Sweat loss monitoring is important for understanding the body’s thermoregulation and hydration status,as well as for comprehensive sweat analysis.Despite recent advances,developing a low-cost,scalable,and universal m...Sweat loss monitoring is important for understanding the body’s thermoregulation and hydration status,as well as for comprehensive sweat analysis.Despite recent advances,developing a low-cost,scalable,and universal method for the fabrication of colorimetric microfluidics designed for sweat loss monitoring remains challenging.In this study,we propose a novel laserengraved surface roughening strategy for various flexible substrates.This process permits the construction of microchannels that show distinct structural reflectance changes before and after sweat filling.By leveraging these unique optical properties,we have developed a fully laser-engraved microfluidic device for the quantification of naked-eye sweat loss.This sweat loss sensor is capable of a volume resolution of 0.5µL and a total volume capacity of 11µL,and can be customized to meet different performance requirements.Moreover,we report the development of a crosstalk-free dual-mode sweat microfluidic system that integrates an Ag/AgCl chloride sensor and a matching wireless measurement flexible printed circuit board.This integrated system enables the real-time monitoring of colorimetric sweat loss signals and potential ion concentration signals without crosstalk.Finally,we demonstrate the potential practical use of this microfluidic sweat loss sensor and its integrated system for sports medicine via on-body studies.展开更多
Dear Editor,Three dimensional(3D)bioprinted extracellular matrix(ECM)can be used to provide both biochemical and biophysical cues to direct mesenchymal stem cells(MSCs)differentiation,and then differentiated cells wer...Dear Editor,Three dimensional(3D)bioprinted extracellular matrix(ECM)can be used to provide both biochemical and biophysical cues to direct mesenchymal stem cells(MSCs)differentiation,and then differentiated cells were isolated for implantation in vivo using surgical procedures.However,the reduced cell activity after cell isolation from 3D constructs and low cell retention in injured sites limit its application[1].Methacrylated gelatin(GelMA)hydrogel has the advantage of fast crosslinking,which could resemble complex architectures of tissue construct in vivo[2].Here,we adopted a noninvasive bioprinting procedure to imitate the regenerative microenvironment that could simultaneously direct the sweat gland(SG)and vascular differentiation from MSCs and ultimately promote the replacement of glandular tissue in situ(Fig.1a).展开更多
With the rapid technological innovation in materials engineering and device integration,a wide variety of textilebased wearable biosensors have emerged as promising platforms for personalized healthcare,exercise monit...With the rapid technological innovation in materials engineering and device integration,a wide variety of textilebased wearable biosensors have emerged as promising platforms for personalized healthcare,exercise monitoring,and pre-diagnostics.This paper reviews the recent progress in sweat biosensors and sensing systems integrated into textiles for wearable body status monitoring.The mechanisms of biosensors that are commonly adopted for biomarkers analysis are first introduced.The classification,fabrication methods,and applications of textile conductors in different configurations and dimensions are then summarized.Afterward,innovative strategies to achieve efficient sweat collection with textile-based sensing patches are presented,followed by an in-depth discussion on nanoengineering and system integration approaches for the enhancement of sensing performance.Finally,the challenges of textile-based sweat sensing devices associated with the device reusability,washability,stability,and fabrication reproducibility are discussed from the perspective of their practical applications in wearable healthcare.展开更多
A new CVD method without vacuum condition(CVDWV)was designed in this study,ithad been found that by modifying the flow rate of the carrier gas(N<sub>2</sub>)and the temperature of sur-face reaction,sil...A new CVD method without vacuum condition(CVDWV)was designed in this study,ithad been found that by modifying the flow rate of the carrier gas(N<sub>2</sub>)and the temperature of sur-face reaction,silicon saturator and sample tube,the amount of silica deposited on the external sur-face of the zeolite could be precisely controlled,The changes in the physicochemical properties ofzeolite,such as pore-opening size,acidity and reaction property were investigated.The results ob-tained showed that:modification of the improved CVD method did not change the internal structureand acidity of the zeolite,but could bring about significant change of pore-opening size and reactionproperty as desired.展开更多
Advanced in wireless technologies and flexible materials with great biocompatibility,wearable devices have been utilized in the field of healthcare,sports management,and diseases prevention,which have been widely appl...Advanced in wireless technologies and flexible materials with great biocompatibility,wearable devices have been utilized in the field of healthcare,sports management,and diseases prevention,which have been widely applied in current electronic equipment.Sweat,as a common metabolite on the skin surface,contains a wealth of biomarkers for disease detection and diagnosis.Therefore,developing wearable sweat sensors can provide a non⁃invasive method for health data collecting,sports monitoring,and clinical diagnosis in a convenient way.Recent research in sweat metabolomics has offered a lot of information for sweat analysis and the wearable sweat sensors with small size,various sensing,and transmission units,and good skin contact has exhibited dynamic multi⁃signal detection.This article introduces the biomarkers in sweat related to different diseases and the current development of sweat sensors for users activation monitoring and diseases detection.The barriers and difficulties in the future are also discussed and perspectives in the next generation sweat sensors are proposed.展开更多
基金support from the National Natural Science Foundation of China(No.62174152)。
文摘Sweat loss monitoring is important for understanding the body’s thermoregulation and hydration status,as well as for comprehensive sweat analysis.Despite recent advances,developing a low-cost,scalable,and universal method for the fabrication of colorimetric microfluidics designed for sweat loss monitoring remains challenging.In this study,we propose a novel laserengraved surface roughening strategy for various flexible substrates.This process permits the construction of microchannels that show distinct structural reflectance changes before and after sweat filling.By leveraging these unique optical properties,we have developed a fully laser-engraved microfluidic device for the quantification of naked-eye sweat loss.This sweat loss sensor is capable of a volume resolution of 0.5µL and a total volume capacity of 11µL,and can be customized to meet different performance requirements.Moreover,we report the development of a crosstalk-free dual-mode sweat microfluidic system that integrates an Ag/AgCl chloride sensor and a matching wireless measurement flexible printed circuit board.This integrated system enables the real-time monitoring of colorimetric sweat loss signals and potential ion concentration signals without crosstalk.Finally,we demonstrate the potential practical use of this microfluidic sweat loss sensor and its integrated system for sports medicine via on-body studies.
基金supported by the Science Fund for National Defense Distinguished Young Scholars(2022-JCJQ-ZQ-016)the Key Basic Research Projects of the Foundation Strengthening Plan(2022-JCJQZD-096-00)+2 种基金the National Key Research and Development Program of China(2022YFA1104604)the National Natural Science Foundation of China(32000969)the Key Support Program for Growth Factor Research(SZYZ-TR-03).
文摘Dear Editor,Three dimensional(3D)bioprinted extracellular matrix(ECM)can be used to provide both biochemical and biophysical cues to direct mesenchymal stem cells(MSCs)differentiation,and then differentiated cells were isolated for implantation in vivo using surgical procedures.However,the reduced cell activity after cell isolation from 3D constructs and low cell retention in injured sites limit its application[1].Methacrylated gelatin(GelMA)hydrogel has the advantage of fast crosslinking,which could resemble complex architectures of tissue construct in vivo[2].Here,we adopted a noninvasive bioprinting procedure to imitate the regenerative microenvironment that could simultaneously direct the sweat gland(SG)and vascular differentiation from MSCs and ultimately promote the replacement of glandular tissue in situ(Fig.1a).
基金supported by the National Natural Science Foundation of China(62201243)Fundamental and Applied Research Grant of Guangdong Province(2021A1515110627)+3 种基金Southern University of Science and Technology(Y01796108,Y01796208)RGC Senior Research Fellow Scheme of Hong Kong(SRFS2122-5S04)the Hong Kong Polytechnic University(1-ZVQM),RI-Wear of PolyU(1-CD44)Shenzhen Science and Technology Innovation Committee(SGDX20210823103403033).
文摘With the rapid technological innovation in materials engineering and device integration,a wide variety of textilebased wearable biosensors have emerged as promising platforms for personalized healthcare,exercise monitoring,and pre-diagnostics.This paper reviews the recent progress in sweat biosensors and sensing systems integrated into textiles for wearable body status monitoring.The mechanisms of biosensors that are commonly adopted for biomarkers analysis are first introduced.The classification,fabrication methods,and applications of textile conductors in different configurations and dimensions are then summarized.Afterward,innovative strategies to achieve efficient sweat collection with textile-based sensing patches are presented,followed by an in-depth discussion on nanoengineering and system integration approaches for the enhancement of sensing performance.Finally,the challenges of textile-based sweat sensing devices associated with the device reusability,washability,stability,and fabrication reproducibility are discussed from the perspective of their practical applications in wearable healthcare.
文摘A new CVD method without vacuum condition(CVDWV)was designed in this study,ithad been found that by modifying the flow rate of the carrier gas(N<sub>2</sub>)and the temperature of sur-face reaction,silicon saturator and sample tube,the amount of silica deposited on the external sur-face of the zeolite could be precisely controlled,The changes in the physicochemical properties ofzeolite,such as pore-opening size,acidity and reaction property were investigated.The results ob-tained showed that:modification of the improved CVD method did not change the internal structureand acidity of the zeolite,but could bring about significant change of pore-opening size and reactionproperty as desired.
基金Sponsored by the Basic Research Program of China(Grant No.2019YFB1310200)the Foundation for Innovative Research Groups of the National Natural Science Foundation of China(Grant No.51521003)the Self⁃Planned Task of State Key Laboratory of Robotics and System,Harbin Institute of Technology(Grant Nos.SKLRS201801B and SKLRS201607B).
文摘Advanced in wireless technologies and flexible materials with great biocompatibility,wearable devices have been utilized in the field of healthcare,sports management,and diseases prevention,which have been widely applied in current electronic equipment.Sweat,as a common metabolite on the skin surface,contains a wealth of biomarkers for disease detection and diagnosis.Therefore,developing wearable sweat sensors can provide a non⁃invasive method for health data collecting,sports monitoring,and clinical diagnosis in a convenient way.Recent research in sweat metabolomics has offered a lot of information for sweat analysis and the wearable sweat sensors with small size,various sensing,and transmission units,and good skin contact has exhibited dynamic multi⁃signal detection.This article introduces the biomarkers in sweat related to different diseases and the current development of sweat sensors for users activation monitoring and diseases detection.The barriers and difficulties in the future are also discussed and perspectives in the next generation sweat sensors are proposed.