In this paper, we have studied several classes of planar piecewise Hamiltonian systems with three zones separated by two parallel straight lines. Firstly, we give the maximal number of limit cycles in these classes of...In this paper, we have studied several classes of planar piecewise Hamiltonian systems with three zones separated by two parallel straight lines. Firstly, we give the maximal number of limit cycles in these classes of systems with a center in two zones and without equilibrium points in the other zone (or with a center in one zone and without equilibrium points in the other zones). In addition, we also give examples to illustrate that it can reach the maximal number.展开更多
Cyber physical systems(CPS) recently emerge as a new technology which can provide promising approaches to demand side management(DSM), an important capability in industrial power systems. Meanwhile, the manufactur...Cyber physical systems(CPS) recently emerge as a new technology which can provide promising approaches to demand side management(DSM), an important capability in industrial power systems. Meanwhile, the manufacturing center is a typical industrial power subsystem with dozens of high energy consumption devices which have complex physical dynamics. DSM, integrated with CPS, is an effective methodology for solving energy optimization problems in manufacturing center. This paper presents a prediction-based manufacturing center self-adaptive energy optimization method for demand side management in cyber physical systems. To gain prior knowledge of DSM operating results, a sparse Bayesian learning based componential forecasting method is introduced to predict 24-hour electric load levels for specific industrial areas in China. From this data, a pricing strategy is designed based on short-term load forecasting results. To minimize total energy costs while guaranteeing manufacturing center service quality, an adaptive demand side energy optimization algorithm is presented. The proposed scheme is tested in a machining center energy optimization experiment. An AMI sensing system is then used to measure the demand side energy consumption of the manufacturing center. Based on the data collected from the sensing system, the load prediction-based energy optimization scheme is implemented. By employing both the PSO and the CPSO method, the problem of DSM in the manufac^ring center is solved. The results of the experiment show the self-adaptive CPSO energy optimization method enhances optimization by 5% compared with the traditional PSO optimization method.展开更多
In this paper we deal with a cubic near-Hamiltonian system whose unperturbed system is a simple cubic Hamiltonian system having a nilpotent center. We prove that the system can have 5 limit cycles by using bifurcation...In this paper we deal with a cubic near-Hamiltonian system whose unperturbed system is a simple cubic Hamiltonian system having a nilpotent center. We prove that the system can have 5 limit cycles by using bifurcation theory.展开更多
This paper presents the results of a parametric study of self-centering seismic retrofit schemes for reinforced concrete (RC) frame buildings. The self-centering retrofit system features flag-shaped hysteresis and min...This paper presents the results of a parametric study of self-centering seismic retrofit schemes for reinforced concrete (RC) frame buildings. The self-centering retrofit system features flag-shaped hysteresis and minimal residual deformation. For comparison purpose,an alternate seismic retrofit scheme that uses a bilinear-hysteresis retrofit system such as buckling-restrained braces (BRB) is also considered in this paper. The parametric study was carried out in a single-degree-of-freedom (SDOF) system framework since a multi-story building structure may be idealized as an equivalent SDOF system and investigation of the performance of this equivalent SDOF system can provide insight into the seismic response of the multi-story building. A peak-oriented hysteresis model which can consider the strength and stiffness degradation is used to describe the hysteretic behavior of RC structures. The parametric study involves two key parameters -the strength ratio and elastic stiffness ratio between the seismic retrofit system and the original RC frame. An ensemble of 172 earthquake ground motion records scaled to the design basis earthquake in California with a probability of exceedance of 10% in 50 years was constructed for the simulation-based parametric study. The effectiveness of the two seismic retrofit schemes considered in this study is evaluated in terms of peak displacement ratio,peak acceleration ratio,energy dissipation demand ratio and residual displacement ratio between the SDOF systems with and without retrofit. It is found from this parametric study that RC structures retrofitted with the self-centering retrofit scheme (SCRS) can achieve a seismic performance level comparable to the bilinear-hysteresis retrofit scheme (BHRS) in terms of peak displacement and energy dissipation demand ratio while having negligible residual displacement after earthquake.展开更多
The volumetric flow rate of smoke generated from the fire in large space often reaches to hundreds of thousands CMH because of extended floor height and as it’s more difficult to isolate the smoke to the limited area...The volumetric flow rate of smoke generated from the fire in large space often reaches to hundreds of thousands CMH because of extended floor height and as it’s more difficult to isolate the smoke to the limited area, comparing to normal-scale building, design and operation of effective smoke control system for large space is more than important. In this study, with the analysis model for such a large space as exhibition hall or conference room in conventional center, design of mechanical smoke exhaust system was conducted based on currently-available design standard which was then followed by numerical analysis of the design using 3D numerical analysis method. For conference room at 2.0 MW heat release rate, 99,173 CMH flow rate is required, if smoke layer is maintained at 60% of the floor height and for exhibition hall at 8.8 MW with 80% of floor height, flow rate required is 219,802 CMH, which are incorporated into the design. In view of 3D numerical analysis, accuracy of the design according to algebraic expression is sufficient.展开更多
To provide scientific management basis for the garden planning, project construction, maintenance, social service, this paper prompted that the urban gardening administration sectors need to construct gardening inform...To provide scientific management basis for the garden planning, project construction, maintenance, social service, this paper prompted that the urban gardening administration sectors need to construct gardening information management system. On the basis of fully requirements analysis of gardening sectors, this paper discussed the key technology for system construction. It also proposed to flexibly and smartly build up the system by using the secondary development design environment and running environment based on data center integration development platform. This system greatly helps the daily management and plays very important role in improving urban ecological environment and investment environment.展开更多
Based on the theory of multi-body system (MBS), bine’s and huston’s methods are applied to an on-line measuring system of machining center in this paper. Through the study on modeling technique, the comprehensive mo...Based on the theory of multi-body system (MBS), bine’s and huston’s methods are applied to an on-line measuring system of machining center in this paper. Through the study on modeling technique, the comprehensive model for errors calculation in an on-line measuring System of machining center have been built for the first time. Using this model, the errors can be compensated by soft.ware and the measuring accuracy can be enhanced without any more inveSt. This model can be used in all kinds of machining center.展开更多
According to the subjectivity and fuzziness of analysis on failure mode severity about spindle system of machining center,an analysis model of the failure mode severity of such a system is proposed based on the new fa...According to the subjectivity and fuzziness of analysis on failure mode severity about spindle system of machining center,an analysis model of the failure mode severity of such a system is proposed based on the new fault severity index system, improved analytic hierarchy process( IAHP) and entropy-based fuzzy comprehensive evaluation. IAHP and entropy methods are adopted to determine the comprehensive failure severity index weight. The evaluation result is obtained after the factor set,comment set,weight set,and other parameters are determined,and then the level of risk degree and numerical value order of every spindle system failure mode is given. By taking an example,we verify that the proposed method can quantify the qualitative problem comprehensively,obtain more accurate analysis results,and provide the theoretical reference for mechanization and sequencing of failure mode effect analysis in reliability analysis. The calculation results can also serve as the basis of failure mode,effects,and criticality analysis in the subsequent step.展开更多
Abstract The authors consider the nonlinear systems [AKx·D6]=h(y)-F(x),=-g(x) in which g(x) may be not differentiable and the system can be nonsymmetric. Some conditions which ensure that there exists an...Abstract The authors consider the nonlinear systems [AKx·D6]=h(y)-F(x),=-g(x) in which g(x) may be not differentiable and the system can be nonsymmetric. Some conditions which ensure that there exists an infinite number of limit cycles are obtained. A problem about center focus put forward by R. Conti has been answered.展开更多
The center conditions and bifurcation of limit cycles for a class of fifth degree systems are investigated.Two recursive formulas to compute singular quantities at infinity and at the origin are given.The first nine ...The center conditions and bifurcation of limit cycles for a class of fifth degree systems are investigated.Two recursive formulas to compute singular quantities at infinity and at the origin are given.The first nine singular point quantities at infinity and first seven singular point quantities at the origin for the system are given in order to get center conditions and study bifurcation of limit cycles.Two fifth degree systems are constructed.One allows the appearance of eight limit cycles in the neighborhood of infinity,which is the first example that a polynomial differential system bifurcates eight limit cycles at infinity.The other perturbs six limit cycles at the origin.展开更多
Agricultural irrigation is a primary user for freshwater withdrawal. Irrigation plays an important role in crop production, as it provides the benefit of reducing the effects of prolonged dryness and erratic precipita...Agricultural irrigation is a primary user for freshwater withdrawal. Irrigation plays an important role in crop production, as it provides the benefit of reducing the effects of prolonged dryness and erratic precipitation. Center pivot irrigation system is the most common irrigation system in agriculture. As the center pivot irrigation system ages, the system could develop a leaking joint, clogged sprinklers, and physical damage. This can cause areas of non-uniformity that can lead to under- or over-irrigated in some areas of the land, resulting in excess energy use and cost, wasting resources, and environmental impacts. Thus, it is important to evaluate the performance of a center pivot irrigation system regularly to maximize return on investments and minimize wasting resources. This study focuses on evaluating the impacts and benefits of improved center pivot irrigation distribution uniformity by performing distribution uniformity evaluations pre- and post-retrofit. This study also focused on demonstrating an unmanned aerial vehicle (UAV) to assess the performance of the center pivot irrigation system in two irrigated farmlands. The Coefficient of Uniformity (CU), Distribution Uniformity (DU), and Scheduling Coefficient (SC) were calculated based on the catch can test data. The values were utilized to evaluate water and energy savings from the improved coefficients. The team has found that replacing sprinkler packages increased the CU from 78 to 89 and the DU from 77 to 82, and reduced the SC from 1.3 to 1.2 in Field A. In Field B, replacing sprinkler packages increased the CU from 73 to 91 and the DU from 62 to 84 and reduced the SC from 1.6 to 1.2. The estimated water savings in Field A due to the reduced scheduling coefficient was approximately 151,000 liters/hectare/year, with consideration of the corn and soybean rotation field in Michigan. The estimated water savings in Field B was 608,000 liters/hectare/year. The data from this demonstration study showed the value of distribution uniformity evaluation and retrofit of irrigation systems. This information will encourage farmers and agricultural industries to consider performing more distribution uniformity evaluations, ultimately improving irrigation water use efficiency and supporting sustainable water management in agriculture.展开更多
文摘In this paper, we have studied several classes of planar piecewise Hamiltonian systems with three zones separated by two parallel straight lines. Firstly, we give the maximal number of limit cycles in these classes of systems with a center in two zones and without equilibrium points in the other zone (or with a center in one zone and without equilibrium points in the other zones). In addition, we also give examples to illustrate that it can reach the maximal number.
基金Supported by National Natural Science Foundation of China(Grant No.61272428)PhD Programs Foundation of Ministry of Education of China(Grant No.20120002110067)
文摘Cyber physical systems(CPS) recently emerge as a new technology which can provide promising approaches to demand side management(DSM), an important capability in industrial power systems. Meanwhile, the manufacturing center is a typical industrial power subsystem with dozens of high energy consumption devices which have complex physical dynamics. DSM, integrated with CPS, is an effective methodology for solving energy optimization problems in manufacturing center. This paper presents a prediction-based manufacturing center self-adaptive energy optimization method for demand side management in cyber physical systems. To gain prior knowledge of DSM operating results, a sparse Bayesian learning based componential forecasting method is introduced to predict 24-hour electric load levels for specific industrial areas in China. From this data, a pricing strategy is designed based on short-term load forecasting results. To minimize total energy costs while guaranteeing manufacturing center service quality, an adaptive demand side energy optimization algorithm is presented. The proposed scheme is tested in a machining center energy optimization experiment. An AMI sensing system is then used to measure the demand side energy consumption of the manufacturing center. Based on the data collected from the sensing system, the load prediction-based energy optimization scheme is implemented. By employing both the PSO and the CPSO method, the problem of DSM in the manufac^ring center is solved. The results of the experiment show the self-adaptive CPSO energy optimization method enhances optimization by 5% compared with the traditional PSO optimization method.
文摘In this paper we deal with a cubic near-Hamiltonian system whose unperturbed system is a simple cubic Hamiltonian system having a nilpotent center. We prove that the system can have 5 limit cycles by using bifurcation theory.
基金Univeristy of Maryland,Start-up Grant to the First Author
文摘This paper presents the results of a parametric study of self-centering seismic retrofit schemes for reinforced concrete (RC) frame buildings. The self-centering retrofit system features flag-shaped hysteresis and minimal residual deformation. For comparison purpose,an alternate seismic retrofit scheme that uses a bilinear-hysteresis retrofit system such as buckling-restrained braces (BRB) is also considered in this paper. The parametric study was carried out in a single-degree-of-freedom (SDOF) system framework since a multi-story building structure may be idealized as an equivalent SDOF system and investigation of the performance of this equivalent SDOF system can provide insight into the seismic response of the multi-story building. A peak-oriented hysteresis model which can consider the strength and stiffness degradation is used to describe the hysteretic behavior of RC structures. The parametric study involves two key parameters -the strength ratio and elastic stiffness ratio between the seismic retrofit system and the original RC frame. An ensemble of 172 earthquake ground motion records scaled to the design basis earthquake in California with a probability of exceedance of 10% in 50 years was constructed for the simulation-based parametric study. The effectiveness of the two seismic retrofit schemes considered in this study is evaluated in terms of peak displacement ratio,peak acceleration ratio,energy dissipation demand ratio and residual displacement ratio between the SDOF systems with and without retrofit. It is found from this parametric study that RC structures retrofitted with the self-centering retrofit scheme (SCRS) can achieve a seismic performance level comparable to the bilinear-hysteresis retrofit scheme (BHRS) in terms of peak displacement and energy dissipation demand ratio while having negligible residual displacement after earthquake.
文摘The volumetric flow rate of smoke generated from the fire in large space often reaches to hundreds of thousands CMH because of extended floor height and as it’s more difficult to isolate the smoke to the limited area, comparing to normal-scale building, design and operation of effective smoke control system for large space is more than important. In this study, with the analysis model for such a large space as exhibition hall or conference room in conventional center, design of mechanical smoke exhaust system was conducted based on currently-available design standard which was then followed by numerical analysis of the design using 3D numerical analysis method. For conference room at 2.0 MW heat release rate, 99,173 CMH flow rate is required, if smoke layer is maintained at 60% of the floor height and for exhibition hall at 8.8 MW with 80% of floor height, flow rate required is 219,802 CMH, which are incorporated into the design. In view of 3D numerical analysis, accuracy of the design according to algebraic expression is sufficient.
文摘To provide scientific management basis for the garden planning, project construction, maintenance, social service, this paper prompted that the urban gardening administration sectors need to construct gardening information management system. On the basis of fully requirements analysis of gardening sectors, this paper discussed the key technology for system construction. It also proposed to flexibly and smartly build up the system by using the secondary development design environment and running environment based on data center integration development platform. This system greatly helps the daily management and plays very important role in improving urban ecological environment and investment environment.
文摘Based on the theory of multi-body system (MBS), bine’s and huston’s methods are applied to an on-line measuring system of machining center in this paper. Through the study on modeling technique, the comprehensive model for errors calculation in an on-line measuring System of machining center have been built for the first time. Using this model, the errors can be compensated by soft.ware and the measuring accuracy can be enhanced without any more inveSt. This model can be used in all kinds of machining center.
基金Sponsored by the National Natural Science Foundation of China(Grant No.51275205)
文摘According to the subjectivity and fuzziness of analysis on failure mode severity about spindle system of machining center,an analysis model of the failure mode severity of such a system is proposed based on the new fault severity index system, improved analytic hierarchy process( IAHP) and entropy-based fuzzy comprehensive evaluation. IAHP and entropy methods are adopted to determine the comprehensive failure severity index weight. The evaluation result is obtained after the factor set,comment set,weight set,and other parameters are determined,and then the level of risk degree and numerical value order of every spindle system failure mode is given. By taking an example,we verify that the proposed method can quantify the qualitative problem comprehensively,obtain more accurate analysis results,and provide the theoretical reference for mechanization and sequencing of failure mode effect analysis in reliability analysis. The calculation results can also serve as the basis of failure mode,effects,and criticality analysis in the subsequent step.
文摘Abstract The authors consider the nonlinear systems [AKx·D6]=h(y)-F(x),=-g(x) in which g(x) may be not differentiable and the system can be nonsymmetric. Some conditions which ensure that there exists an infinite number of limit cycles are obtained. A problem about center focus put forward by R. Conti has been answered.
基金Supported by Science Fund of the Education Departmentof Guangxi province( 2 0 0 3) and the NationalNatural Science Foundation of China( 1 0 361 0 0 3)
文摘The center conditions and bifurcation of limit cycles for a class of fifth degree systems are investigated.Two recursive formulas to compute singular quantities at infinity and at the origin are given.The first nine singular point quantities at infinity and first seven singular point quantities at the origin for the system are given in order to get center conditions and study bifurcation of limit cycles.Two fifth degree systems are constructed.One allows the appearance of eight limit cycles in the neighborhood of infinity,which is the first example that a polynomial differential system bifurcates eight limit cycles at infinity.The other perturbs six limit cycles at the origin.
文摘Agricultural irrigation is a primary user for freshwater withdrawal. Irrigation plays an important role in crop production, as it provides the benefit of reducing the effects of prolonged dryness and erratic precipitation. Center pivot irrigation system is the most common irrigation system in agriculture. As the center pivot irrigation system ages, the system could develop a leaking joint, clogged sprinklers, and physical damage. This can cause areas of non-uniformity that can lead to under- or over-irrigated in some areas of the land, resulting in excess energy use and cost, wasting resources, and environmental impacts. Thus, it is important to evaluate the performance of a center pivot irrigation system regularly to maximize return on investments and minimize wasting resources. This study focuses on evaluating the impacts and benefits of improved center pivot irrigation distribution uniformity by performing distribution uniformity evaluations pre- and post-retrofit. This study also focused on demonstrating an unmanned aerial vehicle (UAV) to assess the performance of the center pivot irrigation system in two irrigated farmlands. The Coefficient of Uniformity (CU), Distribution Uniformity (DU), and Scheduling Coefficient (SC) were calculated based on the catch can test data. The values were utilized to evaluate water and energy savings from the improved coefficients. The team has found that replacing sprinkler packages increased the CU from 78 to 89 and the DU from 77 to 82, and reduced the SC from 1.3 to 1.2 in Field A. In Field B, replacing sprinkler packages increased the CU from 73 to 91 and the DU from 62 to 84 and reduced the SC from 1.6 to 1.2. The estimated water savings in Field A due to the reduced scheduling coefficient was approximately 151,000 liters/hectare/year, with consideration of the corn and soybean rotation field in Michigan. The estimated water savings in Field B was 608,000 liters/hectare/year. The data from this demonstration study showed the value of distribution uniformity evaluation and retrofit of irrigation systems. This information will encourage farmers and agricultural industries to consider performing more distribution uniformity evaluations, ultimately improving irrigation water use efficiency and supporting sustainable water management in agriculture.