In Saint-Louis, Senegal, a constructed wetland with horizontal flow reed beds (FHa and FHb) has demonstrated significant efficacy in treating municipal wastewater. Analyzing various treatment stages, the system showed...In Saint-Louis, Senegal, a constructed wetland with horizontal flow reed beds (FHa and FHb) has demonstrated significant efficacy in treating municipal wastewater. Analyzing various treatment stages, the system showed only a slight temperature variation, from an influent average of 26.3°C to an effluent of 24.7°C. Electrical conductivity decreased from 1331 mS/cm to 974.5 mS/cm post-primary treatment, with suspended solids (SS) dramatically reduced from 718.9 mg/L to 5.7 mg/L in the final effluent. Biochemical oxygen demand (BOD5) and chemical oxygen demand (COD) saw a notable decrease, from initial levels of 655.6 mg/L and 1240 mg/L to 2.3 mg/L and 71.3 mg/L, respectively. Nitrogenous compounds (N-TN) and phosphates () also decreased significantly, indicating the system’s nutrient removal capacity. Microbiological analysis revealed a reduction in fecal coliforms from 7.5 Ulog/100ml to 1.8 Ulog/100ml and a complete elimination of helminth eggs. The presence of Phragmites and Typha was instrumental in enhancing these reductions. The system’s compliance with the Senegalese standards for disposal into natural environments, WHO recommendations for unrestricted water reuse in irrigation, and the European legislation for water reuse was established. The effluent quality met the stringent criteria for various classes of agricultural reuse, illustrating the system’s potential for sustainable water management. This wetland model presents a robust solution for water-stressed regions, ensuring environmental protection while supporting agricultural needs. The study calls for ongoing research to further refine the system for optimal, reliable wastewater treatment and water resource sustainability.展开更多
Wastewaters from the chemical industry are usually of high-strength and may contain minor inhibitory and recalcitrant organics that are at times not readily identifiable. This paper describes the experience of a biolo...Wastewaters from the chemical industry are usually of high-strength and may contain minor inhibitory and recalcitrant organics that are at times not readily identifiable. This paper describes the experience of a biological waste water treatment plant (WWTP) processing a COD concentration of 43000 mg·L^-1 wastewater from an oxochemical manufacturing plant. Stage improvements of the plant process by dilution of the inhibitory influent using other chemical wastewater streams resulting in a synergistic process effect, and removal of inhibitory organics by phase separation via acidification, effectively achieved process optimization producing a high quality effluent. In particular, the COD removal efficiency of granular sludge based anaerobic reactors increased from 56% to 90%. The final effluent COD decreased from 250mg·L^-1 to 50mg·L^-1, consistently meeting the COD concentration of 100 mg·L^-1 regulatory discharge limit. The success of the process enhancements supports the hypothesis that long-chain quaternary carboxylic acids act as substrate inhibitors in the biological process.展开更多
This paper presents a comprehensive study of spatial and temporal patterns of water chemistry (1995-2008) in the Yesilirmak River catchment in Northern Turkey. Biological oxygen demand (BOD), dissolved oxygen (DO) and...This paper presents a comprehensive study of spatial and temporal patterns of water chemistry (1995-2008) in the Yesilirmak River catchment in Northern Turkey. Biological oxygen demand (BOD), dissolved oxygen (DO) and nutrient concentrations (nitrogen and phosphorus) are variable across the catchment because the upland areas are relatively undisturbed, and the lower catchment is dominated by urban, industrial and agricultural inputs. Seasonally, high nutrient concentrations occur in winter possibly due to flushing from the soil zone. Low summer flow and reduced dilution lead to high orthophosphate concentrations. However, denitrification seems to be more significant than dilution processes and this generates low nitrate concentrations in summer. Nutrient levels since 1995 do not show a significant upward trend. The current water quality status indicates that the river system is in poor condition. The majority of sites fall in the Turkish water classification class II-III and more than half fail the EU standards because of high nutrient concentrations. In order to improve the status of water quality to achieve good chemical and ecological status, there is clearly a need to improve pollution control within the river system by installing waste water treatment plants, while keeping the agricultural pollution to a minimum in the system.展开更多
文摘In Saint-Louis, Senegal, a constructed wetland with horizontal flow reed beds (FHa and FHb) has demonstrated significant efficacy in treating municipal wastewater. Analyzing various treatment stages, the system showed only a slight temperature variation, from an influent average of 26.3°C to an effluent of 24.7°C. Electrical conductivity decreased from 1331 mS/cm to 974.5 mS/cm post-primary treatment, with suspended solids (SS) dramatically reduced from 718.9 mg/L to 5.7 mg/L in the final effluent. Biochemical oxygen demand (BOD5) and chemical oxygen demand (COD) saw a notable decrease, from initial levels of 655.6 mg/L and 1240 mg/L to 2.3 mg/L and 71.3 mg/L, respectively. Nitrogenous compounds (N-TN) and phosphates () also decreased significantly, indicating the system’s nutrient removal capacity. Microbiological analysis revealed a reduction in fecal coliforms from 7.5 Ulog/100ml to 1.8 Ulog/100ml and a complete elimination of helminth eggs. The presence of Phragmites and Typha was instrumental in enhancing these reductions. The system’s compliance with the Senegalese standards for disposal into natural environments, WHO recommendations for unrestricted water reuse in irrigation, and the European legislation for water reuse was established. The effluent quality met the stringent criteria for various classes of agricultural reuse, illustrating the system’s potential for sustainable water management. This wetland model presents a robust solution for water-stressed regions, ensuring environmental protection while supporting agricultural needs. The study calls for ongoing research to further refine the system for optimal, reliable wastewater treatment and water resource sustainability.
文摘Wastewaters from the chemical industry are usually of high-strength and may contain minor inhibitory and recalcitrant organics that are at times not readily identifiable. This paper describes the experience of a biological waste water treatment plant (WWTP) processing a COD concentration of 43000 mg·L^-1 wastewater from an oxochemical manufacturing plant. Stage improvements of the plant process by dilution of the inhibitory influent using other chemical wastewater streams resulting in a synergistic process effect, and removal of inhibitory organics by phase separation via acidification, effectively achieved process optimization producing a high quality effluent. In particular, the COD removal efficiency of granular sludge based anaerobic reactors increased from 56% to 90%. The final effluent COD decreased from 250mg·L^-1 to 50mg·L^-1, consistently meeting the COD concentration of 100 mg·L^-1 regulatory discharge limit. The success of the process enhancements supports the hypothesis that long-chain quaternary carboxylic acids act as substrate inhibitors in the biological process.
文摘This paper presents a comprehensive study of spatial and temporal patterns of water chemistry (1995-2008) in the Yesilirmak River catchment in Northern Turkey. Biological oxygen demand (BOD), dissolved oxygen (DO) and nutrient concentrations (nitrogen and phosphorus) are variable across the catchment because the upland areas are relatively undisturbed, and the lower catchment is dominated by urban, industrial and agricultural inputs. Seasonally, high nutrient concentrations occur in winter possibly due to flushing from the soil zone. Low summer flow and reduced dilution lead to high orthophosphate concentrations. However, denitrification seems to be more significant than dilution processes and this generates low nitrate concentrations in summer. Nutrient levels since 1995 do not show a significant upward trend. The current water quality status indicates that the river system is in poor condition. The majority of sites fall in the Turkish water classification class II-III and more than half fail the EU standards because of high nutrient concentrations. In order to improve the status of water quality to achieve good chemical and ecological status, there is clearly a need to improve pollution control within the river system by installing waste water treatment plants, while keeping the agricultural pollution to a minimum in the system.