Replaceable flexural and shear fuse-type coupling beams are used in hybrid coupled shear wall(HCSW)systems,enabling concrete buildings to be promptly recovered after severe earthquakes.This study aimed to analytically...Replaceable flexural and shear fuse-type coupling beams are used in hybrid coupled shear wall(HCSW)systems,enabling concrete buildings to be promptly recovered after severe earthquakes.This study aimed to analytically evaluate the seismic behavior of flexural and shear fuse beams situated in short-,medium-and high-rise RC buildings that have HCSWs.Three building groups hypothetically located in a high seismic hazard zone were studied.A series of 2D nonlinear time history analyses was accomplished in OpenSees,using the ground motion records scaled at the design basis earthquake level.It was found that the effectiveness of fuses in HCSWs depends on various factors such as size and scale of the building,allowable rotation value,inter-story drift ratio,residual drift quantity,energy dissipation value of the fuses,etc.The results show that shear fuses better meet the requirements of rotations and drifts.In contrast,flexural fuses dissipate more energy,but their sectional stiffness should increase to meet other requirements.It was concluded that adoption of proper fuses depends on the overall scale of the building and on how associated factors are considered.展开更多
Aspects of the general Vlasov theory are examined separately as applied to a thin-walled channel section cantilever beam under free-end end loading. In particular, the flexural bending and shear that arise under trans...Aspects of the general Vlasov theory are examined separately as applied to a thin-walled channel section cantilever beam under free-end end loading. In particular, the flexural bending and shear that arise under transverse shear and axial torsional loading are each considered theoretically. These analyses involve the location of the shear centre at which transverse shear forces when applied do not produce torsion. This centre, when taken to be coincident with the centre of twist implies an equivalent reciprocal behaviour. That is, an axial torsion applied concentric with the shear centre will twist but not bend the beam. The respective bending and shear stress conversions are derived for each action applied to three aluminium alloy extruded channel sections mounted as cantilevers with a horizontal principal axis of symmetry. Bending and shear are considered more generally for other thin-walled sections when the transverse loading axes at the shear centre are not parallel to the section = s centroidal axes of principal second moments of area. The fixing at one end of the cantilever modifies the St Venant free angular twist and the free warping displacement. It is shown from the Wagner-Kappus torsion theory how the end constrained warping generates an axial stress distribution that varies with the length and across the cross-section for an axial torsion applied to the shear centre. It should be mentioned here for wider applications and validation of the Vlasov theory that attendant papers are to consider in detail bending and torsional loadings applied to other axes through each of the centroid and the web centre. Therein, both bending and twisting arise from transverse shear and axial torsion applied to each position being displaced from the shear centre. Here, the influence of the axis position upon the net axial and shear stress distributions is to be established. That is, the net axial stress from axial torsional loading is identified with the sum of axial stress due to bending and axial stress arising from constrained warping displacements at the fixing. The net shear stress distribution overlays the distributions from axial torsion and that from flexural shear under transverse loading. Both arise when transverse forces are displaced from the shear centre.展开更多
Efficient methods for incorporating engineering experience into the intelligent generation and optimization of shear wall structures are lacking,hindering intelligent design performance assessment and enhancement.This...Efficient methods for incorporating engineering experience into the intelligent generation and optimization of shear wall structures are lacking,hindering intelligent design performance assessment and enhancement.This study introduces an assessment method used in the intelligent design and optimization of shear wall structures that effectively combines mechanical analysis and formulaic encoding of empirical rules.First,the critical information about the structure was extracted through data structuring.Second,an empirical rule assessment method was developed based on the engineer's experience and design standards to complete a preliminary assessment and screening of the structure.Subsequently,an assessment method based on mechanical performance and material consumption was used to compare different structural schemes comprehensively.Finally,the assessment effectiveness was demonstrated using a typical case.Compared to traditional assessment methods,the proposed method is more comprehensive and significantly more efficient,promoting the intelligent transformation of structural design.展开更多
With the theoretical and technological developments related to cratonic strike-slip faults,the Shuntuoguole Low Uplift in the Tarim Basin has attracted considerable attention recently.Affected by multi-stage tectonic ...With the theoretical and technological developments related to cratonic strike-slip faults,the Shuntuoguole Low Uplift in the Tarim Basin has attracted considerable attention recently.Affected by multi-stage tectonic movements,the strike-slip faults have controlled the distribution of hydrocarbon resources owing to the special fault characteristics and fault-related structures.In contrast,the kinematics and formation mechanism of strike-slip faults in buried sedimentary basins are difficult to investigate,limiting the discussion of these faults and hydrocarbon accumulation.In this study,we identified the characteristics of massive sigmoidal tension gashes(STGs)that formed in the Shunnan area of the Tarim Basin.High-resolution three-dimensional seismic data and attribute analyses were used to investigate their geometric and kinematic characteristics.Then,the stress state of each point of the STGs was calculated using seismic curvature attributes.Finally,the formation mechanism of the STGs and their roles in controlling hydrocarbon migration and accumulation were discussed.The results suggest that:(1)the STGs developed in the Shunnan area have a wide distribution,with a tensile fault arranged in an enéchelon pattern,showing an S-shaped bending.These STGs formed in multiple stages,and differential rotation occurred along the direction of strike-slip stress during formation.(2)Near the principal displacement zone of the strike-slip faults,the stress value of the STGs was higher,gradually decreasing at both ends.The shallow layer deformation was greater than the deep layer deformation.(3)STGs are critical for connecting source rocks,migrating oil and gas,sealing horizontally,and developing efficient reservoirs.This study not only provides seismic evidence for the formation and evolution of super large STGs,but also provides certain guidance for oil and gas exploration in this area.展开更多
In this paper, a steel-concrete multi-energy dissipation composite shear wall, comprised of steel-reinforced concrete (SRC) columns, steel plate (SP) deep beams, a concrete wall and energy dissipation strips, is p...In this paper, a steel-concrete multi-energy dissipation composite shear wall, comprised of steel-reinforced concrete (SRC) columns, steel plate (SP) deep beams, a concrete wall and energy dissipation strips, is proposed. In order to study the multi-energy dissipation behavior and restorability after an earthquake, two stages of low cyclic loading tests were carded out on ten test specimens. In the first stage, test on five specimens with different number of SP deep beams was carried out, and the test lasted until the displacement drift reached 2%. In the second stage, thin SPs were welded to both sides of the five specimens tested in the first stage, and the same test was carried out on the repaired specimens (designated as new specimens). The load-bearing capacity, stiffness, ductility, hysteretic behavior and failure characteristics were analyzed for both stages and the results are discussed herein. Extrapolating from these results, strength calculation models and formulas are proposed herein and simulations using ABAQUS carried out, they show good agreement with the test results. The study demonstrates that SRC columns, SP deep beams, concrete wall and energy dissipation strips cooperate well and play an important role in energy dissipation. In addition, this study shows that the shear wall has good recoverability after an earthquake, and that the welding of thin SP's to repair a deformed wall is a practicable technique.展开更多
AIM To investigate wall shear stress(WSS) magnitude and distribution in cirrhotic patients with portal hypertension using computational fluid dynamics. METHODS Idealized portal vein(PV) system models were reconstructe...AIM To investigate wall shear stress(WSS) magnitude and distribution in cirrhotic patients with portal hypertension using computational fluid dynamics. METHODS Idealized portal vein(PV) system models were reconstructed with different angles of the PV-splenic vein(SV) and superior mesenteric vein(SMV)-SV. Patient-specific models were created according to enhanced computed tomography images. WSS was simulated by using a finite-element analyzer, regarding the blood as a Newtonian fluid and the vessel as a rigid wall. Analysis was carried out to compare the WSSin the portal hypertension group with that in healthy controls.RESULTS For the idealized models, WSS in the portal hypertension group(0-10 dyn/cm2) was significantly lower than that in the healthy controls(10-20 dyn/cm2), and low WSS area(0-1 dyn/cm2) only occurred in the left wall of the PV in the portal hypertension group. Different angles of PV-SV and SMV-SV had different effects on the magnitude and distribution of WSS, and low WSS area often occurred in smaller PV-SV angle and larger SMV-SV angle. In the patient-specific models, WSS in the cirrhotic patients with portal hypertension(10.13 ± 1.34 dyn/cm2) was also significantly lower than that in the healthy controls(P < 0.05). Low WSS area often occurred in the junction area of SV and SMV into the PV, in the area of the division of PV into left and right PV, and in the outer wall of the curving SV in the control group. In the cirrhotic patients with portal hypertension, the low WSS area extended to wider levels and the magnitude of WSS reached lower levels, thereby being more prone to disturbed flow occurrence.CONCLUSION Cirrhotic patients with portal hypertension show dramatic hemodynamic changes with lower WSS and greater potential for disturbed flow, representing a possible causative factor of PV thrombosis.展开更多
In order to further improve the seismic performance of RC shear walls, a new composite shear wall with concrete filled steel tube (CFT) columns and concealed steel trusses is proposed. This new shear wall is a doubl...In order to further improve the seismic performance of RC shear walls, a new composite shear wall with concrete filled steel tube (CFT) columns and concealed steel trusses is proposed. This new shear wall is a double composite shear wall; the first composite being the use of three different force systems, CFT, steel truss and shear wall, and the second the use of two different materials, steel and concrete. Three 1/5 scaled experimental specimens: a traditional RC shear wall, a shear wall with CFT columns, and a shear wall with CFT columns and concealed steel trusses, were tested under cyclic loading and the seismic performance indices of the shear walls were comparatively analyzed. Based on the data from these experiments, a thorough elastic-plastic finite element analysis and parametric analysis of the new shear walls were carried out using ABAQUS software. The finite element results of deformation, stress distribution, and the evolution of cracks in each phase were compared with the experimental results and showed good agreement. A mechanical model was also established for calculating the load-carrying capacity of the new composite shear walls. The results show that this new type of shear wall has improved seismic performance over the other two types of shear wails tested.展开更多
The authors investigate the failure modes surrounding over-stressed tunnels in rock.Three lines of investigation are employed:failure in over-stressed three-dimensional(3D) models of tunnels bored under 3D stress,fail...The authors investigate the failure modes surrounding over-stressed tunnels in rock.Three lines of investigation are employed:failure in over-stressed three-dimensional(3D) models of tunnels bored under 3D stress,failure modes in two-dimensional(2D) numerical simulations of 1000 m and 2000 m deep tunnels using FRACOD,both in intact rock and in rock masses with one or two joint sets,and finally,observations in TBM(tunnel boring machine) tunnels in hard and medium hard massive rocks.The reason for 'stress-induced' failure to initiate,when the assumed maximum tangential stress is approximately(0.4-0.5)σ_c(UCS,uniaxial compressive strength) in massive rock,is now known to be due to exceedance of a critical extensional strain which is generated by a Poisson's ratio effect.However,because similar 'stress/strength' failure limits are found in mining,nuclear waste research excavations,and deep road tunnels in Norway,one is easily misled into thinking of compressive stress induced failure.Because of this,the empirical SRF(stress reduction factor in the Q-system) is set to accelerate as the estimated ratio σ_(θmax)/σ_c >> 0.4.In mining,similar 'stress/strength' ratios are used to suggest depth of break-out.The reality behind the fracture initiation stress/strength ratio of '0.4' is actually because of combinations of familiar tensile and compressive strength ratios(such as 10) with Poisson's ratio(say0.25).We exceed the extensional strain limits and start to see acoustic emission(AE) when tangential stress σθ ≈ 0.4σc,due to simple arithmetic.The combination of 2D theoretical FRACOD models and actual tunnelling suggests frequent initiation of failure by 'stable' extensional strain fracturing,but propagation in 'unstable' and therefore dynamic shearing.In the case of very deep tunnels(and 3D physical simulations),compressive stresses may be too high for extensional strain fracturing,and shearing will dominate,both ahead of the face and following the face.When shallower,the concept of 'extensional strain initiation but propagation' in shear is suggested.The various failure modes are richly illustrated,and the inability of conventional continuum modelling is emphasized,unless cohesion weakening and friction mobilization at different strain levels are used to reach a pseudo state of yield,but still considering a continuum.展开更多
The magnetohydrodynamics laws govern the motion of a conducting fluid, such as blood, in an externally applied static magnetic field B0. When an artery is exposed to a magnetic field, the blood charged particles are d...The magnetohydrodynamics laws govern the motion of a conducting fluid, such as blood, in an externally applied static magnetic field B0. When an artery is exposed to a magnetic field, the blood charged particles are deviated by the Lorentz force thus inducing electrical currents and voltages along the vessel walls and in the neighboring tissues. Such a situation may occur in several biomedical applications: magnetic resonance imaging (MRI), magnetic drug transport and targeting, tissue engineering… In this paper, we consider the steady unidirectional blood flow in a straight circular rigid vessel with non-conducting walls, in the presence of an exterior static magnetic field. The exact solution of Gold (1962) (with the induced fields not neglected) is revisited. It is shown that the integration over a cross section of the vessel of the longitudinal projection of the Lorentz force is zero, and that this result is related to the existence of current return paths, whose contributions compensate each other over the section. It is also demonstrated that the classical definition of the shear stresses cannot apply in this situation of magnetohydrodynamic flow, because, due to the existence of the Lorentz force, the axisymmetry is broken.展开更多
A composite shear wall concept based on concrete filled steel tube (CFST) columns and steel plate (SP) deep beams is proposed and examined in this study. The new wall is composed of three different energy dissipat...A composite shear wall concept based on concrete filled steel tube (CFST) columns and steel plate (SP) deep beams is proposed and examined in this study. The new wall is composed of three different energy dissipation elements: CFST columns; SP deep beams; and reinforced concrete (RC) strips. The RC strips are intended to allow the core structural elements - the CFST columns and SP deep beams - to work as a single structure to consume energy. Six specimens of different configurations were tested under cyclic loading. The resulting data are analyzed herein. In addition, numerical simulations of the stress and damage processes for each specimen were carried out, and simulations were completed for a range of location and span-height ratio variations for the SP beams. The simulations show good agreement with the test results. The core structure exhibits a ductile yielding mechanism characteristic of strong column-weak beam structures, hysteretic curves are plump and the composite shear wall exhibits several seismic defense lines. The deformation of the shear wall specimens with encased CFST column and SP deep beam design appears to be closer to that of entire shear walls. Establishing optimal design parameters for the configuration of SP deep beams is pivotal to the best seismic behavior of the wall. The new composite shear wall is therefore suitable for use in the seismic design of building structures.展开更多
A method is developed to predict the lateral load-carrying capacity of composite shear walls with double steel plates and filled concrete with binding bars(SCBs). Nonlinear finite element models of SCBs were establish...A method is developed to predict the lateral load-carrying capacity of composite shear walls with double steel plates and filled concrete with binding bars(SCBs). Nonlinear finite element models of SCBs were established by using the finite element tool, Abaqus. Tie constraints were used to connect the binding bars and the steel plates. Surface-to-surface contact provided by the Abaqus was used to simulate the interaction between the steel plate and the core concrete. The established models could predict the lateral load-carrying capacity of SCBs with a reasonable degree of accuracy. A calculation method was developed by superposition principle to predict the lateral load-carrying capacity of SCBs for the engineering application. The concrete confined by steel plates and binding bars is under multi-axial compression; therefore, its shear strength was calculated by using the Guo-Wang concrete failure criterion. The shear strength of the steel plates of SCBs was calculated by using the von Mises yielding criterion without considering buckling. Results of the developed method are in good agreement with the testing and finite element results.展开更多
To study the seismic performance and load-transferring mechanism of an innovative precast shear wall(IPSW) involving vertical joints, an experimental investigation and theoretical analysis were successively conducted ...To study the seismic performance and load-transferring mechanism of an innovative precast shear wall(IPSW) involving vertical joints, an experimental investigation and theoretical analysis were successively conducted on two test walls. The test results confirm the feasibility of the novel joints as well as the favorable seismic performance of the walls, even though certain optimization measures should be taken to improve the ductility. The load-transferring mechanism subsequently is theoretically investigated based on the experimental study. The theoretical results show the load-transferring route of the novel joints is concise and definite. During the elastic stage, the vertical shear stress in the connecting steel frame(CSF) distributes uniformly; and each high-strength bolt(HSB)primarily delivers vertical shear force. However, the stress in the CSF redistributes when the walls develop into the elastic-plastic stage. At the ultimate state, the vertical shear stress and horizontal normal stress in the CSF distribute linearly; and the HSBs at both ends of the CSF transfer the maximum shear forces.展开更多
The alternative types of composite structure made of wood and cement based building materials needs to meet with the high demand for earthquake-resistant houses in Indonesia. In order to understand the mechanism of ea...The alternative types of composite structure made of wood and cement based building materials needs to meet with the high demand for earthquake-resistant houses in Indonesia. In order to understand the mechanism of earthquake resisting performance of shear wall, it is necessary to investigate not only elastic behavior of shear walls but also non-linear one. In this study, series of full-scale experiments on timber frame shear walls composed of Akasia wood (Acacia mangium) sheathed by Fiber Cement Board (FCB) were carried out. For predicting skeleton curve, a series of theoretical equations was derived, which cannot only solve arbitrary nail pattern shear wall but also nonlinear behavior after yielding. Further, for describing hysteresis loops of shear walls, so-called Normalized Cyclic Loop (NCL) model was adopted. By combining two theoretical approaches, weintended to predict whole cyclic shear wall behaviors tested. Good agreements were obtained from comparison between experiment and prediction. The information obtain by this study will be useful for practical engineers or structural designers to design the high performance earthquake resisting timber houses.展开更多
A new type of ductile lowrise shearwall with many short horizontalkeyways is proposed in this paper in order to improve the earthquake resistant behav-ior of ordinary lowrise shearwall.The behavior of this wall is stu...A new type of ductile lowrise shearwall with many short horizontalkeyways is proposed in this paper in order to improve the earthquake resistant behav-ior of ordinary lowrise shearwall.The behavior of this wall is studied through low-frequency cyclic loading test.Based on the test results,the paper puts forward thedifferent restoring force models for different lowrise shearwalls,and a program fortheir nonlinear dynamic analysis is worked out.Thr(?)h directly inputting earth-quake waves,the paper analyses the dynamic response and energy dissipation of 3types of lowrise shearwalls.The calculation results dem(?)strate that the newly de-vised ductile shearwall has good earthquake resistant behavior.展开更多
To investigate the feasibility and seismic performance of the horizontal joints in an innovative precast shear wall system, two test walls were fabricated, and the monotonic and cyclic loading tests were performed on ...To investigate the feasibility and seismic performance of the horizontal joints in an innovative precast shear wall system, two test walls were fabricated, and the monotonic and cyclic loading tests were performed on the two test walls, respectively. Then, the lateral load-top displacement curves, load beating capacity, ductility, lateral stiffness, strains of steel bars, strain distribution on the connecting steel frame (CSF), and relative slippages between the CSF and embedded limbic steel frame (ELSF) were discussed in detail. The test results show that the load bearing capacity and ductility of the test wall are both favorable with a displacement ductility factor of more than 3.7. The normal and shear stresses in the CSF except for the compression end are far smaller than the yield stresses throughout the test procedure. Certain slippages of about 1.13 mm occurs between the CSF and ELSF on the compression side of the test wall, while almost no slippages occurs on the tension side. The seismic performance of the test wall is favorable and the new-type scheme of the horizontal joints is both feasible and reliable.展开更多
For a deeper understanding of the shear resistance performance of the steel-concrete-steel composite shear wall, the main influence factors such as the thicknesses of the steel plates and the concrete, the strength gr...For a deeper understanding of the shear resistance performance of the steel-concrete-steel composite shear wall, the main influence factors such as the thicknesses of the steel plates and the concrete, the strength grades of the concrete and the span-depth ratios of the composite wall, which have impacts on the shear resistance performance of the composite shear wail, are analyzed by the numerical simulation method. Meanwhile, the simplified calculation formulae of the initial elastic lateral-resisting stiffness and the shear bearing capacity of the composite shear wall are also proposed. The research shows that with the increase in the thicknesses of the steel plates and the concrete and the increase in the strength grades of the concrete, the shear performance of the shear wall improves obviously; the span-depth ratios of the composite wall have a significant effect on the initial elastic lateral- resisting stiffness, but a small effect on the shear bearing capacity. Comparing the results of the simplified calculation formulae with those of the nonlinear finite element method, it is obvious that the presented formulae are reasonable and meet the real force state of the structure. These conclusions can serve as a preliminary design reference for the steel-concrete- steel composite shear wall.展开更多
The shear wall with and without openings that served as a structural element or/and partition wall was utilized in a low-cost housing for the low-income people in Indonesia. The houses,however,should be withstoodfrom ...The shear wall with and without openings that served as a structural element or/and partition wall was utilized in a low-cost housing for the low-income people in Indonesia. The houses,however,should be withstoodfrom earthquake inertial force, so there must be no casualties when disaster struck. The alternative types of composite structure made of wood and cement based building materials needed to meet with the high demand for earthquake-resistant houses in Indonesia. In order to understand the mechanism of earthquake resisting performance of shear wall, we needs to investigate behavior of shear wallsnot only for cyclic static but alsofor dynamic loading. In this study, theseries of full-scale experiment on timber frame shear walls with and without openings,compose of Laminated Veneer Lumber (LVL) engineered wood (Paraserianthes Falcatariaand Hevea Brasiliensis) and sheathed by Fiber Cement Board (FCB), was carried out.By analyzing testing result using theoretical approaches, we intended to predict static initial stiffness and yielding strength as well as basic dynamic properties shear walls. For static behavior, good agreements were obtain from comparison between experiment and theoretical prediction based on mechanical model. While, for dynamic behavior, agreement was not sufficient due tothe effect of bending and rocking of actual test specimens. The information obtain by this study will be useful for practical engineers or structural designers to design the high performance earthquake resisting timber houses with a low construction cost.展开更多
The work presents the results of tests on the shear parameters of walls made of AAC (autoclaved aerated concrete, fb = 4.0 N/mm2) on the system mortar for thin M5 and M10 joints (fm = 6.1 N/mm2 and fro = 11.9 N/mm2...The work presents the results of tests on the shear parameters of walls made of AAC (autoclaved aerated concrete, fb = 4.0 N/mm2) on the system mortar for thin M5 and M10 joints (fm = 6.1 N/mm2 and fro = 11.9 N/mm2) and on polyurethane glue and also walls without mortar (dry masonry). The wall compression strength (on mortar M5 class) (per EN 1052-1:2000) amounted tofc,mv= 2.97 N/mm2 (fk = 2.48 N/mm2), elastic modulus was Ecru = 2,040 N/mm2. Various structure of bed joints and head joints were applied and the following were used as reinforcement: steel trusses of EFZ 140/Z 140 type (Z1 type) and meshes made of plastics (Z2 type). Based on the tests carried out with regard to unreinforced elements, it was shown that the filling in of head joints with mortar had an advantageous effect on the values of cracking and destruction stresses. While, with the use of reinforcement, advantageous increase of stress was obtained only when the mortar was laid twice on both bed surfaces of masonry units. The application of reinforcement in the bed joints when the mortar was laid only on one bed joints surface of the masonry units reduced the values of cracking and destruction stresses in relation to the values obtained in the unreinforced walls.展开更多
The equations of the lateral deflection curve of the short pier shear wall under a lateral concentrated load at any level are derived by employing a continuous approach. Lateral flexibility matrixes for the dynamic an...The equations of the lateral deflection curve of the short pier shear wall under a lateral concentrated load at any level are derived by employing a continuous approach. Lateral flexibility matrixes for the dynamic analysis are also obtained by repeatedly calculating the lateral unit load on the wall at each level where a lumped mass located. Dynamic analyses are implemented for short pier shear walls with different parameters, called the integrative coefficient and the pier strength coefficient related to the dimensions of walls. The influences of two coefficients on the dynamic performances of the structure are studied. Results indicate that with the increase of the integrative coefficient, the periods of top two modes apparently decrease but the other periods of higher frequency modes show little variation when the pier strength coefficient remains constant. Similarly, if the integrative coefficient is constant, the top two periods of the free vibration decrease with the increase of the integrative coefficient but the other periods of higher frequency modes show less variation.展开更多
Inthis paper, each of the two phases in dense two-phase flow is considered as continuous medium and the fundamental equations for two-phase flow arc described in Eulerian form. The generalized constitutive relation of...Inthis paper, each of the two phases in dense two-phase flow is considered as continuous medium and the fundamental equations for two-phase flow arc described in Eulerian form. The generalized constitutive relation of the Bingham fluid is applied to the dispersed phase with the analysis oj physical mechanism of dense two-phase flow. The shearing stress of dispersed phase at a wall is used to give a boundary condition. Then a mathematical model for dense two-phase flow is obtained. In addition, the expressions of shearing stress of dispersed phase at a wall is derived according to the fundamental model of the friclional collision between dispersed-plutse particles and the wall.展开更多
文摘Replaceable flexural and shear fuse-type coupling beams are used in hybrid coupled shear wall(HCSW)systems,enabling concrete buildings to be promptly recovered after severe earthquakes.This study aimed to analytically evaluate the seismic behavior of flexural and shear fuse beams situated in short-,medium-and high-rise RC buildings that have HCSWs.Three building groups hypothetically located in a high seismic hazard zone were studied.A series of 2D nonlinear time history analyses was accomplished in OpenSees,using the ground motion records scaled at the design basis earthquake level.It was found that the effectiveness of fuses in HCSWs depends on various factors such as size and scale of the building,allowable rotation value,inter-story drift ratio,residual drift quantity,energy dissipation value of the fuses,etc.The results show that shear fuses better meet the requirements of rotations and drifts.In contrast,flexural fuses dissipate more energy,but their sectional stiffness should increase to meet other requirements.It was concluded that adoption of proper fuses depends on the overall scale of the building and on how associated factors are considered.
文摘Aspects of the general Vlasov theory are examined separately as applied to a thin-walled channel section cantilever beam under free-end end loading. In particular, the flexural bending and shear that arise under transverse shear and axial torsional loading are each considered theoretically. These analyses involve the location of the shear centre at which transverse shear forces when applied do not produce torsion. This centre, when taken to be coincident with the centre of twist implies an equivalent reciprocal behaviour. That is, an axial torsion applied concentric with the shear centre will twist but not bend the beam. The respective bending and shear stress conversions are derived for each action applied to three aluminium alloy extruded channel sections mounted as cantilevers with a horizontal principal axis of symmetry. Bending and shear are considered more generally for other thin-walled sections when the transverse loading axes at the shear centre are not parallel to the section = s centroidal axes of principal second moments of area. The fixing at one end of the cantilever modifies the St Venant free angular twist and the free warping displacement. It is shown from the Wagner-Kappus torsion theory how the end constrained warping generates an axial stress distribution that varies with the length and across the cross-section for an axial torsion applied to the shear centre. It should be mentioned here for wider applications and validation of the Vlasov theory that attendant papers are to consider in detail bending and torsional loadings applied to other axes through each of the centroid and the web centre. Therein, both bending and twisting arise from transverse shear and axial torsion applied to each position being displaced from the shear centre. Here, the influence of the axis position upon the net axial and shear stress distributions is to be established. That is, the net axial stress from axial torsional loading is identified with the sum of axial stress due to bending and axial stress arising from constrained warping displacements at the fixing. The net shear stress distribution overlays the distributions from axial torsion and that from flexural shear under transverse loading. Both arise when transverse forces are displaced from the shear centre.
文摘Efficient methods for incorporating engineering experience into the intelligent generation and optimization of shear wall structures are lacking,hindering intelligent design performance assessment and enhancement.This study introduces an assessment method used in the intelligent design and optimization of shear wall structures that effectively combines mechanical analysis and formulaic encoding of empirical rules.First,the critical information about the structure was extracted through data structuring.Second,an empirical rule assessment method was developed based on the engineer's experience and design standards to complete a preliminary assessment and screening of the structure.Subsequently,an assessment method based on mechanical performance and material consumption was used to compare different structural schemes comprehensively.Finally,the assessment effectiveness was demonstrated using a typical case.Compared to traditional assessment methods,the proposed method is more comprehensive and significantly more efficient,promoting the intelligent transformation of structural design.
基金Thanks to the Northwest Oilfield Branch,SINOPEC,for providing the seismic data.We thank Dr.Yi-Duo Liu of University of Houston,Ying-Chang Cao and Fang Hao of China University of Petroleum(East China)for their constructive suggestions of this manuscript.We also thank two anonymous reviewers for their comments that helped us to improve the manuscript.This research is jointly supported by the National Natural Science Foundation of China(No.42272155)the Strategic Priority Research Program of the Chinese Academy of Sciences(No.XDA14010301)+1 种基金the Science Fund for Creative Research Groups of the National Natural Science Foundation of China(Grant No.41821002)National Natural Science Foundation of China(No.41702138).
文摘With the theoretical and technological developments related to cratonic strike-slip faults,the Shuntuoguole Low Uplift in the Tarim Basin has attracted considerable attention recently.Affected by multi-stage tectonic movements,the strike-slip faults have controlled the distribution of hydrocarbon resources owing to the special fault characteristics and fault-related structures.In contrast,the kinematics and formation mechanism of strike-slip faults in buried sedimentary basins are difficult to investigate,limiting the discussion of these faults and hydrocarbon accumulation.In this study,we identified the characteristics of massive sigmoidal tension gashes(STGs)that formed in the Shunnan area of the Tarim Basin.High-resolution three-dimensional seismic data and attribute analyses were used to investigate their geometric and kinematic characteristics.Then,the stress state of each point of the STGs was calculated using seismic curvature attributes.Finally,the formation mechanism of the STGs and their roles in controlling hydrocarbon migration and accumulation were discussed.The results suggest that:(1)the STGs developed in the Shunnan area have a wide distribution,with a tensile fault arranged in an enéchelon pattern,showing an S-shaped bending.These STGs formed in multiple stages,and differential rotation occurred along the direction of strike-slip stress during formation.(2)Near the principal displacement zone of the strike-slip faults,the stress value of the STGs was higher,gradually decreasing at both ends.The shallow layer deformation was greater than the deep layer deformation.(3)STGs are critical for connecting source rocks,migrating oil and gas,sealing horizontally,and developing efficient reservoirs.This study not only provides seismic evidence for the formation and evolution of super large STGs,but also provides certain guidance for oil and gas exploration in this area.
基金Beijing Natural Science Foundation of China under Grant No.8122004the National Natural Science Foundation of China under Grant No.51178010the National Science and Technology Support Program of China under Grant No.2012BAJ13B02
文摘In this paper, a steel-concrete multi-energy dissipation composite shear wall, comprised of steel-reinforced concrete (SRC) columns, steel plate (SP) deep beams, a concrete wall and energy dissipation strips, is proposed. In order to study the multi-energy dissipation behavior and restorability after an earthquake, two stages of low cyclic loading tests were carded out on ten test specimens. In the first stage, test on five specimens with different number of SP deep beams was carried out, and the test lasted until the displacement drift reached 2%. In the second stage, thin SPs were welded to both sides of the five specimens tested in the first stage, and the same test was carried out on the repaired specimens (designated as new specimens). The load-bearing capacity, stiffness, ductility, hysteretic behavior and failure characteristics were analyzed for both stages and the results are discussed herein. Extrapolating from these results, strength calculation models and formulas are proposed herein and simulations using ABAQUS carried out, they show good agreement with the test results. The study demonstrates that SRC columns, SP deep beams, concrete wall and energy dissipation strips cooperate well and play an important role in energy dissipation. In addition, this study shows that the shear wall has good recoverability after an earthquake, and that the welding of thin SP's to repair a deformed wall is a practicable technique.
基金Supported by the Program for Changjiang Scholars and Innovative Research Team in Universities,No.PCSIRT-1171National Natural Science Foundation of China,No.81270504Fundamental Research Funds for the Central Universities,No.xjj20100209
文摘AIM To investigate wall shear stress(WSS) magnitude and distribution in cirrhotic patients with portal hypertension using computational fluid dynamics. METHODS Idealized portal vein(PV) system models were reconstructed with different angles of the PV-splenic vein(SV) and superior mesenteric vein(SMV)-SV. Patient-specific models were created according to enhanced computed tomography images. WSS was simulated by using a finite-element analyzer, regarding the blood as a Newtonian fluid and the vessel as a rigid wall. Analysis was carried out to compare the WSSin the portal hypertension group with that in healthy controls.RESULTS For the idealized models, WSS in the portal hypertension group(0-10 dyn/cm2) was significantly lower than that in the healthy controls(10-20 dyn/cm2), and low WSS area(0-1 dyn/cm2) only occurred in the left wall of the PV in the portal hypertension group. Different angles of PV-SV and SMV-SV had different effects on the magnitude and distribution of WSS, and low WSS area often occurred in smaller PV-SV angle and larger SMV-SV angle. In the patient-specific models, WSS in the cirrhotic patients with portal hypertension(10.13 ± 1.34 dyn/cm2) was also significantly lower than that in the healthy controls(P < 0.05). Low WSS area often occurred in the junction area of SV and SMV into the PV, in the area of the division of PV into left and right PV, and in the outer wall of the curving SV in the control group. In the cirrhotic patients with portal hypertension, the low WSS area extended to wider levels and the magnitude of WSS reached lower levels, thereby being more prone to disturbed flow occurrence.CONCLUSION Cirrhotic patients with portal hypertension show dramatic hemodynamic changes with lower WSS and greater potential for disturbed flow, representing a possible causative factor of PV thrombosis.
基金Science and Technology Key Project of Beijing Under Grant No.D0905060370000National Natural Science Foundation of China Under Grant No.50878007+1 种基金Project High-level Personnel in Beijing Under Grant No.PHR20100502the Scientific and Technological Planning of Beijing Key Project Education Commission Under Grant No.KZ200910005008
文摘In order to further improve the seismic performance of RC shear walls, a new composite shear wall with concrete filled steel tube (CFT) columns and concealed steel trusses is proposed. This new shear wall is a double composite shear wall; the first composite being the use of three different force systems, CFT, steel truss and shear wall, and the second the use of two different materials, steel and concrete. Three 1/5 scaled experimental specimens: a traditional RC shear wall, a shear wall with CFT columns, and a shear wall with CFT columns and concealed steel trusses, were tested under cyclic loading and the seismic performance indices of the shear walls were comparatively analyzed. Based on the data from these experiments, a thorough elastic-plastic finite element analysis and parametric analysis of the new shear walls were carried out using ABAQUS software. The finite element results of deformation, stress distribution, and the evolution of cracks in each phase were compared with the experimental results and showed good agreement. A mechanical model was also established for calculating the load-carrying capacity of the new composite shear walls. The results show that this new type of shear wall has improved seismic performance over the other two types of shear wails tested.
文摘The authors investigate the failure modes surrounding over-stressed tunnels in rock.Three lines of investigation are employed:failure in over-stressed three-dimensional(3D) models of tunnels bored under 3D stress,failure modes in two-dimensional(2D) numerical simulations of 1000 m and 2000 m deep tunnels using FRACOD,both in intact rock and in rock masses with one or two joint sets,and finally,observations in TBM(tunnel boring machine) tunnels in hard and medium hard massive rocks.The reason for 'stress-induced' failure to initiate,when the assumed maximum tangential stress is approximately(0.4-0.5)σ_c(UCS,uniaxial compressive strength) in massive rock,is now known to be due to exceedance of a critical extensional strain which is generated by a Poisson's ratio effect.However,because similar 'stress/strength' failure limits are found in mining,nuclear waste research excavations,and deep road tunnels in Norway,one is easily misled into thinking of compressive stress induced failure.Because of this,the empirical SRF(stress reduction factor in the Q-system) is set to accelerate as the estimated ratio σ_(θmax)/σ_c >> 0.4.In mining,similar 'stress/strength' ratios are used to suggest depth of break-out.The reality behind the fracture initiation stress/strength ratio of '0.4' is actually because of combinations of familiar tensile and compressive strength ratios(such as 10) with Poisson's ratio(say0.25).We exceed the extensional strain limits and start to see acoustic emission(AE) when tangential stress σθ ≈ 0.4σc,due to simple arithmetic.The combination of 2D theoretical FRACOD models and actual tunnelling suggests frequent initiation of failure by 'stable' extensional strain fracturing,but propagation in 'unstable' and therefore dynamic shearing.In the case of very deep tunnels(and 3D physical simulations),compressive stresses may be too high for extensional strain fracturing,and shearing will dominate,both ahead of the face and following the face.When shallower,the concept of 'extensional strain initiation but propagation' in shear is suggested.The various failure modes are richly illustrated,and the inability of conventional continuum modelling is emphasized,unless cohesion weakening and friction mobilization at different strain levels are used to reach a pseudo state of yield,but still considering a continuum.
文摘The magnetohydrodynamics laws govern the motion of a conducting fluid, such as blood, in an externally applied static magnetic field B0. When an artery is exposed to a magnetic field, the blood charged particles are deviated by the Lorentz force thus inducing electrical currents and voltages along the vessel walls and in the neighboring tissues. Such a situation may occur in several biomedical applications: magnetic resonance imaging (MRI), magnetic drug transport and targeting, tissue engineering… In this paper, we consider the steady unidirectional blood flow in a straight circular rigid vessel with non-conducting walls, in the presence of an exterior static magnetic field. The exact solution of Gold (1962) (with the induced fields not neglected) is revisited. It is shown that the integration over a cross section of the vessel of the longitudinal projection of the Lorentz force is zero, and that this result is related to the existence of current return paths, whose contributions compensate each other over the section. It is also demonstrated that the classical definition of the shear stresses cannot apply in this situation of magnetohydrodynamic flow, because, due to the existence of the Lorentz force, the axisymmetry is broken.
基金National Natural Science Foundation of China under Grant No.51148009National Natural Science Foundation of China under Grant No.50978005Project High-level Personnel in Beijing under Grant No.PHR20100502
文摘A composite shear wall concept based on concrete filled steel tube (CFST) columns and steel plate (SP) deep beams is proposed and examined in this study. The new wall is composed of three different energy dissipation elements: CFST columns; SP deep beams; and reinforced concrete (RC) strips. The RC strips are intended to allow the core structural elements - the CFST columns and SP deep beams - to work as a single structure to consume energy. Six specimens of different configurations were tested under cyclic loading. The resulting data are analyzed herein. In addition, numerical simulations of the stress and damage processes for each specimen were carried out, and simulations were completed for a range of location and span-height ratio variations for the SP beams. The simulations show good agreement with the test results. The core structure exhibits a ductile yielding mechanism characteristic of strong column-weak beam structures, hysteretic curves are plump and the composite shear wall exhibits several seismic defense lines. The deformation of the shear wall specimens with encased CFST column and SP deep beam design appears to be closer to that of entire shear walls. Establishing optimal design parameters for the configuration of SP deep beams is pivotal to the best seismic behavior of the wall. The new composite shear wall is therefore suitable for use in the seismic design of building structures.
基金Project(51178333)supported by the National Natural Science Foundation of ChinaProject(SLDRCE09-D-03)supported by the Ministry of Science and Technology of China
文摘A method is developed to predict the lateral load-carrying capacity of composite shear walls with double steel plates and filled concrete with binding bars(SCBs). Nonlinear finite element models of SCBs were established by using the finite element tool, Abaqus. Tie constraints were used to connect the binding bars and the steel plates. Surface-to-surface contact provided by the Abaqus was used to simulate the interaction between the steel plate and the core concrete. The established models could predict the lateral load-carrying capacity of SCBs with a reasonable degree of accuracy. A calculation method was developed by superposition principle to predict the lateral load-carrying capacity of SCBs for the engineering application. The concrete confined by steel plates and binding bars is under multi-axial compression; therefore, its shear strength was calculated by using the Guo-Wang concrete failure criterion. The shear strength of the steel plates of SCBs was calculated by using the von Mises yielding criterion without considering buckling. Results of the developed method are in good agreement with the testing and finite element results.
基金Project(51078077)supported by the National Natural Science Foundation of China
文摘To study the seismic performance and load-transferring mechanism of an innovative precast shear wall(IPSW) involving vertical joints, an experimental investigation and theoretical analysis were successively conducted on two test walls. The test results confirm the feasibility of the novel joints as well as the favorable seismic performance of the walls, even though certain optimization measures should be taken to improve the ductility. The load-transferring mechanism subsequently is theoretically investigated based on the experimental study. The theoretical results show the load-transferring route of the novel joints is concise and definite. During the elastic stage, the vertical shear stress in the connecting steel frame(CSF) distributes uniformly; and each high-strength bolt(HSB)primarily delivers vertical shear force. However, the stress in the CSF redistributes when the walls develop into the elastic-plastic stage. At the ultimate state, the vertical shear stress and horizontal normal stress in the CSF distribute linearly; and the HSBs at both ends of the CSF transfer the maximum shear forces.
文摘The alternative types of composite structure made of wood and cement based building materials needs to meet with the high demand for earthquake-resistant houses in Indonesia. In order to understand the mechanism of earthquake resisting performance of shear wall, it is necessary to investigate not only elastic behavior of shear walls but also non-linear one. In this study, series of full-scale experiments on timber frame shear walls composed of Akasia wood (Acacia mangium) sheathed by Fiber Cement Board (FCB) were carried out. For predicting skeleton curve, a series of theoretical equations was derived, which cannot only solve arbitrary nail pattern shear wall but also nonlinear behavior after yielding. Further, for describing hysteresis loops of shear walls, so-called Normalized Cyclic Loop (NCL) model was adopted. By combining two theoretical approaches, weintended to predict whole cyclic shear wall behaviors tested. Good agreements were obtained from comparison between experiment and prediction. The information obtain by this study will be useful for practical engineers or structural designers to design the high performance earthquake resisting timber houses.
文摘A new type of ductile lowrise shearwall with many short horizontalkeyways is proposed in this paper in order to improve the earthquake resistant behav-ior of ordinary lowrise shearwall.The behavior of this wall is studied through low-frequency cyclic loading test.Based on the test results,the paper puts forward thedifferent restoring force models for different lowrise shearwalls,and a program fortheir nonlinear dynamic analysis is worked out.Thr(?)h directly inputting earth-quake waves,the paper analyses the dynamic response and energy dissipation of 3types of lowrise shearwalls.The calculation results dem(?)strate that the newly de-vised ductile shearwall has good earthquake resistant behavior.
文摘To investigate the feasibility and seismic performance of the horizontal joints in an innovative precast shear wall system, two test walls were fabricated, and the monotonic and cyclic loading tests were performed on the two test walls, respectively. Then, the lateral load-top displacement curves, load beating capacity, ductility, lateral stiffness, strains of steel bars, strain distribution on the connecting steel frame (CSF), and relative slippages between the CSF and embedded limbic steel frame (ELSF) were discussed in detail. The test results show that the load bearing capacity and ductility of the test wall are both favorable with a displacement ductility factor of more than 3.7. The normal and shear stresses in the CSF except for the compression end are far smaller than the yield stresses throughout the test procedure. Certain slippages of about 1.13 mm occurs between the CSF and ELSF on the compression side of the test wall, while almost no slippages occurs on the tension side. The seismic performance of the test wall is favorable and the new-type scheme of the horizontal joints is both feasible and reliable.
基金The Basic Scientific Research Funds of Hohai University (No. B1020133)
文摘For a deeper understanding of the shear resistance performance of the steel-concrete-steel composite shear wall, the main influence factors such as the thicknesses of the steel plates and the concrete, the strength grades of the concrete and the span-depth ratios of the composite wall, which have impacts on the shear resistance performance of the composite shear wail, are analyzed by the numerical simulation method. Meanwhile, the simplified calculation formulae of the initial elastic lateral-resisting stiffness and the shear bearing capacity of the composite shear wall are also proposed. The research shows that with the increase in the thicknesses of the steel plates and the concrete and the increase in the strength grades of the concrete, the shear performance of the shear wall improves obviously; the span-depth ratios of the composite wall have a significant effect on the initial elastic lateral- resisting stiffness, but a small effect on the shear bearing capacity. Comparing the results of the simplified calculation formulae with those of the nonlinear finite element method, it is obvious that the presented formulae are reasonable and meet the real force state of the structure. These conclusions can serve as a preliminary design reference for the steel-concrete- steel composite shear wall.
文摘The shear wall with and without openings that served as a structural element or/and partition wall was utilized in a low-cost housing for the low-income people in Indonesia. The houses,however,should be withstoodfrom earthquake inertial force, so there must be no casualties when disaster struck. The alternative types of composite structure made of wood and cement based building materials needed to meet with the high demand for earthquake-resistant houses in Indonesia. In order to understand the mechanism of earthquake resisting performance of shear wall, we needs to investigate behavior of shear wallsnot only for cyclic static but alsofor dynamic loading. In this study, theseries of full-scale experiment on timber frame shear walls with and without openings,compose of Laminated Veneer Lumber (LVL) engineered wood (Paraserianthes Falcatariaand Hevea Brasiliensis) and sheathed by Fiber Cement Board (FCB), was carried out.By analyzing testing result using theoretical approaches, we intended to predict static initial stiffness and yielding strength as well as basic dynamic properties shear walls. For static behavior, good agreements were obtain from comparison between experiment and theoretical prediction based on mechanical model. While, for dynamic behavior, agreement was not sufficient due tothe effect of bending and rocking of actual test specimens. The information obtain by this study will be useful for practical engineers or structural designers to design the high performance earthquake resisting timber houses with a low construction cost.
文摘The work presents the results of tests on the shear parameters of walls made of AAC (autoclaved aerated concrete, fb = 4.0 N/mm2) on the system mortar for thin M5 and M10 joints (fm = 6.1 N/mm2 and fro = 11.9 N/mm2) and on polyurethane glue and also walls without mortar (dry masonry). The wall compression strength (on mortar M5 class) (per EN 1052-1:2000) amounted tofc,mv= 2.97 N/mm2 (fk = 2.48 N/mm2), elastic modulus was Ecru = 2,040 N/mm2. Various structure of bed joints and head joints were applied and the following were used as reinforcement: steel trusses of EFZ 140/Z 140 type (Z1 type) and meshes made of plastics (Z2 type). Based on the tests carried out with regard to unreinforced elements, it was shown that the filling in of head joints with mortar had an advantageous effect on the values of cracking and destruction stresses. While, with the use of reinforcement, advantageous increase of stress was obtained only when the mortar was laid twice on both bed surfaces of masonry units. The application of reinforcement in the bed joints when the mortar was laid only on one bed joints surface of the masonry units reduced the values of cracking and destruction stresses in relation to the values obtained in the unreinforced walls.
文摘The equations of the lateral deflection curve of the short pier shear wall under a lateral concentrated load at any level are derived by employing a continuous approach. Lateral flexibility matrixes for the dynamic analysis are also obtained by repeatedly calculating the lateral unit load on the wall at each level where a lumped mass located. Dynamic analyses are implemented for short pier shear walls with different parameters, called the integrative coefficient and the pier strength coefficient related to the dimensions of walls. The influences of two coefficients on the dynamic performances of the structure are studied. Results indicate that with the increase of the integrative coefficient, the periods of top two modes apparently decrease but the other periods of higher frequency modes show little variation when the pier strength coefficient remains constant. Similarly, if the integrative coefficient is constant, the top two periods of the free vibration decrease with the increase of the integrative coefficient but the other periods of higher frequency modes show less variation.
文摘Inthis paper, each of the two phases in dense two-phase flow is considered as continuous medium and the fundamental equations for two-phase flow arc described in Eulerian form. The generalized constitutive relation of the Bingham fluid is applied to the dispersed phase with the analysis oj physical mechanism of dense two-phase flow. The shearing stress of dispersed phase at a wall is used to give a boundary condition. Then a mathematical model for dense two-phase flow is obtained. In addition, the expressions of shearing stress of dispersed phase at a wall is derived according to the fundamental model of the friclional collision between dispersed-plutse particles and the wall.