AIM:To compare the corneal biomechanical properties difference by ocular response analyzer(ORA) in normal tension glaucoma(NTG) patients with different visual field(VF) progression speed. METHODS:NTG patients ...AIM:To compare the corneal biomechanical properties difference by ocular response analyzer(ORA) in normal tension glaucoma(NTG) patients with different visual field(VF) progression speed. METHODS:NTG patients with well-controlled Goldmann applanation tonometer(GAT) who routinely consulted Kitasato University Hospital Glaucoma Department between January 2010 and February 2014 were enrolled.GAT and ORA parameters including corneal compensated intraocular pressure(lOPcc),Goldmann estimated intraocular pressure(lOPg),corneal hysteresis(CH),corneal resistance factor(CRF) were recorded.VF was tested by Swedish interactive threshold algorithm(SITA)-standard 30-2 fields.All patients underwent VF measurement regularly and GAT did not exceed 15 mm Hg at any time during the 3y follow up.Patients were divided into four groups according to VF change over 3y,and ORA findings were compared between the upper 25th percentile group(slow progression group) and the lower 25th percentile group(rapid progression group).RESULTS:Eighty-two eyes of 56 patients were studied.There were 21 eyes(21 patients) each in rapid and slow progression groups respectively.GAT,lOPcc,lOPg,CH,CRF were 12.1+1.4 mm Hg,15.8±1.8 mm Hg,12.8±2.0 mm Hg,8.4±1.1 mm Hg,7.9±1.3 mm Hg respectively in rapid progression group and 11.5±1.3 mm Hg,13.5±2.1 mm Hg,11.2±1.6 mm Hg,9.3±1.1 mm Hg,8.2±0.9 mm Hg respectively in slow progression group(P=0.214,〈0.001,0.007,0.017,0.413,respectively).In bivariate correlation analysis,lOPcc,lOPcc-GAT and CH were significant correlated with m△MD(r =-0.292,-0.312,0.228 respectively,P =0.008,0.004,0.039 respectively).CONCLUSION:Relatively rapid VF progression occurred in NTG patients whose lOPcc are rather high,CH are rather low and the difference between lOPcc and GAT are relatively large.Higher lOPcc and lower CH are associated with VF progression in NTG patients.This study suggests that GAT measures might underestimate the IOP in such patients.展开更多
By performing density functional theory plus U calculations, we systematically study the structural, electronic, and magnetic properties of U02 under uniaxial tensile strain. The results show that the ideal tensile st...By performing density functional theory plus U calculations, we systematically study the structural, electronic, and magnetic properties of U02 under uniaxial tensile strain. The results show that the ideal tensile strengths along the [100], [110], and [111] directions are 93.6, 2Z7, and 16.4 GPa at strains of 0.44, 0.24, and 0.16, respectively. After electronic-structure investigation for tensile stain along the [001] direction, we find that the strong mixed ionic/covalent character of U-O bond is weakened by the tensile strain and there will occur an insulator to metal transition at strain over 0.30.展开更多
The surface of welded joints in X70 steel pipeline was processed by laser shock wave, its mechanical behaviors of tension fracture were analyzed with tension test,and the fracture morphologies and the distributions of...The surface of welded joints in X70 steel pipeline was processed by laser shock wave, its mechanical behaviors of tension fracture were analyzed with tension test,and the fracture morphologies and the distributions of chemical element were observed with scanning electron microscope and energy dispersive spectrum,respectively.The experimental results show that the phenomenon of grain refinement occurs in the surface of welded joints in X70 steel pipeline after the laser shock processing,and compressive residual stress is formed in its surface strengthened layer.There is no yield stage but a continuous yield behavior in the welded joints in X70 steel pipeline after the laser shock processing,and its extensibility has decreased by 20%.The welded joints in X70 steel pipeline in primitive state exhibits brittle fracture with less tearing edges,while the fracture of welded joints in X70 steel pipeline processed by laser shock is ductile fracture with a lot of tearing edges.展开更多
The microstructure of alloy Ti 3Al 10Nb 3V 1Mo after heated at 1170℃ for 1 h and cooled to room temperature at different rates was investigated by TEM. The result showed that W.Q. microstructure consisted of sing...The microstructure of alloy Ti 3Al 10Nb 3V 1Mo after heated at 1170℃ for 1 h and cooled to room temperature at different rates was investigated by TEM. The result showed that W.Q. microstructure consisted of single B2 phase, A.C. microstructure consisted of B2 phase matrix and second phase in some regions of the B2 phase crystal grains, and C.C. and F.C. microstructure appeared as a Widmannstatten structure consisting of coarse α 2 phase plates and β phase stripes between the plates. With the decreasing of colling rate, the tension strength was obviously decreased and the plasticity was slightly increased at room temperature.展开更多
文摘AIM:To compare the corneal biomechanical properties difference by ocular response analyzer(ORA) in normal tension glaucoma(NTG) patients with different visual field(VF) progression speed. METHODS:NTG patients with well-controlled Goldmann applanation tonometer(GAT) who routinely consulted Kitasato University Hospital Glaucoma Department between January 2010 and February 2014 were enrolled.GAT and ORA parameters including corneal compensated intraocular pressure(lOPcc),Goldmann estimated intraocular pressure(lOPg),corneal hysteresis(CH),corneal resistance factor(CRF) were recorded.VF was tested by Swedish interactive threshold algorithm(SITA)-standard 30-2 fields.All patients underwent VF measurement regularly and GAT did not exceed 15 mm Hg at any time during the 3y follow up.Patients were divided into four groups according to VF change over 3y,and ORA findings were compared between the upper 25th percentile group(slow progression group) and the lower 25th percentile group(rapid progression group).RESULTS:Eighty-two eyes of 56 patients were studied.There were 21 eyes(21 patients) each in rapid and slow progression groups respectively.GAT,lOPcc,lOPg,CH,CRF were 12.1+1.4 mm Hg,15.8±1.8 mm Hg,12.8±2.0 mm Hg,8.4±1.1 mm Hg,7.9±1.3 mm Hg respectively in rapid progression group and 11.5±1.3 mm Hg,13.5±2.1 mm Hg,11.2±1.6 mm Hg,9.3±1.1 mm Hg,8.2±0.9 mm Hg respectively in slow progression group(P=0.214,〈0.001,0.007,0.017,0.413,respectively).In bivariate correlation analysis,lOPcc,lOPcc-GAT and CH were significant correlated with m△MD(r =-0.292,-0.312,0.228 respectively,P =0.008,0.004,0.039 respectively).CONCLUSION:Relatively rapid VF progression occurred in NTG patients whose lOPcc are rather high,CH are rather low and the difference between lOPcc and GAT are relatively large.Higher lOPcc and lower CH are associated with VF progression in NTG patients.This study suggests that GAT measures might underestimate the IOP in such patients.
基金Supported by the National Natural Science Foundation of China under Grant Nos 11104170 and 51071032
文摘By performing density functional theory plus U calculations, we systematically study the structural, electronic, and magnetic properties of U02 under uniaxial tensile strain. The results show that the ideal tensile strengths along the [100], [110], and [111] directions are 93.6, 2Z7, and 16.4 GPa at strains of 0.44, 0.24, and 0.16, respectively. After electronic-structure investigation for tensile stain along the [001] direction, we find that the strong mixed ionic/covalent character of U-O bond is weakened by the tensile strain and there will occur an insulator to metal transition at strain over 0.30.
基金supported by the Natural Science Foundation of Jiangsu Province of China(BK2009104)
文摘The surface of welded joints in X70 steel pipeline was processed by laser shock wave, its mechanical behaviors of tension fracture were analyzed with tension test,and the fracture morphologies and the distributions of chemical element were observed with scanning electron microscope and energy dispersive spectrum,respectively.The experimental results show that the phenomenon of grain refinement occurs in the surface of welded joints in X70 steel pipeline after the laser shock processing,and compressive residual stress is formed in its surface strengthened layer.There is no yield stage but a continuous yield behavior in the welded joints in X70 steel pipeline after the laser shock processing,and its extensibility has decreased by 20%.The welded joints in X70 steel pipeline in primitive state exhibits brittle fracture with less tearing edges,while the fracture of welded joints in X70 steel pipeline processed by laser shock is ductile fracture with a lot of tearing edges.
文摘The microstructure of alloy Ti 3Al 10Nb 3V 1Mo after heated at 1170℃ for 1 h and cooled to room temperature at different rates was investigated by TEM. The result showed that W.Q. microstructure consisted of single B2 phase, A.C. microstructure consisted of B2 phase matrix and second phase in some regions of the B2 phase crystal grains, and C.C. and F.C. microstructure appeared as a Widmannstatten structure consisting of coarse α 2 phase plates and β phase stripes between the plates. With the decreasing of colling rate, the tension strength was obviously decreased and the plasticity was slightly increased at room temperature.