In semiconductor and electronics factories, large multi-chiller systems are needed to satisfy strict cooling load requirements. In order to save energy, it is worthwhile to design the chilled water system operation. I...In semiconductor and electronics factories, large multi-chiller systems are needed to satisfy strict cooling load requirements. In order to save energy, it is worthwhile to design the chilled water system operation. In this paper, an optimal flexible operation scheme is developed based on a two-dimensional time-series model to forecast the cooling load of multi-chiller systems with chiller units of different cooling capacities running in parallel. The optimal integrity scheme can be obtained using the Mixed Integer Nonlinear Programming method, which minimizes the energy consumption of the system within a future time period. In order to better adapt the change of cooling load, the operation strategy of regulating the chilled water flowrates is employed. The chilled water flowrates are set as a design variable. When the chillers are running, their chilled water flowrates can vary within limits, whereas the flowrates are zero when the chillers are unloaded. This forecasting method provides integral optimization within a future time period and offers the operating reference for operators. The power and advantages of the proposed method are presented using an industrial case to help readers delve into this matter.展开更多
Recently, if you look at the trend of the Unmanned Combat Entities (UCE) on the world that are actually operational, a large number of personnel per one UCE has been operating the GCS. However, UCEs to perform the att...Recently, if you look at the trend of the Unmanned Combat Entities (UCE) on the world that are actually operational, a large number of personnel per one UCE has been operating the GCS. However, UCEs to perform the attack/reconnaissance mission are very expensive assets and require a considerable amount of time to train for UCE operations. Accordingly, the future battlefield environment has become important to develop multiple UCE ground control station. In this study, we developed a multiple UCE GCS that one operator can operate up to four UCEs. The software was built with a total of 6 displays using a Lockheed Martin Corporation’s prepar3D. Scenario of research takes into account the operation of the South Korea-type future multiple UCEs, to take advantage of the simulation system, in this paper, we propose for each of the concepts and technologies.展开更多
为研究兆瓦级高效紧凑型核动力系统的运行特性,使用自主开发的热管堆瞬态分析程序TAPIRS(Transient Analysis code for heat Pipe and AMTEC power conversion space Reactor power System)和超临界二氧化碳布雷顿循环的瞬态分析程序SCT...为研究兆瓦级高效紧凑型核动力系统的运行特性,使用自主开发的热管堆瞬态分析程序TAPIRS(Transient Analysis code for heat Pipe and AMTEC power conversion space Reactor power System)和超临界二氧化碳布雷顿循环的瞬态分析程序SCTRAN/CO_(2)(Super Critical reactors Transient Analysis code/Carbon Dioxide)的耦合程序对其反应性、负荷、冷却水温度和流量等扰动进行了开环动态响应分析,并据此进行了控制系统设计。在此基础上,对线性变负荷、阶梯式变负荷以及甩负荷这三种变负荷运行工况进行了计算分析。结果表明:该核动力系统的转速对扰动的变化较为敏感,需要加以控制;低负荷下旁通会使压缩机流量上升,需对压缩机流量加以控制;系统在控制方案下能以6%FP(Full Power)·min^(−1)的速度实现0%~100%的负荷变动,且可以在任意负荷水平下运行;甩负荷下系统的波动时间变长,但是仍可达到新的稳态进行工作,且各参数处于安全范围内。本研究可为新型核动力系统的概念设计提供参考。展开更多
文摘In semiconductor and electronics factories, large multi-chiller systems are needed to satisfy strict cooling load requirements. In order to save energy, it is worthwhile to design the chilled water system operation. In this paper, an optimal flexible operation scheme is developed based on a two-dimensional time-series model to forecast the cooling load of multi-chiller systems with chiller units of different cooling capacities running in parallel. The optimal integrity scheme can be obtained using the Mixed Integer Nonlinear Programming method, which minimizes the energy consumption of the system within a future time period. In order to better adapt the change of cooling load, the operation strategy of regulating the chilled water flowrates is employed. The chilled water flowrates are set as a design variable. When the chillers are running, their chilled water flowrates can vary within limits, whereas the flowrates are zero when the chillers are unloaded. This forecasting method provides integral optimization within a future time period and offers the operating reference for operators. The power and advantages of the proposed method are presented using an industrial case to help readers delve into this matter.
文摘Recently, if you look at the trend of the Unmanned Combat Entities (UCE) on the world that are actually operational, a large number of personnel per one UCE has been operating the GCS. However, UCEs to perform the attack/reconnaissance mission are very expensive assets and require a considerable amount of time to train for UCE operations. Accordingly, the future battlefield environment has become important to develop multiple UCE ground control station. In this study, we developed a multiple UCE GCS that one operator can operate up to four UCEs. The software was built with a total of 6 displays using a Lockheed Martin Corporation’s prepar3D. Scenario of research takes into account the operation of the South Korea-type future multiple UCEs, to take advantage of the simulation system, in this paper, we propose for each of the concepts and technologies.
文摘为研究兆瓦级高效紧凑型核动力系统的运行特性,使用自主开发的热管堆瞬态分析程序TAPIRS(Transient Analysis code for heat Pipe and AMTEC power conversion space Reactor power System)和超临界二氧化碳布雷顿循环的瞬态分析程序SCTRAN/CO_(2)(Super Critical reactors Transient Analysis code/Carbon Dioxide)的耦合程序对其反应性、负荷、冷却水温度和流量等扰动进行了开环动态响应分析,并据此进行了控制系统设计。在此基础上,对线性变负荷、阶梯式变负荷以及甩负荷这三种变负荷运行工况进行了计算分析。结果表明:该核动力系统的转速对扰动的变化较为敏感,需要加以控制;低负荷下旁通会使压缩机流量上升,需对压缩机流量加以控制;系统在控制方案下能以6%FP(Full Power)·min^(−1)的速度实现0%~100%的负荷变动,且可以在任意负荷水平下运行;甩负荷下系统的波动时间变长,但是仍可达到新的稳态进行工作,且各参数处于安全范围内。本研究可为新型核动力系统的概念设计提供参考。