Active tendon, consisting of a displacement actuator and a collocated force sensor, was first presented by Preumont and his co-workers to attenuate the vibration of large flexible space structures, and the control alg...Active tendon, consisting of a displacement actuator and a collocated force sensor, was first presented by Preumont and his co-workers to attenuate the vibration of large flexible space structures, and the control algorithm adopted by them was integral force feedback. This paper presents a new proportional-integral (PI) force feedback algorithm to achieve larger damping ratios for the structure without the requirement of structure model. Stability of the control system is shown, and simulations of a structure similar to JPL-MPI demonstrate the effectiveness of the proposed algorithm for vibration control of space structures.展开更多
In this paper, an optimal H∞ control algorithm was applied to the design of an active tendon system installed at the first story of a multi-story building to reduce its interstory drift due to earthquake excitations....In this paper, an optimal H∞ control algorithm was applied to the design of an active tendon system installed at the first story of a multi-story building to reduce its interstory drift due to earthquake excitations. To achieve optimal control performance and to guarantee the stability of the control system, an optimum strategy to select control parameters γ and α was developed. Analytical expressions of the upper and the lower bounds of γ and α were obtained for a single degree-of-freedom system with state feedback control. The selection ranges for both γ and α are graphically defined so that the controlled system is always stable and the control performance is better than by the conventional LQR control algorithm. Numerical results from a controlled three-story building under real earthquake excitations demonstrate that the peak first interstory drift can be significantly reduced with maximum control force around 10% of the building weight. An optimum design flow chart was provided. In addition, for a time-delayed structure, this study gave explicit formulae to calculate the critical values of γ and a. The system stability and control performance can thus be guaranteed even with time delay.展开更多
Traditional control strategies have difficulty handling nonlinear behavior of structures, time variable features and parameter uncertainties of structural control systems under seismic excitation. An off-and-towardseq...Traditional control strategies have difficulty handling nonlinear behavior of structures, time variable features and parameter uncertainties of structural control systems under seismic excitation. An off-and-towardsequilibrium (OTE) strategy combined with fuzzy control is presented in this paper to overcome these difficulties. According to the OTE strategy, the control force is designed from the viewpoint of a mechanical relationship between the motions of the structure, the exciting force and the control force. The advantage of the OTE strategy is that it can be used for a variety of control systems. In order to evaluate the performance of the proposed strategy, the seismic performance of a three-story shear building with an Active Tendon System (ATS) using a Fuzzy Logic Controller (FLC) is studied. The main advantage of the fuzzy controller is its inherent robustness and ability to handle any nonlinear behavior of structures. However, there are no design guidelines to set up the corresponding control rule table for a FLC. Based on the proposed strategy for the FLC, a control rule table associated with the building under study is developed, which then allows formation of a detailed algorithm. The results obtained in this study show that the proposed strategy performs slightly better than the linear quadratic regulator (LQR) strategy, while possessing several advantages over the LQR controller. Consequently, the feasibility and validity of the proposed strategy are verified.展开更多
基金the National Natural Science Foundation of China (10572070)Tsinghua Basic Research Foundation (JCqn2005029)
文摘Active tendon, consisting of a displacement actuator and a collocated force sensor, was first presented by Preumont and his co-workers to attenuate the vibration of large flexible space structures, and the control algorithm adopted by them was integral force feedback. This paper presents a new proportional-integral (PI) force feedback algorithm to achieve larger damping ratios for the structure without the requirement of structure model. Stability of the control system is shown, and simulations of a structure similar to JPL-MPI demonstrate the effectiveness of the proposed algorithm for vibration control of space structures.
基金Ministry of Education and the Science Council (NSC) of Taiwan Under the ATU plan and Grants No. NSC 95-2625-Z-005-009
文摘In this paper, an optimal H∞ control algorithm was applied to the design of an active tendon system installed at the first story of a multi-story building to reduce its interstory drift due to earthquake excitations. To achieve optimal control performance and to guarantee the stability of the control system, an optimum strategy to select control parameters γ and α was developed. Analytical expressions of the upper and the lower bounds of γ and α were obtained for a single degree-of-freedom system with state feedback control. The selection ranges for both γ and α are graphically defined so that the controlled system is always stable and the control performance is better than by the conventional LQR control algorithm. Numerical results from a controlled three-story building under real earthquake excitations demonstrate that the peak first interstory drift can be significantly reduced with maximum control force around 10% of the building weight. An optimum design flow chart was provided. In addition, for a time-delayed structure, this study gave explicit formulae to calculate the critical values of γ and a. The system stability and control performance can thus be guaranteed even with time delay.
基金National Natural Science Foundation of China Under Grants No. 50508003 and No.50478042, and A Municipal New Star Plan Program Approved by Beijing Municipal Science & Technology Commission
文摘Traditional control strategies have difficulty handling nonlinear behavior of structures, time variable features and parameter uncertainties of structural control systems under seismic excitation. An off-and-towardsequilibrium (OTE) strategy combined with fuzzy control is presented in this paper to overcome these difficulties. According to the OTE strategy, the control force is designed from the viewpoint of a mechanical relationship between the motions of the structure, the exciting force and the control force. The advantage of the OTE strategy is that it can be used for a variety of control systems. In order to evaluate the performance of the proposed strategy, the seismic performance of a three-story shear building with an Active Tendon System (ATS) using a Fuzzy Logic Controller (FLC) is studied. The main advantage of the fuzzy controller is its inherent robustness and ability to handle any nonlinear behavior of structures. However, there are no design guidelines to set up the corresponding control rule table for a FLC. Based on the proposed strategy for the FLC, a control rule table associated with the building under study is developed, which then allows formation of a detailed algorithm. The results obtained in this study show that the proposed strategy performs slightly better than the linear quadratic regulator (LQR) strategy, while possessing several advantages over the LQR controller. Consequently, the feasibility and validity of the proposed strategy are verified.
基金supported by the Fundamental Research Funds for the Central Universities (Nos. NP2022304, U22A20204)the National Natural Science Foundation of China (Nos.52105103, 52205018)。