algorithm of location mark detection proposed in this paper and the posture analysis data of surgical instruments are verified and analyzed through experiments.The final result shows a high accuracy. 展开更多
关键词 surgical navigation system surgical instruments positioning positioning mark detection algorithm matching algorithm posture analysis
下载PDF
A novel set of surgical instruments facilitate the procedure of laparoscopic pyeloplasty 被引量:2
4
作者 CHEN Wen-zheng GUO Fei +5 位作者 LIYun Riccardo Autorino LI Jin-yi WANG Hui-qing Fatih Altunrende SUN Ying-hao 《Chinese Medical Journal》 SCIE CAS CSCD 2012年第21期3791-3794,共4页
Background Open pyeloplasty has been historically described as the gold standard for the surgical treatment of ureteropelvic junction obstruction (UPJO), even if new techniques have recently gained a prominent role ... Background Open pyeloplasty has been historically described as the gold standard for the surgical treatment of ureteropelvic junction obstruction (UPJO), even if new techniques have recently gained a prominent role in this field. Laparoscopic pyeloplasty (LP) is not widely prevelant because of the technically challenging nature and it represents the gold standard for UPJO only in expert hands. To overcome some difficulties and technical challenges encountered during pure laparoscopic pyeloplasty, we designed a set of new instruments and assessed them using porcine model. 展开更多
关键词 laparoscopic pyeloplasty surgical instrument
原文传递
Should the Surgical Instrument Parts That Are Broken and Remain in the Distance of the Disc Be Removed? Should It Be Quit? A Case Report
5
作者 Saim Kale Mehmet Tokmak Mehmet Daimoglu 《Open Journal of Modern Neurosurgery》 2022年第2期97-103,共7页
Background and Aim: Lumbar posterior open microdiscectomy is a procedure that is widely used to treat lumbar disc diseases. These operations have a low risk of complications. It is unusual for the tool to break and re... Background and Aim: Lumbar posterior open microdiscectomy is a procedure that is widely used to treat lumbar disc diseases. These operations have a low risk of complications. It is unusual for the tool to break and remain in the intervertebral space during surgery. In this situation, we wanted to provide a set of suggestions based on our research of the literature on pituitary forceps blade fractures and the procedure for removing the fractured portion from the disc space during lumbar posterior open microdiscectomy surgery. Case Presentation: 10 days ago, a 37-year-old female patient presented to our clinic complaining of low back pain, left leg pain, and left foot weakness. A diagnosis of lumbar disc herniation necessitating surgery was obtained following neurological and radiographic examinations. The patient was advised to have surgery. The patient had standard lumbar microdiscectomy surgery. However, the tip of the pituitary forceps was broken during disc removal and remained in the L5-S1 disc space. The scope confirmed that the alien object was in space. After the evaluation, it was decided to remove the piece of instrument that was broken and remained in the disc space. The broken surgical handpiece was removed and documented under fluoroscopy. Additionally, it was forwarded to the technical unit for examination. Conclusion: A few case reports in the literature describe a surgical tool piece fracture that remained in the disc distance of the lumbar microdiscectomy. Complication management may be time-consuming and risky. Such a complication should be addressed and resolved appropriately because this situation might have detrimental terms on surgical risks and the legal procedure. 展开更多
关键词 Lumbar Microdiscectomy Complication Pituitary Disc Rongeur surgical Instrument Fracture
下载PDF
Five-in-one: a novel, cost-effective yet simple use of micro needle holder
6
作者 Ning Gao Jia-Li Zhu +2 位作者 An-Le Su Lie-Ling Kou Zhao Liu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2022年第4期657-660,共4页
AIM: To achieve a balance between efficiency and cost in the management of medical instrument by the use of micro needle holder. METHODS: In this study, the novel multifunctional use of micro needle holders was perfor... AIM: To achieve a balance between efficiency and cost in the management of medical instrument by the use of micro needle holder. METHODS: In this study, the novel multifunctional use of micro needle holders was performed between 2018 and 2019 at the Department of Ophthalmology in the 4 hospitals in Shaanxi Province. In this innovation, the micro needle holders were initially used as micro forceps to remove sutures, as eye spud to safety extract foreign body from cornea, as ciliary forceps to remove trichiasis, as well as punctal dilator to dilate most small puncta. RESULTS: Using this technique, the medical costs of both procurement and sterilization were cut off in the selected 4 hospitals. The purchase cost has dropped by roughly 50%. The sterilization cost was decreased by about 30%. CONCLUSION: The innovation in the five-in-one multifunctional use of micro needle holders saves the medical costs. 展开更多
关键词 micro needle holder medical instrument ocular surgical instruments
下载PDF
Migration of a Hem-o-Lok clip to the renal pelvis after laparoscopic partial nephrectomy:A case report
7
作者 Ji Sun Li-Wei Zhao +2 位作者 Xu-Liang Wang Jia-Guo Huang Yi Fan 《World Journal of Clinical Cases》 SCIE 2022年第10期3188-3193,共6页
BACKGROUND Hem-o-Lok clip(HOLC)has been widely used in laparoscopic surgery due to its ease of application and secure clamping,though the rare complications associated with this technique should not be ignored.The rar... BACKGROUND Hem-o-Lok clip(HOLC)has been widely used in laparoscopic surgery due to its ease of application and secure clamping,though the rare complications associated with this technique should not be ignored.The rare complications of laparoscopic partial nephrectomy consist of the clip migrating into the renal pelvis and acting as a nidus for stone formation.CASE SUMMARY The case described here involved a 63-year-old woman who was found with stones in the right kidney and upper ureter during a recent reexamination following laparoscopic partial nephrectomy.We performed percutaneous nephrolithotomy for her,but during the operation,it was found that the center of the stone within the kidney was a HOLC,which was removed with forceps.For this reason,we speculate that the HOLC,which was employed to halt tumor wound bleeding,spontaneously drifted into the renal pelvis and formed kidney stones,with the clip being initially misdiagnosed as a kidney stone.CONCLUSION By reviewing related case reports,we conclude that in order to prevent complications related to HOLC,loose clips should be actively searched for and retrieved from the wound during urinary tract surgery,while the deployment of clips in close proximity of anastomotic stoma of collecting systems should be avoided. 展开更多
关键词 Partial nephrectomy Foreign body stones Hem-o-Lok(surgical instrument) Case report
下载PDF