Distribution transformers operating in modern system grids or in industrial networks are subjected to many switching transients,which may occur due to routine operations,network reconfigurations or as reaction on prot...Distribution transformers operating in modern system grids or in industrial networks are subjected to many switching transients,which may occur due to routine operations,network reconfigurations or as reaction on protection signals.Depending on the network configuration and parameters,such events may lead to external overvoltages and result in additional stresses on the insulation system.This paper presents the influence of a series choke on damping of switching transients in distribution transformers.The impact of the choke is assessed by both amplitude and rise time reduction.The suppression of the transient rise time is shown for a test configuration involving distribution transformers connected to low loss cable lines and a medium voltage breaker.Such phenomena are especially typical for industrial networks where switching operations are very frequent.Both simulation and experiment results are given.Simulation results as well as measurement results confirmed that switching events can lead to high dU/dt and in consequence,can have adverse impacts on insulation system.Voltage escalation during switching event is strongly related with system conditions.The results obtained for presented mitigation method are promising and indicate significant dU/dt reduction as well as number of ignitions and voltage peak value.The protection of distribution transformers with a series choke is a new approach dedicated to environments prone to the occurrence of transients with high steepness.Experimental results show that the application of serial choke with suitable parameters realizes the reduction of dU/dt at the machines terminal from 24 kV/μs to 5 kV/μs,as well as the reduction of voltage peak value from 10 kV to 5 kV.The number of ignitions is also reduced.展开更多
A multi-gap and multi-channel gas switch with convexo-convex discal planet electrodes was designed and investigated. Eight gaps are formed in series by a trigger electrode, six intermediate electrodes and two high vol...A multi-gap and multi-channel gas switch with convexo-convex discal planet electrodes was designed and investigated. Eight gaps are formed in series by a trigger electrode, six intermediate electrodes and two high voltage electrodes with a uniform gap length of 5 ram. The self breakdown and triggered breakdown performance of the switch are reported. Both the delay time and jitter decrease with the increase in the trigger voltage, switching coefficient and the decrease in the trigger isolating resistor. The delay time of the switch is about 40 ns, and the jitter is less than 2 ns when charged with 4-85 kV and triggered by a voltage pule of -75 kV. The inductance of the switch is about 30 nH.展开更多
The trigger characteristics of a multi-gap gas switch with double insulating layers,a square-groove electrode supporter and a UV pre-ionizing structure are investigated aided by a high sensitivity fiber-bundle array d...The trigger characteristics of a multi-gap gas switch with double insulating layers,a square-groove electrode supporter and a UV pre-ionizing structure are investigated aided by a high sensitivity fiber-bundle array detector, a UV fiber detector, and a framing camera, in addition to standard electrical diagnostics. The fiber-bundle-array detector is used to track the turn-on sequence of each electrode gap at a timing precision of 0.6 ns. Each fiber bundle, including five fibers with different azimuth angles, aims at the whole emitting area of each electrode gap and is fed to a photomultiplier tube. The UV fiber detector with a spectrum response of 260-320 nm,including a fused-quartz fiber of 200 μm in diameter and a solar-blinded photomultiplier tube, is adopted to study the effect of UV pre-ionizing on trigger characteristics. The framing camera,with a capacity of 4 frames per shot and an exposure time of 5 ns, is employed to capture the evolution of channel arcs. Based on the turn-on light signal of each electrode gap, the breakdown delay is divided into statistical delay and formative delay. A decrease in both of them, a smaller switch jitter and more channel arcs are observed with lower gas pressure. An increase in trigger voltage can reduce the statistical delay and its jitter, while higher trigger voltage has a relatively small influence on the formative delay and the number of channel arcs. With the UV pre-ionizing structure at 0.24 MPa gas pressure and 60 kV trigger voltage, the statistical delay and its jitter can be reduced by 1.8 ns and 0.67 ns, while the formative delay and its jitter can only be reduced by 0.5 ns and 0.25 ns.展开更多
Grinding-induced tm phase transformation and the resultant texture in ceria-yttria-doped tetragonal zirconia polycrystals with varied tetragonality have been studied by XRD. It is observed that the reversible tm phase...Grinding-induced tm phase transformation and the resultant texture in ceria-yttria-doped tetragonal zirconia polycrystals with varied tetragonality have been studied by XRD. It is observed that the reversible tm phase transformation occurs during grinding and the intensity ratio of I(002)t/I(200)t increases with the transformability. The author proposes that the texture induced by grinding at low temperatures is due to the tetragonal variant reorientation via cyclic,reversible tm phase transformation, termed 'transformational domain switching', instead of the ferroelastic one展开更多
As a combination device for a step-up pulse transformer and a magnetic switch,the saturable pulse transformer is widely used in pulsed-power and plasma technology.A fractional-turn ratio saturable pulse transformer is...As a combination device for a step-up pulse transformer and a magnetic switch,the saturable pulse transformer is widely used in pulsed-power and plasma technology.A fractional-turn ratio saturable pulse transformer is constructed and analyzed in this paper.Preliminary experimental results show that if the primary energy storage capacitors are charged to 300 V,an output voltage of about 19 kV can be obtained across the capacitor connected to the secondary windings of a fractional-tum ratio saturable pulse transformer.Theoretical and experimental results reveal that this kind of pulse transformer is not only able to integrate a step-up transformer and a magnetic switch into one device,but can also lower the saturable inductance of its secondary windings,thus leading to the relatively high step-up ratio of the pulse transformer.Meanwhile,the application of the fractional-turn ratio saturable pulse transformer in a μs range pulse modulator as a voltage step-up device and main switch is also included in this paper.The demonstrated experiments display that an output voltage with an amplitude of about 29 kV,and a 1.6 μs pulse width can be obtained across a 3500 Ω resistive load,based on a pulse modulator,if the primary energy storage capacitors are charged to 300 V.This compact fractional-turn ratio saturable pulse transformer can be applied in many other fields such as surface treatment,corona plasma generation and dielectric barrier discharge.展开更多
Based on a quadratic transformation and a switching function,a novel multi-wing chaotic switched system is proposed.First,a 4-wing chaotic system is constructed from a 2-wing chaotic system on the basis of a quadratic...Based on a quadratic transformation and a switching function,a novel multi-wing chaotic switched system is proposed.First,a 4-wing chaotic system is constructed from a 2-wing chaotic system on the basis of a quadratic transformation.Then,a switching function is designed and by adjusting the switching function,the number and the distribution of the saddle-focus equilibrium points of the switched system can be regulated.Thus,a set of chaotic switched systems,which can produce 6-to-8-12-16-wing attractors,are generated.The Lyapunov exponent spectra,bifurcation diagrams,and Poincarémaps are given to verify the existence of the chaotic attractors.Besides,the digital circuit of the multi-wing chaotic switched system is designed by using the Verilog HDL fixed-point algorithm and the state machine control.Finally,the multi-wing chaotic attractors are demonstrated via FPGA platform.The experimental results show that the number of the wings of the chaotic attractors can be expanded more effectively with the combination of the quadratic transformation and the switching function methods.展开更多
The main purpose of the electrical power system is to transport and distribute energy generated by the central power plants in a safe and reliable manner to the customer premises. Most of the electrical equipment is e...The main purpose of the electrical power system is to transport and distribute energy generated by the central power plants in a safe and reliable manner to the customer premises. Most of the electrical equipment is exposed within the open which suggests they can be vulnerable to lightning strikes, road dwindling, windstorms, and a few engineering activities with the potential of causing different degrees of damage to the electrical equipment. One of the ways to guard the equipment is to deploy switching devices. However, the operations of most of these switching devices produce oscillatory transient in the electrical transmission and distribution systems which result in voltage, current, and frequency fluctuations in the load. This paper investigates the effect of switching devices on power quality and proposes a positive sequence voltage power transient suppression technique that can spontaneously improve the distorted voltage at the instant of capacitor switching using the capacitor line model as a case study. MATLAB/Simulink software was utilized for the analysis on an electrical network model with bus voltages of 69 kV/12.47 kV and 480 V. The results showed that, during switching operations, the positive sequence voltage power detector block produces ripple-free accurate results.展开更多
In 2001, CSR power supply system made a great progress. Three prototypes were designed for CSR quadruple and correct magnet. Three different companies provided the three prototypes, but the same circuit-chopper were e...In 2001, CSR power supply system made a great progress. Three prototypes were designed for CSR quadruple and correct magnet. Three different companies provided the three prototypes, but the same circuit-chopper were employed. The simplified diagram is showed in Fig.1. All pulsed switching power supply prototypes were tested successfully before the end of 2001.展开更多
A compact high-voltage repetitive nanosecond pulse generator(HRNPG)was developed for studying the technology of repetitive nanosecond pulse technology and its related application.The HRNPG mainly consists of a repetit...A compact high-voltage repetitive nanosecond pulse generator(HRNPG)was developed for studying the technology of repetitive nanosecond pulse technology and its related application.The HRNPG mainly consists of a repetitive charging module,a Tesla transformer and a sharpening switch.With its voltage lower than 1 kV,the primary repetitive charging circuit comprises two fast thyristors as its low-voltage switches.The spiral Tesla transformer acts as the main step-up component,and its peak transformation ratio is designed to be more than 100.A self-breakdown spark switch,i.e.the sharpening switch,is used to sharpen the output of the transformer and to generate nanosecond pulses.The HRNPG prototype is capable of generating pulses of 100 kV in peak with rise time 30 ns and the maximum repetition rate of 500 Hz on a 6 k load.Experimental results show,without any magnetic core,the developed Tesla transformer prototype can easily output high voltage while keeping itself small in size and light in weight,which is of significance for the compactness and portability of the pulse generator.The N2-insulated spark switch operated well at voltage close to 100 kV and the repetition rate within several hundreds of hertz.展开更多
This paper presents a novel method that is applied to realize the Linear Transformation(LT)Switched-Capacitor Filter(SCF).It adopts the Voltage Control Voltage Source(VCVS)equalized transfor-mation to revise the origi...This paper presents a novel method that is applied to realize the Linear Transformation(LT)Switched-Capacitor Filter(SCF).It adopts the Voltage Control Voltage Source(VCVS)equalized transfor-mation to revise the original LC ladder filter and induce it into 16 basic sections and then extend the princi-ple of the LT in order to fit active and 3 port networks and give out switched-capacitor circuits corre-sponding to the 16 basic sections,which can realize all four kinds of filters——LP,HP,BP,BS filters.De-signed examples are given here.An Nth order filter only requires N amplifiers and the circuit is insensitive toparasitic capacitances.The experimental results of a 3rd order elliptic LP and a 6th order elliptic BP are giv-en and agree with the theory.展开更多
快脉冲直线型变压器驱动源(fast linear transformer driver,FLTD)是建设下一代大型Z箍缩装置最有前景的技术路线之一。大型FLTD脉冲源中数以万计气体开关的可靠运行是提高Z箍缩装置可靠性的重要因素。该文基于15 MAZ箍缩科学实验装置的...快脉冲直线型变压器驱动源(fast linear transformer driver,FLTD)是建设下一代大型Z箍缩装置最有前景的技术路线之一。大型FLTD脉冲源中数以万计气体开关的可靠运行是提高Z箍缩装置可靠性的重要因素。该文基于15 MAZ箍缩科学实验装置的FLTD脉冲源设计,采用Monte-Carlo方法建立考虑支路开关自放电及其载荷共享效应的FLTD脉冲源可靠性计算模型,分析开关故障模式及其触发策略对脉冲源可靠性的影响。结果表明,主支路开关自放电产生的故障电压会引起开关级联自放电,降低装置可靠性。若主支路开关工作系数设定在0.5~0.7范围内,FLTD脉冲源故障率可低于1×10^(-4)。此外,触发器及触发支路开关的高可靠性对于提升脉冲源可靠性至关重要,增加触发器脉冲数量、降低触发器自放电故障率能够有效提升脉冲源可靠性,当触发器脉冲数量提升至4倍后,FLTD脉冲源故障率有望降低至1×10^(-5)以下。研究结果为大型FLTD脉冲源的开关工作系数及触发策略的选取提供参考,具有重要的工程应用价值。展开更多
文摘Distribution transformers operating in modern system grids or in industrial networks are subjected to many switching transients,which may occur due to routine operations,network reconfigurations or as reaction on protection signals.Depending on the network configuration and parameters,such events may lead to external overvoltages and result in additional stresses on the insulation system.This paper presents the influence of a series choke on damping of switching transients in distribution transformers.The impact of the choke is assessed by both amplitude and rise time reduction.The suppression of the transient rise time is shown for a test configuration involving distribution transformers connected to low loss cable lines and a medium voltage breaker.Such phenomena are especially typical for industrial networks where switching operations are very frequent.Both simulation and experiment results are given.Simulation results as well as measurement results confirmed that switching events can lead to high dU/dt and in consequence,can have adverse impacts on insulation system.Voltage escalation during switching event is strongly related with system conditions.The results obtained for presented mitigation method are promising and indicate significant dU/dt reduction as well as number of ignitions and voltage peak value.The protection of distribution transformers with a series choke is a new approach dedicated to environments prone to the occurrence of transients with high steepness.Experimental results show that the application of serial choke with suitable parameters realizes the reduction of dU/dt at the machines terminal from 24 kV/μs to 5 kV/μs,as well as the reduction of voltage peak value from 10 kV to 5 kV.The number of ignitions is also reduced.
基金supported by National Natural Science Foundation of China(Nos.50477019,50637010)the State Key Laboratory of Electrical Insulation and Power Equipment of China(EIPE.09207)
文摘A multi-gap and multi-channel gas switch with convexo-convex discal planet electrodes was designed and investigated. Eight gaps are formed in series by a trigger electrode, six intermediate electrodes and two high voltage electrodes with a uniform gap length of 5 ram. The self breakdown and triggered breakdown performance of the switch are reported. Both the delay time and jitter decrease with the increase in the trigger voltage, switching coefficient and the decrease in the trigger isolating resistor. The delay time of the switch is about 40 ns, and the jitter is less than 2 ns when charged with 4-85 kV and triggered by a voltage pule of -75 kV. The inductance of the switch is about 30 nH.
基金supported by National Natural Science Foundation of China(No.11105109)
文摘The trigger characteristics of a multi-gap gas switch with double insulating layers,a square-groove electrode supporter and a UV pre-ionizing structure are investigated aided by a high sensitivity fiber-bundle array detector, a UV fiber detector, and a framing camera, in addition to standard electrical diagnostics. The fiber-bundle-array detector is used to track the turn-on sequence of each electrode gap at a timing precision of 0.6 ns. Each fiber bundle, including five fibers with different azimuth angles, aims at the whole emitting area of each electrode gap and is fed to a photomultiplier tube. The UV fiber detector with a spectrum response of 260-320 nm,including a fused-quartz fiber of 200 μm in diameter and a solar-blinded photomultiplier tube, is adopted to study the effect of UV pre-ionizing on trigger characteristics. The framing camera,with a capacity of 4 frames per shot and an exposure time of 5 ns, is employed to capture the evolution of channel arcs. Based on the turn-on light signal of each electrode gap, the breakdown delay is divided into statistical delay and formative delay. A decrease in both of them, a smaller switch jitter and more channel arcs are observed with lower gas pressure. An increase in trigger voltage can reduce the statistical delay and its jitter, while higher trigger voltage has a relatively small influence on the formative delay and the number of channel arcs. With the UV pre-ionizing structure at 0.24 MPa gas pressure and 60 kV trigger voltage, the statistical delay and its jitter can be reduced by 1.8 ns and 0.67 ns, while the formative delay and its jitter can only be reduced by 0.5 ns and 0.25 ns.
文摘Grinding-induced tm phase transformation and the resultant texture in ceria-yttria-doped tetragonal zirconia polycrystals with varied tetragonality have been studied by XRD. It is observed that the reversible tm phase transformation occurs during grinding and the intensity ratio of I(002)t/I(200)t increases with the transformability. The author proposes that the texture induced by grinding at low temperatures is due to the tetragonal variant reorientation via cyclic,reversible tm phase transformation, termed 'transformational domain switching', instead of the ferroelastic one
基金supported by National Natural Science Foundation of China under Grant Nos.51477177 and 51641707
文摘As a combination device for a step-up pulse transformer and a magnetic switch,the saturable pulse transformer is widely used in pulsed-power and plasma technology.A fractional-turn ratio saturable pulse transformer is constructed and analyzed in this paper.Preliminary experimental results show that if the primary energy storage capacitors are charged to 300 V,an output voltage of about 19 kV can be obtained across the capacitor connected to the secondary windings of a fractional-tum ratio saturable pulse transformer.Theoretical and experimental results reveal that this kind of pulse transformer is not only able to integrate a step-up transformer and a magnetic switch into one device,but can also lower the saturable inductance of its secondary windings,thus leading to the relatively high step-up ratio of the pulse transformer.Meanwhile,the application of the fractional-turn ratio saturable pulse transformer in a μs range pulse modulator as a voltage step-up device and main switch is also included in this paper.The demonstrated experiments display that an output voltage with an amplitude of about 29 kV,and a 1.6 μs pulse width can be obtained across a 3500 Ω resistive load,based on a pulse modulator,if the primary energy storage capacitors are charged to 300 V.This compact fractional-turn ratio saturable pulse transformer can be applied in many other fields such as surface treatment,corona plasma generation and dielectric barrier discharge.
基金Project supported by the National Natural Science Foundation of China(Grant Nos.61973199 and 61973200)the Taishan Scholar Project of Shandong Province of China。
文摘Based on a quadratic transformation and a switching function,a novel multi-wing chaotic switched system is proposed.First,a 4-wing chaotic system is constructed from a 2-wing chaotic system on the basis of a quadratic transformation.Then,a switching function is designed and by adjusting the switching function,the number and the distribution of the saddle-focus equilibrium points of the switched system can be regulated.Thus,a set of chaotic switched systems,which can produce 6-to-8-12-16-wing attractors,are generated.The Lyapunov exponent spectra,bifurcation diagrams,and Poincarémaps are given to verify the existence of the chaotic attractors.Besides,the digital circuit of the multi-wing chaotic switched system is designed by using the Verilog HDL fixed-point algorithm and the state machine control.Finally,the multi-wing chaotic attractors are demonstrated via FPGA platform.The experimental results show that the number of the wings of the chaotic attractors can be expanded more effectively with the combination of the quadratic transformation and the switching function methods.
文摘The main purpose of the electrical power system is to transport and distribute energy generated by the central power plants in a safe and reliable manner to the customer premises. Most of the electrical equipment is exposed within the open which suggests they can be vulnerable to lightning strikes, road dwindling, windstorms, and a few engineering activities with the potential of causing different degrees of damage to the electrical equipment. One of the ways to guard the equipment is to deploy switching devices. However, the operations of most of these switching devices produce oscillatory transient in the electrical transmission and distribution systems which result in voltage, current, and frequency fluctuations in the load. This paper investigates the effect of switching devices on power quality and proposes a positive sequence voltage power transient suppression technique that can spontaneously improve the distorted voltage at the instant of capacitor switching using the capacitor line model as a case study. MATLAB/Simulink software was utilized for the analysis on an electrical network model with bus voltages of 69 kV/12.47 kV and 480 V. The results showed that, during switching operations, the positive sequence voltage power detector block produces ripple-free accurate results.
基金Supported by WTZ project of BMBF,German Government.
文摘In 2001, CSR power supply system made a great progress. Three prototypes were designed for CSR quadruple and correct magnet. Three different companies provided the three prototypes, but the same circuit-chopper were employed. The simplified diagram is showed in Fig.1. All pulsed switching power supply prototypes were tested successfully before the end of 2001.
基金Project supported by National Natural Science Foundation of China (51107049).
文摘A compact high-voltage repetitive nanosecond pulse generator(HRNPG)was developed for studying the technology of repetitive nanosecond pulse technology and its related application.The HRNPG mainly consists of a repetitive charging module,a Tesla transformer and a sharpening switch.With its voltage lower than 1 kV,the primary repetitive charging circuit comprises two fast thyristors as its low-voltage switches.The spiral Tesla transformer acts as the main step-up component,and its peak transformation ratio is designed to be more than 100.A self-breakdown spark switch,i.e.the sharpening switch,is used to sharpen the output of the transformer and to generate nanosecond pulses.The HRNPG prototype is capable of generating pulses of 100 kV in peak with rise time 30 ns and the maximum repetition rate of 500 Hz on a 6 k load.Experimental results show,without any magnetic core,the developed Tesla transformer prototype can easily output high voltage while keeping itself small in size and light in weight,which is of significance for the compactness and portability of the pulse generator.The N2-insulated spark switch operated well at voltage close to 100 kV and the repetition rate within several hundreds of hertz.
文摘This paper presents a novel method that is applied to realize the Linear Transformation(LT)Switched-Capacitor Filter(SCF).It adopts the Voltage Control Voltage Source(VCVS)equalized transfor-mation to revise the original LC ladder filter and induce it into 16 basic sections and then extend the princi-ple of the LT in order to fit active and 3 port networks and give out switched-capacitor circuits corre-sponding to the 16 basic sections,which can realize all four kinds of filters——LP,HP,BP,BS filters.De-signed examples are given here.An Nth order filter only requires N amplifiers and the circuit is insensitive toparasitic capacitances.The experimental results of a 3rd order elliptic LP and a 6th order elliptic BP are giv-en and agree with the theory.
文摘快脉冲直线型变压器驱动源(fast linear transformer driver,FLTD)是建设下一代大型Z箍缩装置最有前景的技术路线之一。大型FLTD脉冲源中数以万计气体开关的可靠运行是提高Z箍缩装置可靠性的重要因素。该文基于15 MAZ箍缩科学实验装置的FLTD脉冲源设计,采用Monte-Carlo方法建立考虑支路开关自放电及其载荷共享效应的FLTD脉冲源可靠性计算模型,分析开关故障模式及其触发策略对脉冲源可靠性的影响。结果表明,主支路开关自放电产生的故障电压会引起开关级联自放电,降低装置可靠性。若主支路开关工作系数设定在0.5~0.7范围内,FLTD脉冲源故障率可低于1×10^(-4)。此外,触发器及触发支路开关的高可靠性对于提升脉冲源可靠性至关重要,增加触发器脉冲数量、降低触发器自放电故障率能够有效提升脉冲源可靠性,当触发器脉冲数量提升至4倍后,FLTD脉冲源故障率有望降低至1×10^(-5)以下。研究结果为大型FLTD脉冲源的开关工作系数及触发策略的选取提供参考,具有重要的工程应用价值。