Real-time,contact-free temperature monitoring of low to medium range(30℃-150℃)has been extensively used in industry and agriculture,which is usually realized by costly infrared temperature detection methods.This pap...Real-time,contact-free temperature monitoring of low to medium range(30℃-150℃)has been extensively used in industry and agriculture,which is usually realized by costly infrared temperature detection methods.This paper proposes an alternative approach of extracting temperature information in real time from the visible light images of the monitoring target using a convolutional neural network(CNN).A mean-square error of<1.119℃was reached in the temperature measurements of low to medium range using the CNN and the visible light images.Imaging angle and imaging distance do not affect the temperature detection using visible optical images by the CNN.Moreover,the CNN has a certain illuminance generalization ability capable of detection temperature information from the images which were collected under different illuminance and were not used for training.Compared to the conventional machine learning algorithms mentioned in the recent literatures,this real-time,contact-free temperature measurement approach that does not require any further image processing operations facilitates temperature monitoring applications in the industrial and civil fields.展开更多
A dedicated weak current measurement system was designed to measure the weak currents generated by the neutron ionization chamber.This system incorporates a second-order low-pass filter circuit and the Kalman filterin...A dedicated weak current measurement system was designed to measure the weak currents generated by the neutron ionization chamber.This system incorporates a second-order low-pass filter circuit and the Kalman filtering algorithm to effectively filter out noise and minimize interference in the measurement results.Testing conducted under normal temperature conditions has demonstrated the system's high precision performance.However,it was observed that temperature variations can affect the measurement performance.Data were collected across temperatures ranging from -20 to 70℃,and a temperature correction model was established through linear regression fitting to address this issue.The feasibility of the temperature correction model was confirmed at temperatures of -5 and 40℃,where relative errors remained below 0.1% after applying the temperature correction.The research indicates that the designed measurement system exhibits excellent temperature adaptability and high precision,making it particularly suitable for measuring weak currents.展开更多
Cable-stayed bridges have been widely used in high-speed railway infrastructure.The accurate determination of cable’s representative temperatures is vital during the intricate processes of design,construction,and mai...Cable-stayed bridges have been widely used in high-speed railway infrastructure.The accurate determination of cable’s representative temperatures is vital during the intricate processes of design,construction,and maintenance of cable-stayed bridges.However,the representative temperatures of stayed cables are not specified in the existing design codes.To address this issue,this study investigates the distribution of the cable temperature and determinates its representative temperature.First,an experimental investigation,spanning over a period of one year,was carried out near the bridge site to obtain the temperature data.According to the statistical analysis of the measured data,it reveals that the temperature distribution is generally uniform along the cable cross-section without significant temperature gradient.Then,based on the limited data,the Monte Carlo,the gradient boosted regression trees(GBRT),and univariate linear regression(ULR)methods are employed to predict the cable’s representative temperature throughout the service life.These methods effectively overcome the limitations of insufficient monitoring data and accurately predict the representative temperature of the cables.However,each method has its own advantages and limitations in terms of applicability and accuracy.A comprehensive evaluation of the performance of these methods is conducted,and practical recommendations are provided for their application.The proposed methods and representative temperatures provide a good basis for the operation and maintenance of in-service long-span cable-stayed bridges.展开更多
A temperature control system of 31m vertical forced air-circulation quench furnace is proposed, which is a kind of equipment critical for thermal treatment of aluminum alloy components that are widely used in aerospac...A temperature control system of 31m vertical forced air-circulation quench furnace is proposed, which is a kind of equipment critical for thermal treatment of aluminum alloy components that are widely used in aerospace industry. For the effective operation of the furnace, it is essential to analyze the radial temperature distribution of the furnace. A set of thermodynamic balance equations modeling is established firsdy. By utilizing the numerical analysis result to modify the temperature measurements, the control accuracy and precision of the temperature are truly guaranteed. Furthermore, the multivariable decoupling self-learning PID control algorithm based on the characteristics of strong coupling between the multi-zones in the large-scaled furnace is implemented to ensure the true homogeneity of the axial temperature distribution. Finally, the redundant structure composed of industrial control computers and touch panels leads to great improvement of system reliability.展开更多
Colormetric method of images by using two different wavelength images is a new measuring method for welding temperature field on the basis of ordinary colorimetric method, which depends little on the measuring distanc...Colormetric method of images by using two different wavelength images is a new measuring method for welding temperature field on the basis of ordinary colorimetric method, which depends little on the measuring distance, emissivity of body etc. In this paper the real time measuring system and measuring principle of welding temperature field are described, the whole welding temperature field is real time measured, so the temperature distribution at the welding direction and its cross section is obtained, then parameters of thermal cycle. With data from the temperature closed loop control system of the parameters of temperature field is developed and tested. Experimental results prove that it has high measurement speed (time of a field within 0.5 s ) and good dynamic response quality. Weld penetration can be controlled satisfactorily under the variation of welding condition such as welding thickness, welding speed and weldment gap etc.展开更多
Aiming at the water temperature measuring problem for controlled cooling system of rolling plant,a new water temperature measuring method based on soft-sensing method with a water temperature model of on-line self cor...Aiming at the water temperature measuring problem for controlled cooling system of rolling plant,a new water temperature measuring method based on soft-sensing method with a water temperature model of on-line self correction parameter was built.A water temperature compensation factor model was also built to improve coiling temperature control precision.It was proved that the model meets production requirements.The soft-sensing technique has extensive applications in the field of metal forming.展开更多
To improve the accuracy of skin temperature measurements in thermal comfort research,a new measurement method based on a new thermometer is proposed.A platinum film resistance(Pt1000)sensor of the thermometer is wel...To improve the accuracy of skin temperature measurements in thermal comfort research,a new measurement method based on a new thermometer is proposed.A platinum film resistance(Pt1000)sensor of the thermometer is welded on a printed circuit board to eliminate the heat loss from the leads and avoid the influence of the surrounding thermal environment.In order to determine the suitable thickness of the board,a steady heat conduction model is established.The simulation results reveal that when the thickness of the board is 0.2 mm,the influence of the surrounding air can be effectively prevented and the skin temperature does not obviously increase.The experimental results of verification show that the maximum measurement error of the skin temperature measured by the thermometer is 0.24 ℃,and the average measurement error of the skin temperature is 0.04 ℃.The proposed method provides an effective and reliable option for the skin temperature measurement in thermal comfort research.展开更多
In the phase of the normalized COVID-19 prevention and control,non-contact temperature measurement is one of the most efficient and convenient methods for initial screening of suspected cases.In the year of 2020 in Wu...In the phase of the normalized COVID-19 prevention and control,non-contact temperature measurement is one of the most efficient and convenient methods for initial screening of suspected cases.In the year of 2020 in Wuhan,such non-contact equipment was urgently demanded,standards development in the traditional way cannot satisfy the market needs.So,the research and development of this standard for infrared intelligent body temperature measurement system was carried out in a rapid way.展开更多
Multidimensional integration and multifunctional com-ponent assembly have been greatly explored in recent years to extend Moore’s Law of modern microelectronics.However,this inevitably exac-erbates the inhomogeneity ...Multidimensional integration and multifunctional com-ponent assembly have been greatly explored in recent years to extend Moore’s Law of modern microelectronics.However,this inevitably exac-erbates the inhomogeneity of temperature distribution in microsystems,making precise temperature control for electronic components extremely challenging.Herein,we report an on-chip micro temperature controller including a pair of thermoelectric legs with a total area of 50×50μm^(2),which are fabricated from dense and flat freestanding Bi2Te3-based ther-moelectric nano films deposited on a newly developed nano graphene oxide membrane substrate.Its tunable equivalent thermal resistance is controlled by electrical currents to achieve energy-efficient temperature control for low-power electronics.A large cooling temperature difference of 44.5 K at 380 K is achieved with a power consumption of only 445μW,resulting in an ultrahigh temperature control capability over 100 K mW^(-1).Moreover,an ultra-fast cooling rate exceeding 2000 K s^(-1) and excellent reliability of up to 1 million cycles are observed.Our proposed on-chip temperature controller is expected to enable further miniaturization and multifunctional integration on a single chip for microelectronics.展开更多
Crop water stress index(CWSI)is widely used for efficient irrigation management.Precise canopy temperature(T_(c))measurement is necessary to derive a reliable CWSI.The objective of this research was to investigate the...Crop water stress index(CWSI)is widely used for efficient irrigation management.Precise canopy temperature(T_(c))measurement is necessary to derive a reliable CWSI.The objective of this research was to investigate the influences of atmospheric conditions,settled height,view angle of infrared thermography,and investigating time of temperature measuring on the performance of the CWSI.Three irrigation treatments were used to create different soil water conditions during the 2020-2021 and 2021-2022 winter wheat-growing seasons.The CWSI was calculated using the CWSI-E(an empirical approach)and CWSI-T(a theoretical approach)based on the T_(c).Weather conditions were recorded continuously throughout the experimental period.The results showed that atmospheric conditions influenced the estimation of the CWSI;when the vapor pressure deficit(VPD)was>2000 Pa,the estimated CWSI was related to soil water conditions.The height of the installed infrared thermograph influenced the T_(c)values,and the differences among the T_(c)values measured at height of 3,5,and 10 m was smaller in the afternoon than in the morning.However,the lens of the thermometer facing south recorded a higher T_(c)than those facing east or north,especially at a low height,indicating that the direction of the thermometer had a significant influence on T_(c).There was a large variation in CWSI derived at different times of the day,and the midday measurements(12:00-15:00)were the most reliable for estimating CWSI.Negative linear relationships were found between the transpiration rate and CWSI-E(R^(2)of 0.3646-0.5725)and CWSI-T(R^(2)of 0.5407-0.7213).The relations between fraction of available soil water(FASW)with CWSI-T was higher than that with CWSI-E,indicating CWSI-T was more accurate for predicting crop water status.In addition,The R^(2)between CWSI-T and FASW at 14:00 was higher than that at other times,indicating that 14:00 was the optimal time for using the CWSI for crop water status monitoring.Relative higher yield of winter wheat was obtained with average seasonal values of CWSI-E and CWSI-T around 0.23 and 0.25-0.26,respectively.The CWSI-E values were more easily influenced by meteorological factors and the timing of the measurements,and using the theoretical approach to derive the CWSI was recommended for precise irrigation water management.展开更多
This research focuses on the effects of migration on the TB infection rate and its prevention in Saudi Arabia, which has a large number of expatriates from TB-affected countries. Despite, based on the current global s...This research focuses on the effects of migration on the TB infection rate and its prevention in Saudi Arabia, which has a large number of expatriates from TB-affected countries. Despite, based on the current global statistics of TB occurrence, it is evident that the national incidence of TB has reduced from 10.55 per 100,000 in 2015 to 8.36 per 100,000 in 2019;despite this, there are still some difficulties because migrants bring new strains of Mycobacterium tuberculosis. Hindrances, including language barriers and perceived immigration status, hinder patients from seeking medical attention or doctors from diagnosing diseases. Each patient and each cultural group need special attention to public health, enhancing living circumstances, and health care support. Community participation, inclusion of TB control programs into functional healthcare facilities, and the functioning of TB programs need to be stressed to address TB issues. Considering the focus on social, economic, and cultural approaches, the country can make severe advancements in TB control and population protection. This holistic analysis is critical for a long-term effective strategy to combat TB in the Kingdom.展开更多
Non-equilibrium radiation measurements behind strong shock wave for simulated Martian atmosphere are presented in this paper. The shock wave is established in a hydrogen oxygen combustion driven shock tube. Time- reso...Non-equilibrium radiation measurements behind strong shock wave for simulated Martian atmosphere are presented in this paper. The shock wave is established in a hydrogen oxygen combustion driven shock tube. Time- resolved spectra of the Av = 0 sequence of the B^2∑^+ → X^2∑^+ electronic transition of CN have been observed through optical emission spectroscopy (OES). A new method, which is based on fitting high resolution spectrum for rotational and vibrational temperatures measurement, is proposed to diag- nose temperature distribution behind the shock wave. It is estimated that the current scheme has the maximum deviation less than 8% (lσ) for vibrational temperature measurement through detailed analysis of the influence of the uncertainties of spectroscopic constants and spectral resolution. Radiation structure of the shock layer, including induction, relaxation and equilibrium process, and corresponding rotational and vibrational temperatures are obtained through time gating OES diagnostics with sub-microsecond temporal resolution. The present extensive results will strongly benefit the reaction rate estimation and computational fluid dynamics (CFD) code validation in high enthalpy Mars reentry chemistry.展开更多
Laminaria japonica, Undaria pinnatifida, Ulva lactuca, Grateloupia turuturu and Palmaria palmata are suitable species that fit the requirements of a seaweed-animal integrated aquaculture system in terms of their viabl...Laminaria japonica, Undaria pinnatifida, Ulva lactuca, Grateloupia turuturu and Palmaria palmata are suitable species that fit the requirements of a seaweed-animal integrated aquaculture system in terms of their viable biomass, rapid growth and promising nutrient uptake rates. In this investigation, the responses of the optimal chlorophyll fluorescence yield of the five algal species in tumble culture were assessed at a temperature range of 10 - 30℃. The results revealed that Ulva lactuca was the most resistant species to high temperature, withstanding 30℃ for 4 h without apparent decline in the optimal chlorophyll fluorescence yield . While the arctic alga Palmaria palmata was the most vulnerable one, showing significant decline in the optimal chlorophyll fluorescence yield at 25℃ for 2 h. The cold-water species Laminaria japonica, however, demonstrated strong ability to cope with higher temperature (24 -26℃ ) for shorter time (within 24 h) without significant decline in the optimal chlorophyll fluorescence yield . Grateloupia turuturu showed a general decrease in the optimal chlorophyll fluorescence yield with the rising temperature from 23 to 30℃ , similar to the temperate kelp Undaria pinnatifida. Changes of chlorophyll fluorescence yields of these algae were characterized differently indicating the existence of species-unique strategy to cope with high light. Measurements of the optimal chlorophyll fluorescence yield after short exposure to direct solar irradiance revealed how long these exposures could be without significant photoinhibition or with promising recovery in photosynthetic activities. Seasonal pattern of alternation of algal species in tank culture in the Northern Hemisphere at the latitude of 36°N was proposed according to these basic measurements.展开更多
The plastic work-heat conversion coefficient is one key parameter for studying the work-heat conversion under dynamic deformation of materials. To explore this coefficient of 7075-T651 aluminum alloy under dynamic com...The plastic work-heat conversion coefficient is one key parameter for studying the work-heat conversion under dynamic deformation of materials. To explore this coefficient of 7075-T651 aluminum alloy under dynamic compression, dynamic compression experiments using the Hopkinson bar under four groups of strain rates were conducted, and the temperature signals were measured by constructing a transient infrared temperature measurement system. According to stress versus strain data as well as the corresponding temperature data obtained through the experiments, the influences of the strain and the strain rate on the coefficient of plastic work converted to heat were analyzed.The experimental results show that the coefficient of plastic work converted to heat of 7075-T651 aluminum alloy is not a constant at the range of 0.85–1 and is closely related to the strain and the strain rate. The change of internal structure of material under high strain rate reduces its energy storage capacity, and makes almost all plastic work convert into heat.展开更多
An infrared colorimetric radiation thermometrical system was established based on the theory of optical radiation. The dynamic temperature history of fuel air explosive (FAE) was measured to obtain the temperature res...An infrared colorimetric radiation thermometrical system was established based on the theory of optical radiation. The dynamic temperature history of fuel air explosive (FAE) was measured to obtain the temperature responses of primary initiation FAE and secondary initiation FAE in real time. And the characteristics of their temperature history curves were compared and analyzed. The results show that the primary initiation FAE has higher explosion temperature and longer duration compared to the secondary initiation FAE.展开更多
It is important to be able to characterize the thermal conditions over the equatorial Indian Ocean for both weather forecasting and climate prediction. This study compared the equatorial eastern Indian Ocean (EEIO) te...It is important to be able to characterize the thermal conditions over the equatorial Indian Ocean for both weather forecasting and climate prediction. This study compared the equatorial eastern Indian Ocean (EEIO) temperature and relative humidity profiles from three reanalysis products (JRA-55, MERRA2, and FGOALS-f2) with shipboard global positioning system (GPS) sounding measurements obtained during the Eastern Indian Ocean Open Cruise in spring 2018. The FGOALS-f2 reanalysis product is based on the initialization module of a sub-seasonal to seasonal prediction system with a nudging-based data assimilation method. The results indicated that:(1) both JRA-55 and MERRA2 were reliable in characterizing the temperature profile from 850 to 600 hPa, with a maximum deviation of about <0.5℃. Both datasets showed a large negative deviation below 825 hPa, with a maximum bias of about 2℃ at 1000 hPa and 1.5℃ at 900 hPa, respectively.(2) JRA-55 showed good performance in characterizing the relative humidity profile above 850 hPa, with a maximum deviation of < 8%, while it showed much wetter conditions below 850 hPa. MERRA2 overestimated the relative humidity in the middle to lower troposphere, with a maximum deviation of about 15% at 925 hPa.(3) The FGOALS-f2 reanalysis product more accurately reproduced the temperature profile in the marine atmospheric boundary layer over the EEIO than that in JRA-55 and MERRA2, but showed much wetter conditions than the GPS sounding observations, with a maximum deviation of up to 20% at 600 hPa. Future applications of GPS sounding datasets are discussed.展开更多
A novel method based on wavelength-multiplexed line-of-sight absorption and profile fitting for nonuniform flow field measurement is reported. A wavelength scanning combing laser temperature and current modulation WMS...A novel method based on wavelength-multiplexed line-of-sight absorption and profile fitting for nonuniform flow field measurement is reported. A wavelength scanning combing laser temperature and current modulation WMS scheme is used to implement the wavelength-multi- plexed-profile fitting method. Second harmonic (2f) signal of eight H20 transitions features near 7,170 cm^-1 are measured in one period using a single tunable diode laser. Spatial resolved temperature distribution upon a CH4/air premixed flat flame burner is obtained. The result validates the feasibility of strategy for non-uniform flow field diagnostics by means of WMS-2f TDLAS.展开更多
A combined computational and experimental investigation to examine temperature and soot volume fraction in coflow ethylene-air diffusion flames was presented.A numerical simulation was conducted by using a relatively ...A combined computational and experimental investigation to examine temperature and soot volume fraction in coflow ethylene-air diffusion flames was presented.A numerical simulation was conducted by using a relatively detailed gas-phase chemistry and complex thermal and transport properties coupled with a semi-empirical two-equation soot model.Thermal radiation was calculated using the discrete ordinates method.An image processing technique and a decoupled reconstruction method were used to simultaneously measure the distributions of temperature and soot volume fraction.The results show that the maximum error for temperature does not exceed 10% between the prediction and the measurement.And the maximum error is 6.9% for soot volume fraction between prediction and measurement.Additional simulations were performed to explore the effects of global equivalence ratio on diffusion flames and the soot formation.The results display that the soot formation increases with decreasing the coflow air velocity.And the soot formation in each case appears in the annular region,where the temperature ranges from about 1 000 K to 2 000 K and the profile becomes taller and wider when the coflow air is decreased.展开更多
Assimilation systems absorb both satellite measurements and Argo observations.This assimilation is essential to diagnose and evaluate the contribution from each type of data to the reconstructed analysis,allowing for ...Assimilation systems absorb both satellite measurements and Argo observations.This assimilation is essential to diagnose and evaluate the contribution from each type of data to the reconstructed analysis,allowing for better configuration of assimilation parameters.To achieve this,two comparative reconstruction schemes were designed under the optimal interpolation framework.Using a static scheme,an in situ-only field of ocean temperature was derived by correcting climatology with only Argo profiles.Through a dynamic scheme,a synthetic field was first derived from only satellite sea surface height and sea surface temperature measurements through vertical projection,and then a combined field was reconstructed by correcting the synthetic field with in situ profiles.For both schemes,a diagnostic iterative method was performed to optimize the background and observation error covariance statics.The root mean square difference(RMSD)of the in situ-only field,synthetic field and combined field were analyzed toward assimilated observations and independent observations,respectively.The rationale behind the distribution of RMSD was discussed using the following diagnostics:(1)The synthetic field has a smaller RMSD within the global mixed layer and extratropical deep waters,as in the Northwest Pacific Ocean;this is controlled by the explained variance of the vertical surface-underwater regression that reflects the ocean upper mixing and interior baroclinicity.(2)The in situ-only field has a smaller RMSD in the tropical upper layer and at midlatitudes;this is determined by the actual noise-to-signal ratio of ocean temperature.(3)The satellite observations make a more significant contribution to the analysis toward independent observations in the extratropics;this is determined by both the geographical feature of the synthetic field RMSD(smaller at depth in the extratropics)and that of the covariance correlation scales(smaller in the extratropics).展开更多
基金Project supported by the National Natural Science Foundation of China (Grant Nos.61975072 and 12174173)the Natural Science Foundation of Fujian Province,China (Grant Nos.2022H0023,2022J02047,ZZ2023J20,and 2022G02006)。
文摘Real-time,contact-free temperature monitoring of low to medium range(30℃-150℃)has been extensively used in industry and agriculture,which is usually realized by costly infrared temperature detection methods.This paper proposes an alternative approach of extracting temperature information in real time from the visible light images of the monitoring target using a convolutional neural network(CNN).A mean-square error of<1.119℃was reached in the temperature measurements of low to medium range using the CNN and the visible light images.Imaging angle and imaging distance do not affect the temperature detection using visible optical images by the CNN.Moreover,the CNN has a certain illuminance generalization ability capable of detection temperature information from the images which were collected under different illuminance and were not used for training.Compared to the conventional machine learning algorithms mentioned in the recent literatures,this real-time,contact-free temperature measurement approach that does not require any further image processing operations facilitates temperature monitoring applications in the industrial and civil fields.
基金supported by the Youth Science Foundation of Sichuan Province(Nos.2022NSFSC1230 and 2022NSFSC1231)the Science and Technology Innovation Seedling Project of Sichuan Province(No.MZGC20230080)+1 种基金the General project of the National Natural Science Foundation of China(No.12075039)the Key project of the National Natural Science Foundation of China(No.U19A2086)。
文摘A dedicated weak current measurement system was designed to measure the weak currents generated by the neutron ionization chamber.This system incorporates a second-order low-pass filter circuit and the Kalman filtering algorithm to effectively filter out noise and minimize interference in the measurement results.Testing conducted under normal temperature conditions has demonstrated the system's high precision performance.However,it was observed that temperature variations can affect the measurement performance.Data were collected across temperatures ranging from -20 to 70℃,and a temperature correction model was established through linear regression fitting to address this issue.The feasibility of the temperature correction model was confirmed at temperatures of -5 and 40℃,where relative errors remained below 0.1% after applying the temperature correction.The research indicates that the designed measurement system exhibits excellent temperature adaptability and high precision,making it particularly suitable for measuring weak currents.
基金Project(2017G006-N)supported by the Project of Science and Technology Research and Development Program of China Railway Corporation。
文摘Cable-stayed bridges have been widely used in high-speed railway infrastructure.The accurate determination of cable’s representative temperatures is vital during the intricate processes of design,construction,and maintenance of cable-stayed bridges.However,the representative temperatures of stayed cables are not specified in the existing design codes.To address this issue,this study investigates the distribution of the cable temperature and determinates its representative temperature.First,an experimental investigation,spanning over a period of one year,was carried out near the bridge site to obtain the temperature data.According to the statistical analysis of the measured data,it reveals that the temperature distribution is generally uniform along the cable cross-section without significant temperature gradient.Then,based on the limited data,the Monte Carlo,the gradient boosted regression trees(GBRT),and univariate linear regression(ULR)methods are employed to predict the cable’s representative temperature throughout the service life.These methods effectively overcome the limitations of insufficient monitoring data and accurately predict the representative temperature of the cables.However,each method has its own advantages and limitations in terms of applicability and accuracy.A comprehensive evaluation of the performance of these methods is conducted,and practical recommendations are provided for their application.The proposed methods and representative temperatures provide a good basis for the operation and maintenance of in-service long-span cable-stayed bridges.
基金It was supported by the National Natural Science Foundation of China (No. 59835170).
文摘A temperature control system of 31m vertical forced air-circulation quench furnace is proposed, which is a kind of equipment critical for thermal treatment of aluminum alloy components that are widely used in aerospace industry. For the effective operation of the furnace, it is essential to analyze the radial temperature distribution of the furnace. A set of thermodynamic balance equations modeling is established firsdy. By utilizing the numerical analysis result to modify the temperature measurements, the control accuracy and precision of the temperature are truly guaranteed. Furthermore, the multivariable decoupling self-learning PID control algorithm based on the characteristics of strong coupling between the multi-zones in the large-scaled furnace is implemented to ensure the true homogeneity of the axial temperature distribution. Finally, the redundant structure composed of industrial control computers and touch panels leads to great improvement of system reliability.
文摘Colormetric method of images by using two different wavelength images is a new measuring method for welding temperature field on the basis of ordinary colorimetric method, which depends little on the measuring distance, emissivity of body etc. In this paper the real time measuring system and measuring principle of welding temperature field are described, the whole welding temperature field is real time measured, so the temperature distribution at the welding direction and its cross section is obtained, then parameters of thermal cycle. With data from the temperature closed loop control system of the parameters of temperature field is developed and tested. Experimental results prove that it has high measurement speed (time of a field within 0.5 s ) and good dynamic response quality. Weld penetration can be controlled satisfactorily under the variation of welding condition such as welding thickness, welding speed and weldment gap etc.
基金Item Sponsored by National Natural Science Foundation of China(59995440)Doctoral Program of Higher Education Foundation of China(97014515)
文摘Aiming at the water temperature measuring problem for controlled cooling system of rolling plant,a new water temperature measuring method based on soft-sensing method with a water temperature model of on-line self correction parameter was built.A water temperature compensation factor model was also built to improve coiling temperature control precision.It was proved that the model meets production requirements.The soft-sensing technique has extensive applications in the field of metal forming.
基金The National Natural Science Foundation of China(No.50878125)
文摘To improve the accuracy of skin temperature measurements in thermal comfort research,a new measurement method based on a new thermometer is proposed.A platinum film resistance(Pt1000)sensor of the thermometer is welded on a printed circuit board to eliminate the heat loss from the leads and avoid the influence of the surrounding thermal environment.In order to determine the suitable thickness of the board,a steady heat conduction model is established.The simulation results reveal that when the thickness of the board is 0.2 mm,the influence of the surrounding air can be effectively prevented and the skin temperature does not obviously increase.The experimental results of verification show that the maximum measurement error of the skin temperature measured by the thermometer is 0.24 ℃,and the average measurement error of the skin temperature is 0.04 ℃.The proposed method provides an effective and reliable option for the skin temperature measurement in thermal comfort research.
文摘In the phase of the normalized COVID-19 prevention and control,non-contact temperature measurement is one of the most efficient and convenient methods for initial screening of suspected cases.In the year of 2020 in Wuhan,such non-contact equipment was urgently demanded,standards development in the traditional way cannot satisfy the market needs.So,the research and development of this standard for infrared intelligent body temperature measurement system was carried out in a rapid way.
基金The authors thank D.Berger,D.Hofmann and C.Kupka in IFW Dresden for helpful technical support.H.R.acknowledges funding from the DFG(Deutsche Forschungsgemeinschaft)within grant number RE3973/1-1.Q.J.,H.R.and K.N.conceived the work.With the support from N.Y.and X.J.,Q.J.and T.G.fabricated the thermoelectric films and conducted the structural and compositional characterizations.Q.J.prepared microchips and fabricated the on-chip micro temperature controllers.Q.J.and N.P.carried out the temperature-dependent material and device performance measurements.Q.J.and H.R.performed the simulation and analytical calculations.Q.J.,H.R.and K.N.wrote the manuscript with input from the other coauthors.All the authors discussed the results and commented on the manuscript.
文摘Multidimensional integration and multifunctional com-ponent assembly have been greatly explored in recent years to extend Moore’s Law of modern microelectronics.However,this inevitably exac-erbates the inhomogeneity of temperature distribution in microsystems,making precise temperature control for electronic components extremely challenging.Herein,we report an on-chip micro temperature controller including a pair of thermoelectric legs with a total area of 50×50μm^(2),which are fabricated from dense and flat freestanding Bi2Te3-based ther-moelectric nano films deposited on a newly developed nano graphene oxide membrane substrate.Its tunable equivalent thermal resistance is controlled by electrical currents to achieve energy-efficient temperature control for low-power electronics.A large cooling temperature difference of 44.5 K at 380 K is achieved with a power consumption of only 445μW,resulting in an ultrahigh temperature control capability over 100 K mW^(-1).Moreover,an ultra-fast cooling rate exceeding 2000 K s^(-1) and excellent reliability of up to 1 million cycles are observed.Our proposed on-chip temperature controller is expected to enable further miniaturization and multifunctional integration on a single chip for microelectronics.
基金supported by the Project of State Grid Hebei Electric Power Co.,Ltd.(SGHEYX00SCJS2100077).
文摘Crop water stress index(CWSI)is widely used for efficient irrigation management.Precise canopy temperature(T_(c))measurement is necessary to derive a reliable CWSI.The objective of this research was to investigate the influences of atmospheric conditions,settled height,view angle of infrared thermography,and investigating time of temperature measuring on the performance of the CWSI.Three irrigation treatments were used to create different soil water conditions during the 2020-2021 and 2021-2022 winter wheat-growing seasons.The CWSI was calculated using the CWSI-E(an empirical approach)and CWSI-T(a theoretical approach)based on the T_(c).Weather conditions were recorded continuously throughout the experimental period.The results showed that atmospheric conditions influenced the estimation of the CWSI;when the vapor pressure deficit(VPD)was>2000 Pa,the estimated CWSI was related to soil water conditions.The height of the installed infrared thermograph influenced the T_(c)values,and the differences among the T_(c)values measured at height of 3,5,and 10 m was smaller in the afternoon than in the morning.However,the lens of the thermometer facing south recorded a higher T_(c)than those facing east or north,especially at a low height,indicating that the direction of the thermometer had a significant influence on T_(c).There was a large variation in CWSI derived at different times of the day,and the midday measurements(12:00-15:00)were the most reliable for estimating CWSI.Negative linear relationships were found between the transpiration rate and CWSI-E(R^(2)of 0.3646-0.5725)and CWSI-T(R^(2)of 0.5407-0.7213).The relations between fraction of available soil water(FASW)with CWSI-T was higher than that with CWSI-E,indicating CWSI-T was more accurate for predicting crop water status.In addition,The R^(2)between CWSI-T and FASW at 14:00 was higher than that at other times,indicating that 14:00 was the optimal time for using the CWSI for crop water status monitoring.Relative higher yield of winter wheat was obtained with average seasonal values of CWSI-E and CWSI-T around 0.23 and 0.25-0.26,respectively.The CWSI-E values were more easily influenced by meteorological factors and the timing of the measurements,and using the theoretical approach to derive the CWSI was recommended for precise irrigation water management.
文摘This research focuses on the effects of migration on the TB infection rate and its prevention in Saudi Arabia, which has a large number of expatriates from TB-affected countries. Despite, based on the current global statistics of TB occurrence, it is evident that the national incidence of TB has reduced from 10.55 per 100,000 in 2015 to 8.36 per 100,000 in 2019;despite this, there are still some difficulties because migrants bring new strains of Mycobacterium tuberculosis. Hindrances, including language barriers and perceived immigration status, hinder patients from seeking medical attention or doctors from diagnosing diseases. Each patient and each cultural group need special attention to public health, enhancing living circumstances, and health care support. Community participation, inclusion of TB control programs into functional healthcare facilities, and the functioning of TB programs need to be stressed to address TB issues. Considering the focus on social, economic, and cultural approaches, the country can make severe advancements in TB control and population protection. This holistic analysis is critical for a long-term effective strategy to combat TB in the Kingdom.
文摘Non-equilibrium radiation measurements behind strong shock wave for simulated Martian atmosphere are presented in this paper. The shock wave is established in a hydrogen oxygen combustion driven shock tube. Time- resolved spectra of the Av = 0 sequence of the B^2∑^+ → X^2∑^+ electronic transition of CN have been observed through optical emission spectroscopy (OES). A new method, which is based on fitting high resolution spectrum for rotational and vibrational temperatures measurement, is proposed to diag- nose temperature distribution behind the shock wave. It is estimated that the current scheme has the maximum deviation less than 8% (lσ) for vibrational temperature measurement through detailed analysis of the influence of the uncertainties of spectroscopic constants and spectral resolution. Radiation structure of the shock layer, including induction, relaxation and equilibrium process, and corresponding rotational and vibrational temperatures are obtained through time gating OES diagnostics with sub-microsecond temporal resolution. The present extensive results will strongly benefit the reaction rate estimation and computational fluid dynamics (CFD) code validation in high enthalpy Mars reentry chemistry.
基金The"863"Hi-Tech Research and Development Program of China under contract Nos2006AA10A412 and 2006AA10A416a projectfrom the National Natural Science Foundation of China under contract No.30671596+1 种基金a project from the Chinese Academy of Sciences under contract No.KSCX2-YW-N-47-07a project from the Ministry of Science and technology of China under contract No.2006GB24910469
文摘Laminaria japonica, Undaria pinnatifida, Ulva lactuca, Grateloupia turuturu and Palmaria palmata are suitable species that fit the requirements of a seaweed-animal integrated aquaculture system in terms of their viable biomass, rapid growth and promising nutrient uptake rates. In this investigation, the responses of the optimal chlorophyll fluorescence yield of the five algal species in tumble culture were assessed at a temperature range of 10 - 30℃. The results revealed that Ulva lactuca was the most resistant species to high temperature, withstanding 30℃ for 4 h without apparent decline in the optimal chlorophyll fluorescence yield . While the arctic alga Palmaria palmata was the most vulnerable one, showing significant decline in the optimal chlorophyll fluorescence yield at 25℃ for 2 h. The cold-water species Laminaria japonica, however, demonstrated strong ability to cope with higher temperature (24 -26℃ ) for shorter time (within 24 h) without significant decline in the optimal chlorophyll fluorescence yield . Grateloupia turuturu showed a general decrease in the optimal chlorophyll fluorescence yield with the rising temperature from 23 to 30℃ , similar to the temperate kelp Undaria pinnatifida. Changes of chlorophyll fluorescence yields of these algae were characterized differently indicating the existence of species-unique strategy to cope with high light. Measurements of the optimal chlorophyll fluorescence yield after short exposure to direct solar irradiance revealed how long these exposures could be without significant photoinhibition or with promising recovery in photosynthetic activities. Seasonal pattern of alternation of algal species in tank culture in the Northern Hemisphere at the latitude of 36°N was proposed according to these basic measurements.
基金supported by the National Nature Science Foundation of China (Grants 11132011 and 11472288)
文摘The plastic work-heat conversion coefficient is one key parameter for studying the work-heat conversion under dynamic deformation of materials. To explore this coefficient of 7075-T651 aluminum alloy under dynamic compression, dynamic compression experiments using the Hopkinson bar under four groups of strain rates were conducted, and the temperature signals were measured by constructing a transient infrared temperature measurement system. According to stress versus strain data as well as the corresponding temperature data obtained through the experiments, the influences of the strain and the strain rate on the coefficient of plastic work converted to heat were analyzed.The experimental results show that the coefficient of plastic work converted to heat of 7075-T651 aluminum alloy is not a constant at the range of 0.85–1 and is closely related to the strain and the strain rate. The change of internal structure of material under high strain rate reduces its energy storage capacity, and makes almost all plastic work convert into heat.
基金Sponsored by the National Natural Science Foundation of China (10772032)
文摘An infrared colorimetric radiation thermometrical system was established based on the theory of optical radiation. The dynamic temperature history of fuel air explosive (FAE) was measured to obtain the temperature responses of primary initiation FAE and secondary initiation FAE in real time. And the characteristics of their temperature history curves were compared and analyzed. The results show that the primary initiation FAE has higher explosion temperature and longer duration compared to the secondary initiation FAE.
基金supported by funds from the National Key Research and Development Program Global Change and Mitigation Project [grant number 2017YFA0604004]the National Natural Science Foundation of China [grant numbers41675100,91737306 and U1811464]provided by the SCSIO under the project ‘Scientific investigation of the Eastern Indian Ocean in 2018’,funded by the NSFC(NORC2018-10)
文摘It is important to be able to characterize the thermal conditions over the equatorial Indian Ocean for both weather forecasting and climate prediction. This study compared the equatorial eastern Indian Ocean (EEIO) temperature and relative humidity profiles from three reanalysis products (JRA-55, MERRA2, and FGOALS-f2) with shipboard global positioning system (GPS) sounding measurements obtained during the Eastern Indian Ocean Open Cruise in spring 2018. The FGOALS-f2 reanalysis product is based on the initialization module of a sub-seasonal to seasonal prediction system with a nudging-based data assimilation method. The results indicated that:(1) both JRA-55 and MERRA2 were reliable in characterizing the temperature profile from 850 to 600 hPa, with a maximum deviation of about <0.5℃. Both datasets showed a large negative deviation below 825 hPa, with a maximum bias of about 2℃ at 1000 hPa and 1.5℃ at 900 hPa, respectively.(2) JRA-55 showed good performance in characterizing the relative humidity profile above 850 hPa, with a maximum deviation of < 8%, while it showed much wetter conditions below 850 hPa. MERRA2 overestimated the relative humidity in the middle to lower troposphere, with a maximum deviation of about 15% at 925 hPa.(3) The FGOALS-f2 reanalysis product more accurately reproduced the temperature profile in the marine atmospheric boundary layer over the EEIO than that in JRA-55 and MERRA2, but showed much wetter conditions than the GPS sounding observations, with a maximum deviation of up to 20% at 600 hPa. Future applications of GPS sounding datasets are discussed.
基金supported by the National Natural Science Foundation of China(10772188)
文摘A novel method based on wavelength-multiplexed line-of-sight absorption and profile fitting for nonuniform flow field measurement is reported. A wavelength scanning combing laser temperature and current modulation WMS scheme is used to implement the wavelength-multi- plexed-profile fitting method. Second harmonic (2f) signal of eight H20 transitions features near 7,170 cm^-1 are measured in one period using a single tunable diode laser. Spatial resolved temperature distribution upon a CH4/air premixed flat flame burner is obtained. The result validates the feasibility of strategy for non-uniform flow field diagnostics by means of WMS-2f TDLAS.
基金Projects(50806024,50806023 and 50806026) supported by the National Natural Science Foundation of China
文摘A combined computational and experimental investigation to examine temperature and soot volume fraction in coflow ethylene-air diffusion flames was presented.A numerical simulation was conducted by using a relatively detailed gas-phase chemistry and complex thermal and transport properties coupled with a semi-empirical two-equation soot model.Thermal radiation was calculated using the discrete ordinates method.An image processing technique and a decoupled reconstruction method were used to simultaneously measure the distributions of temperature and soot volume fraction.The results show that the maximum error for temperature does not exceed 10% between the prediction and the measurement.And the maximum error is 6.9% for soot volume fraction between prediction and measurement.Additional simulations were performed to explore the effects of global equivalence ratio on diffusion flames and the soot formation.The results display that the soot formation increases with decreasing the coflow air velocity.And the soot formation in each case appears in the annular region,where the temperature ranges from about 1 000 K to 2 000 K and the profile becomes taller and wider when the coflow air is decreased.
基金The National Natural Science Foundation of China under contract Nos 41706021 and 41976188。
文摘Assimilation systems absorb both satellite measurements and Argo observations.This assimilation is essential to diagnose and evaluate the contribution from each type of data to the reconstructed analysis,allowing for better configuration of assimilation parameters.To achieve this,two comparative reconstruction schemes were designed under the optimal interpolation framework.Using a static scheme,an in situ-only field of ocean temperature was derived by correcting climatology with only Argo profiles.Through a dynamic scheme,a synthetic field was first derived from only satellite sea surface height and sea surface temperature measurements through vertical projection,and then a combined field was reconstructed by correcting the synthetic field with in situ profiles.For both schemes,a diagnostic iterative method was performed to optimize the background and observation error covariance statics.The root mean square difference(RMSD)of the in situ-only field,synthetic field and combined field were analyzed toward assimilated observations and independent observations,respectively.The rationale behind the distribution of RMSD was discussed using the following diagnostics:(1)The synthetic field has a smaller RMSD within the global mixed layer and extratropical deep waters,as in the Northwest Pacific Ocean;this is controlled by the explained variance of the vertical surface-underwater regression that reflects the ocean upper mixing and interior baroclinicity.(2)The in situ-only field has a smaller RMSD in the tropical upper layer and at midlatitudes;this is determined by the actual noise-to-signal ratio of ocean temperature.(3)The satellite observations make a more significant contribution to the analysis toward independent observations in the extratropics;this is determined by both the geographical feature of the synthetic field RMSD(smaller at depth in the extratropics)and that of the covariance correlation scales(smaller in the extratropics).