期刊文献+
共找到7篇文章
< 1 >
每页显示 20 50 100
Exploiting demand-side heterogeneous flexible resources in risk management of power system frequency
1
作者 YAO Yu SONG YongHua +2 位作者 YE ChengJin DING Yi ZHAO YuMing 《Science China(Technological Sciences)》 SCIE EI CAS CSCD 2024年第5期1612-1627,共16页
More demand-side flexible resources(DFRs)are participating in the frequency regulation of renewable power systems,whose heterogeneous characteristics have a significant impact on the system frequency response.Conseque... More demand-side flexible resources(DFRs)are participating in the frequency regulation of renewable power systems,whose heterogeneous characteristics have a significant impact on the system frequency response.Consequently,selecting suitable DFRs poses a formidable challenge for independent system operators(ISO).In this paper,a reserve allocation methodology for heterogeneous DFRs is proposed to manage the risk of power system frequency.Firstly,a performance curve is developed to describe the cost,capacity,and response speed of DFRs.Moreover,a clustering method for multiple distributed DFRs is conducted to calculate the aggregated performance curves and uncertainty coefficients.Then,the frequency security criterion considering DFRs’performance is constructed,whose linearity makes it can be easily coupled into the system scheduling model and solved.Furthermore,a risk management model for DFRs considering frequency-chance-constraint is proposed to make a trade-off between cost and frequency security.Finally,the model is transformed into mixed integer second-order cone programming(MISOCP)and solved by the commercial solver.The proposed model is validated by the IEEE 30 and IEEE 118 bus systems. 展开更多
关键词 demand-side heterogenous flexible resources risk management of power system frequency performance curve aggregation method mixed integer second-order cone programming
原文传递
Decentralized Primary Frequency Regulation for Hybrid Multi-terminal Direct Current Power Systems Considering Multi-source Enhancement
2
作者 Jialiang Wu Zhen Wang +2 位作者 Ruixu Liu Yu Shan Chenxuan Wang 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2024年第3期958-970,共13页
Hybrid multi-terminal direct current(MTDC)transmission technology has been a research focus,and primary frequency regulation(FR)improvement in the receiving-end system is one of the problems to be solved.This paper pr... Hybrid multi-terminal direct current(MTDC)transmission technology has been a research focus,and primary frequency regulation(FR)improvement in the receiving-end system is one of the problems to be solved.This paper presents a decentralized primary FR scheme for hybrid MTDC power systems considering multi-source enhancement to help suppress frequency disturbance in the receiving-end systems.All the converters only need local frequency or DC voltage signal input to respond to system disturbance without communication or a control center,i.e.,a decentralized control scheme.The proposed scheme can activate appropriate power sources to assist in FR in various system disturbance severities with fine-designed thresholds,ensuring sufficient utilization of each power source.To better balance FR performance and FR resource participation,an evaluation index is proposed and the parameter optimization problem is further conducted.Finally,the validity of the proposed scheme is verified by simulations in MATLAB/Simulink. 展开更多
关键词 Decentralized control scheme primary frequency regulation(FR) rate of change of frequency(ROCOF) system frequency disturbance
原文传递
CALCULATIONS OF THE INNER DISTURBANCE FREQUENCIES INSIDE THE EPICYCLIC GEARING
3
作者 Sun Jinghui,Gu DiminHarbin University of Architecture and Engineering 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 1995年第2期142-148,共7页
The forms of the vibration disturbances inside the epicyclic gear train are analyzed. Thefrequency equations for the inner disturbances of the epicyclic gearing with one or two degrees offreedom have been built. The l... The forms of the vibration disturbances inside the epicyclic gear train are analyzed. Thefrequency equations for the inner disturbances of the epicyclic gearing with one or two degrees offreedom have been built. The latter of them is a 3-dimension problem and the range of the disturbance frequencies covers a series of planes inside the 3-dimension coordinates. As a result, thechances to lead to the system resonance are developed. The calculating results indicate that in thedesign process of the shaft system, the chances of resonance can be reduced by tunning the dynamicparameters and the structure of the system. 展开更多
关键词 Epicyclic gear train Shaft system frequency / disturbance
下载PDF
Flash Process-Based Complex Programmable Logical Device with 72 Macro Cells
4
作者 Wen-Chang Li Ping Li Wei Li 《Journal of Electronic Science and Technology of China》 2007年第4期332-335,共4页
A complex programmable logical device (CPLD) based on conventional embedded Flash memory process with 72 macro cells is studied in the paper. Compared with the Flash cell array technology employed by foreign compani... A complex programmable logical device (CPLD) based on conventional embedded Flash memory process with 72 macro cells is studied in the paper. Compared with the Flash cell array technology employed by foreign companies, this architecture exhibiting insystem reconfiguration and rapid response was manufactured by low cost fabrication process. The device architecture and critical cell design are also analyzed in detail in the paper. The CPLD was designed by full-custom ASIC technology and manufactured by 0.35 pm 3P3M Flash process with 72 macro cells and 5 V voltage supply. The measurement results indicate that the devices are able to operate above the frequency of 66.7 MHz with the pin delay less than 10 ns. 展开更多
关键词 CPLD Flash process Macro cell system frequency.
下载PDF
Optimal Auxiliary Frequency Control of Wind Turbine Generators and Coordination with Synchronous Generators 被引量:22
5
作者 Ming Sun Yong Min +3 位作者 Lei Chen Kaiyuan Hou Deming Xia Hangyin Mao 《CSEE Journal of Power and Energy Systems》 SCIE CSCD 2021年第1期78-85,共8页
Auxiliary frequency control of a wind turbine generator(WTG) has been widely used to enhance the frequencysecurity of power systems with high penetration of renewableenergy. Previous studies recommend two types of con... Auxiliary frequency control of a wind turbine generator(WTG) has been widely used to enhance the frequencysecurity of power systems with high penetration of renewableenergy. Previous studies recommend two types of control schemes,including frequency droop control and emulated inertia control,which simulate the response characteristics of the synchronousgenerator (SG). This paper plans to further explore the optimalauxiliary frequency control of the wind turbine based on previousresearch. First, it is determined that the virtual inertia control haslittle effect on the maximum rate of change of frequency (MaxROCOF)if the time delay of the control link of WTG is taken intoconsideration. Secondly, if a WTG operates in maximum powerpoint tracking (MPPT) mode and uses the rotor deceleration forfrequency modulation, its optimal auxiliary frequency control willcontain only droop control. Furthermore, if the droop control isproperly delayed, better system frequency response (SFR) willbe obtained. The reason is that coordination between the WTGand SG is important for SFR when the frequency modulationcapability of the WTG is limited. The frequency modulationcapability of the WTG is required to be released more properly.Therefore, when designing optimal auxiliary frequency controlfor the WTG, a better control scheme is worth further study. 展开更多
关键词 frequency droop control power system frequency security rate of change of frequency(ROCOF) virtual inertia control wind turbine generator auxiliary frequency control
原文传递
Frequency-constrained Co-planning of Generation and Energy Storage with High-penetration Renewable Energy 被引量:11
6
作者 Chengming Zhang Lu Liu +3 位作者 Haozhong Cheng Dundun Liu Jianping Zhang Gang Li 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2021年第4期760-775,共16页
Large-scale renewable energy integration decreases the system inertia and restricts frequency regulation. To maintain the frequency stability, allocating adequate frequency-support sources poses a critical challenge t... Large-scale renewable energy integration decreases the system inertia and restricts frequency regulation. To maintain the frequency stability, allocating adequate frequency-support sources poses a critical challenge to planners. In this context, we propose a frequency-constrained coordination planning model of thermal units, wind farms, and battery energy storage systems (BESSs) to provide satisfactory frequency supports. Firstly, a modified multi-machine system frequency response (MSFR) model that accounts for the dynamic responses from both synchronous generators and grid-connected inverters is constructed with preset power-headroom. Secondly, the rate-of-change-of-frequency (ROCOF) and frequency response power are deduced to construct frequency constraints. A data-driven piecewise linearization (DDPWL) method based on hyperplane fitting and data classification is applied to linearize the highly nonlinear frequency response power. Thirdly, frequency constraints are inserted into our planning model, while the unit commitment based on the coordinated operation of the thermal-hydro-wind-BESS hybrid system is implemented. At last, the proposed model is applied to the IEEE RTS-79 test system. The results demonstrate the effectiveness of our co-planning model to keep the frequency stability. 展开更多
关键词 Battery energy storage system(BESS) data-driven piecewise linearization generation planning multi-machine system frequency response unit commitment wind farm
原文传递
Practical Realization of Optimal Auxiliary Frequency Control Strategy of Wind Turbine Generator 被引量:4
7
作者 Ming Sun Yong Min +4 位作者 Xuejun Xiong Lei Chen Le Zhao Yuyao Feng Bingran Wang 《Journal of Modern Power Systems and Clean Energy》 SCIE EI CSCD 2022年第3期617-626,共10页
Adding the auxiliary frequency control function to the wind turbine generator(WTG)is a solution to the frequency security problem of the power system caused by the replacement of the synchronous generator(SG)by the WT... Adding the auxiliary frequency control function to the wind turbine generator(WTG)is a solution to the frequency security problem of the power system caused by the replacement of the synchronous generator(SG)by the WTG.The auxiliary frequency control using rotor kinetic energy is an economical scheme because the WTG still runs at the maximum power point during normal operation.In this paper,the functional optimization model of the auxiliary frequency control strategy of WTG is established.The optimal auxiliary frequency control strategy is obtained by solving the model numerically.As for the practical realization of the control strategy,the coordination of the auxiliary frequency control with the maximum power point tracking(MPPT)control is studied.The practical auxiliary frequency control strategy is modified to adapt to different power disturbances in the system,and the parameter setting method is also proposed.The sensitivity of system frequency to control parameters is studied.Finally,the simulation results verify the effectiveness and practicability of the proposed control strategy. 展开更多
关键词 Power system frequency security wind turbine generator auxiliary frequency control rotor kinetic energy energy constraint
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部