There are a few standards reported in the literature for testing and evaluation of thermal performance of solar concentrators based on sensible heating of working fluid. The preceding standard measures only the cookin...There are a few standards reported in the literature for testing and evaluation of thermal performance of solar concentrators based on sensible heating of working fluid. The preceding standard measures only the cooking efficiency and cooking capacity. Apart from thermal efficiency, there is an imperative need for other important parameters of the solar concentrators such as its stagnation temperature, cooking capacity, cost per watts delivered, weight of the cooker, ease of handling and aesthetics. The characterization of a concentrator at its operating temperature settles appropriate size and type of concentrator for any thermal application. The performance test is conducted at Chandwad (20.3292°N, 74.2444°E), Maharashtra and the proposed protocol aims for evaluation of thermal performance of solar cooking system and standardization of reporting the test results so that anyone can easily recognize and use it.展开更多
In Brazil and various regions globally, the initiation of landslides is frequently associated with rainfall;yet the spatial arrangement of geological structures and stratification considerably influences landslide occ...In Brazil and various regions globally, the initiation of landslides is frequently associated with rainfall;yet the spatial arrangement of geological structures and stratification considerably influences landslide occurrences. The multifaceted nature of these influences makes the surveillance of mass movements a highly intricate task, requiring an understanding of numerous interdependent variables. Recent years have seen an emergence in scholarly research aimed at integrating geophysical and geotechnical methodologies. The conjoint examination of geophysical and geotechnical data offers an enhanced perspective into subsurface structures. Within this work, a methodology is proposed for the synchronous analysis of electrical resistivity geophysical data and geotechnical data, specifically those extracted from the Light Dynamic Penetrometer (DPL) and Standard Penetration Test (SPT). This study involved a linear fitting process to correlate resistivity with N10/SPT N-values from DPL/SPT soundings, culminating in a 2D profile of N10/SPT N-values predicated on electrical profiles. The findings of this research furnish invaluable insights into slope stability by allowing for a two-dimensional representation of penetration resistance properties. Through the synthesis of geophysical and geotechnical data, this project aims to augment the comprehension of subsurface conditions, with potential implications for refining landslide risk evaluations. This endeavor offers insight into the formulation of more effective and precise slope management protocols and disaster prevention strategies.展开更多
The World Health Organization (WHO) standard assay for determining antibody level is the rapid fluorescent focus inhibition test (RFFIT) and is used to determine the degree of immunity after vaccination against rabies...The World Health Organization (WHO) standard assay for determining antibody level is the rapid fluorescent focus inhibition test (RFFIT) and is used to determine the degree of immunity after vaccination against rabies. To compare the difference in RFFIT results between the laboratories of The National Institute of Infectious Disease in Japan (NIID) and the Chinese Centre for Disease Control (CCDC) as well the influence of the choice of standard serum (STD) for the detection, the two laboratories detection methods were simultaneously manipulated by RFFIT. The reference serums used in NIID and the WHO standard serum used in CCDC were compared in the same RFFIT detection to determine the titer of four sera samples C1, S1, S2 and S4 in parallel, and the titers of the detected sera samples were calculated using the standard formula for neutralizing antibody titer. No significant difference was found in RFFIT methods from the two laboratories and the RFFIT testing procedures of the two laboratories have good consistency. However, different titers were obtained with the tentative internal standard serum (TI-STD) produced by adjusting to 2.0 IU of WHO standard serum in NIID and the WHO STD. The titer determined with the TI-STD was higher than that determined with WHO STD, This difference appears to be significant and requires further investigation.展开更多
Soil liquefaction is one of the complex research topics in geotechnical engineering and engineering geology. Especially after the 1964 Niigata earthquake (Japan) induced many soil liquefaction incidents, a variety of ...Soil liquefaction is one of the complex research topics in geotechnical engineering and engineering geology. Especially after the 1964 Niigata earthquake (Japan) induced many soil liquefaction incidents, a variety of soil liquefaction studies were conducted and reported, including the liquefaction potential assessment methods utilizing the shear wave velocity (V<sub>s</sub>) or SPT-N profiles (SPT: standard penetration test). This study used the V<sub>s</sub> and SPT methods recommended by the National Center for Earthquake Engineering Research (NCEER) to examine which is more conservative according to the assessment results on 41 liquefiable soil layers at sites in two major cities in Taiwan. Statistical hypothesis testing was used to make the analysis more quantitative and objective. Based on three sets of hypothesis tests, it shows that the hypothesis—the SPT method is more conservative than the V<sub>s</sub> method—was not rejected on a 5% level of significance.展开更多
文摘There are a few standards reported in the literature for testing and evaluation of thermal performance of solar concentrators based on sensible heating of working fluid. The preceding standard measures only the cooking efficiency and cooking capacity. Apart from thermal efficiency, there is an imperative need for other important parameters of the solar concentrators such as its stagnation temperature, cooking capacity, cost per watts delivered, weight of the cooker, ease of handling and aesthetics. The characterization of a concentrator at its operating temperature settles appropriate size and type of concentrator for any thermal application. The performance test is conducted at Chandwad (20.3292°N, 74.2444°E), Maharashtra and the proposed protocol aims for evaluation of thermal performance of solar cooking system and standardization of reporting the test results so that anyone can easily recognize and use it.
文摘In Brazil and various regions globally, the initiation of landslides is frequently associated with rainfall;yet the spatial arrangement of geological structures and stratification considerably influences landslide occurrences. The multifaceted nature of these influences makes the surveillance of mass movements a highly intricate task, requiring an understanding of numerous interdependent variables. Recent years have seen an emergence in scholarly research aimed at integrating geophysical and geotechnical methodologies. The conjoint examination of geophysical and geotechnical data offers an enhanced perspective into subsurface structures. Within this work, a methodology is proposed for the synchronous analysis of electrical resistivity geophysical data and geotechnical data, specifically those extracted from the Light Dynamic Penetrometer (DPL) and Standard Penetration Test (SPT). This study involved a linear fitting process to correlate resistivity with N10/SPT N-values from DPL/SPT soundings, culminating in a 2D profile of N10/SPT N-values predicated on electrical profiles. The findings of this research furnish invaluable insights into slope stability by allowing for a two-dimensional representation of penetration resistance properties. Through the synthesis of geophysical and geotechnical data, this project aims to augment the comprehension of subsurface conditions, with potential implications for refining landslide risk evaluations. This endeavor offers insight into the formulation of more effective and precise slope management protocols and disaster prevention strategies.
基金Grant from National Institute of Infectious Diseases(NIID)National Department Public Benefit Research Foundation (201103032)
文摘The World Health Organization (WHO) standard assay for determining antibody level is the rapid fluorescent focus inhibition test (RFFIT) and is used to determine the degree of immunity after vaccination against rabies. To compare the difference in RFFIT results between the laboratories of The National Institute of Infectious Disease in Japan (NIID) and the Chinese Centre for Disease Control (CCDC) as well the influence of the choice of standard serum (STD) for the detection, the two laboratories detection methods were simultaneously manipulated by RFFIT. The reference serums used in NIID and the WHO standard serum used in CCDC were compared in the same RFFIT detection to determine the titer of four sera samples C1, S1, S2 and S4 in parallel, and the titers of the detected sera samples were calculated using the standard formula for neutralizing antibody titer. No significant difference was found in RFFIT methods from the two laboratories and the RFFIT testing procedures of the two laboratories have good consistency. However, different titers were obtained with the tentative internal standard serum (TI-STD) produced by adjusting to 2.0 IU of WHO standard serum in NIID and the WHO STD. The titer determined with the TI-STD was higher than that determined with WHO STD, This difference appears to be significant and requires further investigation.
文摘Soil liquefaction is one of the complex research topics in geotechnical engineering and engineering geology. Especially after the 1964 Niigata earthquake (Japan) induced many soil liquefaction incidents, a variety of soil liquefaction studies were conducted and reported, including the liquefaction potential assessment methods utilizing the shear wave velocity (V<sub>s</sub>) or SPT-N profiles (SPT: standard penetration test). This study used the V<sub>s</sub> and SPT methods recommended by the National Center for Earthquake Engineering Research (NCEER) to examine which is more conservative according to the assessment results on 41 liquefiable soil layers at sites in two major cities in Taiwan. Statistical hypothesis testing was used to make the analysis more quantitative and objective. Based on three sets of hypothesis tests, it shows that the hypothesis—the SPT method is more conservative than the V<sub>s</sub> method—was not rejected on a 5% level of significance.