期刊文献+
共找到27,640篇文章
< 1 2 250 >
每页显示 20 50 100
Research on Anti-Fluctuation Control of Winding Tension System Based on Feedforward Compensation
1
作者 Yujie Duan Jianguo Liang +4 位作者 Jianglin Liu Haifeng Gao Yinhui Li Jinzhu Zhang Xinyu Wen 《Computer Modeling in Engineering & Sciences》 SCIE EI 2024年第5期1239-1261,共23页
In the fiber winding process,strong disturbance,uncertainty,strong coupling,and fiber friction complicate the winding constant tension control.In order to effectively reduce the influence of these problems on the tens... In the fiber winding process,strong disturbance,uncertainty,strong coupling,and fiber friction complicate the winding constant tension control.In order to effectively reduce the influence of these problems on the tension output,this paper proposed a tension fluctuation rejection strategy based on feedforward compensation.In addition to the bias harmonic curve of the unknown state,the tension fluctuation also contains the influence of bounded noise.A tension fluctuation observer(TFO)is designed to cancel the uncertain periodic signal,in which the frequency generator is used to estimate the critical parameter information.Then,the fluctuation signal is reconstructed by a third-order auxiliary filter.The estimated signal feedforward compensates for the actual tension fluctuation.Furthermore,a time-varying parameters fractional-order PID controller(TPFOPID)is realized to attenuate the bounded noise in the fluctuation.Finally,TPFOPID is enhanced by TFO and applied to control a tension control system considering multi-source disturbances.The stability of the method is analyzed by using the Lyapunov theorem.Finally,numerical simulations verify that the proposed scheme improves the tracking ability and robustness of the system in response to tension fluctuations. 展开更多
关键词 Constant tension control anti-fluctuation strategy tension fluctuation observer time-varying parameters fractional-order PID controller feedforward compensate
下载PDF
Atomistic evaluation of tension–compression asymmetry in nanoscale body-centered-cubic AlCrFeCoNi high-entropy alloy
2
作者 邢润龙 刘雪鹏 《Chinese Physics B》 SCIE EI CAS CSCD 2024年第1期613-622,共10页
The tension and compression of face-centered-cubic high-entropy alloy(HEA) nanowires are significantly asymmetric, but the tension–compression asymmetry in nanoscale body-centered-cubic(BCC) HEAs is still unclear. In... The tension and compression of face-centered-cubic high-entropy alloy(HEA) nanowires are significantly asymmetric, but the tension–compression asymmetry in nanoscale body-centered-cubic(BCC) HEAs is still unclear. In this study,the tension–compression asymmetry of the BCC Al Cr Fe Co Ni HEA nanowire is investigated using molecular dynamics simulations. The results show a significant asymmetry in both the yield and flow stresses, with BCC HEA nanowire stronger under compression than under tension. The strength asymmetry originates from the completely different deformation mechanisms in tension and compression. In compression, atomic amorphization dominates plastic deformation and contributes to the strengthening, while in tension, deformation twinning prevails and weakens the HEA nanowire.The tension–compression asymmetry exhibits a clear trend of increasing with the increasing nanowire cross-sectional edge length and decreasing temperature. In particular, the compressive strengths along the [001] and [111] crystallographic orientations are stronger than the tensile counterparts, while the [110] crystallographic orientation shows the exactly opposite trend. The dependences of tension–compression asymmetry on the cross-sectional edge length, crystallographic orientation,and temperature are explained in terms of the deformation behavior of HEA nanowire as well as its variations caused by the change in these influential factors. These findings may deepen our understanding of the tension–compression asymmetry of the BCC HEA nanowires. 展开更多
关键词 high-entropy alloys body-centered-cubic NANOWIRE tension–compression asymmetry atomistic simulations
下载PDF
Effectivity and safety of trifocal intraocular lenses and capsular tension rings implantation for cataract patients with axial high myopia
3
作者 Shan Hua Qiu-Xia Xie +1 位作者 Hu Wang Jing-Xiang Zhong 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第3期499-508,共10页
●AIM:To assess effectivity and safety of trifocal intraocular lenses(IOLs)and capsular tension rings in treating cataract patients with axial high myopia.●METHODS:A prospective nonrandomized controlled clinical tria... ●AIM:To assess effectivity and safety of trifocal intraocular lenses(IOLs)and capsular tension rings in treating cataract patients with axial high myopia.●METHODS:A prospective nonrandomized controlled clinical trial was conducted.Totally 98 eyes(74 patients)who underwent femtosecond laser-assisted cataract surgery(FLACS)with trifocal IOLs were enrolled in the study and followed up for 2y after surgery:46 eyes(33 patients)with capsular tension ring implantation in the long axial lengths(AL)group(26<AL<29 mm)and 52 eyes(41 patients)in the normal AL group(22<AL<24.5 mm).Postoperative outcomes about effectivity and safety,including the subjective and objective visual quality,and postoperative complications were assessed.●RESULTS:Uncorrected distance visual acuity at 5 m and uncorrected intermediate visual acuity at 60 and 80 cm in the long AL group were significantly worse than those in the normal AL group at 3mo postoperatively(P<0.05).The differences in reading speed,spectacle independence and potential visual complaints between the two groups were not statistically significant(P>0.05).The dysfunctional lens index and total modulation transfer function(MTF)average height were similar between the two groups.The postoperative internal coma aberrations in the axial high myopia eyes were significantly higher than that in the normal AL group(P<0.05).The total satisfaction score in the long AL group(91.32±2.76)was slightly higher than that in the normal AL group(90.36±3.47),but there was no difference(P=0.136).A statistically negative correlation was found between corrected distance visual acuity(CDVA)and dysfunctional lens index(r=-0.382,P=0.009),and between CDVA and the total MTF average height(r=-0.374,P=0.01).But there was no significant correlation between CDVA and total satisfaction score(r=0.059,P=0.696).Postoperative complications mainly presented as posterior capsular opacity(PCO),retinal detachment and cystoid macular edema.There was no difference in the incidence of fundus disease(6.5%vs 3.8%,P=0.663)or PCO(17.4%vs 7.7%,P=0.217)between the two groups at two years.●CONCLUSION:The utilization of trifocal IOL and capsular tension ring implantation is beneficial for cataract patients with axial high myopia undergoing FLACS.This approach not only ensures excellent subjective feelings and objective visual quality,but also does not increase the incidence of postoperative complications. 展开更多
关键词 trifocal intraocular lenses capsular tension ring axial high myopia CATARACT visual quality
下载PDF
Neuroimaging in atypical normal tension glaucoma:debating routine implementation in the absence of classic neurological findings
4
作者 Umay Güvenç Gülizar Demirok +1 位作者 Güner Üney Selma Uzman 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2024年第3期509-517,共9页
●AIM:To assess the necessity of neuroimaging in patients with neurological or atypical findings of normal tension glaucoma(NTG)who do not exhibit typical glaucoma manifestations.●METHODS:A retrospective analysis was... ●AIM:To assess the necessity of neuroimaging in patients with neurological or atypical findings of normal tension glaucoma(NTG)who do not exhibit typical glaucoma manifestations.●METHODS:A retrospective analysis was conducted on 90 atypical NTG patients who underwent cranial magnetic resonance imaging(MRI)due to atypical symptoms.The demographic characteristics,clinical parameters,and radiological findings were recorded.●RESULTS:Among the patients,66.7%had abnormal radiology results,with the most common findings being gliosis(34.4%),sequelae of cerebrovascular events and vascular malformations(14.4%),and benign intracranial mass lesions(11%).Non-glaucomatous visual field defects were more frequently observed in patients with abnormal neuroimaging results.However,there were no significant differences in intraocular pressure,optic disc parameters,retinal nerve fiber layer thickness,and visual field indices between patients with normal and abnormal radiological results.The mean age of the patients was 58.74y.Interestingly,there was a significant age difference,with the abnormal radiology group having a higher median age(P=0.021).●CONCLUSION:The study highlights the importance of cranial imaging in older NTG patients to detect underlying pathologies and prevent misdiagnosis.It suggests that neuroimaging may be warranted in NTG patients with atypical visual field defects incompatible with glaucoma.However,routine neuroimaging in all NTG patients without classic neurological signs may not be necessary. 展开更多
关键词 normal tension glaucoma NEUROIMAGING atypical visual field defects
下载PDF
Unveiling the silent link:Normal-tension glaucoma's enigmatic bond with cardiac blood flow
5
作者 Prasanna Venkatesh Ramesh Arvind Kumar Morya +5 位作者 Ajanya K Aradhya Pavithra Pannerselvam Sai Thaejesvi Gopalakrishnan Shruthy Vaishali Ramesh Aji Kunnath Devadas Navaneeth Krishna 《World Journal of Cardiology》 2024年第1期10-15,共6页
This comprehensive review embarks on a captivating journey into the complex relationship between cardiology and normal-tension glaucoma(NTG),a condition that continues to baffle clinicians and researchers alike.NTG,ch... This comprehensive review embarks on a captivating journey into the complex relationship between cardiology and normal-tension glaucoma(NTG),a condition that continues to baffle clinicians and researchers alike.NTG,characterized by optic nerve damage and visual field loss despite normal intraocular pressure,has long puzzled clinicians.One emerging perspective suggests that alterations in ocular blood flow,particularly within the optic nerve head,may play a pivotal role in its pathogenesis.While NTG shares commonalities with its high-tension counterpart,its unique pathogenesis and potential ties to cardiovascular health make it a fascinating subject of exploration.It navigates through the complex web of vascular dysregulation,blood pressure and perfusion pressure,neurovascular coupling,and oxidative stress,seeking to uncover the hidden threads that tie the heart and eyes together in NTG.This review explores into the intricate mechanisms connecting cardiovascular factors to NTG,shedding light on how cardiac dynamics can influence ocular health,particularly in cases where intraocular pressure remains within the normal range.NTG's enigmatic nature,often characterized by seemingly contradictory risk factors and clinical profiles,underscores the need for a holistic approach to patient care.Drawing parallels to cardiac health,we examine into the shared vascular terrain connecting the heart and the eyes.Cardiovascular factors,including systemic blood flow,endothelial dysfunction,and microcirculatory anomalies,may exert a profound influence on ocular perfusion,impacting the delicate balance within the optic nerve head.By elucidating the subtle clues and potential associations between cardiology and NTG,this review invites clinicians to consider a broader perspective in their evaluation and management of this elusive condition.As the understanding of these connections evolves,so too may the prospects for early diagnosis and tailored interventions,ultimately enhancing the quality of life for those living with NTG. 展开更多
关键词 Normal tension glaucoma Vascular dysregulation Ocular blood flow Blood pressure Perfusion pressure Oxidative stress
下载PDF
Eudragit®-PEG Nanoparticles: Physicochemical Characterization and Interfacial Tension Measurements
6
作者 Papa Mady Sy Sidy Mouhamed Dieng +4 位作者 Alphonse Rodrigue Djiboune Louis Augustin Diaga Diouf Boucar Ndong Gora Mbaye Mounibé Diarra 《Open Journal of Biophysics》 2024年第2期121-131,共11页
The objectives of this study are to understand the mechanisms involved in the stabilization of water/oil interfaces by polymeric nanoparticles (NPs) (Eudragit®). Eudragit L100 NPs of various sizes and Zeta potent... The objectives of this study are to understand the mechanisms involved in the stabilization of water/oil interfaces by polymeric nanoparticles (NPs) (Eudragit®). Eudragit L100 NPs of various sizes and Zeta potentials were studied and compared at a water/cyclohexane model interface using a droplet tensiometer (Tracker Teclis, Longessaigne, France). The progressive interfacial adsorption of the NPs in the aqueous phase was monitored by tensiometry. The model interface was maintained and observed in a drop tensiometer, analyzed via axisymmetric drop shape analysis (ADSA), to determine the interfacial properties. Given the direct relationship between the stability of Pickering emulsions (emulsions stabilized by solid nanoparticles) and the interfacial properties of these layers, different nanoparticle systems were compared. Specifically, Eudragit NPs of different sizes were examined. Moreover, the reduction of the Zeta potential with PEG-6000 induces partial aggregation of the NPs (referred to as NP flocs), significantly impacting the stability of the interfacial layer. Dynamic surface tension measurements indicate a significant decrease in interfacial tension with Eudragit® nanoparticles (NPs). This reduction correlates with the size of the NPs, highlighting that this parameter does not operate in isolation. Other factors, such as the contact angle and wettability of the nanoparticles, also play a critical role. Notably, larger NPs further diminished the interfacial tension. This study enhances our understanding of the stability of Pickering emulsions stabilized by Eudragit® L100 polymeric nanoparticles. 展开更多
关键词 NANOPARTICLES Eudragit® PEG Interfacial tension Pickering Emulsion
下载PDF
Hubble Tension Explanation from This Cosmological Model AΛΩ (Slow Bang Model, SB)
7
作者 Jean Perron 《Journal of High Energy Physics, Gravitation and Cosmology》 CAS 2024年第1期106-125,共20页
In this article we present a model of Hubble-Lemaître law using the notions of a transmitter (galaxy) and a receiver (MW) coupled to a model of the universe (Slow Bang Model, SB), based on a quantum approach of t... In this article we present a model of Hubble-Lemaître law using the notions of a transmitter (galaxy) and a receiver (MW) coupled to a model of the universe (Slow Bang Model, SB), based on a quantum approach of the evolution of space-time as well as an equation of state that retains all the infinitesimal terms. We find an explanation of the Hubble tension H<sub>0</sub>. Indeed, we have seen that this constant depends on the transceiver pair which can vary from the lowest observable value, from photons of the CMB (theoretical [km/s/Mpc]) to increasingly higher values depending on the earlier origin of the formation of the observed galaxy or cluster (ETG ~0.3 [Gy], ~74 [km/s/Mpc]). We have produced a theoretical table of the values of the constant according to the possible pairs of transmitter/receiver in the case where these galaxies follow the Hubble flow without large disturbance. The calculated theoretical values of the constant are in the order of magnitude of all values mentioned in past studies. Subsequently, we applied the models to 9 galaxies and COMA cluster and found that the models predict acceptable values of their distances and Hubble constant since these galaxies mainly follow the Hubble flow rather than the effects of a galaxy cluster or a group of clusters. In conclusion, we affirm that this Hubble tension does not really exist and it is rather the understanding of the meaning of this constant that is questioned. 展开更多
关键词 Model of the Universe Cosmological Constant Hubble Constant Hubble’s tension Hubble-Lemaître Law Hubble’s Flow
下载PDF
A Comment on the Hubble Expansion Parameter Tension
8
作者 Bruce Hoeneisen 《International Journal of Astronomy and Astrophysics》 2024年第1期61-64,共4页
We point out that the recent baryon acoustic oscillation measurement by the Dark Energy Survey collaboration relieves the Hubble expansion parameter tension.
关键词 Hubble Parameter H0 tension
下载PDF
Regulatory mechanisms of retinal ganglion cell death in normal tension glaucoma and potential therapies 被引量:2
9
作者 Wen-Cui Shen Bing-Qing Huang Jin Yang 《Neural Regeneration Research》 SCIE CAS CSCD 2023年第1期87-93,共7页
Normal tension glaucoma(NTG)is a multifactorial optic neuropathy characterized by normal intraocular pressure,progressive retinal ganglion cell(RGC)death,and glaucomatous visual field loss.Recent studies have describe... Normal tension glaucoma(NTG)is a multifactorial optic neuropathy characterized by normal intraocular pressure,progressive retinal ganglion cell(RGC)death,and glaucomatous visual field loss.Recent studies have described the mechanisms underlying the pathogenesis of NTG.In addition to controlling intraocular pressure,neuroprotection and reduction of RGC degeneration may be beneficial therapies for NTG.In this review,we summarized the main regulatory mechanisms of RGC death in NTG,including autophagy,glutamate neurotoxicity,oxidative stress,neuroinflammation,immunity,and vasoconstriction.Autophagy can be induced by retinal hypoxia and axonal damage.In this process,ischemia can cause mutations of optineurin and activate the nuclear factor-kappa B pathway.Glutamate neurotoxicity is induced by the over-stimulation of N-methyl-D-aspartate membrane receptors by glutamate,which occurs in RGCs and induces progressive glaucomatous optic neuropathy.Oxidative stress also participates in NTG-related glaucomatous optic neuropathy.It impairs the mitochondrial and DNA function of RGCs through the apoptosis signal-regulating kinase-JUN N-terminal kinase pathway.Moreover,it increases inflammation and the immune response of RGCs.Endothelin 1 causes endothelial dysfunction and impairment of ocular blood flow,promoting vasospasm and glaucomatous optic neuropathy,as a result of NTG.In conclusion,we discussed research progress on potential options for the protection of RGCs,including TANK binding kinase 1 inhibitors regulating autophagy,N-methyl-D-aspartate receptor antagonists inhibiting glutamate toxicity,ASK1 inhibitors regulating mitochondrial function,and antioxidants inhibiting oxidative stress.In NTG,RGC death is regulated by a network of mechanisms,while various potential targets protect RGCs.Collectively,these findings provide insight into the pathogenesis of NTG and potential therapeutic strategies. 展开更多
关键词 AUTOPHAGY endothelin 1 glutamate neurotoxicity inhibitor nerve regeneration NEUROINFLAMMATION normal tension glaucoma oxidative stress retinal ganglion cell VASOCONSTRICTION
下载PDF
An ADRC Parameters Self-Tuning Control Strategy of Tension System Based on RBF Neural Network 被引量:1
10
作者 Shanhui Liu Haodi Ding +2 位作者 Ziyu Wang Li’e Ma Zheng Li 《Journal of Renewable Materials》 SCIE EI 2023年第4期1991-2014,共24页
High precision control of substrate tension is the premise and guarantee for producing high-quality products in roll-to-roll precision coating machine.However,the complex relationships in tension system make the probl... High precision control of substrate tension is the premise and guarantee for producing high-quality products in roll-to-roll precision coating machine.However,the complex relationships in tension system make the problems of decoupling control difficult to be solved,which has limited the improvement of tension control accuracy for the coating machine.Therefore,an ADRC parameters self-tuning decoupling strategy based on RBF neural network is proposed to improve the control accuracy of tension system in this paper.Firstly,a global coupling nonlinear model of the tension system is established according to the composition of the coating machine,and the global coupling model is linearized based on the first-order Taylor formula.Secondly,according to the linear model of the tension system,a parameters self-tuning decoupling algorithm of the tension system is proposed by integrating feedforward control,ADRC and RBF.Finally,the simulation results show that the proposed tension control strategy has good decoupling control performance and effectively improves the tension control accuracy for the coating machine. 展开更多
关键词 Coating machine tension system decoupling control ADRC RBF
下载PDF
Stability of neodymium:YAG laser posterior capsulotomy in eyes with capsular tension rings 被引量:1
11
作者 Yang Kyung Cho Min Sun Kim 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第6期891-896,共6页
·AIM: To evaluate the stability of neodymium(Nd):YAG laser posterior capsulotomy in eyes with capsular tension rings(CTRs).·METHODS: A total of 60 eyes that underwent cataract surgery and laser posterior cap... ·AIM: To evaluate the stability of neodymium(Nd):YAG laser posterior capsulotomy in eyes with capsular tension rings(CTRs).·METHODS: A total of 60 eyes that underwent cataract surgery and laser posterior capsulotomy postoperatively were included in this retrospective cohort study. To evaluate the safety and stability of capsulotomy, changes in the size of posterior capsulotomy and anterior chamber depth(ACD) in three groups: the group without CTR, the group with 12 mm CTRs, and the group with 13 mm CTRs, at 1wk, 3, 12, and 15mo after capsulotomy, were compared. ·RESULTS: In the group without CTR and the group with 12 mm CTR, there was no significant change in ACD at every post-laser follow-up. In the group with 13 mm CTR, the ACD change was significant until 3mo after capsulotomy. In all groups, there was a significant increase in the area of capsulotomy between 1wk and 3mo post-laser. Between 3 and 12mo post-laser, only the group with 13 mm CTR showed a significant increase in the area of capsulotomy(P<0.01). ·CONCLUSION: Laser posterior capsulotomy is safe in all three groups. The capsulotomy and ACD become stabilized and have not shown significant changes since 1y postlaser, even with larger CTRs. The maintenance of centrifugal capsular tension can last longer with larger CTRs, and the stability of the capsulotomy site can be reached about 12mo after capsulotomy in pseudophakic eyes with larger CTRs. 展开更多
关键词 Nd:YAG laser CAPSULOTOMY capsular tension ring
下载PDF
Molecular design and applications of a nanostructure green Tripodal surface active ionic liquid in enhanced oil recovery: Interfacial tension reduction, wettability alteration, and emulsification
12
作者 Mona Kharazi Javad Saien +1 位作者 Morteza Torabi Mohammad Ali Zolfigol 《Petroleum Science》 SCIE EI CAS CSCD 2023年第6期3530-3539,共10页
Surface active ionic liquids (SAILs) are considered as prominent materials in enhanced oil recovery thanks to their high interfacial activity. This study reports the preparation and applications of a nanostructure Tri... Surface active ionic liquids (SAILs) are considered as prominent materials in enhanced oil recovery thanks to their high interfacial activity. This study reports the preparation and applications of a nanostructure Tripodal imidazolium SAIL as an environmentally-friendly substitute to the conventional surfactants. The product has a star-like molecular structure centered by a triazine spacer, namely [(C_(4)im)_(3)TA][Cl_(3)], prepared by a one-step synthesis method and characterized with FT-IR, NMR, XRD, and SEM analysis methods. The interfacial tension of the system was decreased to about 78% at critical micelle concentration of less than 0.08 mol·dm^(−3). Increasing temperature, from 298.2 to 323.2 K, improved this capability. The solid surface wettability was changed from oil-wet to water-wet and 80% and 77% stable emulsions of crude oil–aqueous solutions were created after one day and one week, respectively. Compared to the Gemini kind homologous SAILs, the superior effects of the Tripodal SAIL were revealed and attributed to the strong hydrophobic branches in the molecule. The Frumkin adsorption isotherm precisely reproduced the generated IFT data, and accordingly, the adsorption and thermodynamic parameters were determined. 展开更多
关键词 Tripodal ionic liquids Green materials Enhanced oil recovery Interfacial tension WETTABILITY EMULSIFICATION
下载PDF
Antioxidant procyanidin B2 protects oocytes against cryoinjuries via mitochondria regulated cortical tension
13
作者 Qingrui Zhuan Jun Li +8 位作者 Xingzhu Du Luyao Zhang Lin Meng Yuwen Luo Dan Zhou Hongyu Liu Pengcheng Wan Yunpeng Hou Xiangwei Fu 《Journal of Animal Science and Biotechnology》 SCIE CAS CSCD 2023年第1期166-187,共22页
Background:Irreversible cryodamage caused by oocyte vitrification limited its wild application in female fertility preservation.Antioxidants were always used to antagonist the oxidative stress caused by vitrification.... Background:Irreversible cryodamage caused by oocyte vitrification limited its wild application in female fertility preservation.Antioxidants were always used to antagonist the oxidative stress caused by vitrification.However,the comprehensive mechanism underlying the protective role of antioxidants has not been studied.Procyanidin B2(PCB2)is a potent natural antioxidant and its functions in response to vitrification are still unknown.In this study,the effects of PCB2 on vitrified-thawed oocytes and subsequent embryo development were explored,and the mechanisms underlying the protective role of PCB2 were systematically elucidated.Results:Vitrification induced a marked decline in oocyte quality,while PCB2 could improve oocyte viability and further development after parthenogenetic activation.A subsequent study indicated that PCB2 effectively attenuated vitrification-induced oxidative stress,rescued mitochondrial dysfunction,and improved cell viability.Moreover,PCB2 also acts as a cortical tension regulator apart from strong antioxidant properties.Increased cortical tension caused by PCB2 would maintain normal spindle morphology and promote migration,ensure correct meiosis progression and finally reduce the aneuploidy rate in vitrified oocytes.Further study reveals that ATP biosynthesis plays a crucial role in cortical tension regulation,and PCB2 effectively increased the cortical tension through the electron transfer chain pathway.Additionally,PCB2 would elevate the cortical tension in embryo cells at morula and blastocyst stages and further improve blastocyst quality.What's more,targeted metabolomics shows that PCB2 has a beneficial effect on blastocyst formation by mediating saccharides and amino acids metabolism.Conclusions:Antioxidant PCB2 exhibits multi-protective roles in response to vitrification stimuli through mitochondria-mediated cortical tension regulation. 展开更多
关键词 Cortical tension MEIOSIS MITOCHONDRIA OOCYTES Procyanidin B2 VITRIFICATION
下载PDF
Dynamic Simulation and Test Verifcation of Hydraulic Automatic Tensioner for an Engine Timing Chain Drive System
14
作者 Zengming Feng Jinxing Yang Fei Wang 《Chinese Journal of Mechanical Engineering》 SCIE EI CAS CSCD 2023年第5期291-303,共13页
As a fundamental component of an automobile engine’s timing chain drive system, the hydraulic automatic tensioner signifcantly enhances fuel economy while minimizing system vibrations and noise. However, there is a n... As a fundamental component of an automobile engine’s timing chain drive system, the hydraulic automatic tensioner signifcantly enhances fuel economy while minimizing system vibrations and noise. However, there is a noticeable lack of research on automatic hydraulic tensioners. This study presents a comprehensive calculation approach for the principal parameters of a hydraulic automatic tensioner. An efective method, grounded in hydraulics and multibody dynamics, was introduced for estimating the dynamic response of such a tensioner. The simulation model developed for the hydraulic tensioner is characterized by its rapid dynamic response, consistent operation, and high accuracy. The dynamic behavior of the tensioner was analyzed under varying boundary conditions, using sinusoidal signal excitation. It was observed that the maximum damping force increases with a decreasing leakage gap. Conversely, an increase in oil temperature or air content leads to a decrease in the maximum damping force. The reaction forces derived from these calculations align well with experimental results. This calculation and simulation approach ofers considerable value for the design of innovative hydraulic tensioners. It not only streamlines the design phase, minimizes the number of trials, and reduces product costs, but also provides robust insights for evaluating the performance of hydraulic tensioners. 展开更多
关键词 Hydraulic automatic tensioner Timing chain Leakage gap Hysteresis curve
下载PDF
Fatigue crack propagation in fine-grained magnesium under low temperature tension-tension cyclic loading
15
作者 Qizhen Li 《Journal of Magnesium and Alloys》 SCIE EI CAS CSCD 2023年第12期4420-4430,共11页
Fine-grained magnesium was tested under stress-controlled tension-tension cyclic loading at -30 ℃ and the tested sample was observed using scanning electron microscope and electron backscatter diffraction to explore ... Fine-grained magnesium was tested under stress-controlled tension-tension cyclic loading at -30 ℃ and the tested sample was observed using scanning electron microscope and electron backscatter diffraction to explore the fatigue behavior and crack propagation. The fatigue data showed that the material experienced cyclic softening followed by cyclic hardening before the final fracture failure. The microscopic observations demonstrated that the cracks were almost perpendicular to the loading direction with some zigzags and the cracks progressed along both small angle grain boundaries and large angle grain boundaries. Although the cracks were mainly propagated along large angle grain boundaries, the value of grain boundary angle was not the primary factor to determine the crack propagation direction. The local residual strain from the rolling process was released due to the crack propagation and there was more strain relaxation at regions closer to the cracks. 展开更多
关键词 Fine-grained magnesium Fatigue properties tension Crack propagation Low temperatures
下载PDF
Seismic dynamic stability of double-slider rock slopes containing tension cracks
16
作者 ZHU Chen-hao ZHAO Lian-heng +2 位作者 HU Shi-hong ZUO Shi YU Cheng-hao 《Journal of Mountain Science》 SCIE CSCD 2023年第7期2093-2106,共14页
Earthquakes have significant impact on rock slopes,thus studying the seismic stability of double-slider rock slopes containing tension cracks is crucial.We proposed an analysis method on the seismic dynamic slope stab... Earthquakes have significant impact on rock slopes,thus studying the seismic stability of double-slider rock slopes containing tension cracks is crucial.We proposed an analysis method on the seismic dynamic slope stability.This method utilizes discrete Fourier transform to decompose real earthquake waves into a combination of harmonic waves.These waves are then used in conjunction with the pseudo-dynamic method and safety factor calculation formula to compute the safety factor.This approach accurately captures the influence of seismic time history characteristics on the dynamic stability of double-slider rock slopes containing tension cracks.The minimum safety factor in the obtained time history curves of the safety factor reflects the most unfavorable state of the slopes under seismic effects.Quantitative analysis is conducted using six sets of actual earthquake ground motion data obtained from the Pacific Earthquake Engineering Research Center’s NGAWest2 ground-shaking record database.The conclusions are as follows:(1)There is an inverse correlation between the average seismic acceleration amplitude and the minimum safety factor.Conversely,the seismic acceleration amplitude standard deviation shows a positive correlation with the minimum safety factor.The global sensitivity of geometric parameters in the slope model is higher than other influencing factors.(2)The proposed dynamic stability analysis method can capture the dynamic characteristics of earthquakes,emphasizing the minimum safety factor of the slope in the seismic time history as a stability indicator.In contrast,the pseudo-static method may yield unsafe results.(3)A safety factor expression considering hydrostatic pressure is proposed.A negative correlation was observed between the height of the water level line and the minimum safety factor. 展开更多
关键词 EARTHQUAKE Rock slope tension crack Modified Pseudo-Dynamic Method Discrete Fourier transform
下载PDF
Efficacy of surgical resection and ultra-reduced tension suture combined with superficial radiation in keloid treatment
17
作者 Xiao-Ying Hu Qiao Yang +4 位作者 Xiao-Yu Guan Jin-Ying Li Ling-Ling Wang Kun Li Xiao-Tao Zhang 《World Journal of Clinical Cases》 SCIE 2023年第35期8310-8319,共10页
BACKGROUND There are many available treatment options for keloid;however,single treatments are usually less effective.Therefore,more scientifically rational and effective com-bined treatment methods should be sought t... BACKGROUND There are many available treatment options for keloid;however,single treatments are usually less effective.Therefore,more scientifically rational and effective com-bined treatment methods should be sought to solve the pain associated with keloids.AIM To explore the efficacy and safety of surgical resection and ultra-reduced tension suture combined with superficial radiation as keloid treatment.METHODS Fifteen keloid patients admitted to Qingdao Eighth People's Hospital from June 2020 to January 2022 were enrolled in this retrospective analysis.All patients underwent a comprehensive treatment approach comprising surgical resection,ultra-reduced tension suture incision,and superficial radiation therapy within 24 h postoperatively.The modified Vancouver Scar Scale(mVSS)and Patient and Observer Scar Assessment Scale(POSAS)were used to evaluate the treatment effect,whereas the efficacy,adverse effects,and recurrence rate were observed according to the 12-mo follow-up after treatment.RESULTS The mVSS and POSAS scores at 1 and 6 mo after combination treatment decreased compared to before treatment(P<0.001),and the overall response rate was 93.3%.Only one case recurred,yielding a 6.7%recurrence rate.The incidence of local chromour sedimentation rate in 1–3 mo after radiotherapy was 33.3%(5 patients),all subsiding after 6–9 mo,without complications,such as delayed wound healing or dermatitis.CONCLUSION Surgical resection,super subtraction sutures,and superficial radiotherapy are treatment methods with short courses,low recurrence rates,and good safety profiles. 展开更多
关键词 KELOID Ultrasound suture Radiotherapeutics Superficial radiation Ultra-reduced tension suture RADIATION
下载PDF
Technique of using Cionni-modified capsular tension ring in the management of severely traumatic lens subluxation
18
作者 Hao Jiang Wei Zhang Yan-Hua Chu 《International Journal of Ophthalmology(English edition)》 SCIE CAS 2023年第7期1078-1083,共6页
AIM:To investigate the effect of Cionni-modified capsular tension ring(CTR)implantation in patients with severely traumatic subluxated cataracts.METHODS:All patients who totally had traumatic cataracts and lost zonule... AIM:To investigate the effect of Cionni-modified capsular tension ring(CTR)implantation in patients with severely traumatic subluxated cataracts.METHODS:All patients who totally had traumatic cataracts and lost zonule support and underwent cataract surgery were retrospectively analyzed.Corrected distance visual acuity(CDVA),extent of zonulysis,intraocular lens(IOL)position,intraoperative presentation,and complications were assessed.The primary outcomes included IOL centration stability and other postoperative complications.RESULTS:Twenty patients(20 eyes)were included in this study.The mean age in this study was 58.0±11.3y,and the average follow-up time was 17.3±12.8mo.Capsule bags were saved by Cionni-modified CTR.Nine eyes(45%)underwent simultaneously anterior vitrectomy due to the presence of vitreous in the anterior chamber.The preoperative mean CDVA was 0.83±0.24 log MAR,and the postoperative average CDVA was 0.23±0.30 log MAR(P<0.05).The horizontal and vertical IOL decentration after surgery was 0.27±0.12 mm and 0.41±0.19 mm,respectively;the vertical and horizontal IOL tilt after surgery was 5.5°±2.5°and 6.1°±2.2°,respectively.None of the eyes had obvious IOL decentration during the follow-up time.Eight eyes(40%)had posterior capsule opacification(PCO)that was severe enough to cause poor vision.Neodymium:YAG laser capsulotomy were performed on these eyes when the CTR was stabilized.CONCLUSION:With the help of Cionni-modified CTR,capsular bag preservation and better IOL concentration can be achieved without major complications in patients with severely traumatic subluxated cataracts. 展开更多
关键词 Cionni-modified capsular tension ring subluxated traumatic cataracts surgical technique intraocular lens decentration intraocular lens tilt
下载PDF
Investigation on the Effect of the Tension Degree of Tracks on the Adsorption Performance of Tracked Wall Climbing Robot
19
作者 Shun Xiao Guangping He +3 位作者 Jiejian Di Jie Zhang Zhonghai Zhang Lin Zhou 《Journal of Harbin Institute of Technology(New Series)》 CAS 2023年第1期52-60,共9页
In this paper,a new tracked wall climbing robot with permanent magnetic units is designed,and the tension degree of robot’s tracks is found to have a significant impact on the robot’s adsorption performance.This tra... In this paper,a new tracked wall climbing robot with permanent magnetic units is designed,and the tension degree of robot’s tracks is found to have a significant impact on the robot’s adsorption performance.This tracked wall climbing robot is a remotely controlled robot.All the control devices can be installed on the robot body.All the permanent magnetic units are arranged on the light track.In order to illustrate the relationship between the tension degree and the adsorption performance,when absorbed on the vertical surface and 180⁃degree inverted surface,the static force analysis of the robot is presented.Finally,experiments were demonstrated to prove that higher tension degree of tracks can make adsorption performance better. 展开更多
关键词 permanent magnetic adsorption TRACK tension degree wall climbing robot
下载PDF
Effect of Inclined Tension Crack on Rock Slope Stability by SSR Technique
20
作者 Ch.Venkat Ramana Niranjan Ramchandra Thote Arun Kumar Singh 《Intelligent Automation & Soft Computing》 SCIE 2023年第4期1205-1214,共10页
The tension cracks and joints in rock or soil slopes affect their failure stability.Prediction of rock or soil slope failure is one of the most challenging tasks in the earth sciences.The actual slopes consist of inho... The tension cracks and joints in rock or soil slopes affect their failure stability.Prediction of rock or soil slope failure is one of the most challenging tasks in the earth sciences.The actual slopes consist of inhomogeneous materials,complex morphology,and erratic joints.Most studies concerning the failure of rock slopes primarily focused on determining Factor of Safety(FoS)and Critical Slip Surface(CSS).In this article,the effect of inclined tension crack on a rock slope failure is studied numerically with Shear Strength Reduction Factor(SRF)method.An inclined Tension Crack(TC)influences the magnitude and location of the rock slope’s Critical Shear Strength Reduction Factor(CSRF).Certainly,inclined cracks are more prone to cause the failure of the slope than the vertical TC.Yet,all tension cracks do not lead to failure of the slope mass.The effect of the crest distance of the tension crack is also investigated.The numerical results do not show any significant change in the magnitude of CSRF unless the tip of the TC is very near to the crest of the slope.ATC is also replaced with a joint,and the results differ from the corresponding TC.These results are discussed regarding shear stress and Critical Slip Surface(CSS). 展开更多
关键词 Crest distance critical shear strength reduction factor critical slip surface inclined tension crack JOINT
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部