Although high resolution can be provided by electrical logging, the measured electrical log range is narrow and is limited to near the well. Borehole-surface electric potential measurements are able to detect a wide e...Although high resolution can be provided by electrical logging, the measured electrical log range is narrow and is limited to near the well. Borehole-surface electric potential measurements are able to detect a wide enough range but its resolution is limited, particularly for reservoirs with complex oil and water distribution or complicated structure. In this study, we attempt to accurately locate the 3-D reservoir water and oil distribution by combining borehole-surface and crosswell electric potentials. First, the distributions of oil and water in both vertical and horizontal directions are detected by the borehole-surface and erosswell electric potential methods, respectively, and then the measured crosswell potential result is used to calibrate the measured borehole-surface electric potential data to improve vertical resolution so that the residual oil distribution is determined in a lower half-space with three dimensions. The evaluation of residual oil distribution is obtained by investigation of differences between the simulation results of the reservoir with and without water flooding. The finite difference numerical simulation results prove that the spatial residual oil distribution can be effectively determined by combining the crosswell and borehole-surface electric potentials.展开更多
We performed corrosion case study and corrosion tests to assess the corrosion resistance of stainless steel type 304 pipes in tap water and hot water facilities. Circulating test equipment used for corrosion tests and...We performed corrosion case study and corrosion tests to assess the corrosion resistance of stainless steel type 304 pipes in tap water and hot water facilities. Circulating test equipment used for corrosion tests and two types of sample, plates and straight pipe specimens, were examined under different conditions of residual chlorine concentration in the test water. The results of case study analysis indicated that high degrees of pitting corrosion occurred on straight pipes with inner diameter < 50 mm. The results of corrosion tests showed that the residual chlorine concentration around the pitting corrosion of stainless steel type 304 was greater than 0.3 mg/L in the plate, regardless of the remaining chlorine concentration in the straight pipe specimens. These results suggest that straight pipes have higher corrosion susceptibility because of bending during production.展开更多
文摘Although high resolution can be provided by electrical logging, the measured electrical log range is narrow and is limited to near the well. Borehole-surface electric potential measurements are able to detect a wide enough range but its resolution is limited, particularly for reservoirs with complex oil and water distribution or complicated structure. In this study, we attempt to accurately locate the 3-D reservoir water and oil distribution by combining borehole-surface and crosswell electric potentials. First, the distributions of oil and water in both vertical and horizontal directions are detected by the borehole-surface and erosswell electric potential methods, respectively, and then the measured crosswell potential result is used to calibrate the measured borehole-surface electric potential data to improve vertical resolution so that the residual oil distribution is determined in a lower half-space with three dimensions. The evaluation of residual oil distribution is obtained by investigation of differences between the simulation results of the reservoir with and without water flooding. The finite difference numerical simulation results prove that the spatial residual oil distribution can be effectively determined by combining the crosswell and borehole-surface electric potentials.
文摘We performed corrosion case study and corrosion tests to assess the corrosion resistance of stainless steel type 304 pipes in tap water and hot water facilities. Circulating test equipment used for corrosion tests and two types of sample, plates and straight pipe specimens, were examined under different conditions of residual chlorine concentration in the test water. The results of case study analysis indicated that high degrees of pitting corrosion occurred on straight pipes with inner diameter < 50 mm. The results of corrosion tests showed that the residual chlorine concentration around the pitting corrosion of stainless steel type 304 was greater than 0.3 mg/L in the plate, regardless of the remaining chlorine concentration in the straight pipe specimens. These results suggest that straight pipes have higher corrosion susceptibility because of bending during production.