A multi-gap and multi-channel gas switch with convexo-convex discal planet electrodes was designed and investigated. Eight gaps are formed in series by a trigger electrode, six intermediate electrodes and two high vol...A multi-gap and multi-channel gas switch with convexo-convex discal planet electrodes was designed and investigated. Eight gaps are formed in series by a trigger electrode, six intermediate electrodes and two high voltage electrodes with a uniform gap length of 5 ram. The self breakdown and triggered breakdown performance of the switch are reported. Both the delay time and jitter decrease with the increase in the trigger voltage, switching coefficient and the decrease in the trigger isolating resistor. The delay time of the switch is about 40 ns, and the jitter is less than 2 ns when charged with 4-85 kV and triggered by a voltage pule of -75 kV. The inductance of the switch is about 30 nH.展开更多
The trigger characteristics of a multi-gap gas switch with double insulating layers,a square-groove electrode supporter and a UV pre-ionizing structure are investigated aided by a high sensitivity fiber-bundle array d...The trigger characteristics of a multi-gap gas switch with double insulating layers,a square-groove electrode supporter and a UV pre-ionizing structure are investigated aided by a high sensitivity fiber-bundle array detector, a UV fiber detector, and a framing camera, in addition to standard electrical diagnostics. The fiber-bundle-array detector is used to track the turn-on sequence of each electrode gap at a timing precision of 0.6 ns. Each fiber bundle, including five fibers with different azimuth angles, aims at the whole emitting area of each electrode gap and is fed to a photomultiplier tube. The UV fiber detector with a spectrum response of 260-320 nm,including a fused-quartz fiber of 200 μm in diameter and a solar-blinded photomultiplier tube, is adopted to study the effect of UV pre-ionizing on trigger characteristics. The framing camera,with a capacity of 4 frames per shot and an exposure time of 5 ns, is employed to capture the evolution of channel arcs. Based on the turn-on light signal of each electrode gap, the breakdown delay is divided into statistical delay and formative delay. A decrease in both of them, a smaller switch jitter and more channel arcs are observed with lower gas pressure. An increase in trigger voltage can reduce the statistical delay and its jitter, while higher trigger voltage has a relatively small influence on the formative delay and the number of channel arcs. With the UV pre-ionizing structure at 0.24 MPa gas pressure and 60 kV trigger voltage, the statistical delay and its jitter can be reduced by 1.8 ns and 0.67 ns, while the formative delay and its jitter can only be reduced by 0.5 ns and 0.25 ns.展开更多
快脉冲直线型变压器驱动源(fast linear transformer driver,FLTD)是建设下一代大型Z箍缩装置最有前景的技术路线之一。大型FLTD脉冲源中数以万计气体开关的可靠运行是提高Z箍缩装置可靠性的重要因素。该文基于15 MAZ箍缩科学实验装置的...快脉冲直线型变压器驱动源(fast linear transformer driver,FLTD)是建设下一代大型Z箍缩装置最有前景的技术路线之一。大型FLTD脉冲源中数以万计气体开关的可靠运行是提高Z箍缩装置可靠性的重要因素。该文基于15 MAZ箍缩科学实验装置的FLTD脉冲源设计,采用Monte-Carlo方法建立考虑支路开关自放电及其载荷共享效应的FLTD脉冲源可靠性计算模型,分析开关故障模式及其触发策略对脉冲源可靠性的影响。结果表明,主支路开关自放电产生的故障电压会引起开关级联自放电,降低装置可靠性。若主支路开关工作系数设定在0.5~0.7范围内,FLTD脉冲源故障率可低于1×10^(-4)。此外,触发器及触发支路开关的高可靠性对于提升脉冲源可靠性至关重要,增加触发器脉冲数量、降低触发器自放电故障率能够有效提升脉冲源可靠性,当触发器脉冲数量提升至4倍后,FLTD脉冲源故障率有望降低至1×10^(-5)以下。研究结果为大型FLTD脉冲源的开关工作系数及触发策略的选取提供参考,具有重要的工程应用价值。展开更多
基金supported by National Natural Science Foundation of China(Nos.50477019,50637010)the State Key Laboratory of Electrical Insulation and Power Equipment of China(EIPE.09207)
文摘A multi-gap and multi-channel gas switch with convexo-convex discal planet electrodes was designed and investigated. Eight gaps are formed in series by a trigger electrode, six intermediate electrodes and two high voltage electrodes with a uniform gap length of 5 ram. The self breakdown and triggered breakdown performance of the switch are reported. Both the delay time and jitter decrease with the increase in the trigger voltage, switching coefficient and the decrease in the trigger isolating resistor. The delay time of the switch is about 40 ns, and the jitter is less than 2 ns when charged with 4-85 kV and triggered by a voltage pule of -75 kV. The inductance of the switch is about 30 nH.
基金supported by National Natural Science Foundation of China(No.11105109)
文摘The trigger characteristics of a multi-gap gas switch with double insulating layers,a square-groove electrode supporter and a UV pre-ionizing structure are investigated aided by a high sensitivity fiber-bundle array detector, a UV fiber detector, and a framing camera, in addition to standard electrical diagnostics. The fiber-bundle-array detector is used to track the turn-on sequence of each electrode gap at a timing precision of 0.6 ns. Each fiber bundle, including five fibers with different azimuth angles, aims at the whole emitting area of each electrode gap and is fed to a photomultiplier tube. The UV fiber detector with a spectrum response of 260-320 nm,including a fused-quartz fiber of 200 μm in diameter and a solar-blinded photomultiplier tube, is adopted to study the effect of UV pre-ionizing on trigger characteristics. The framing camera,with a capacity of 4 frames per shot and an exposure time of 5 ns, is employed to capture the evolution of channel arcs. Based on the turn-on light signal of each electrode gap, the breakdown delay is divided into statistical delay and formative delay. A decrease in both of them, a smaller switch jitter and more channel arcs are observed with lower gas pressure. An increase in trigger voltage can reduce the statistical delay and its jitter, while higher trigger voltage has a relatively small influence on the formative delay and the number of channel arcs. With the UV pre-ionizing structure at 0.24 MPa gas pressure and 60 kV trigger voltage, the statistical delay and its jitter can be reduced by 1.8 ns and 0.67 ns, while the formative delay and its jitter can only be reduced by 0.5 ns and 0.25 ns.
文摘快脉冲直线型变压器驱动源(fast linear transformer driver,FLTD)是建设下一代大型Z箍缩装置最有前景的技术路线之一。大型FLTD脉冲源中数以万计气体开关的可靠运行是提高Z箍缩装置可靠性的重要因素。该文基于15 MAZ箍缩科学实验装置的FLTD脉冲源设计,采用Monte-Carlo方法建立考虑支路开关自放电及其载荷共享效应的FLTD脉冲源可靠性计算模型,分析开关故障模式及其触发策略对脉冲源可靠性的影响。结果表明,主支路开关自放电产生的故障电压会引起开关级联自放电,降低装置可靠性。若主支路开关工作系数设定在0.5~0.7范围内,FLTD脉冲源故障率可低于1×10^(-4)。此外,触发器及触发支路开关的高可靠性对于提升脉冲源可靠性至关重要,增加触发器脉冲数量、降低触发器自放电故障率能够有效提升脉冲源可靠性,当触发器脉冲数量提升至4倍后,FLTD脉冲源故障率有望降低至1×10^(-5)以下。研究结果为大型FLTD脉冲源的开关工作系数及触发策略的选取提供参考,具有重要的工程应用价值。