期刊文献+
共找到3,003篇文章
< 1 2 151 >
每页显示 20 50 100
Robust Nonlinear Current Sensorless Control of the Boost Converter with Constant Power Load
1
作者 Said Oucheriah Abul Azad 《Circuits and Systems》 2024年第3期29-43,共15页
The boost converter feeding a constant power load (CPL) is a non-minimum phase system that is prone to the destabilizing effects of the negative incremental resistance of the CPL and presents a major challenge in the ... The boost converter feeding a constant power load (CPL) is a non-minimum phase system that is prone to the destabilizing effects of the negative incremental resistance of the CPL and presents a major challenge in the design of stabilizing controllers. A PWM-based current-sensorless robust sliding mode controller is developed that requires only the measurement of the output voltage. An extended state observer is developed to estimate a lumped uncertainty signal that comprises the uncertain load power and the input voltage, the converter parasitics, the component uncertainties and the estimation of the derivative of the output voltage needed in the implementation of the controller. A linear sliding surface is used to derive the controller, which is simple in its design and yet exhibits excellent features in terms of robustness to external disturbances, parameter uncertainties, and parasitics despite the absence of the inductor’s current feedback. The robustness of the controller is validated by computer simulations. 展开更多
关键词 Boost Converter Robust Sliding Mode Control constant Power Load (CPL) current-Sensorless Control Extended State Observer
下载PDF
Dynamics and stabilization of peak current-mode controlled buck converter with constant current load 被引量:3
2
作者 冷敏瑞 周国华 +1 位作者 张凯暾 李振华 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第10期101-109,共9页
The discrete iterative map model of peak current-mode controlled buck converter with constant current load(CCL),containing the output voltage feedback and ramp compensation, is established in this paper. Based on th... The discrete iterative map model of peak current-mode controlled buck converter with constant current load(CCL),containing the output voltage feedback and ramp compensation, is established in this paper. Based on this model the complex dynamics of this converter is investigated by analyzing bifurcation diagrams and the Lyapunov exponent spectrum. The effects of ramp compensation and output voltage feedback on the stability of the converter are investigated. Experimental results verify the simulation and theoretical analysis. The stability boundary and chaos boundary are obtained under the theoretical conditions of period-doubling bifurcation and border collision. It is found that there are four operation regions in the peak current-mode controlled buck converter with CCL due to period-doubling bifurcation and border-collision bifurcation. Research results indicate that ramp compensation can extend the stable operation range and transfer the operating mode, and output voltage feedback can eventually eliminate the coexisting fast-slow scale instability. 展开更多
关键词 buck converter constant current load discrete iterative map model ramp compensation
下载PDF
Low voltage substrate current: a monitor for interface states generation in ultra-thin oxide n-MOSFETs under constant voltage stresses
3
作者 王彦刚 许铭真 谭长华 《Chinese Physics B》 SCIE EI CAS CSCD 2007年第11期3502-3506,共5页
The low voltage substrate current (Ib) has been studied based on generation kinetics and used as a monitor of interface states (Nit) generation for ultra-thin oxide n-MOSFETs under constant voltage stress. It is f... The low voltage substrate current (Ib) has been studied based on generation kinetics and used as a monitor of interface states (Nit) generation for ultra-thin oxide n-MOSFETs under constant voltage stress. It is found that the low voltage Ib is formed by electrons tunnelling through interface states, and the variations of Ib(△Ib) are proportional to variations of Nit (△Nit). The Nit energy distributions were determined by differentiating Nit(Vg). The results have been compared with that measured by using gate diode technique. 展开更多
关键词 interface states substrate current ultra-thin oxide constant voltage stress
下载PDF
Field-induced phase transitions in chiral smectic liquid crystals studied by the constant current method
4
作者 H Dhaouadi R Zgueb +2 位作者 O Riahi F Trabelsi T Othman 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第5期373-379,共7页
In ferroelectric liquid crystals, phase transitions can be induced by an electric field. The current constant method allows these transition to be quickly localized and thus the(E, T) phase diagram of the studied pr... In ferroelectric liquid crystals, phase transitions can be induced by an electric field. The current constant method allows these transition to be quickly localized and thus the(E, T) phase diagram of the studied product can be obtained.In this work, we make a slight modification to the measurement principles based on this method. This modification allows the characteristic parameters of ferroelectric liquid crystal to be quantitatively measured. The use of a current square signal highlights a phenomenon of ferroelectric hysteresis with remnant polarization at null field, which points out an effect of memory in this compound. 展开更多
关键词 chiral smectic liquid crystal constant current method ferroelectric polarization dielectric permittivity
下载PDF
Numerical Solution of MHD Convection and Mass Transfer Flow of Viscous Incompressible Fluid about an Inclined Plate with Hall Current and Constant Heat Flux
5
作者 Mohammad Wahiduzzaman Runu Biswas +2 位作者 Md. Eaqub Ali Md. Shakhaoath Khan Ifsana Karim 《Journal of Applied Mathematics and Physics》 2015年第12期1688-1709,共22页
The present numerically study investigates the influence of the Hall current and constant heat flux on the Magneto hydrodynamic (MHD) natural convection boundary layer viscous incompressible fluid flow in the manifest... The present numerically study investigates the influence of the Hall current and constant heat flux on the Magneto hydrodynamic (MHD) natural convection boundary layer viscous incompressible fluid flow in the manifestation of transverse magnetic field near an inclined vertical permeable flat plate. It is assumed that the induced magnetic field is negligible compared with the imposed magnetic field. The governing boundary layer equations have been transferred into non-similar model by implementing similarity approaches. The physical dimensionless parameter has been set up into the model as Prandtl number, Eckert number, Magnetic parameter, Schmidt number, local Grashof number and local modified Grashof number. The numerical method of Nactsheim-Swigert shooting iteration technique together with Runge-Kutta six order iteration scheme has been used to solve the system of governing non-similar equations. The physical effects of the various parameters on dimensionless primary velocity profile, secondary velocity profile, and temperature and concentration profile are discussed graphically. Moreover, the local skin friction coefficient, the local Nusselt number and Sherwood number are shown in tabular form for various values of the parameters. 展开更多
关键词 MHD HEAT and Mass Transfer HALL current Inclined Plate constant HEAT FLUX
下载PDF
Non-inverting buck-boost DC-DC converter based on constant inductor current control
6
作者 Yao Suyi Jiang Jianguo 《Journal of Southeast University(English Edition)》 EI CAS 2021年第2期171-176,共6页
The hysteresis control combined with PWM control non-inverting buck-boost was proposed to improve the light load efficiency and power density.The constant inductor current control(CICC)was established to mitigate the ... The hysteresis control combined with PWM control non-inverting buck-boost was proposed to improve the light load efficiency and power density.The constant inductor current control(CICC)was established to mitigate the dependence on the external components and device variation and make smooth transition between hysteresis control loop and pulse width modulation(PWM)control loop.The small signal model was deduced for the buck and boost operation mode.The inductor current slope control(ICSC)was proposed to implement the automatic mode transition between buck and boost mode in one switching cycle.The results show that the converter prototype has good dynamic response capability,achieving 94%efficiency and 95%peak efficiency at full 10 A load current. 展开更多
关键词 four switch buck-boost converter inductor current slope control constant inductor current control small signal model
下载PDF
Multi-stage constant current charging strategy considering SOC intervals and voltage thresholds
7
作者 Yu Zhang Si Xu Tiezhou Wu 《Global Energy Interconnection》 EI CAS CSCD 2022年第2期143-153,共11页
Conventional multi-stage constant current charging strategies often use higher multiples of current to charge the battery in pursuit of shorter charging times.However,this leads to an increase in battery temperature,w... Conventional multi-stage constant current charging strategies often use higher multiples of current to charge the battery in pursuit of shorter charging times.However,this leads to an increase in battery temperature,while shortening the charging time.This in turn affects the safety of the charging process.Furthermore,the higher charging currents are not ideal for shortening the charging time in the later stages of charging.To solve the aforementioned problems,in this study,a multi-stage constant current charging strategy is presented.This strategy can shorten the battery charging time by using the increase in battery temperature during the charging process as a constraint,using a genetic algorithm to calculate the charging current value,and investigating the phased approach to charging.Finally,the charging strategy is experimentally validated at different ambient temperatures and different initial SOCs.The experimental results show that the charging strategy proposed in this paper not only reduces the amount of calculations,but also reduces the temperature rise by up to 46.4%and charging time by up to 4.2%under different operating conditions. 展开更多
关键词 Charging time Battery temperature rise Genetic algorithm Multi-stage constant current charging
下载PDF
An improved analysis method of constant-current charge/discharge curves and its application to nickel hydroxide electrode
8
作者 潘滔 王建明 +3 位作者 陈惠 赵彦琳 肖慧明 张鉴清 《中国有色金属学会会刊:英文版》 CSCD 2003年第2期462-466,共5页
The derivative of charge and discharge curves (d t /d E vs E plot) can be used to describe the charge and discharge process more exactly. The d t /d E ? 獷 plots of nickel hydroxide electrode at different charge/disch... The derivative of charge and discharge curves (d t /d E vs E plot) can be used to describe the charge and discharge process more exactly. The d t /d E ? 獷 plots of nickel hydroxide electrode at different charge/discharge rates and intermittent discharge experiment are discussed. Though the d t /d E ? 獷 plot is affected by many factors, it clearly has intrinsic relation with the nature of active material such as conductivity and thermodynamic potential of active material, which changes with the state of charge. The d t /d E—E plot can also be applied to other electrochemical active materials, especially to those having several phases during charge or discharge. 展开更多
关键词 镍氢电池 电极 分析方法 改进 放电曲线
下载PDF
Constant Ripple Current Control for Switching DC-DC Converter
9
作者 Gwo-Tarng Chern Jenn-Jong Shieh 《Journal of Energy and Power Engineering》 2012年第9期1437-1441,共5页
The adapted DC-DC converters should be smaller in size and have a small output current ripple to meet the increasing demand for low voltages with high performance and high density micro processors for several microele... The adapted DC-DC converters should be smaller in size and have a small output current ripple to meet the increasing demand for low voltages with high performance and high density micro processors for several microelectronic load applications. This paper proposes a DC-DC converter using variable on-time and variable switching frequency control enhanced constant ripple current control and reduced magnetic components. The proposed converter is realized by making the turn-offtime proportional to the on-time of the converter, according to the input and output voltage, thereby reducing the corresponding current ripple on output voltage in the continuous conduction mode. A Buck DC-DC converter using the proposed control strategy is analyzed in detail, along with some experimental results to show the performance and effectiveness of this converter. 展开更多
关键词 constant ripple current DC-DC converter variable switching frequency continuous conduction mode indirect currentsensor magnetic component.
下载PDF
An Adaptive Response Compensation Technique for the Constant-Current Hot-Wire Anemometer
10
作者 Soe Minn Khine Tomoya Houra Masato Tagawa 《Open Journal of Fluid Dynamics》 2013年第2期95-108,共14页
An adaptive response compensation technique has been proposed to compensate for the response lag of the constant-current hot-wire anemometer (CCA) by taking advantage of digital signal processing technology. First, we... An adaptive response compensation technique has been proposed to compensate for the response lag of the constant-current hot-wire anemometer (CCA) by taking advantage of digital signal processing technology. First, we have developed a simple response compensation scheme based on a precise theoretical expression for the frequency response of the CCA (Kaifuku et al. 2010, 2011), and verified its effectiveness experimentally for hot-wires of 5 μm, 10 μm and 20 μm in diameter. Then, another novel technique based on a two-sensor probe technique—originally developed for the response compensation of fine-wire thermocouples (Tagawa and Ohta 1997;Tagawa et al. 1998)—has been proposed for estimating thermal time-constants of hot-wires to realize the in-situ response compensation of the CCA. To demonstrate the usefulness of the CCA, we have applied the response compensation schemes to multipoint velocity measure- ment of a turbulent wake flow formed behind a circular cylinder by using a CCA probe consisting of 16 hot-wires, which were driven simultaneously by a very simple constant-current circuit. As a result, the proposed response compensation techniques for the CCA work quite successfully and are capable of improving the response speed of the CCA to obtain reliable measurements comparable to those by the commercially-available constant-temperature hot-wire anemometer (CTA). 展开更多
关键词 Flow Measurement HOT-WIRE ANEMOMETER Turbulent Flow constant-current HOT-WIRE ANEMOMETER Response COMPENSATION Frequency Response Time-constant Multipoint Measurement Digital Signal Processing
下载PDF
基于频率切换实现恒流/恒压输出的电场耦合无线电能传输系统 被引量:1
11
作者 苏玉刚 颜志琼 +3 位作者 胡宏晟 孙跃 刘哲 刘书柏杨 《中国电机工程学报》 EI CSCD 北大核心 2024年第4期1553-1564,I0025,共13页
电场耦合无线电能传输(electric-field coupled wireless power transfer,EC-WPT)技术的实际应用中,有些用电设备需要系统具有不同的恒定输出特性(恒流/恒压),即系统输出电压或输出电流与负载解耦,此外,系统还需具备在恒流、恒压模式间... 电场耦合无线电能传输(electric-field coupled wireless power transfer,EC-WPT)技术的实际应用中,有些用电设备需要系统具有不同的恒定输出特性(恒流/恒压),即系统输出电压或输出电流与负载解耦,此外,系统还需具备在恒流、恒压模式间按需切换的功能。针对该需求,基于LC-CLC谐振网络提出1种具有恒流/恒压输出特性的EC-WPT系统,分析LC-CLC谐振网络特性,推导恒流/恒压输出特性的实现条件以及恒流频率和恒压频率的计算方法,并给出系统参数设计方法,分析系统对工作频率的敏感性。最后通过仿真和实验验证所提出的EC-WPT系统恒流/恒压输出特性及其参数设计方法的正确性和有效性。实验结果表明所提出的系统在输入电压恒定的不同负载工况下分别实现2 A的恒流输出以及96 V的恒压输出,其最大传输效率分别为87.83%及88.17%。 展开更多
关键词 电场耦合无线电能传输系统 频率切换 恒流 恒压 谐振网络
下载PDF
恒流源三侧向电阻率测井模块研制及应用 被引量:1
12
作者 冯延强 刘富强 +2 位作者 布和 于怀远 邵帅 《世界核地质科学》 CAS 2024年第1期23-32,共10页
为进一步提高砂岩型铀矿地层电阻率参数在测井解释中的应用效果,尤其是对泥砂泥交互薄层的精细测量与识别,研究了基于OPA547放大器的恒流源三侧向电阻率测井模块,通过设计以OPA547为恒流激励源的数字激励控制电路,实现了正弦激励信号的... 为进一步提高砂岩型铀矿地层电阻率参数在测井解释中的应用效果,尤其是对泥砂泥交互薄层的精细测量与识别,研究了基于OPA547放大器的恒流源三侧向电阻率测井模块,通过设计以OPA547为恒流激励源的数字激励控制电路,实现了正弦激励信号的恒流输出;设计了正弦检测信号的恒流反馈电路,实现恒流源的负反馈稳定输出;设计了交流电压检测电路,实现了交流信号的低通滤波与信号半波整流;最后,在实验室利用标准刻度器进行了研制模块的系数刻度,且在砂岩型铀矿钻孔进行了实际测井应用对比。经对比分析,研制的恒流源三侧向电阻率测井模块能够与砂岩铀矿综合测井中的其他参数组合使用,输出激励电流可调,对岩性及岩性界面具有较高的识别能力,对于交互薄层、钙质夹层等地层岩性变化的响应显示明显。 展开更多
关键词 恒流源 三侧向电阻率 OPA547 地球物理测井
下载PDF
基于变频重构S/SP拓扑的无线电能传输系统恒流恒压研究
13
作者 李中启 张晨曦 +2 位作者 王建斌 王忠美 黄守道 《电工技术学报》 EI CSCD 北大核心 2024年第15期4718-4732,共15页
针对电动汽车无线充电系统耦合系数和负载变化导致系统输出电流和电压剧烈波动的问题,提出一种由交错叠放式线圈结构和变频重构控制策略组成的无线电能传输系统,通过重构补偿拓扑,并切换工作频率,实现了系统的恒流恒压输出。首先,分析... 针对电动汽车无线充电系统耦合系数和负载变化导致系统输出电流和电压剧烈波动的问题,提出一种由交错叠放式线圈结构和变频重构控制策略组成的无线电能传输系统,通过重构补偿拓扑,并切换工作频率,实现了系统的恒流恒压输出。首先,分析了拓扑重构前后系统的恒流、恒压输出特性和零相角特性,对比恒流恒压工作模式下补偿电容的大小,给出了系统参数调整方法。其次,剖析了交错叠放式线圈结构模型,提出基于耦合系数波动最小原则的线圈结构优化策略。所提出的系统补偿元件较少,两个工作频率点符合国际标准。最后,搭建一套500 W的实验样机,验证系统的可行性和有效性。实验结果表明,交错叠放式线圈在X轴方向偏移发射线圈外径的55%(187mm)或Y轴方向偏移120mm时,耦合系数波动率小于5%。系统在恒流模式下电流波动率为3.58%,在恒压模式下电压波动率为4.83%,满足无线充电系统恒流恒压需求。 展开更多
关键词 无线电能传输 变频重构 恒流 恒压 零相角
下载PDF
阴极防护下钢筋在模拟混凝土孔隙液中锈蚀的临界氯离子浓度
14
作者 李海洪 方翔 +1 位作者 陈昊翔 张东方 《腐蚀与防护》 CAS CSCD 北大核心 2024年第9期67-73,共7页
通过电位和电流变化和表面观测,并结合电化学阻抗谱,研究了恒电位和恒电流阴极防护下钢筋在模拟混凝土孔隙液(饱和氢氧化钙溶液)中发生锈蚀的临界氯离子浓度。结果表明:在10 mA/m^(2)电流密度阴极防护下,导致钢筋发生腐蚀的临界氯离子... 通过电位和电流变化和表面观测,并结合电化学阻抗谱,研究了恒电位和恒电流阴极防护下钢筋在模拟混凝土孔隙液(饱和氢氧化钙溶液)中发生锈蚀的临界氯离子浓度。结果表明:在10 mA/m^(2)电流密度阴极防护下,导致钢筋发生腐蚀的临界氯离子浓度为0.03 mol/L,这与无阴极防护状态下相同。当阴极防护电流足够大(大于10 mA/m^(2))时,钢筋在模拟孔隙液中未发生腐蚀,不存在临界氯离子浓度;在恒电位阴极防护欠防护状态下,随着保护电位的正移,钢筋发生腐蚀的临界氯离子浓度逐渐增大;当氯离子添加浓度超过临界氯离子浓度时,钢筋会发生溶解,这是由于钢筋局部腐蚀导致电位负于保护电位;基于结构物安全考虑,在模拟孔隙液中钢筋的阴极防护宜采用恒电流控制。 展开更多
关键词 阴极防护 恒电位 恒电流 临界氯离子浓度 钢筋
下载PDF
基于反激变换器的电池充电系统设计
15
作者 孙帅 付婷婷 宋小娜 《电池》 CAS 北大核心 2024年第4期537-541,共5页
以具有结构简单、电气隔离等优点的反激变换器为电池充电电源,分析反激变换器电路的连续和断续模式工作原理,通过设计电压电流双闭环控制方法,实现电池的恒流充电模式和恒电压充电模式,也可实现两种充电模式的切换。实验结果证明了反激... 以具有结构简单、电气隔离等优点的反激变换器为电池充电电源,分析反激变换器电路的连续和断续模式工作原理,通过设计电压电流双闭环控制方法,实现电池的恒流充电模式和恒电压充电模式,也可实现两种充电模式的切换。实验结果证明了反激变换器的连续工作模式和断续工作模式的正确性,验证了应用于电池充电电源的可行性和有效性,切换时间小于1 ms,电压波动小于1 V。 展开更多
关键词 直流(DC)-DC电路 反激变换器 连续模式 断续模式 电压电流双闭环 恒流充电 恒电压充电 电池充电系统
下载PDF
基于改进型ZVT Buck电路的IPT充电系统设计
16
作者 刘雪莉 徐睿 +3 位作者 李阳 汪学亮 寇苏雅 孟航 《天津工业大学学报》 CAS 北大核心 2024年第1期64-73,共10页
为了避免在感应式无线电能传输系统的耦合机构中增加多余的开关器件以及额外的无源元件,同时减小系统工作在高频率、大功率时全控型开关器件存在的开关损耗,提出基于改进型ZVT Buck电路闭环控制的方法实现对电池的恒流、恒压充电,通过... 为了避免在感应式无线电能传输系统的耦合机构中增加多余的开关器件以及额外的无源元件,同时减小系统工作在高频率、大功率时全控型开关器件存在的开关损耗,提出基于改进型ZVT Buck电路闭环控制的方法实现对电池的恒流、恒压充电,通过分析改进型ZVT Buck电路的工作模态以及对电路参数的设计,确保在整个充电过程中DC-DC变换器均工作在软开关状态,最后搭建充电电流为35 A、充电电压为370 V的实验平台验证该方法的可行性。结果表明:该方法控制简单,并且降低了系统电路结构的复杂度,传输效率相对较高,能够满足恒流恒压充电需求。 展开更多
关键词 感应式无线电能传输 改进型ZVT Buck电路 恒流恒压充电 软开关
下载PDF
液晶汽车仪表LED背光硬件电路分析与设计 被引量:1
17
作者 李菲 张晓荣 《内燃机与配件》 2024年第3期93-96,共4页
为了使液晶汽车仪表的背光灯在受到外界电气干扰的情况下能够保持稳定的输出电流、亮度不发生变化,对已使用的三种汽车仪表LED背光电路进行了研究和分析,提出了一种稳定性较高的硬件电路设计——仪表LED恒流源电路。该电路可通过调节精... 为了使液晶汽车仪表的背光灯在受到外界电气干扰的情况下能够保持稳定的输出电流、亮度不发生变化,对已使用的三种汽车仪表LED背光电路进行了研究和分析,提出了一种稳定性较高的硬件电路设计——仪表LED恒流源电路。该电路可通过调节精密电阻值来调节LED背光灯的亮度,设计方案简单、调整电流便捷、成本较低,在液晶汽车仪表市场中具有较高的应用价值。 展开更多
关键词 液晶汽车仪表 LED背光 瞬态抑制二极管 恒流源
下载PDF
半桥驱动的恒流恒压可重构的无线电能传输系统
18
作者 杨云虎 薛建志 +3 位作者 梁大壮 李钰 贾维娜 杨志 《电机与控制学报》 EI CSCD 北大核心 2024年第9期189-199,共11页
锂电池在充电过程中充电电压变化范围大,其等效阻抗不断增加,会带来恒流过充以及恒压欠充问题,结合锂电池在快速充电过程中的动态特性,提出一种基于半桥驱动的恒流恒压可重构的S/LCC-LCC无线电能传输(WPT)系统。半桥驱动的WPT系统仅用... 锂电池在充电过程中充电电压变化范围大,其等效阻抗不断增加,会带来恒流过充以及恒压欠充问题,结合锂电池在快速充电过程中的动态特性,提出一种基于半桥驱动的恒流恒压可重构的S/LCC-LCC无线电能传输(WPT)系统。半桥驱动的WPT系统仅用一个切换开关进行拓扑重构即可实现系统输出特性的切换,具有所用元件少,重构拓扑简单等特性。首先,给出了基于S/LCC-LCC的拓扑重构原理;其次,分析了半桥驱动的重构拓扑的恒流恒压以及零相角特性;再次,给出了WPT系统的异常工况以及相应解决办法;最后,搭建了仿真和实验平台。验证性的WPT系统在恒流模式能输出恒定电流3.47 A,在恒压模式能输出恒定电压48.2 V。仿真与实验结果验证了所提方法的正确性。 展开更多
关键词 半桥驱动 无线电能传输 恒流恒压 重构拓扑 零相角
下载PDF
基于恒流式热线风速仪的流速检测实训台设计
19
作者 苏燕 周恒超 《山东商业职业技术学院学报》 2024年第4期122-125,共4页
基于恒流式热线风速仪设计了可实现复杂表面的气流测量和湍流结构分析的流速检测实训台。实训台在基于单片机的硬件电路上创新设计,保证了较高的测量精度。可用于相关专业的教科研,同时也可用于学生自制热线式风速探针的校准,提高学生... 基于恒流式热线风速仪设计了可实现复杂表面的气流测量和湍流结构分析的流速检测实训台。实训台在基于单片机的硬件电路上创新设计,保证了较高的测量精度。可用于相关专业的教科研,同时也可用于学生自制热线式风速探针的校准,提高学生的动手操作能力,培养学生的学习兴趣。 展开更多
关键词 恒流式 流速检测 过热比 IPS触摸屏
下载PDF
基于自抗扰控制的圆纬机恒张力输纱控制系统设计
20
作者 彭来湖 谢国旺 戴宁 《纺织学报》 EI CAS CSCD 北大核心 2024年第1期211-219,共9页
针对当前圆纬机积极式送纱方式中存在的纱线张力及输送速度不可任意调节、纱线张力波动大等问题,提出了一种可为圆纬机输送恒定张力纱线的输纱控制系统。构建了以无刷直流电动机速度环为内环、以纱线张力为外环的纱线恒张力双闭环反馈... 针对当前圆纬机积极式送纱方式中存在的纱线张力及输送速度不可任意调节、纱线张力波动大等问题,提出了一种可为圆纬机输送恒定张力纱线的输纱控制系统。构建了以无刷直流电动机速度环为内环、以纱线张力为外环的纱线恒张力双闭环反馈控制系统,通过自抗扰控制技术获取纱线实时动态指标,并对无刷直流电动机目标转速进行调整,最后通过磁场定向控制技术驱动无刷直流电动机。详细阐述了纱线张力的形成机制、纱线恒张力输送控制方案、系统硬件设计及控制算法。输纱测试表明,该控制系统可实现多种类型纱线的恒定张力输送。其中,棉纱张力波动标准差为1.5 cN(300 m/min测试条件),氨纶包芯纱的张力波动标准差为0.33 cN(240 m/min测试条件)。输纱速度的调节范围为0~600 m/min,纱线张力的控制范围为2.0~50.0 cN。 展开更多
关键词 恒张力 输纱器 无刷直流电动机 磁场定向控制 自抗扰控制 圆纬机
下载PDF
上一页 1 2 151 下一页 到第
使用帮助 返回顶部