期刊文献+
共找到17篇文章
< 1 >
每页显示 20 50 100
Transient Temperature Analysis for Industrial AC Arc Furnace Bottom 被引量:3
1
作者 Murat Tun 《Journal of Iron and Steel Research(International)》 SCIE CAS CSCD 2004年第6期1-4,共4页
Heat losses from the furnaces depend on the design and size. The surface heat loss from the bottom of an industrial AC electric arc furnace (EAF) possesses an important fraction of overall losses. So in this study the... Heat losses from the furnaces depend on the design and size. The surface heat loss from the bottom of an industrial AC electric arc furnace (EAF) possesses an important fraction of overall losses. So in this study the transient temperature variation at the bottom of the EAF was investigated. The transient temperature analysis was carried out using MATLAB computer program. T=T(r, t) for different bottom lining layers was depicted. 展开更多
关键词 electric arc furnace steel production industrial system transient temperature analysis
下载PDF
Transient Temperature Analysis of Slab in Erdemir
2
作者 nal amdali Murat Tun Sedat Sisbot 《Journal of Iron and Steel Research(International)》 SCIE EI CAS CSCD 2008年第2期43-45,共3页
A transient thermal model was developed for slab furnaces in Eregli Iron and Steel Works (Erdemir) in Turkey and the model was solved using the FlexPDE computer program. This program uses the finite element method. ... A transient thermal model was developed for slab furnaces in Eregli Iron and Steel Works (Erdemir) in Turkey and the model was solved using the FlexPDE computer program. This program uses the finite element method. Program codes were written to solve the temperature distribution of slabs that are put into furnace at 25 ℃ and removed at about 1 250℃. To obtain the optimum slab exit temperature variation, the necessary air temperature inside the furnace was calculated to be 1 390℃. The slab temperature versus time and the temperature variation inside the slab were depicted. 展开更多
关键词 Erdemir finite element method industrial system slab slab furnace temperature analysis
原文传递
Impact Analysis of MPL on a PEFC Cell’s Temperature Distribution with Thin PEM and GDL for Operating at Higher Temperature than Usual 被引量:1
3
作者 Akira Nishimura Nozomu Kono +2 位作者 Kyohei Toyoda Yuya Kojima Mohan Lal Kolhe 《Journal of Energy and Power Engineering》 2021年第2期39-51,共13页
According to the New Energy and Industry Technology Development Organization(NEDO)road map 2017 of Japan,polymer electrolyte fuel cell(PEFC)system is required to be operated at 90°C and 100°C for stationary ... According to the New Energy and Industry Technology Development Organization(NEDO)road map 2017 of Japan,polymer electrolyte fuel cell(PEFC)system is required to be operated at 90°C and 100°C for stationary and mobility applications,respectively.However,the general PEFC,which has Nafion membrane is operated within the temperature range between 60°C and 80°C.It is important to understand the temperature distribution in a PEFC cell for analyzing performance on working life span of PEFC.This study focuses on the combination of thin polymer electrolyte membrane(PEM)and thin gas diffusion layer(GDL)to improve power generation performance under relatively higher temperature operation conditions.In addition,this study also focuses on effect of micro porous layer(MPL),which can promote the mass transfer,over temperature distribution.The key aim of this study is to analyze impact of MPL of temperature distribution on the reaction surface(Treact)of a cell of PEFC using thin PEM and GDL with variations of H2 and O2 supply flow rates and their relative humidity(RH)with changing the initial operating temperature(Tini)from 80°C to 100°C.As a result,the distribution of Treact without MPL,for anode and cathode at 80%RH and Tini at 80°C and 90°C,is higher than normal conditions.There is a small difference in temperature distribution among different RH conditions with MPL.The distributions of Treact are relatively flat and almost the same among different RH conditions without MPL at Tini=100°C,while the distributions of Treact with MPL are almost the same among different RH conditions.This study is revealed that more even temperature distribution and higher power generation performance can be obtained in the case without MPL compared to the case with MPL. 展开更多
关键词 PEFC temperature distribution analysis MPL thin PEM and thin GDL higher temperature operation
下载PDF
The Fuzzy Cluster Analysis in Identification of Key Temperatures in Machine Tool
4
作者 ZHAO Da-quan 1, ZHENG Li 1, XIANG Wei-hong 1, LI Kang 1, LIU Da-cheng 1, ZHANG Bo-peng 2 (1. Department of Industrial Engineering, Tsinghua University, 2. Department of Precision Instruments and Mechanology, Tsinghua University, B eijing 100084, China) 《厦门大学学报(自然科学版)》 CAS CSCD 北大核心 2002年第S1期88-89,共2页
The thermal-induced error is a very important sour ce of machining errors of machine tools. To compensate the thermal-induced machin ing errors, a relationship model between the thermal field and deformations was need... The thermal-induced error is a very important sour ce of machining errors of machine tools. To compensate the thermal-induced machin ing errors, a relationship model between the thermal field and deformations was needed. The relationship can be deduced by virtual of FEM (Finite Element Method ), ANN (Artificial Neural Network) or MRA (Multiple Regression Analysis). MR A is on the basis of a total understanding of the temperature distribution of th e machine tool. Although the more the temperatures measured are, the more accura te the MRA is, too more temperatures will hinder the analysis calculation. So it is necessary to identify the key temperatures of the machine tool. The selectio n of key temperatures decides the efficiency and precision of MRA. Because of th e complexities and multi-input and multi-output structure of the relationships , the exact quantitative portions as well as the unclear portions must be taken into consideration together to improve the identification of key temperatures. I n this paper, a fuzzy cluster analysis was used to select the key temperatures. The substance of identifying the key temperatures is to group all temperatures b y their relativity, and then to select a temperature from each group as the repr esentation. A fuzzy cluster analysis can uncover the relationships between t he thermal field and deformations more truly and thoroughly. A fuzzy cluster ana lysis is the cluster analysis based on fuzzy sets. Given U={u i|i=0,...,N}, in which u i is the temperature measured, a fuzzy matrix R can be obta ined. The transfer close package t(R) can be deduced from R. A fuzzy clu ster of U then conducts on the basis of t(R). Based on the fuzzy cluster analysis discussed above, this paper identified the k ey temperatures of a horizontal machining center. The number of the temperatures measured was reduced to 4 from 32, and then the multiple regression relationshi p models between the 4 temperatures and the thermal deformations of the spindle were drawn. The remnant errors between the regression models and measured deform ations reached a satisfying low level. At the same time, the decreasing of tempe rature variable number improved the efficiency of measure and analysis greatly. 展开更多
关键词 The Fuzzy Cluster analysis in Identification of Key temperatures in Machine Tool
下载PDF
Design and analysis of a high loss density motor cooling system with water cold plates
5
作者 Xin Zhao Haojie Cui +2 位作者 Yun Teng Zhe Chen Guangwei Liu 《Global Energy Interconnection》 EI CSCD 2023年第3期343-354,共12页
Aiming at reducing the difficulty of cooling the interior of high-density motors,this study proposed the placement of a water cold plate cooling structure between the axial laminations of the motor stator.The effect o... Aiming at reducing the difficulty of cooling the interior of high-density motors,this study proposed the placement of a water cold plate cooling structure between the axial laminations of the motor stator.The effect of the cooling water flow,thickness of the plate,and motor loss density on the cooling effect of the water cold plate were studied.To compare the cooling performance of water cold plate and outer spiral water jacket cooling structures,a high-speed permanent magnet motor with a high loss density was used to establish two motor models with the two cooling structures.Consequently,the cooling effects of the two models were analyzed using the finite element method under the same loss density,coolant flow,and main dimensions.The results were as follows.(1)The maximum and average temperatures of the water cold plate structure were reduced by 25.5%and 30.5%,respectively,compared to that of the outer spiral water jacket motor;(2)Compared with the outer spiral water jacket structure,the water cold plate structure can reduce the overall mass and volume of the motor.Considering a 100 kW high-speed permanent magnet motor as an example,a water cold plate cooling system was designed,and the temperature distribution is analyzed,with the result indicating that the cooling structure satisfied the cooling requirements of the high loss density motor. 展开更多
关键词 Cooling system design High loss density motor Water cold plate temperature field analysis
下载PDF
Characteristics Analysis of the Temperature inside and outside the Themometer Shelter in Changsha during Summer
6
作者 Chen Zhaohui Fan Yu 《Meteorological and Environmental Research》 CAS 2014年第11期13-18,共6页
A statistical analysis on the simultaneous observation data of the temperature inside and outside the themometer shelter in Changsha during summer of 2011 and 2012 was carried out. The results show that the temperatur... A statistical analysis on the simultaneous observation data of the temperature inside and outside the themometer shelter in Changsha during summer of 2011 and 2012 was carried out. The results show that the temperature outside the themometer shelter is higher( lower) than that inside the themometer shelter in the daytime( nighttime). However,there exists a similar variation trend for the average temperature and the extremely maximum temperature inside and outside the themometer shelter in summer. The average temperature and the extremely maximum temperature outside the themometer shelter are higher than that inside the themometer shelter. Furthermore,there exists a difference between the temperatures inside and outside the themometer shelter during different weather conditions. The difference of average temperature reaches 1. 2 ℃ in rainy day,2. 8 ℃ in cloudy day and 3. 1 ℃ in sunny day,and the extremely maximum temperature difference reaches 6. 4 ℃. Especially for the days of high temperature ≥35 ℃,there is 61 high temperature days inside the themometer shelter,while there is 125 high temperature days inside the themometer shelter during 2011- 2012. Furthermore,the extremely maximum temperatures inside and outside the themometer shelter are 38. 9 and42. 0 ℃ respectively. Rainfall and showery rain are the most effective ways to relieve the high temperature in summer. Therefore,the difference between the temperatures inside and outside the themometer shelter should be taken into account in the high temperature forecast and public meteorological service. 展开更多
关键词 temperature inside and outside the themometer shelter Summer Characteristics analysis China
下载PDF
Mechanism of unsteady aerodynamic heating with sudden change in surface temperature 被引量:2
7
作者 陈皓 鲍麟 《Applied Mathematics and Mechanics(English Edition)》 SCIE EI 2009年第2期163-174,共12页
The characteristics and mechanism of unsteady aerodynamic heating of a transient hypersonic boundary layer caused by a sudden change in surface temperature are studied. The complete time history of wall heat flux is p... The characteristics and mechanism of unsteady aerodynamic heating of a transient hypersonic boundary layer caused by a sudden change in surface temperature are studied. The complete time history of wall heat flux is presented with both analytical and numerical approaches. With the analytical method, the unsteady compressible boundary layer equation is solved. In the neighborhood of the initial and final steady states, the transient responses can be expressed with a steady-state solution plus a perturbation series. By combining these two solutions, a complete solution in the entire time domain is achieved. In the region in which the analytical approach is applicable, numerical results are in good agreement with the analytical results, showing reliability of the methods. The result shows two distinct features of the unsteady response. In a short period just after a sudden increase in the wall temperature, the direction of the wall heat flux is reverted, and a new inflexion near the wall occurs in the profile of the thermal boundary layer. This is a typical unsteady characteristic. However, these unsteady responses only exist in a very short period in hypersonic flows, meaning that, in a long-term aerodynamic heating process considering only unsteady surface temperature, the unsteady characteristics of the flow can be ignored, and the traditional quasi-steady aerodynamic heating prediction methods are still valid. 展开更多
关键词 unsteady aerodynamic heating HYPERSONIC unsteady surface temperature approximate analysis numerical simulation
下载PDF
Research on the principle of space high-precision temperature control system of liquid crystals based Stokes polarimeter 被引量:1
8
作者 Xin-Wei Zhang Yang Zhang +2 位作者 Jia-Ben Lin Jun-Feng Hou Yuan-Yong Deng 《Research in Astronomy and Astrophysics》 SCIE CAS CSCD 2021年第1期97-104,共8页
The magnetic field is one of the most important parameters in solar physics,and a polarimeter is the key device to measure the solar magnetic field.Liquid crystals based Stokes polarimeter is a novel technology,and wi... The magnetic field is one of the most important parameters in solar physics,and a polarimeter is the key device to measure the solar magnetic field.Liquid crystals based Stokes polarimeter is a novel technology,and will be applied for magnetic field measurement in the first space-based solar observatory satellite developed by China,Advanced Space-based Solar Observatory.However,the liquid crystals based Stokes polarimeter in space is not a mature technology.Therefore,it is of great scientific significance to study the control method and characteristics of the device.The retardation produced by a liquid crystal variable retarder is sensitive to the temperature,and the retardation changes 0.09°per 0.10℃.The error in polarization measurement caused by this change is 0.016,which affects the accuracy of magnetic field measurement.In order to ensure the stability of its performance,this paper proposes a high-precision temperature control system for liquid crystals based Stokes polarimeter in space.In order to optimize the structure design and temperature control system,the temperature field of liquid crystals based Stokes polarimeter is analyzed by the finite element method,and the influence of light on the temperature field of the liquid crystal variable retarder is analyzed theoretically.By analyzing the principle of highprecision temperature measurement in space,a high-precision temperature measurement circuit based on integrated operational amplifier,programmable amplifier and 12 bit A/D is designed,and a high-precision space temperature control system is developed by applying the integral separation PI temperature control algorithm and PWM driving heating films.The experimental results show that the effect of temperature control is accurate and stable,whenever the liquid crystals based Stokes polarimeter is either in the air or vacuum.The temperature stability is within±0.0150℃,which demonstrates greatly improved stability for the liquid crystals based Stokes polarimeter. 展开更多
关键词 liquid crystals based Stokes polarimeter high-precision temperature measurement space high-precision temperature control temperature field analysis PID control
下载PDF
Characterization of T-complex polypeptide 1 (TCP-1) from the Chilo suppressalis HSP60 family and its expression in response to temperature stress 被引量:3
9
作者 YU Tong-ying LU Ming-xing CUI Ya-dong 《Journal of Integrative Agriculture》 SCIE CAS CSCD 2018年第5期1032-1039,共8页
Many proteins require assistance from molecular chaperones at various stages to attain correctly folded states and functional conformations during protein synthesis. In this study, the gene encoding T-complex polypept... Many proteins require assistance from molecular chaperones at various stages to attain correctly folded states and functional conformations during protein synthesis. In this study, the gene encoding T-complex polypeptide 1(TCP-1), which belongs to the heat shock protein 60(HSP60) family, was isolated and characterized from the rice stem borer, Chilo suppressalis, by RACE and q PCR, respectively. The full-length c DNA of Tcp-1 was 2 144 bp and encoded a 1 635-bp ORF; the deduced translational product contained 545 amino acids with 5′-and 3′-UTRs and an isoelectric point of 5.29. Cluster analysis confirmed that the deduced amino acid sequence shared high identity(60–99%) with TCP-1 from other insects. To investigate Tcp-1 expression in response to abiotic stress, q PCR was used to analyze expression levels of Tcp-1 m RNA in C. suppressalis larvae exposed to temperatures ranging from –11 to 43°C. With respect to heat shock, Tcp-1 expression was higher than the control after a 2-h exposure to 30 and 36°C and declined at 39 and 43°C. Difference in Tcp-1 expression was observed at temperatures ranging from –11 to 27°C. q PCR analyses revealed that Tcp-1 expression was the highest in hindgut tissue as compared to heads, epidermis, fat body, foregut, midgut, and malpighian tubules. Our results indicated that Tcp-1 expression was differentially expressed in C. suppressalis tissues, and was impacted by temperature stress. 展开更多
关键词 TCP-1 Chilo suppressalis expression analysis temperature stress insect tissues
下载PDF
Molecular cloning, characterization and expression analysis of a catalase gene in Paphia textile 被引量:1
10
作者 WU Xiangwei LI Jiakai +1 位作者 TAN Jing LIU Xiande 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2016年第8期65-73,共9页
Catalase is an important antioxidant protein that can protect organisms against various forms of oxidative damage by eliminating hydrogen peroxide. In this study, the catalase c DNA of Paphia textile(Pt CAT) was clo... Catalase is an important antioxidant protein that can protect organisms against various forms of oxidative damage by eliminating hydrogen peroxide. In this study, the catalase c DNA of Paphia textile(Pt CAT) was cloned using RTPCR and rapid amplification of c DNA ends(RACE). Pt CAT is 1 921 bp long and consists of a 5′-UTR of 50 bp, a 3′-UTR of 349 bp, and an ORF of 1 542 bp that encodes 513 amino acids with a molecular weight of 58.4 k D and an estimated isoelectric point of 8.2. Sequence alignment indicated that Pt CAT contained a highly conserved catalytic signature motif(^(61)FNRERIPERVVHAKGAG^(77)), a proximal heme-ligand signature sequence(^(352)RLFSYSDP^(359)), and three catalytic amino acid residues(H^(72), N^(145), and Y^(356)). Pt CAT also contains two putative N-glycosylation sites(^(34)NKT^(36) and ^(437)NFT^(439)) and a peroxisome-targeting signal(^(511)AQL^(513)). Furthermore, Pt CAT shares 53%–88% identity and 29%–89% similarity with other catalase amino acid sequences. Pt CAT m RNA was present in all tested organs, including the heart, digestive gland, adductor muscle, gonad, gill, and mantle, but its expression was highest in the digestive gland. High-temperature-induced stress produced two expression patterns of Pt CAT m RNA: first, an initial up-regulation followed by a down-regulation in the heart, digestive gland, and gonad and, second, consistent down-regulation in all other organs. These results demonstrate that Pt CAT is a typical member of the catalase family and might be involved in the responses to harmful environmental factors. 展开更多
关键词 Paphia textile catalase(CAT) cloning sequence analysis expression analysis high temperature stress
下载PDF
Evaluating a satellite-based sea surface temperature by shipboard survey in the Northwest Indian Ocean
11
作者 YANG Guang HE Hailun +2 位作者 WANG Yuan HAN Xiqiu WANG Yejian 《Acta Oceanologica Sinica》 SCIE CAS CSCD 2016年第11期52-58,共7页
A summer-time shipboard meteorological survey is described in the Northwest Indian Ocean. Shipboard observations are used to evaluate a satellite-based sea surface temperature(SST), and then find the main factors th... A summer-time shipboard meteorological survey is described in the Northwest Indian Ocean. Shipboard observations are used to evaluate a satellite-based sea surface temperature(SST), and then find the main factors that are highly correlated with errors. Two satellite data, the first is remote sensing product of a microwave, which is a Tropical Rainfall Measuring Mission Microwave Imager(TMI), and the second is merged data from the microwave and infrared satellite as well as drifter observations, which is Operational Sea Surface Temperature and Sea Ice Analysis(OSTIA). The results reveal that the daily mean SST of merged data has much lower bias and root mean square error as compared with that from microwave products. Therefore the results support the necessary of the merging infrared and drifter SST with a microwave satellite for improving the quality of the SST. Furthermore, the correlation coefficient between an SST error and meteorological parameters, which include a wind speed, an air temperature, a relative humidity, an air pressure, and a visibility. The results show that the wind speed has the largest correlation coefficient with the TMI SST error. However, the air temperature is the most important factor to the OSTIA SST error. Meanwhile,the relative humidity shows the high correlation with the SST error for the OSTIA product. 展开更多
关键词 shipboard survey sea surface temperature Northwest Indian Ocean Tropical Rainfall Measuring Mission Microwave Imager Operational Sea Surface temperature and Sea Ice analysis
下载PDF
Effects of Salinity and Temperature on Bacterial Biodiversity in Hangu Solar Saltworks,China
12
作者 MA Guannan DENG Yuangao +2 位作者 DONG Jinggang Gilbert VAN STAPPEN SUI Liying 《Acta Geologica Sinica(English Edition)》 SCIE CAS CSCD 2014年第S1期91-93,共3页
1 Introduction The multi-pond solar saltworks inhabit diverse microbial groups in which a gradient of salinities range from seawater to Na Cl precipitation.Along the salinity gradient,the majority of microbial communi... 1 Introduction The multi-pond solar saltworks inhabit diverse microbial groups in which a gradient of salinities range from seawater to Na Cl precipitation.Along the salinity gradient,the majority of microbial community changes 展开更多
关键词 microbial diversity salinity temperature DGGE phylogenic analysis
下载PDF
Data processing and error analysis for the CE-1 Lunar microwave radiometer
13
作者 Jian-Qing Feng Yan Su +2 位作者 Jian-Jun Liu Yong-Liao Zou Chun-Lai Li 《Research in Astronomy and Astrophysics》 SCIE CAS CSCD 2013年第3期359-372,共14页
The microwave radiometer (MRM) onboard the Chang' E-1 (CE-I) lu- nar orbiter is a 4-frequency microwave radiometer, and it is mainly used to obtain the brightness temperature (TB) of the lunar surface, from whi... The microwave radiometer (MRM) onboard the Chang' E-1 (CE-I) lu- nar orbiter is a 4-frequency microwave radiometer, and it is mainly used to obtain the brightness temperature (TB) of the lunar surface, from which the thickness, temperature, dielectric constant and other related properties of the lunar regolith can be derived. The working mode of the CE-1 MRM, the ground calibration (including the official calibration coefficients), as well as the acquisition and processing of the raw data are introduced. Our data analysis shows that TB increases with increasing frequency, decreases towards the lunar poles and is significantly affected by solar illumination. Our analysis also reveals that the main uncertainty in TB comes from ground calibration. 展开更多
关键词 space vehicles -- instruments: microwave radiometer -- Moon: bright-ness temperature -- method: data processing -- error analysis
下载PDF
The analysis of the transient temperature distribution of double-slab Nd:YAG laser medium 被引量:1
14
作者 黄燕 孟俊清 +1 位作者 张玲玲 胡企铨 《Chinese Optics Letters》 SCIE EI CAS CSCD 2005年第3期159-162,共4页
A novel double-slab Nd:YAG laser, which uses face-pumped slab medium cooled by liquid with different temperatures on both sides, is proposed. The thermal distortion of wavefront caused by the non-uniform temperature d... A novel double-slab Nd:YAG laser, which uses face-pumped slab medium cooled by liquid with different temperatures on both sides, is proposed. The thermal distortion of wavefront caused by the non-uniform temperature distribution in the laser gain media can be self-compensated. According to the method of operation, the models of the temperature distribution and stress are presented, and the analytic solutions for the model are derived. Furthermore, the numerical simulations with pulse pumping energy of 10 J and repetition frequencies of 500 and 1000 Hz are calculated respectively for Nd:YAG laser medium. The simulation results show that the temperature gradient remains the approximative linearity, and the heat stress is within the extreme range. Then the absorption coefficient is also discussed. The result indicates that the doping concentration cannot be too large for the high repetition frequency laser. It has been proved that the high repetition frequency, high laser beam quality, and high average outp 展开更多
关键词 YAG The analysis of the transient temperature distribution of double-slab Nd ND
原文传递
Temperature Field of PC Box Girder Bridge Based on GPRS Temperature Collection System
15
作者 YANG Zeying LIU Jing +2 位作者 QU Jianbo ZHOU Xiangshan LI Lixin 《Wuhan University Journal of Natural Sciences》 CAS CSCD 2015年第3期269-276,共8页
In order to study the temperature distribution and the corresponding temperature effects on pre-stressed concrete(PC) curved box girder bridge in Shandong Province, this paper builds and adopts an automatic remote r... In order to study the temperature distribution and the corresponding temperature effects on pre-stressed concrete(PC) curved box girder bridge in Shandong Province, this paper builds and adopts an automatic remote real-time temperature collection system to collect temperature data on site, and further uses the software ANSYS for analysis. Based on the comparisons between the measured data and the simulation results, the following conclusions can be drawn: 1 Our temperature monitoring system is reliable; 2 The corresponding measured data of the web plate and flange plate exposed to the sun, vary more severely than that at other positions, so these plates need higher standard design and construction requirements; 3 In the cold wave where still is sunshine, the box girder temperature effect behaves as sine-like curve. 展开更多
关键词 bridge engineering concrete curved box girder bridge temperature distribution and temperature effect measured data and finite element analysis
原文传递
Bi-Fo time scaling method in the numerical simulation of transient conjugate heat transfer
16
作者 Yu Shi Shuiting Ding +2 位作者 Tian Qiu Chuankai Liu Shenghui Zhang 《Propulsion and Power Research》 SCIE 2021年第3期209-223,共15页
Reliable transient thermal analysis plays a very important role in the engine safety analysis.Transient conjugate heat transfer simulation is an important way of temperature analysis.But there exists a great disparity... Reliable transient thermal analysis plays a very important role in the engine safety analysis.Transient conjugate heat transfer simulation is an important way of temperature analysis.But there exists a great disparity in the time scales between solid conduction and fluid convection.The calculation cost of transient conjugate heat transfer analysis is very huge because of the tiny time step of computational fluid dynamics.The Bi-Fo time scaling method is proposed to improve the computational efficiency of transient conjugate heat transfer.On the one hand,this method carries out a similar transformation on solid heat conduction,scaling the calculation time with the product of density and specific heat capacity to maintain the consistency of Fourier number.On the other hand,it takes very short time for the fluid domain to recover stability after a boundary disturbance.Based on the above characteristic,the flow time is directly compressed to the same as that of the solid domain.It is verified by Mark II vane that increasing the solid thermal diffusivity can reduce the time scale of heat conduction.In the situation of rapidly stable flow field,scaling flow time does not affect the solid thermal boundary under corresponding dimensionless time.Within the application scope,the Bi-Fo time scaling method can greatly reduce the time cost of transient conjugate heat transfer simulation while maintaining the accuracy of transient temperature analysis. 展开更多
关键词 TRANSIENT temperature analysis Conjugate heat transfer Similar transformation Time scaling
原文传递
Spatial-temporal patterns of vegetation dynamics and their relationships to climate variations in Qinghai Lake Basin using MODIS time-series data 被引量:7
17
作者 GUO Weit NI Xiangnan +1 位作者 JING Duanyang LI Shuheng 《Journal of Geographical Sciences》 SCIE CSCD 2014年第6期1009-1021,共13页
Global warming has led to significant vegetation changes in recent years. It is necessary to investigate the effects of climatic variations(temperature and precipitation) on vegetation changes for a better understan... Global warming has led to significant vegetation changes in recent years. It is necessary to investigate the effects of climatic variations(temperature and precipitation) on vegetation changes for a better understanding of acclimation to climatic change. In this paper, we focused on the integration and application of multi-methods and spatial analysis techniques in GIS to study the spatio-temporal variation of vegetation dynamics and to explore the vegetation change mechanism. The correlations between EVI and climate factors at different time scales were calculated for each pixel including monthly, seasonal and annual scales respectively in Qinghai Lake Basin from the year of 2001 to 2012. The primary objectives of this study are to reveal when, where and why the vegetation change so as to support better understanding of terrestrial response to global change as well as the useful information and techniques for wise regional ecosystem management practices. The main conclusions are as follows:(1) Overall vegetation EVI in the region increased 6% during recent 12 years. The EVI value in growing seasons(i.e. spring and summer) exhibited very significant improving trend, accounted for 12.8% and 9.3% respectively. The spatial pattern of EVI showed obvious spatial heterogeneity which was consistent with hydrothermal condition. In general, the vegetation coverage improved in most parts of the area since nearly 78% pixel of the whole basin showed increasing trend, while degraded slightly in a small part of the area only.(2) The EVI change was positively correlated with average temperature and precipitation. Generally speaking, in Qinghai Lake Basin, precipitation was the dominant driving factor for vegetation growth; however, at different time scale its weight to vegetation has differences.(3) Based on geo-statistical analysis, the autumn precipitation has a strong correlation with the next spring EVI values in the whole region. This findings explore the autumn precipitation is an important indicator, and then, limits the plant growth of next spring. 展开更多
关键词 Qinghai Lake Basin EVI precipitation temperature correlation analysis
原文传递
上一页 1 下一页 到第
使用帮助 返回顶部