期刊文献+
共找到237,647篇文章
< 1 2 250 >
每页显示 20 50 100
Classification and technical target of water electrolysis for hydrogen production 被引量:1
1
作者 Kahyun Ham Sooan Bae Jaeyoung Lee 《Journal of Energy Chemistry》 SCIE EI CAS CSCD 2024年第8期554-576,I0012,共24页
Continuous efforts are underway to reduce carbon emissions worldwide in response to global climate change.Water electrolysis technology,in conjunction with renewable energy,is considered the most feasible hydrogen pro... Continuous efforts are underway to reduce carbon emissions worldwide in response to global climate change.Water electrolysis technology,in conjunction with renewable energy,is considered the most feasible hydrogen production technology based on the viable possibility of large-scale hydrogen production and the zero-carbon-emission nature of the process.However,for hydrogen produced via water electrolysis systems to be utilized in various fields in practice,the unit cost of hydrogen production must be reduced to$1/kg H_(2).To achieve this unit cost,technical targets for water electrolysis have been suggested regarding components in the system.In this paper,the types of water electrolysis systems and the limitations of water electrolysis system components are explained.We suggest guideline with recent trend for achieving this technical target and insights for the potential utilization of water electrolysis technology. 展开更多
关键词 Water electrolysis Hydrogen production technical target ELECTROCHEMISTRY
下载PDF
Interaction between systemic iron parameters and left ventricular structure and function in the preserved ejection fraction population:a two-sample bidirectional Mendelian randomization study 被引量:1
2
作者 Xiong-Bin MA Yong-Ming LIU +1 位作者 Yan-Lin LV Lin QIAN 《Journal of Geriatric Cardiology》 SCIE CAS CSCD 2024年第1期64-80,共17页
BACKGROUND Left ventricular(LV)remodeling and diastolic function in people with heart failure(HF)are correlated with iron status;however,the causality is uncertain.This Mendelian randomization(MR)study investigated th... BACKGROUND Left ventricular(LV)remodeling and diastolic function in people with heart failure(HF)are correlated with iron status;however,the causality is uncertain.This Mendelian randomization(MR)study investigated the bidirectional causal relationship between systemic iron parameters and LV structure and function in a preserved ejection fraction population.METHODS Transferrin saturation(TSAT),total iron binding capacity(TIBC),and serum iron and ferritin levels were extracted as instrumental variables for iron parameters from meta-analyses of public genome-wide association studies.Individuals without myocardial infarction history,HF,or LV ejection fraction(LVEF)<50%(n=16,923)in the UK Biobank Cardiovascular Magnetic Resonance Imaging Study constituted the outcome dataset.The dataset included LV end-diastolic volume,LV endsystolic volume,LV mass(LVM),and LVM-to-end-diastolic volume ratio(LVMVR).We used a two-sample bidirectional MR study with inverse variance weighting(IVW)as the primary analysis method and estimation methods using different algorithms to improve the robustness of the results.RESULTS In the IVW analysis,one standard deviation(SD)increased in TSAT significantly correlated with decreased LVMVR(β=-0.1365;95%confidence interval[CI]:-0.2092 to-0.0638;P=0.0002)after Bonferroni adjustment.Conversely,no significant relationships were observed between other iron and LV parameters.After Bonferroni correction,reverse MR analysis showed that one SD increase in LVEF significantly correlated with decreased TSAT(β=-0.0699;95%CI:-0.1087 to-0.0311;P=0.0004).No heterogeneity or pleiotropic effects evidence was observed in the analysis.CONCLUSIONS We demonstrated a causal relationship between TSAT and LV remodeling and function in a preserved ejection fraction population. 展开更多
关键词 FRACTION function parameters
下载PDF
Construction of a nomogram model to predict technical difficulty in performing laparoscopic sphincter-preserving radical resection for rectal cancer
3
作者 Xiao-Cong Zhou Shi-Wei Guan +3 位作者 Fei-Yue Ke Gaurav Dhamija Qiang Wang Bang-Fei Chen 《World Journal of Gastroenterology》 SCIE CAS 2024年第18期2418-2439,共22页
BACKGROUND Colorectal surgeons are well aware that performing surgery for rectal cancer becomes more challenging in obese patients with narrow and deep pelvic cavities.Therefore,it is essential for colorectal surgeons... BACKGROUND Colorectal surgeons are well aware that performing surgery for rectal cancer becomes more challenging in obese patients with narrow and deep pelvic cavities.Therefore,it is essential for colorectal surgeons to have a comprehensive understanding of pelvic structure prior to surgery and anticipate potential surgical difficulties.AIM To evaluate predictive parameters for technical challenges encountered during laparoscopic radical sphincter-preserving surgery for rectal cancer.METHODS We retrospectively gathered data from 162 consecutive patients who underwent laparoscopic radical sphincterpreserving surgery for rectal cancer.Three-dimensional reconstruction of pelvic bone and soft tissue parameters was conducted using computed tomography(CT)scans.Operative difficulty was categorized as either high or low,and multivariate logistic regression analysis was employed to identify predictors of operative difficulty,ultimately creating a nomogram.RESULTS Out of 162 patients,21(13.0%)were classified in the high surgical difficulty group,while 141(87.0%)were in the low surgical difficulty group.Multivariate logistic regression analysis showed that the surgical approach using laparoscopic intersphincteric dissection,intraoperative preventive ostomy,and the sacrococcygeal distance were independent risk factors for highly difficult laparoscopic radical sphincter-sparing surgery for rectal cancer(P<0.05).Conversely,the anterior-posterior diameter of pelvic inlet/sacrococcygeal distance was identified as a protective factor(P<0.05).A nomogram was subsequently constructed,demonstrating good predictive accuracy(C-index=0.834).CONCLUSION The surgical approach,intraoperative preventive ostomy,the sacrococcygeal distance,and the anterior-posterior diameter of pelvic inlet/sacrococcygeal distance could help to predict the difficulty of laparoscopic radical sphincter-preserving surgery. 展开更多
关键词 NOMOGRAM Rectal cancer Laparoscopic operation Sphincter-preserving surgery technical difficulty
下载PDF
Research on the origin and evolution of technical management regulations for railway
4
作者 Lei Tian Yuming Sun Yonggang Jia 《Railway Sciences》 2024年第6期779-787,共9页
Purpose–To facilitate technical managers and field workers to master and understand the provisions of Technical Management Regulations for Railway more accurately,so as to better serve the comprehensive revision of t... Purpose–To facilitate technical managers and field workers to master and understand the provisions of Technical Management Regulations for Railway more accurately,so as to better serve the comprehensive revision of the Regulations,this paper carries out the research on the traceability and evolution of the provisions of the Regulations.Design/methodology/approach–This paper studies and analyzes the evolution of the 11th edition of the Regulations by analyzing the relevance of clauses and summarizes the historical background of the development of calendar editions of the Regulations.The basic research on the traceability and evolution of the Regulations is carried out from four aspects:the continuity of the development of the Regulations,the authority of contents,the relevance of clauses and the richness of historical materials.Findings–From the first edition of the Regulations issued by the former Ministry of Railways in 1950 to the 11th edition,there have been ten comprehensive revisions.There is a strong correlation and continuity between the calendar editions of the Regulations in terms of chapter structure and clauses.Studying the context of the terms of the Regulations is an important way to understand and master the current clauses of the Regulations.Originality/value–Through the research on the traceability and evolution of the clauses of the Regulations,one is to explore the context of the development of railway technical equipment in China,the other is to clarify the historical background when the provisions were formulated and the third is to trace the development and evolution of the provisions.The revision of the Regulations is based on an accurate grasp of the context of the provisions,which can effectively judge the possible security risks caused by the revision of the provisions and avoid the possible risks in field implementation from the source. 展开更多
关键词 technical management regulations for railway Origin and evolution REVISION technical regulation Organization of train operation
下载PDF
Chronic Hepatitis B Virus Infection: Biological Parameters in Patients Treated with Tenofovir Disoproxil Fumarate
5
作者 Sanra Déborah Sanogo Moussa Y. Dicko +10 位作者 Lamine N’Diaye Ousmane Diarra Drissa Katilé Abdoulaye Maiga Ouatou Mallé Sabine Drabo Makan S. Tounkara Hourouma Sow Kadiatou Doumbia Anselme Konaté Moussa T. Diarra 《Open Journal of Gastroenterology》 CAS 2024年第4期145-151,共7页
Chronic hepatitis B causes a liver disease characterized by inflammation of the liver parenchyma. The aim of this study was to investigate the evolution of biological parameters in patients treated with Tenofovir for ... Chronic hepatitis B causes a liver disease characterized by inflammation of the liver parenchyma. The aim of this study was to investigate the evolution of biological parameters in patients treated with Tenofovir for chronic B infection at the Commune V referral health center in Bamako. We obtained a prevalence of 14.15%. The most represented age group was 31 - 40 years, with 36.8%. The sex ratio was 1.44 in favour of men. Viral load was undetectable after 18 months of treatment in 25 patients (42.37%). Tenofovir, the 1st-line drug in Mali, is effective on the biological parameters monitored in patients. 展开更多
关键词 Viral Hepatitis B TENOFOVIR Biological parameters
下载PDF
Adhesion of Technical Lignin-Based Non-Isocyanate Polyurethane Adhesives for Wood Bonding
6
作者 Jaewook Lee Byung-Dae Park Qinglin Wu 《Journal of Renewable Materials》 EI CAS 2024年第7期1187-1205,共19页
Lignin is the most abundant aromatic natural polymer,and receiving great attention in replacing various petro-leum-based polymers.The aim of this study is to investigate the feasibility of technical lignin as a polyol... Lignin is the most abundant aromatic natural polymer,and receiving great attention in replacing various petro-leum-based polymers.The aim of this study is to investigate the feasibility of technical lignin as a polyol for the synthesis of non-isocyanate polyurethane(NIPU)adhesives to substitute current polyurethane(PU)adhesives that have been synthesized with toxic isocyanate and polyols.Crude hardwood kraft lignin(C-HKL)was extracted from black liquor from a pulp mill followed by acetone fractionation to obtain acetone soluble-HKL(AS-HKL).Then,C-HKL,AS-HKL,and softwood sodium lignosulfonate(LS)were used for the synthesis of technical lignin-based NIPU adhesives through carbonation and polyamination and silane as a cross-linker.Their adhesion per-formance was determined for plywood.FTIR spectra showed the formation of urethane bonds and the reaction between lignin and silane.The NIPU adhesives prepared with C-HKL showed the highest adhesion strength among the three lignin-based NIPU adhesives.As the silane addition level increased,the adhesion strength of NIPU adhesives increased whereas formaldehyde emission decreased for all NIPU adhesives prepared.These results indicate that NIPU adhesives based on technical kraft lignin have a great potential as polyol for the synth-esis of bio-based NIPU adhesives for wood bonding. 展开更多
关键词 technical lignin non-isocyanate polyurethane wood adhesives adhesion strength formaldehyde emission
下载PDF
Technical efficiency of cocoa farms at varying elevation levels in Davao City, Philippines: implications to sustainable upland farming systems
7
作者 Francis Levi A.DURANO Jon Marx SARMIENTO +1 位作者 Larry N.DIGAL Pedro A.ALVIOLA IV 《Journal of Mountain Science》 SCIE CSCD 2024年第1期33-48,共16页
Elevation is one of many components that influence agriculture, and this in turn affects the level of both inputs and outputs of farmers. This article focuses on the productivity and technical efficiency of 100 cocoa ... Elevation is one of many components that influence agriculture, and this in turn affects the level of both inputs and outputs of farmers. This article focuses on the productivity and technical efficiency of 100 cocoa farms using cross-sectional data from areas ranging from 190 to 1021 m above sea level which were classified as low, medium, and high elevation in Davao City, considered as the chocolate capital of the Philippines. Using stochastic frontier analysis, the results showed that the cost of inputs per ha and the number of cocoa trees per ha significantly increase yield. Farms at high elevations were less technically efficient, as this entails lower temperatures and increased rainfall, and cocoa farming in those areas and conditions can be more challenging, especially with changes in farming practices, terrain, and distance to markets. Other significant variables were age of cocoa farms, married farmers, and age of the farmers. Older farms may be more developed, farmers who are married benefit from their spouses being able to readily contribute as farm labor, and lastly, older farmers' inefficiency may likely stem from nonadaptation of newer farming practices. With an average technical efficiency of 0.61, 0.63, and 0.26 in low, medium, and high elevation areas, respectively, farmers therefore have an incentive to improve farm practices and consider topographical variations found in high elevation areas. Recommendations for the improvement of technical efficiency of cocoa farms are better connectivity to markets, enhancing farm practices, and continuation and improvement of government programs on cocoa with an added emphasis on research. For farmers in high elevation areas, mitigating solutions such as sustainable agriculture practices and ecolabelling are key to improving efficiency and minimizing the potential negative impact on upland farming systems. Moreover, such adaptation measures may also contribute to sustainability of cocoa farming in high elevation areas. 展开更多
关键词 Cocoa farms Cobb-Douglas production function ELEVATION Philippines Stochastic frontier analysis technical efficiency
下载PDF
Study on the clogging mechanism of punching screen in sand control by the punching structure parameters
8
作者 Fu-Cheng Deng Fu-Lin Gui +5 位作者 Bai-Tao Fan Lei Wen Sheng-Hong Chen Ning Gong Yun-Chen Xiao Zhi-Hui Xu 《Petroleum Science》 SCIE EI CAS CSCD 2024年第1期609-620,共12页
As an independent sand control unit or a common protective shell of a high-quality screen,the punching screen is the outermost sand retaining unit of the sand control pipe which is used in geothermal well or oil and g... As an independent sand control unit or a common protective shell of a high-quality screen,the punching screen is the outermost sand retaining unit of the sand control pipe which is used in geothermal well or oil and gas well.However,most screens only consider the influence of the internal sand retaining medium parameters in the sand control performance design while ignoring the influence of the plugging of the punching screen on the overall sand retaining performance of the screen.To explore the clogging mechanism of the punching screen,this paper established the clogging mechanism calculation model of a single punching screen sand control unit by using the computational fluid mechanics-discrete element method(CFD-DEM)combined method.According to the combined motion of particles and fluids,the influence of the internal flow state on particle motion and accumulation was analyzed.The results showed that(1)the clogging process of the punching sand control unit is divided into three stages:initial clogging,aggravation of clogging and stability of clogging.In the initial stage of blockage,coarse particles form a loose bridge structure,and blockage often occurs preferentially at the streamline gathering place below chamfering inside the sand control unit.In the stage of blockage intensification,the particle mass develops into a relatively complete sand bridge,which develops from both ends of the opening to the center of the opening.In the stable plugging stage,the sand deposits show a“fan shape”and form a“V-shaped”gully inside the punching slot element.(2)Under a certain reservoir particle-size distribution,The slit length and opening height have a large influence on the permeability and blockage rate,while the slit width size has little influence on the permeability and blockage rate.The microscopic clogging mechanism and its law of the punching screen prevention unit are proposed in this study,which has some field guidance significance for the design of punching screen and sand prevention selection. 展开更多
关键词 Punching screen Plugging CFD-DEM Size parameter Sand control
下载PDF
A Physical Security Technology Based upon Doubly Multiple Parameters Weighted Fractional Fourier Transform
9
作者 Li Yong Sun Teng +2 位作者 Sha Xuejun Song Zhiqun Wang Bin 《China Communications》 SCIE CSCD 2024年第10期200-209,共10页
Enhancing the security of the wireless communication is necessary to guarantee the reliable of the data transmission, due to the broadcast nature of wireless channels. In this paper, we provide a novel technology refe... Enhancing the security of the wireless communication is necessary to guarantee the reliable of the data transmission, due to the broadcast nature of wireless channels. In this paper, we provide a novel technology referred to as doubly multiple parameters weighted fractional Fourier transform(DMWFRFT), which can strengthen the physical layer security of wireless communication. This paper introduces the concept of DM-WFRFT based on multiple parameters WFRFT(MP-WFRFT), and then presents its four properties. Based on these properties, the parameters decryption probability is analyzed in terms of the number of parameters. The number of parameters for DM-WFRFT is more than that of the MP-WFRFT,which indicates that the proposed scheme can further strengthen the the physical layer security. Lastly, some numerical simulations are carried out to illustrate that the efficiency of proposed DM-WFRFT is related to preventing eavesdropping, and the effect of parameters variety on the system performance is associated with the bit error ratio(BER). 展开更多
关键词 doubly multiple parameters weighted fractional Fourier transform(DM-WFRFT) physical layer security transform parameters variety
下载PDF
Quaternion-Based Adaptive Trajectory Tracking Control of a Rotor-Missile with Unknown Parameters Identification
10
作者 Jie Zhao Zhongjiao Shi +1 位作者 Yuchen Wang Wei Wang 《Defence Technology(防务技术)》 SCIE EI CAS CSCD 2024年第1期375-386,共12页
This paper investigates the adaptive trajectory tracking control problem and the unknown parameter identification problem of a class of rotor-missiles with parametric system uncertainties.First,considering the uncerta... This paper investigates the adaptive trajectory tracking control problem and the unknown parameter identification problem of a class of rotor-missiles with parametric system uncertainties.First,considering the uncertainty of structural and aerodynamic parameters,the six-degree-of-freedom(6Do F) nonlinear equations describing the position and attitude dynamics of the rotor-missile are established,respectively,in the inertial and body-fixed reference frames.Next,a hierarchical adaptive trajectory tracking controller that can guarantee closed-loop stability is proposed according to the cascade characteristics of the 6Do F dynamics.Then,a memory-augmented update rule of unknown parameters is proposed by integrating all historical data of the regression matrix.As long as the finitely excited condition is satisfied,the precise identification of unknown parameters can be achieved.Finally,the validity of the proposed trajectory tracking controller and the parameter identification method is proved through Lyapunov stability theory and numerical simulations. 展开更多
关键词 Rotor-missile Adaptive control Parameter identification Quaternion control
下载PDF
Comparison of ocular biometric parameters between two swept-source optical coherence tomography devices and Scheimpflug tomography in patients with cataract
11
作者 Shan Ma Cheng Li +6 位作者 Jing Sun Jun Yang Kai Wen Xi-Teng Chen Fang-Yu Zhao Rong-Yu Gao Fang Tian 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第8期1437-1446,共10页
AIM:To assess and compare the variations and agreements across different ocular biometric parameters using swept-source optical coherence tomography(SS-OCT)and Scheimpflug tomography in patients diagnosed with catarac... AIM:To assess and compare the variations and agreements across different ocular biometric parameters using swept-source optical coherence tomography(SS-OCT)and Scheimpflug tomography in patients diagnosed with cataract.METHODS:This prospective case series was conducted at Tianjin Medical University Eye Hospital.In total,212 eyes from 212 patients scheduled for phacoemulsification were included.Eyes were evaluated preoperatively using two SSOCT devices(IOLMaster700 and CASIA2)and Scheimpflug tomography(Pentacam).Central corneal thickness(CCT),anterior chamber depth(ACD),aqueous depth(AQD),white-to-white distance(WTW),flat simulated keratometry(Kf),steep simulated keratometry(Ks),mean keratometry(Km),and total corneal keratometry(TKm)were measured.Intraclass correlation coefficient(ICC),95%confidence intervals(CI)and limits of agreement(LoA)widths were conducted to assess differences and correlations between devices.RESULTS:All parameters,except for Ks,were significantly different.Pairwise comparison revealed no significant differences between keratometry obtained by IOLMaster 700 and Pentacam.LoA widths of all paired comparisons for Ks were>0.80 D.Except for WTW between IOLMaster 700 and CASIA2 and between CASIA2 and Pentacam,other Pearson’s coefficients between devices showed a strong correlation(all r>0.95).The ICC of WTW(ICC=0.438,95%CI 0.167-0.625)showed poor reliability.The reliability of CCT,ACD,and AQD was excellent(all ICC>0.95),whereas that of TKm was good(ICC=0.827,95%CI 0.221-0.939).A significant linear correlation was also observed among devices.CONCLUSION:The ocular parameters derived from the use of IOLMaster700,CASIA2,and Pentacam exhibit significant discrepancies;as such,measurements from these devices should not be deemed as interchangeable. 展开更多
关键词 ocular parameters swept-source optical coherence tomography CATARACT
下载PDF
Digital measuring the ocular morphological parameters of guinea pig eye in vivo with Python
12
作者 Yue Di Zhong-Bao Qiao +4 位作者 Hai-Yun Ye Xin-Yue Li Wen-Ting Luo Wang-Yi Fang Tong Qiao 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第2期239-246,共8页
AIM:To quantitatively measure ocular morphological parameters of guinea pig with Python technology.METHODS:Thirty-six eyeballs of eighteen 3-weekold guinea pigs were measured with keratometer and photographed to obtai... AIM:To quantitatively measure ocular morphological parameters of guinea pig with Python technology.METHODS:Thirty-six eyeballs of eighteen 3-weekold guinea pigs were measured with keratometer and photographed to obtain the horizontal,coronal,and sagittal planes respectively.The corresponding photo pixels-actual length ratio was acquired by a proportional scale.The edge coordinates were identified artificially by ginput function.Circle and conic curve fitting were applied to fit the contour of the eyeball in the sagittal,coronal and horizontal view.The curvature,curvature radius,eccentricity,tilt angle,corneal diameter,and binocular separation angle were calculated according to the geometric principles.Next,the eyeballs were removed,canny edge detection was applied to identify the contour of eyeball in vitro.The results were compared between in vivo and in vitro.RESULTS:Regarding the corneal curvature and curvature radius on the horizontal and sagittal planes,no significant differences were observed among results in vivo,in vitro,and the keratometer.The horizontal and vertical binocular separation angles were 130.6°±6.39°and 129.8°±9.58°respectively.For the corneal curvature radius and eccentricity in vivo,significant differences were observed between horizontal and vertical planes.CONCLUSION:The Graphical interface window of Python makes up the deficiency of edge detection,which requires too much definition in Matlab.There are significant differences between guinea pig and human beings,such as exotropic eye position,oblique oval eyeball,and obvious discrepancy of binoculus.This study helps evaluate objectively the ocular morphological parameters of small experimental animals in emmetropization research. 展开更多
关键词 ocular morphological parameters guinea pig digital measurement PYTHON
下载PDF
Correlation Study on Grain Size Characteristics and Geotechnical Properties of Surface Sediments in Qingdao Offshore Area
13
作者 LI Anlong WANG Panpan +5 位作者 GUO Xijun JI Xiangkun SHEN Kunming LIN Lin YAN Zhichao YUAN Lin 《Journal of Ocean University of China》 SCIE CAS CSCD 2024年第3期721-730,共10页
The comprehension of sediment grain size parameters and the corresponding sedimentary environment holds paramount importance in elucidating the engineering geological attributes of the subaqueous seabed.This study del... The comprehension of sediment grain size parameters and the corresponding sedimentary environment holds paramount importance in elucidating the engineering geological attributes of the subaqueous seabed.This study delineated the sedimentary environment zoning in the northern sea area of Qingdao through cluster analysis of grain size parameters derived from 123 surface sediment samples.The study analyzed the correlation between sediment geotechnical indices and grain size parameters across diverse sedimentary environments.A correlation equation was established for samples exhibiting a strong correlation.The study found four distinct sedimentary environments in the study area:coastal,transitional,shallow sea,and residual.Within the same sedimentary environment,the average grain size and sorting coefficient exhibit significant correlations with geotechnical indices such as water content,density,shear strength,plastic limit,liquid limit,and plastic index.However,notable disparities in the correlation between grain size parameters and geotechnical indices emerge across different sedimentary environments. 展开更多
关键词 grain size parameters cluster analysis sedimentary environment CORRELATIONS geotechnical indexes
下载PDF
Analysis and comparison of retinal vascular parameters under different glucose metabolic status based on deep learning
14
作者 Yan Jiang Di Gong +7 位作者 Xiao-Hong Chen Lin Yang Jing-Jing Xu Qi-Jie Wei Bin-Bin Chen Yong-Jiang Cai Wen-Qun Xi Zhe Zhang 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第9期1581-1591,共11页
AIM:To develop a deep learning-based model for automatic retinal vascular segmentation,analyzing and comparing parameters under diverse glucose metabolic status(normal,prediabetes,diabetes)and to assess the potential ... AIM:To develop a deep learning-based model for automatic retinal vascular segmentation,analyzing and comparing parameters under diverse glucose metabolic status(normal,prediabetes,diabetes)and to assess the potential of artificial intelligence(AI)in image segmentation and retinal vascular parameters for predicting prediabetes and diabetes.METHODS:Retinal fundus photos from 200 normal individuals,200 prediabetic patients,and 200 diabetic patients(600 eyes in total)were used.The U-Net network served as the foundational architecture for retinal arteryvein segmentation.An automatic segmentation and evaluation system for retinal vascular parameters was trained,encompassing 26 parameters.RESULTS:Significant differences were found in retinal vascular parameters across normal,prediabetes,and diabetes groups,including artery diameter(P=0.008),fractal dimension(P=0.000),vein curvature(P=0.003),C-zone artery branching vessel count(P=0.049),C-zone vein branching vessel count(P=0.041),artery branching angle(P=0.005),vein branching angle(P=0.001),artery angle asymmetry degree(P=0.003),vessel length density(P=0.000),and vessel area density(P=0.000),totaling 10 parameters.CONCLUSION:The deep learning-based model facilitates retinal vascular parameter identification and quantification,revealing significant differences.These parameters exhibit potential as biomarkers for prediabetes and diabetes. 展开更多
关键词 deep learning retinal vascular parameters segmentation model DIABETES PREDIABETES
下载PDF
Effects of Fresh Cupressus sempervirens Leaves Infusion on Growth Performance, Intestinal Microbiota and Haemato-Biochemical Parameters in Broilers
15
作者 Donfack Mikael Noumbissi Marie Noël Bertine +7 位作者 Ciemeni Michelle Aimee Tindo Tsamene Romario Evelyn Ngwa Bih Djamen Tchantchou Chamberlin Nyembo Kondo Camile Tsafong Jeatsa Franklain Necdem Tsafack Boris Kana Jean Raphaël 《Open Journal of Animal Sciences》 2024年第2期70-87,共18页
The accumulation of growth-promoting antibiotic residues in animal products and the resistance developed by bacteria in poultry farms has led to a search for natural compounds derived from plants. This study was desig... The accumulation of growth-promoting antibiotic residues in animal products and the resistance developed by bacteria in poultry farms has led to a search for natural compounds derived from plants. This study was designed to promote the production performance of broiler chickens using fresh Cupressus sempervirens leaves infusion. Fresh Cupressus sempervirens leaves were harvested, washed, chopped and ground to a paste using a blender and fermented for three days in a closed container at a rate of 500 g/L of water. The solution obtained was filtered and added at the rate of 2, 4, 6, 8 and 10 ml/L of drinking water. The chickens fed on the graded level of the solution were compared to a control ration without an additive and positive control group supplemented with 1 g antibiotic/kg feed. At the finisher phase and throughout the study period, water intake increased significantly (P < 0.05) with increasing levels of infusion. Feed intake decreased significantly (P < 0.05) with 2 and 4 ml of infusion/L drinking water. Live weight and weight gain were significantly (P < 0.05) higher with 6 ml/L, while feed conversion significantly (P < 0.05) decreased with the same treatment compared with the control treatment without additives (T0). Carcass characteristics were not significantly (P > 0.05) affected by the inclusion of Cupressus sempervirens infusion. Haematological parameters significantly (P < 0.05) increase independently of the rate of incorporation of the infusion into the drinking water, with the exception of RBCs, MCHT and PCT. Serum content in total protein, globulins, LDL cholesterol and triglycerides were significantly (P < 0.05) high with 8 and 10 ml Cupressus sempervirens infusion/litre drinking water as compared to all other treatments. AST, ALT, urea, creatine, albumin, total cholesterol and HDL-cholesterol were not significantly affected. The lactic acid bacteria load increased significantly (P E. coli and salmonella counts decreased significantly (P < 0.05) with infusion compared to the control without additive. In conclusion, 6 ml of Cupressus sempervirens infusion can be used as an alternative to antibiotic feed additives to promote growth performance in broilers. 展开更多
关键词 BROILERS Cupressus sempervirens Growth Performance Haemato-Biochemical parameters Intestinal Microbiota
下载PDF
Determination of uncertainties of geomechanical parameters of metamorphic rocks using petrographic analyses
16
作者 Behzad Dastjerdy Ali Saeidi Shahriyar Heidarzadeh 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2024年第2期345-364,共20页
Geomechanical parameters of intact metamorphic rocks determined from laboratory testing remain highly uncertain because of the great intrinsic variability associated with the degrees of metamorphism.The aim of this pa... Geomechanical parameters of intact metamorphic rocks determined from laboratory testing remain highly uncertain because of the great intrinsic variability associated with the degrees of metamorphism.The aim of this paper is to develop a proper methodology to analyze the uncertainties of geomechanical characteristics by focusing on three domains,i.e.data treatment process,schistosity angle,and mineralogy.First,the variabilities of the geomechanical laboratory data of Westwood Mine(Quebec,Canada)were examined statistically by applying different data treatment techniques,through which the most suitable outlier methods were selected for each parameter using multiple decision-making criteria and engineering judgment.Results indicated that some methods exhibited better performance in identifying the possible outliers,although several others were unsuccessful because of their limitation in large sample size.The well-known boxplot method might not be the best outlier method for most geomechanical parameters because its calculated confidence range was not acceptable according to engineering judgment.However,several approaches,including adjusted boxplot,2MADe,and 2SD,worked very well in the detection of true outliers.Also,the statistical tests indicate that the best-fitting probability distribution function for geomechanical intact parameters might not be the normal distribution,unlike what is assumed in most geomechanical studies.Moreover,the negative effects of schistosity angle on the uniaxial compressive strength(UCS)variabilities were reduced by excluding the samples within a specific angle range where the UCS data present the highest variation.Finally,a petrographic analysis was conducted to assess the associated uncertainties such that a logical link was found between the dispersion and the variabilities of hard and soft minerals. 展开更多
关键词 Intact rock parameters Natural variabilities Outlier detection methods UNCERTAINTIES Westwood mine MINERALOGY
下载PDF
A Novel On-Site-Real-Time Method for Identifying Characteristic Parameters Using Ultrasonic Echo Groups and Neural Network
17
作者 Shuyong Duan Jialin Zhang +2 位作者 Heng Ouyang Xu Han Guirong Liu 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2024年第1期215-228,共14页
On-site and real-time non-destructive measurement of elastic constants for materials of a component in a in-service structure is a challenge due to structural complexities,such as ambiguous boundary,variable thickness... On-site and real-time non-destructive measurement of elastic constants for materials of a component in a in-service structure is a challenge due to structural complexities,such as ambiguous boundary,variable thickness,nonuniform material properties.This work develops for the first time a method that uses ultrasound echo groups and artificial neural network(ANN)for reliable on-site real-time identification of material parameters.The use of echo groups allows the use of lower frequencies,and hence more accommodative to structural complexity.To train the ANNs,a numerical model is established that is capable of computing the waveform of ultrasonic echo groups for any given set of material properties of a given structure.The waveform of an ultrasonic echo groups at an interest location on the surface the structure with material parameters varying in a predefined range are then computed using the numerical model.This results in a set of dataset for training the ANN model.Once the ANN is trained,the material parameters can be identified simultaneously using the actual measured echo waveform as input to the ANN.Intensive tests have been conducted both numerically and experimentally to evaluate the effectiveness and accuracy of the currently proposed method.The results show that the maximum identification error of numerical example is less than 2%,and the maximum identification error of experimental test is less than 7%.Compared with currently prevailing methods and equipment,the proposefy the density and thickness,in addition to the elastic constants.Moreover,the reliability and accuracy of inverse prediction is significantly improved.Thus,it has broad applications and enables real-time field measurements,which has not been fulfilled by any other available methods or equipment. 展开更多
关键词 Parameter identification Ultrasonic echo group High-precision modeling Artificial neural network NDT
下载PDF
Surface Water Quality Profiling Using Physicochemical Parameters in Open Defecation Free and Non-Open Defecation Free Local Government Areas in Benue State, Nigeria
18
作者 Moses T. Asoo Celestine U. Aguoru +1 位作者 Innocent O. Ogbonna Hyacinth O.A. Oluma 《Open Journal of Modern Hydrology》 CAS 2024年第3期174-191,共18页
Physicochemical parameters of surface water sources in the study of local government areas (LGAs) were assessed using standard procedures. The mean physicochemical parameters for pH (5.49), NO2 (0.23 mg/L), SO4 (0.77 ... Physicochemical parameters of surface water sources in the study of local government areas (LGAs) were assessed using standard procedures. The mean physicochemical parameters for pH (5.49), NO2 (0.23 mg/L), SO4 (0.77 mg/L), Na (28.72 mg/L), Ca (28.94 mg/L), Mg (17.50 mg/L), Cl (11.65 mg/L), TSS (6.27 mg/L), TDS (104.23 mg/L), BOD (2.83 mg/L) and F (0.87 mg/L) were below WHO standards irrespective of their defecation status. The values for electrical conductivity (EC) (2770.50 µs/cm, turbidity (481.24 NTU), dissolved oxygen (DO) (5.32 mg/L), chemical oxygen demand (COD) (445.50 mg/L), K (125.06 mg/L), PO4 (0.78 mg/L) and Fe (0.57 mg/L) were above the WHO limits for safe water. Higher EC and COD values obtained in the study is evidence of pollution of the water sources by organic matter. 展开更多
关键词 Open Defecation Surface Water Water Quality Standard Physicochemical parameters
下载PDF
Effects of processing parameters on fabrication defects,microstructure and mechanical properties of additive manufactured Mg–Nd–Zn–Zr alloy by selective laser melting process
19
作者 Wenyu Xu Penghuai Fu +4 位作者 Nanqing Wang Lei Yang Liming Peng Juan Chen Wenjiang Ding 《Journal of Magnesium and Alloys》 SCIE EI CAS CSCD 2024年第6期2249-2266,共18页
Mg–3Nd–0.2Zn–0.4Zr(NZ30K,wt.%)alloy is a new kind of high-performance metallic biomaterial.The combination of the NZ30K Magnesium(Mg)alloy and selective laser melting(SLM)process seems to be an ideal solution to pr... Mg–3Nd–0.2Zn–0.4Zr(NZ30K,wt.%)alloy is a new kind of high-performance metallic biomaterial.The combination of the NZ30K Magnesium(Mg)alloy and selective laser melting(SLM)process seems to be an ideal solution to produce porous Mg degradable implants.However,the microstructure evolution and mechanical properties of the SLMed NZ30K Mg alloy were not yet studied systematically.Therefore,the fabrication defects,microstructure,and mechanical properties of the SLMed NZ30K alloy under different processing parameters were investigated.The results show that there are two types of fabrication defects in the SLMed NZ30K alloy,gas pores and unfused defects.With the increase of the laser energy density,the porosity sharply decreases to the minimum first and then slightly increases.The minimum porosity is 0.49±0.18%.While the microstructure varies from the large grains with lamellar structure inside under low laser energy density,to the large grains with lamellar structure inside&the equiaxed grains&the columnar grains under middle laser energy density,and further to the fine equiaxed grains&the columnar grains under high laser energy density.The lamellar structure in the large grain is a newly observed microstructure for the NZ30K Mg alloy.Higher laser energy density leads to finer grains,which enhance all the yield strength(YS),ultimate tensile strength(UTS)and elongation,and the best comprehensive mechanical properties obtained are YS of 266±2.1 MPa,UTS of 296±5.2 MPa,with an elongation of 4.9±0.68%.The SLMed NZ30K Mg alloy with a bimodal-grained structure consisting of fine equiaxed grains and coarser columnar grains has better elongation and a yield drop phenomenon. 展开更多
关键词 Selective laser melting Mg alloy Processing parameter Lamellar structure Bimodal-grained structure
下载PDF
Performance in the Fundamentals of Laparoscopic Surgery: Does it reflect global rating scales in the Objective Structured Assessment of Technical Skills in porcine laparoscopic surgery?
20
作者 Ho Yee Tiong Wei Zheng So +10 位作者 Jeremy Yuen-Chun Teoh Shuji Isotani Gang Zhu Teng Aik Ong Eddie Shu-Yin Chan Peggy Sau-Kwan Chu Kittinut Kijvikai Ming Liu Bannakji Lojanapiwat Michael Wong Anthony Chi-Fai Ng 《Asian Journal of Urology》 CSCD 2024年第3期443-449,共7页
Objective:To correlate the utility of the Fundamentals of Laparoscopic Surgery(FLS)manual skills program with the Objective Structured Assessment of Technical Skills(OSATS)global rating scale in evaluating operative p... Objective:To correlate the utility of the Fundamentals of Laparoscopic Surgery(FLS)manual skills program with the Objective Structured Assessment of Technical Skills(OSATS)global rating scale in evaluating operative performance.Methods:The Asian Urological Surgery Training and Educational Group(AUSTEG)Laparoscopic Upper Tract Surgery Course implemented and validated the FLS program for its usage in laparoscopic surgical training.Delegates’basic laparoscopic skills were assessed using three different training models(peg transfer,precision cutting,and intra-corporeal suturing).They also performed live porcine laparoscopic surgery at the same workshop.Live surgery skills were assessed by blinded faculty using the OSATS rating scale.Results:From March 2016 to March 2019,a total of 81 certified urologists participated in the course,with a median of 5 years of post-residency experience.Although differences in task time did not reach statistical significance,those with more surgical experience were visibly faster at completing the peg transfer and intra-corporeal suturing FLS tasks.However,they took longer to complete the precision cutting task than participants with less experience.Overall OSATS scores correlated weakly with all three FLS tasks(peg transfer time:r=0.331,r^(2)=0.110;precision cutting time:r=0.240,r^(2)=0.058;suturing with intracorporeal knot time:r=0.451,r^(2)=0.203).Conclusion:FLS task parameters did not correlate strongly with OSATS globing rating scale performance.Although FLS task models demonstrated strong validity,it is important to assimilate the inconsistencies when benchmarking technical proficiency against real-life operative competence,as evaluated by FLS and OSATS,respectively. 展开更多
关键词 The Fundamentals of Laparoscopic Surgery Assessment of technical Skills Laparoscopic training Surgical education Surgical training Urological laparoscopic surgery
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部