BACKGROUND Application of indocyanine green(ICG)fluorescence has led to new developments in gastrointestinal surgery.However,little is known about the use of ICG for the diagnosis of postoperative gut leakage(GL).In a...BACKGROUND Application of indocyanine green(ICG)fluorescence has led to new developments in gastrointestinal surgery.However,little is known about the use of ICG for the diagnosis of postoperative gut leakage(GL).In addition,there is a lack of rapid and intuitive methods to definitively diagnose postoperative GL.AIM To investigate the effect of ICG in the diagnosis of anastomotic leakage in a surgical rat GL model and evaluate its diagnostic value in colorectal surgery patients.METHODS Sixteen rats were divided into two groups:GL group(n=8)and sham group(n=8).Approximately 0.5 mL of ICG(2.5 mg/mL)was intravenously injected postoperatively.The peritoneal fluid was collected for the fluorescence test at 24 and 48 h.Six patients with rectal cancer who had undergone laparoscopic rectal cancer resection plus enterostomies were injected with 10 mL of ICG(2.5 mg/mL)on postoperative day 1.Their ostomy fluids were collected 24 h after ICG injection to identify the possibility of the ICG excreting from the peripheral veins to the enterostomy stoma.Participants who had undergone colectomy or rectal cancer resection were enrolled in the diagnostic test.The peritoneal fluids from drainage were collected 24 h after ICG injection.The ICG fluorescence test was conducted using OptoMedic endoscopy along with a near-infrared fluorescent imaging system.RESULTS The peritoneal fluids from the GL group showed ICG-dependent green fluorescence in contrast to the sham group.Six samples of ostomy fluids showed green fluorescence,indicating the possibility of ICG excreting from the peripheral veins to the enterostomy stoma in patients.The peritoneal fluid ICG test exhibited a sensitivity of 100%and a specificity of 83.3%for the diagnosis of GL.The positive predictive value was 71.4%,while the negative predictive value was 100%.The likelihood ratios were 6.0 for a positive test result and 0 for a negative result.CONCLUSION The postoperative ICG test in a drainage tube is a valuable and simple technique for the diagnosis of GL.Hence,it should be employed in clinical settings in patients with suspected GL.展开更多
针对油浸式电力变压器瞬态温升计算效率过低的问题,该文提出本征正交分解-αATS(proper orthogonal decomposition-adaptive time stepping based onαfactor,POD-αATS)降阶自适应变步长瞬态计算方法。首先,推导变压器绕组瞬态温升计...针对油浸式电力变压器瞬态温升计算效率过低的问题,该文提出本征正交分解-αATS(proper orthogonal decomposition-adaptive time stepping based onαfactor,POD-αATS)降阶自适应变步长瞬态计算方法。首先,推导变压器绕组瞬态温升计算的有限元离散方程;其次,采用POD降阶算法改善传统瞬态计算中存在的条件数过大及方程阶数过高的问题;同时对于瞬态计算中的时间步长选择问题,提出适用于非线性问题的αATS变步长策略;然后,为验证方法的有效性,基于110 kV油浸式电力变压器绕组的基本结构建立二维八分区数值计算模型,同时将计算结果与基于110 kV绕组的温升实验结果进行对比。数值计算及实验结果表明,所提算法与全阶定步长算法在流场和温度场中的精度几乎相同,且流场计算效率提升约45倍,温度场计算效率提升约38倍,计算速度得到显著提高。这一点在温升实验中同样得到验证,说明该文所提算法的准确性、高效性及一定的工程实用性。展开更多
Confining stresses serve as a pivotal determinant in shaping the behavior of grouted rock bolts.Nonetheless,prior investigations have oversimplified the three-dimensional stress state,primarily assuming hydrostatic st...Confining stresses serve as a pivotal determinant in shaping the behavior of grouted rock bolts.Nonetheless,prior investigations have oversimplified the three-dimensional stress state,primarily assuming hydrostatic stress conditions.Under these conditions,it is assumed that the intermediate principal stress(σ_(2))equals the minimum principal stress(σ_(3)).This assumption overlooks the potential variations in magnitudes of in situ stress conditions along all three directions near an underground opening where a rock bolt is installed.In this study,a series of push tests was meticulously conducted under triaxial conditions.These tests involved applying non-uniform confining stresses(σ_(2)≠σ_(3))to cubic specimens,aiming to unveil the previously overlooked influence of intermediate principal stresses on the strength properties of rock bolts.The results show that as the confining stresses increase from zero to higher levels,the pre-failure behavior changes from linear to nonlinear forms,resulting in an increase in initial stiffness from 2.08 kN/mm to 32.51 kN/mm.The load-displacement curves further illuminate distinct post-failure behavior at elevated levels of confining stresses,characterized by enhanced stiffness.Notably,the peak load capacity ranged from 27.9 kN to 46.5 kN as confining stresses advanced from σ_(2)=σ_(3)=0 to σ_(2)=20 MPa and σ_(3)=10 MPa.Additionally,the outcomes highlight an influence of confining stress on the lateral deformation of samples.Lower levels of confinement prompt overall dilation in lateral deformation,while higher confinements maintain a state of shrinkage.Furthermore,diverse failure modes have been identified,intricately tied to the arrangement of confining stresses.Lower confinements tend to induce a splitting mode of failure,whereas higher loads bring about a shift towards a pure interfacial shear-off and shear-crushed failure mechanism.展开更多
In underground engineering with complex conditions,the bolt(cable)anchorage support system is in an environment where static and dynamic stresses coexist,under the action of geological conditions such as high stresses...In underground engineering with complex conditions,the bolt(cable)anchorage support system is in an environment where static and dynamic stresses coexist,under the action of geological conditions such as high stresses and strong disturbances and construction conditions such as the application of high prestress.It is essential to study the support components performance under dynamic-static coupling conditions.Based on this,a multi-functional anchorage support dynamic-static coupling performance test system(MAC system)is developed,which can achieve 7 types of testing functions,including single component performance,anchored net performance,anchored rock performance and so on.The bolt and cable mechanical tests are conducted by MAC system under different prestress levels.The results showed that compared to the non-prestress condition,the impact resistance performance of prestressed bolts(cables)is significantly reduced.In the prestress range of 50–160 k N,the maximum reduction rate of impact energy resisted by different types of bolts is 53.9%–61.5%compared to non-prestress condition.In the prestress range of 150–300 k N,the impact energy resisted by high-strength cable is reduced by76.8%–84.6%compared to non-prestress condition.The MAC system achieves dynamic-static coupling performance test,which provide an effective means for the design of anchorage support system.展开更多
Edge devices,due to their limited computational and storage resources,often require the use of compilers for program optimization.Therefore,ensuring the security and reliability of these compilers is of paramount impo...Edge devices,due to their limited computational and storage resources,often require the use of compilers for program optimization.Therefore,ensuring the security and reliability of these compilers is of paramount importance in the emerging field of edge AI.One widely used testing method for this purpose is fuzz testing,which detects bugs by inputting random test cases into the target program.However,this process consumes significant time and resources.To improve the efficiency of compiler fuzz testing,it is common practice to utilize test case prioritization techniques.Some researchers use machine learning to predict the code coverage of test cases,aiming to maximize the test capability for the target compiler by increasing the overall predicted coverage of the test cases.Nevertheless,these methods can only forecast the code coverage of the compiler at a specific optimization level,potentially missing many optimization-related bugs.In this paper,we introduce C-CORE(short for Clustering by Code Representation),the first framework to prioritize test cases according to their code representations,which are derived directly from the source codes.This approach avoids being limited to specific compiler states and extends to a broader range of compiler bugs.Specifically,we first train a scaled pre-trained programming language model to capture as many common features as possible from the test cases generated by a fuzzer.Using this pre-trained model,we then train two downstream models:one for predicting the likelihood of triggering a bug and another for identifying code representations associated with bugs.Subsequently,we cluster the test cases according to their code representations and select the highest-scoring test case from each cluster as the high-quality test case.This reduction in redundant testing cases leads to time savings.Comprehensive evaluation results reveal that code representations are better at distinguishing test capabilities,and C-CORE significantly enhances testing efficiency.Across four datasets,C-CORE increases the average of the percentage of faults detected(APFD)value by 0.16 to 0.31 and reduces test time by over 50% in 46% of cases.When compared to the best results from approaches using predicted code coverage,C-CORE improves the APFD value by 1.1% to 12.3% and achieves an overall time-saving of 159.1%.展开更多
Objective:Serological tests are widely used for scrub typhus diagnosis;however,their limitations are evident.This study aims to assess their practical value in clinical settings.Methods:We analyzed the data of adult p...Objective:Serological tests are widely used for scrub typhus diagnosis;however,their limitations are evident.This study aims to assess their practical value in clinical settings.Methods:We analyzed the data of adult patients with suspected scrub typhus who visited a tertiary care hospital in the Republic of Korea from September to December from 2019 to 2021.The included patients had an acute fever and at least one of the following ten secondary findings:myalgia,skin rash,eschar,headache,thrombocytopenia,increased liver enzyme levels,lymphadenopathy,hepatomegaly,splenomegaly,and pleural effusion.The diagnoses were grouped as scrub typhus or other diseases by two infectious disease physicians.Results:Among 136 patients who met the eligibility criteria,109 had scrub typhus and 27 had different diseases.Single and paired total antibodies using immunofluorescence assay(IFA),and total antibodies using immunochromatography-based rapid diagnostic testing(ICT)were measured in 98%,22%,and 75%of all patients,respectively.Confirmation using paired samples for scrub typhus was established at a median of 11[interquartile range(IQR)10-16]days following the first visit.Among the 82 admitted patients,the median admission time was 9(IQR 7-13)days.According to IFA,58(55%)patients with scrub typhus had total immunoglobulin titers≥1:320,while 23(85%)patients with other disease had titers<1:320.Positive ICT results were observed in 64(74%)patients with scrub typhus and 10(67%)patients with other diseases showed negative ICT results.Conclusions:Serological testing for scrub typhus is currently insufficient for decision-making in clinical practice.展开更多
In this editorial,we discuss the article in the World Journal of Gastroenterology.The article conducts a meta-analysis of the diagnostic accuracy of the urea breath test(UBT),a non-invasive method for detecting Helico...In this editorial,we discuss the article in the World Journal of Gastroenterology.The article conducts a meta-analysis of the diagnostic accuracy of the urea breath test(UBT),a non-invasive method for detecting Helicobacter pylori(H.pylori)infection in humans.It is based on radionuclide-labeled urea.Various methods,both invasive and non-invasive,are available for diagnosing H.pylori infection,inclu-ding endoscopy with biopsy,serology for immunoglobulin titers,stool antigen analysis,and UBT.Several guidelines recommend UBTs as the primary choice for diagnosing H.pylori infection and for reexamining after eradication therapy.It is used to be the first choice non-invasive test due to their high accuracy,specificity,rapid results,and simplicity.Moreover,its performance remains unaffected by the distribution of H.pylori in the stomach,allowing a high flow of patients to be tested.Despite its widespread use,the performance characteristics of UBT have been inconsistently described and remain incompletely defined.There are two UBTs available with Food and Drug Administration approval:The 13C and 14C tests.Both tests are affordable and can provide real-time results.Physicians may prefer the 13C test because it is non-radioactive,compared to 14C which uses a radioactive isotope,especially in young children and pregnant women.Although there was heterogeneity among the studies regarding the diagnostic accuracy of both UBTs,13C-UBT consistently outperforms the 14C-UBT.This makes the 13C-UBT the preferred diagnostic approach.Furthermore,the provided findings of the meta-analysis emphasize the significance of precise considerations when choosing urea dosage,assessment timing,and measurement techniques for both the 13C-UBT and 14C-UBT,to enhance diagnostic precision.展开更多
BACKGROUND Helicobacter pylori(H.pylori)infection has been well-established as a significant risk factor for several gastrointestinal disorders.The urea breath test(UBT)has emerged as a leading non-invasive method for...BACKGROUND Helicobacter pylori(H.pylori)infection has been well-established as a significant risk factor for several gastrointestinal disorders.The urea breath test(UBT)has emerged as a leading non-invasive method for detecting H.pylori.Despite numerous studies confirming its substantial accuracy,the reliability of UBT results is often compromised by inherent limitations.These findings underscore the need for a rigorous statistical synthesis to clarify and reconcile the diagnostic accuracy of the UBT for the diagnosis of H.pylori infection.AIM To determine and compare the diagnostic accuracy of 13C-UBT and 14C-UBT for H.pylori infection in adult patients with dyspepsia.METHODS We conducted an independent search of the PubMed/MEDLINE,EMBASE,and Cochrane Central databases until April 2022.Our search included diagnostic accuracy studies that evaluated at least one of the index tests(^(13)C-UBT or ^(14)C-UBT)against a reference standard.We used the QUADAS-2 tool to assess the methodo-logical quality of the studies.We utilized the bivariate random-effects model to calculate sensitivity,specificity,positive and negative test likelihood ratios(LR+and LR-),as well as the diagnostic odds ratio(DOR),and their 95%confidence intervals.We conducted subgroup analyses based on urea dosing,time after urea administration,and assessment technique.To investigate a possible threshold effect,we conducted Spearman correlation analysis,and we generated summary receiver operating characteristic(SROC)curves to assess heterogeneity.Finally,we visually inspected a funnel plot and used Egger’s test to evaluate publication bias.endorsing both as reliable diagnostic tools in clinical practice.CONCLUSION In summary,our study has demonstrated that ^(13)C-UBT has been found to outperform the ^(14)C-UBT,making it the preferred diagnostic approach.Additionally,our results emphasize the significance of carefully considering urea dosage,assessment timing,and measurement techniques for both tests to enhance diagnostic precision.Nevertheless,it is crucial for researchers and clinicians to evaluate the strengths and limitations of our findings before implementing them in practice.展开更多
Screening for maternal syphilis has been an essential component of routine antenatal screening tests in most countries for many years. This is not only because of the virulence of the spirochete which causes the infec...Screening for maternal syphilis has been an essential component of routine antenatal screening tests in most countries for many years. This is not only because of the virulence of the spirochete which causes the infection but also because of its vertical transmission rate and the potential severe adverse complications/morbidity that can result from its transmission to the fetus. Although the incidence of maternal syphilis and its fetal sequalae in low-income countries has been considerable for several years, the disease has been almost non-existent in high income countries with wide antenatal screening coverage and effective treatment programmes for Syphilis. The recent alarming increase in the incidence of maternal syphilis in high income countries has spawned a renewed public health interest in the infection, with several countries updating and strengthening public health guidance in an attempt to stem this dramatic trend. This is a short clinical update for the practising obstetrician on how to manage the antenatal patient with a positive syphilis screening test.展开更多
Intelligent penetration testing is of great significance for the improvement of the security of information systems,and the critical issue is the planning of penetration test paths.In view of the difficulty for attack...Intelligent penetration testing is of great significance for the improvement of the security of information systems,and the critical issue is the planning of penetration test paths.In view of the difficulty for attackers to obtain complete network information in realistic network scenarios,Reinforcement Learning(RL)is a promising solution to discover the optimal penetration path under incomplete information about the target network.Existing RL-based methods are challenged by the sizeable discrete action space,which leads to difficulties in the convergence.Moreover,most methods still rely on experts’knowledge.To address these issues,this paper proposes a penetration path planning method based on reinforcement learning with episodic memory.First,the penetration testing problem is formally described in terms of reinforcement learning.To speed up the training process without specific prior knowledge,the proposed algorithm introduces episodic memory to store experienced advantageous strategies for the first time.Furthermore,the method offers an exploration strategy based on episodic memory to guide the agents in learning.The design makes full use of historical experience to achieve the purpose of reducing blind exploration and improving planning efficiency.Ultimately,comparison experiments are carried out with the existing RL-based methods.The results reveal that the proposed method has better convergence performance.The running time is reduced by more than 20%.展开更多
Since the beginning of COVID-19 pandemics many countries were facing challenges with testing capacity recourse limitations. Throughout the waves of the pandemic countries were trying to address the existing constrains...Since the beginning of COVID-19 pandemics many countries were facing challenges with testing capacity recourse limitations. Throughout the waves of the pandemic countries were trying to address the existing constrains exploring solutions to increase the testing capacity with more cost-effective approaches. Pooled methodology was one of the methods which many have validated and used. It is evident that in case of pooled sample testing the sensitivity becomes lower, however the variation highly depends on the pool size as well as the incidence rate at the certain point. Armenia as well as many other countries has adopted regulations for mandatory COVID-19 PCR testing for all the travelers. Current study aimed to explore the efficiency of COVID-19 pooled PCR testing for nasopharyngeal swabs of individuals with no symptoms in a time period with good epidemiological state of the infection. Nasopharingeal swab samples from individuals were collected. The manual extraction of RNAs of samples was performed after pooling up to 5 samples. The pools with Cycle Threshold (CT) of < 37 were considered positive and were retested individually. In total 28,015 samples were grouped in 667 pools of which 57 were positive. The total number of positive samples was 65. The median difference (CT-pool–CT samples) was 2.4 (ranging from–3.0 to 8.9). The correlation of CT of pools and positive samples was positive. The correlation coefficient r = 0.84, P < 0.000, 95% CI range 0.7423 to 0.9243). The total economic saving when using pools compared to the individual testing was 72%. The minor difference between CT values of pools and samples can be explained by the dilution effect in the pool. However, the positive correlation between the values as well as the amount of cost saving demonstrate that pooling on nasopharyngeal samples for COVID-19 PCR testing can be a good method for efficient screening with significant resource saving. One of the most important advantages of the proposed method is the fact that samples are pooled prior extraction, which avoids the possibilities with misinterpretation of IC due to low yield of RNA in the extraction process.展开更多
Background and Objective: HIV, hepatitis B virus (HBV) and hepatitis C virus (HCV) are very widespread in the world, however, less than 20% of the people affected are diagnosed and treated. This study aimed to determi...Background and Objective: HIV, hepatitis B virus (HBV) and hepatitis C virus (HCV) are very widespread in the world, however, less than 20% of the people affected are diagnosed and treated. This study aimed to determine the prevalence of HIV, HCV and HBV co-infections in pregnant women at Bangui Community University Hospital and the cost of screening. Methods: A cross-sectional study involving consenting pregnant women who came for antenatal care was performed. HIV, HCV antibodies and HBV antigens were detected using Exacto Triplex<sup>?</sup> HIV/HCV/HBsAg rapid test, cross-validated by ELISA tests. Sociodemographic and professional data, the modes of transmission and prevention of HIV and both hepatitis viruses were collected in a standard sheet and analyzed using the Epi-Info software version 7. Results: Pregnant women aged 15 to 24 were the most affected (45.3%);high school girls (46.0%), and pregnant women living in cohabitation (65.3%) were the most represented. Twenty-five (16.7%) worked in the formal sector, 12.7% were unemployed housewives and the remainder in the informal sector. The prevalence of HIV, HBV, and HCV viruses was 11.8%, 21.9% and 22.2%, respectively. The prevalence of co-infections was 8.6% for HIV-HBV, 10.2% for HIV-HCV, 14.7% for HBV-HCV and 6.5% for HIV-HBV-HCV. All positive results and 10% of negative results by the rapid test were confirmed by ELISA tests. The serology of the three viruses costs 39,000 FCFA (60 Euros) by ELISA compared to 10,000 FCFA (15.00 Euros) with Exacto Triplex<sup>?</sup> HIV/HCV/AgHBs (BioSynex, Strasbourg, France). Conclusion: The low level of education and awareness of hepatitis are barriers to development and indicate the importance of improving the literacy rate of women in the Central African Republic (CAR). Likewise, the high prevalence of the three viruses shows the need for the urgent establishment of a national program to combat viral hepatitis in the CAR.展开更多
1) Background: Rapid and acurate diagnostic testing for case identification, quarantine, and contact tracing is essential for managing the COVID 19 pandemic. Rapid antigen detection tests are available, however, it is...1) Background: Rapid and acurate diagnostic testing for case identification, quarantine, and contact tracing is essential for managing the COVID 19 pandemic. Rapid antigen detection tests are available, however, it is important to evaluate their performances before use. We tested a rapid antigen detection of SARS-CoV-2, based on the immunochromatography (Boson Biotech SARS-CoV-2 Ag Test (Xiamen Boson Biotech Co., Ltd., China)) and the results were compared with the real time reverse transcriptase-Polymerase chain reaction (RT-PCR) (Gold standard) results;2) Methods: From November 2021 to December 2021, samples were collected from symptomatic patients and asymptomatic individuals referred for testing in a hospital during the second pandemic wave in Gabon. All these participants attending “CTA Angondjé”, a field hospital set up as part of the management of COVID-19 in Gabon. Two nasopharyngeal swabs were collected in all the patients, one for Ag test and the other for RT-PCR;3) Results: A total of 300 samples were collected from 189 symptomatic and 111 asymptomatic individuals. The sensitivity and specificity of the antigen test were 82.5% [95%CI 73.8 - 89.3] and 97.9 % [95%CI 92.2 - 98.2] respectively, and the diagnostic accuracy was 84.4% (95% CI: 79.8 - 88.3%). The antigen test was more likely to be positive for samples with RT-PCR Ct values ≤ 32, with a sensitivity of 89.8%;4) Conclusions: The Boson Biotech SARS-CoV-2 Ag Test has good sensitivity and can detect SARS-CoV-2 infection, especially among symptomatic individuals with low viral load. This test could be incorporated into efficient testing algorithms as an alternative to PCR to decrease diagnostic delays and curb viral transmission.展开更多
Rapid and timely testing is essential to minimize the COVID-19 spread. Decision makers and policy planners need to determine the equal distribution and accessibility of testing sites. This study mainly examines the sp...Rapid and timely testing is essential to minimize the COVID-19 spread. Decision makers and policy planners need to determine the equal distribution and accessibility of testing sites. This study mainly examines the spatial equality of COVID-19 testing sites that maintain a zero COVID policy in Guangzhou City. The study has identified the spatial disparities of COVID testing sites, characteristics of testing locations, and accessibility. The study has obtained information on COVID testing sites in Guangzhou City and population data. Point pattern analyses, Euclidian distance and allocation, and network analyses are the main methods used to achieve the research objectives, and 1183 total COVID testing sites can be recognized in Guangzhou City. Results revealed that spatial disparities could be noticed over the study area. Testing locations of Guangzhou City are highly clustered. The most significant testing sites are located in Haizhu District, which has the third largest population. The highest population density can be identified in Yuexiu District. However, only 94 testing sites are located there. According to all the results, higher disparities can be identified, and a lack of testing sites is located in the north part of the study area. Some people in the northern part have to travel more than 10 km to reach a testing site. Finally, this paper suggests increasing the number of testing sites in the north and south parts of the study area and keeping the same distribution, considering the area, total population, and population density. This kind of research will be helpful to decision-makers in making proper decisions to maintain a zero COVID policy.展开更多
Background: When continuous scale measurements are available, agreements between two measuring devices are assessed both graphically and analytically. In clinical investigations, Bland and Altman proposed plotting sub...Background: When continuous scale measurements are available, agreements between two measuring devices are assessed both graphically and analytically. In clinical investigations, Bland and Altman proposed plotting subject-wise differences between raters against subject-wise averages. In order to scientifically assess agreement, Bartko recommended combining the graphical approach with the statistical analytic procedure suggested by Bradley and Blackwood. The advantage of using this approach is that it enables significance testing and sample size estimation. We noted that the direct use of the results of the regression is misleading and we provide a correction in this regard. Methods: Graphical and linear models are used to assess agreements for continuous scale measurements. We demonstrate that software linear regression results should not be readily used and we provided correct analytic procedures. The degrees of freedom of the F-statistics are incorrectly reported, and we propose methods to overcome this problem by introducing the correct analytic form of the F statistic. Methods for sample size estimation using R-functions are also given. Results: We believe that the tutorial and the R-codes are useful tools for testing and estimating agreement between two rating protocols for continuous scale measurements. The interested reader may use the codes and apply them to their available data when the issue of agreement between two raters is the subject of interest.展开更多
Dear Editor,The tuberculin skin test(TST)reagents have continuously improved,with the ESAT6-CFP10(EC)test having recently been introduced,but are seldom based on the direction of the delayed-type hypersensitivity(DTH)...Dear Editor,The tuberculin skin test(TST)reagents have continuously improved,with the ESAT6-CFP10(EC)test having recently been introduced,but are seldom based on the direction of the delayed-type hypersensitivity(DTH)mechanism.Previous studies only partially showed the infiltration and activation of immune cells and the production of cytokines of the skin induration[1,2],and lack the detailed measurements of cell proportions and gene expression in the DTH response.Therefore,in this study,we revealed the comprehensive characteristics of DTH by single-cell RNA sequencing(scRNA-seq)in the guinea pig tuberculosis(TB)model[Experimental Animal Welfare Ethics Committee,Beijing Tuberculosis and Thoracic Tumor Research Institute(2021-064)].展开更多
Ultrasonic baths and sonochemical reactors are widely used in industrial applications dealing with surface cleaningand chemical synthesis. The processes of erosion, cleaning and structuring of the surface can be typic...Ultrasonic baths and sonochemical reactors are widely used in industrial applications dealing with surface cleaningand chemical synthesis. The processes of erosion, cleaning and structuring of the surface can be typically controlledby changing relevant influential parameters. In particular, in this work, we experimentally investigate theeffect of NaCl concentration (0–5.5 mol/L) on the erosion of an aluminum foil under ultrasonic exposure at afrequency of 28 kHz. Special attention is paid to the determination of cavitation zones and their visualizationusing heat maps. It is found that at low NaCl concentration (0.3 mol/L), the foil destruction rate is higher thanin distilled water. At higher concentrations of salt, cavitation takes place mainly in the upper part of the container.展开更多
AIM:To investigate the efficacy of a new visual acuity(VA)screening method,the baby vision test for young children.METHODS:A total 105 eyes of 65 children aged 2-8y were included in the study.Acuity testing was conduc...AIM:To investigate the efficacy of a new visual acuity(VA)screening method,the baby vision test for young children.METHODS:A total 105 eyes of 65 children aged 2-8y were included in the study.Acuity testing was conducted using a standardized recognition acuity chart(Snellen visual chart:at 3 m)and the baby vision model assessment.The baby vision device includes a screen,a near infrared camera and a computer.Children were seated at a measured distance of 33-40 cm from a display for testing.VA was estimated according to the highest resolution the children could follow.Decimal VA data were converted to logarithm of the minimum angle of resolution(logMAR)for statistical analysis.The VA results for each child were recorded and analyzed for consistency.RESULTS:The mean VA measured using the Snellen visual chart was 0.62±0.32,and that assessed using the baby vision test was 0.66±0.27.The 95%limit of agreement was-0.609 to 0.695,with 95.2%(100/105)plots within the 95%limits of agreement.VA values of the baby vision test were significantly correlated with those of the Snellen chart(R=0.274,P=0.005).CONCLUSION:The baby vision test can be used as a relatively reliable method for estimating VA in young children.This new acuity assessment might be a valid predictor of optotype-measured acuity later in preverbal children.展开更多
基金Supported by the Science and Technology Projects in Guangzhou,No.202201010623 and No.2024A03J1016Guangzhou Science and Technology Project of Traditional Chinese Medicine and Combined Chinese and Western Medicine,No.20242A011001Guangdong Medical Science and Research Foundation,No.A2024088.
文摘BACKGROUND Application of indocyanine green(ICG)fluorescence has led to new developments in gastrointestinal surgery.However,little is known about the use of ICG for the diagnosis of postoperative gut leakage(GL).In addition,there is a lack of rapid and intuitive methods to definitively diagnose postoperative GL.AIM To investigate the effect of ICG in the diagnosis of anastomotic leakage in a surgical rat GL model and evaluate its diagnostic value in colorectal surgery patients.METHODS Sixteen rats were divided into two groups:GL group(n=8)and sham group(n=8).Approximately 0.5 mL of ICG(2.5 mg/mL)was intravenously injected postoperatively.The peritoneal fluid was collected for the fluorescence test at 24 and 48 h.Six patients with rectal cancer who had undergone laparoscopic rectal cancer resection plus enterostomies were injected with 10 mL of ICG(2.5 mg/mL)on postoperative day 1.Their ostomy fluids were collected 24 h after ICG injection to identify the possibility of the ICG excreting from the peripheral veins to the enterostomy stoma.Participants who had undergone colectomy or rectal cancer resection were enrolled in the diagnostic test.The peritoneal fluids from drainage were collected 24 h after ICG injection.The ICG fluorescence test was conducted using OptoMedic endoscopy along with a near-infrared fluorescent imaging system.RESULTS The peritoneal fluids from the GL group showed ICG-dependent green fluorescence in contrast to the sham group.Six samples of ostomy fluids showed green fluorescence,indicating the possibility of ICG excreting from the peripheral veins to the enterostomy stoma in patients.The peritoneal fluid ICG test exhibited a sensitivity of 100%and a specificity of 83.3%for the diagnosis of GL.The positive predictive value was 71.4%,while the negative predictive value was 100%.The likelihood ratios were 6.0 for a positive test result and 0 for a negative result.CONCLUSION The postoperative ICG test in a drainage tube is a valuable and simple technique for the diagnosis of GL.Hence,it should be employed in clinical settings in patients with suspected GL.
文摘针对油浸式电力变压器瞬态温升计算效率过低的问题,该文提出本征正交分解-αATS(proper orthogonal decomposition-adaptive time stepping based onαfactor,POD-αATS)降阶自适应变步长瞬态计算方法。首先,推导变压器绕组瞬态温升计算的有限元离散方程;其次,采用POD降阶算法改善传统瞬态计算中存在的条件数过大及方程阶数过高的问题;同时对于瞬态计算中的时间步长选择问题,提出适用于非线性问题的αATS变步长策略;然后,为验证方法的有效性,基于110 kV油浸式电力变压器绕组的基本结构建立二维八分区数值计算模型,同时将计算结果与基于110 kV绕组的温升实验结果进行对比。数值计算及实验结果表明,所提算法与全阶定步长算法在流场和温度场中的精度几乎相同,且流场计算效率提升约45倍,温度场计算效率提升约38倍,计算速度得到显著提高。这一点在温升实验中同样得到验证,说明该文所提算法的准确性、高效性及一定的工程实用性。
文摘Confining stresses serve as a pivotal determinant in shaping the behavior of grouted rock bolts.Nonetheless,prior investigations have oversimplified the three-dimensional stress state,primarily assuming hydrostatic stress conditions.Under these conditions,it is assumed that the intermediate principal stress(σ_(2))equals the minimum principal stress(σ_(3)).This assumption overlooks the potential variations in magnitudes of in situ stress conditions along all three directions near an underground opening where a rock bolt is installed.In this study,a series of push tests was meticulously conducted under triaxial conditions.These tests involved applying non-uniform confining stresses(σ_(2)≠σ_(3))to cubic specimens,aiming to unveil the previously overlooked influence of intermediate principal stresses on the strength properties of rock bolts.The results show that as the confining stresses increase from zero to higher levels,the pre-failure behavior changes from linear to nonlinear forms,resulting in an increase in initial stiffness from 2.08 kN/mm to 32.51 kN/mm.The load-displacement curves further illuminate distinct post-failure behavior at elevated levels of confining stresses,characterized by enhanced stiffness.Notably,the peak load capacity ranged from 27.9 kN to 46.5 kN as confining stresses advanced from σ_(2)=σ_(3)=0 to σ_(2)=20 MPa and σ_(3)=10 MPa.Additionally,the outcomes highlight an influence of confining stress on the lateral deformation of samples.Lower levels of confinement prompt overall dilation in lateral deformation,while higher confinements maintain a state of shrinkage.Furthermore,diverse failure modes have been identified,intricately tied to the arrangement of confining stresses.Lower confinements tend to induce a splitting mode of failure,whereas higher loads bring about a shift towards a pure interfacial shear-off and shear-crushed failure mechanism.
基金supported by the National Natural Science Foundation of China(Nos.51927807,52074164,42277174,42077267 and 42177130)the Natural Science Foundation of Shandong Province,China(No.ZR2020JQ23)China University of Mining and Technology(Beijing)Top Innovative Talent Cultivation Fund for Doctoral Students(No.BBJ2023048)。
文摘In underground engineering with complex conditions,the bolt(cable)anchorage support system is in an environment where static and dynamic stresses coexist,under the action of geological conditions such as high stresses and strong disturbances and construction conditions such as the application of high prestress.It is essential to study the support components performance under dynamic-static coupling conditions.Based on this,a multi-functional anchorage support dynamic-static coupling performance test system(MAC system)is developed,which can achieve 7 types of testing functions,including single component performance,anchored net performance,anchored rock performance and so on.The bolt and cable mechanical tests are conducted by MAC system under different prestress levels.The results showed that compared to the non-prestress condition,the impact resistance performance of prestressed bolts(cables)is significantly reduced.In the prestress range of 50–160 k N,the maximum reduction rate of impact energy resisted by different types of bolts is 53.9%–61.5%compared to non-prestress condition.In the prestress range of 150–300 k N,the impact energy resisted by high-strength cable is reduced by76.8%–84.6%compared to non-prestress condition.The MAC system achieves dynamic-static coupling performance test,which provide an effective means for the design of anchorage support system.
文摘Edge devices,due to their limited computational and storage resources,often require the use of compilers for program optimization.Therefore,ensuring the security and reliability of these compilers is of paramount importance in the emerging field of edge AI.One widely used testing method for this purpose is fuzz testing,which detects bugs by inputting random test cases into the target program.However,this process consumes significant time and resources.To improve the efficiency of compiler fuzz testing,it is common practice to utilize test case prioritization techniques.Some researchers use machine learning to predict the code coverage of test cases,aiming to maximize the test capability for the target compiler by increasing the overall predicted coverage of the test cases.Nevertheless,these methods can only forecast the code coverage of the compiler at a specific optimization level,potentially missing many optimization-related bugs.In this paper,we introduce C-CORE(short for Clustering by Code Representation),the first framework to prioritize test cases according to their code representations,which are derived directly from the source codes.This approach avoids being limited to specific compiler states and extends to a broader range of compiler bugs.Specifically,we first train a scaled pre-trained programming language model to capture as many common features as possible from the test cases generated by a fuzzer.Using this pre-trained model,we then train two downstream models:one for predicting the likelihood of triggering a bug and another for identifying code representations associated with bugs.Subsequently,we cluster the test cases according to their code representations and select the highest-scoring test case from each cluster as the high-quality test case.This reduction in redundant testing cases leads to time savings.Comprehensive evaluation results reveal that code representations are better at distinguishing test capabilities,and C-CORE significantly enhances testing efficiency.Across four datasets,C-CORE increases the average of the percentage of faults detected(APFD)value by 0.16 to 0.31 and reduces test time by over 50% in 46% of cases.When compared to the best results from approaches using predicted code coverage,C-CORE improves the APFD value by 1.1% to 12.3% and achieves an overall time-saving of 159.1%.
基金the Korea Health Technology R&D Project through the Korea Health Industry Development Institute(KHIDI),funded by the Ministry of Health&Welfare,Republic of Korea(grant no.HI22C0306).
文摘Objective:Serological tests are widely used for scrub typhus diagnosis;however,their limitations are evident.This study aims to assess their practical value in clinical settings.Methods:We analyzed the data of adult patients with suspected scrub typhus who visited a tertiary care hospital in the Republic of Korea from September to December from 2019 to 2021.The included patients had an acute fever and at least one of the following ten secondary findings:myalgia,skin rash,eschar,headache,thrombocytopenia,increased liver enzyme levels,lymphadenopathy,hepatomegaly,splenomegaly,and pleural effusion.The diagnoses were grouped as scrub typhus or other diseases by two infectious disease physicians.Results:Among 136 patients who met the eligibility criteria,109 had scrub typhus and 27 had different diseases.Single and paired total antibodies using immunofluorescence assay(IFA),and total antibodies using immunochromatography-based rapid diagnostic testing(ICT)were measured in 98%,22%,and 75%of all patients,respectively.Confirmation using paired samples for scrub typhus was established at a median of 11[interquartile range(IQR)10-16]days following the first visit.Among the 82 admitted patients,the median admission time was 9(IQR 7-13)days.According to IFA,58(55%)patients with scrub typhus had total immunoglobulin titers≥1:320,while 23(85%)patients with other disease had titers<1:320.Positive ICT results were observed in 64(74%)patients with scrub typhus and 10(67%)patients with other diseases showed negative ICT results.Conclusions:Serological testing for scrub typhus is currently insufficient for decision-making in clinical practice.
文摘In this editorial,we discuss the article in the World Journal of Gastroenterology.The article conducts a meta-analysis of the diagnostic accuracy of the urea breath test(UBT),a non-invasive method for detecting Helicobacter pylori(H.pylori)infection in humans.It is based on radionuclide-labeled urea.Various methods,both invasive and non-invasive,are available for diagnosing H.pylori infection,inclu-ding endoscopy with biopsy,serology for immunoglobulin titers,stool antigen analysis,and UBT.Several guidelines recommend UBTs as the primary choice for diagnosing H.pylori infection and for reexamining after eradication therapy.It is used to be the first choice non-invasive test due to their high accuracy,specificity,rapid results,and simplicity.Moreover,its performance remains unaffected by the distribution of H.pylori in the stomach,allowing a high flow of patients to be tested.Despite its widespread use,the performance characteristics of UBT have been inconsistently described and remain incompletely defined.There are two UBTs available with Food and Drug Administration approval:The 13C and 14C tests.Both tests are affordable and can provide real-time results.Physicians may prefer the 13C test because it is non-radioactive,compared to 14C which uses a radioactive isotope,especially in young children and pregnant women.Although there was heterogeneity among the studies regarding the diagnostic accuracy of both UBTs,13C-UBT consistently outperforms the 14C-UBT.This makes the 13C-UBT the preferred diagnostic approach.Furthermore,the provided findings of the meta-analysis emphasize the significance of precise considerations when choosing urea dosage,assessment timing,and measurement techniques for both the 13C-UBT and 14C-UBT,to enhance diagnostic precision.
基金Supported by Scientific Initiation Scholarship Programme(PIBIC)of the Bahia State Research Support Foundationthe Doctorate Scholarship Program of the Coordination of Improvement of Higher Education Personnel+1 种基金the Scientific Initiation Scholarship Programme(PIBIC)of the National Council for Scientific and Technological Developmentand the CNPq Research Productivity Fellowship.
文摘BACKGROUND Helicobacter pylori(H.pylori)infection has been well-established as a significant risk factor for several gastrointestinal disorders.The urea breath test(UBT)has emerged as a leading non-invasive method for detecting H.pylori.Despite numerous studies confirming its substantial accuracy,the reliability of UBT results is often compromised by inherent limitations.These findings underscore the need for a rigorous statistical synthesis to clarify and reconcile the diagnostic accuracy of the UBT for the diagnosis of H.pylori infection.AIM To determine and compare the diagnostic accuracy of 13C-UBT and 14C-UBT for H.pylori infection in adult patients with dyspepsia.METHODS We conducted an independent search of the PubMed/MEDLINE,EMBASE,and Cochrane Central databases until April 2022.Our search included diagnostic accuracy studies that evaluated at least one of the index tests(^(13)C-UBT or ^(14)C-UBT)against a reference standard.We used the QUADAS-2 tool to assess the methodo-logical quality of the studies.We utilized the bivariate random-effects model to calculate sensitivity,specificity,positive and negative test likelihood ratios(LR+and LR-),as well as the diagnostic odds ratio(DOR),and their 95%confidence intervals.We conducted subgroup analyses based on urea dosing,time after urea administration,and assessment technique.To investigate a possible threshold effect,we conducted Spearman correlation analysis,and we generated summary receiver operating characteristic(SROC)curves to assess heterogeneity.Finally,we visually inspected a funnel plot and used Egger’s test to evaluate publication bias.endorsing both as reliable diagnostic tools in clinical practice.CONCLUSION In summary,our study has demonstrated that ^(13)C-UBT has been found to outperform the ^(14)C-UBT,making it the preferred diagnostic approach.Additionally,our results emphasize the significance of carefully considering urea dosage,assessment timing,and measurement techniques for both tests to enhance diagnostic precision.Nevertheless,it is crucial for researchers and clinicians to evaluate the strengths and limitations of our findings before implementing them in practice.
文摘Screening for maternal syphilis has been an essential component of routine antenatal screening tests in most countries for many years. This is not only because of the virulence of the spirochete which causes the infection but also because of its vertical transmission rate and the potential severe adverse complications/morbidity that can result from its transmission to the fetus. Although the incidence of maternal syphilis and its fetal sequalae in low-income countries has been considerable for several years, the disease has been almost non-existent in high income countries with wide antenatal screening coverage and effective treatment programmes for Syphilis. The recent alarming increase in the incidence of maternal syphilis in high income countries has spawned a renewed public health interest in the infection, with several countries updating and strengthening public health guidance in an attempt to stem this dramatic trend. This is a short clinical update for the practising obstetrician on how to manage the antenatal patient with a positive syphilis screening test.
文摘Intelligent penetration testing is of great significance for the improvement of the security of information systems,and the critical issue is the planning of penetration test paths.In view of the difficulty for attackers to obtain complete network information in realistic network scenarios,Reinforcement Learning(RL)is a promising solution to discover the optimal penetration path under incomplete information about the target network.Existing RL-based methods are challenged by the sizeable discrete action space,which leads to difficulties in the convergence.Moreover,most methods still rely on experts’knowledge.To address these issues,this paper proposes a penetration path planning method based on reinforcement learning with episodic memory.First,the penetration testing problem is formally described in terms of reinforcement learning.To speed up the training process without specific prior knowledge,the proposed algorithm introduces episodic memory to store experienced advantageous strategies for the first time.Furthermore,the method offers an exploration strategy based on episodic memory to guide the agents in learning.The design makes full use of historical experience to achieve the purpose of reducing blind exploration and improving planning efficiency.Ultimately,comparison experiments are carried out with the existing RL-based methods.The results reveal that the proposed method has better convergence performance.The running time is reduced by more than 20%.
文摘Since the beginning of COVID-19 pandemics many countries were facing challenges with testing capacity recourse limitations. Throughout the waves of the pandemic countries were trying to address the existing constrains exploring solutions to increase the testing capacity with more cost-effective approaches. Pooled methodology was one of the methods which many have validated and used. It is evident that in case of pooled sample testing the sensitivity becomes lower, however the variation highly depends on the pool size as well as the incidence rate at the certain point. Armenia as well as many other countries has adopted regulations for mandatory COVID-19 PCR testing for all the travelers. Current study aimed to explore the efficiency of COVID-19 pooled PCR testing for nasopharyngeal swabs of individuals with no symptoms in a time period with good epidemiological state of the infection. Nasopharingeal swab samples from individuals were collected. The manual extraction of RNAs of samples was performed after pooling up to 5 samples. The pools with Cycle Threshold (CT) of < 37 were considered positive and were retested individually. In total 28,015 samples were grouped in 667 pools of which 57 were positive. The total number of positive samples was 65. The median difference (CT-pool–CT samples) was 2.4 (ranging from–3.0 to 8.9). The correlation of CT of pools and positive samples was positive. The correlation coefficient r = 0.84, P < 0.000, 95% CI range 0.7423 to 0.9243). The total economic saving when using pools compared to the individual testing was 72%. The minor difference between CT values of pools and samples can be explained by the dilution effect in the pool. However, the positive correlation between the values as well as the amount of cost saving demonstrate that pooling on nasopharyngeal samples for COVID-19 PCR testing can be a good method for efficient screening with significant resource saving. One of the most important advantages of the proposed method is the fact that samples are pooled prior extraction, which avoids the possibilities with misinterpretation of IC due to low yield of RNA in the extraction process.
文摘Background and Objective: HIV, hepatitis B virus (HBV) and hepatitis C virus (HCV) are very widespread in the world, however, less than 20% of the people affected are diagnosed and treated. This study aimed to determine the prevalence of HIV, HCV and HBV co-infections in pregnant women at Bangui Community University Hospital and the cost of screening. Methods: A cross-sectional study involving consenting pregnant women who came for antenatal care was performed. HIV, HCV antibodies and HBV antigens were detected using Exacto Triplex<sup>?</sup> HIV/HCV/HBsAg rapid test, cross-validated by ELISA tests. Sociodemographic and professional data, the modes of transmission and prevention of HIV and both hepatitis viruses were collected in a standard sheet and analyzed using the Epi-Info software version 7. Results: Pregnant women aged 15 to 24 were the most affected (45.3%);high school girls (46.0%), and pregnant women living in cohabitation (65.3%) were the most represented. Twenty-five (16.7%) worked in the formal sector, 12.7% were unemployed housewives and the remainder in the informal sector. The prevalence of HIV, HBV, and HCV viruses was 11.8%, 21.9% and 22.2%, respectively. The prevalence of co-infections was 8.6% for HIV-HBV, 10.2% for HIV-HCV, 14.7% for HBV-HCV and 6.5% for HIV-HBV-HCV. All positive results and 10% of negative results by the rapid test were confirmed by ELISA tests. The serology of the three viruses costs 39,000 FCFA (60 Euros) by ELISA compared to 10,000 FCFA (15.00 Euros) with Exacto Triplex<sup>?</sup> HIV/HCV/AgHBs (BioSynex, Strasbourg, France). Conclusion: The low level of education and awareness of hepatitis are barriers to development and indicate the importance of improving the literacy rate of women in the Central African Republic (CAR). Likewise, the high prevalence of the three viruses shows the need for the urgent establishment of a national program to combat viral hepatitis in the CAR.
文摘1) Background: Rapid and acurate diagnostic testing for case identification, quarantine, and contact tracing is essential for managing the COVID 19 pandemic. Rapid antigen detection tests are available, however, it is important to evaluate their performances before use. We tested a rapid antigen detection of SARS-CoV-2, based on the immunochromatography (Boson Biotech SARS-CoV-2 Ag Test (Xiamen Boson Biotech Co., Ltd., China)) and the results were compared with the real time reverse transcriptase-Polymerase chain reaction (RT-PCR) (Gold standard) results;2) Methods: From November 2021 to December 2021, samples were collected from symptomatic patients and asymptomatic individuals referred for testing in a hospital during the second pandemic wave in Gabon. All these participants attending “CTA Angondjé”, a field hospital set up as part of the management of COVID-19 in Gabon. Two nasopharyngeal swabs were collected in all the patients, one for Ag test and the other for RT-PCR;3) Results: A total of 300 samples were collected from 189 symptomatic and 111 asymptomatic individuals. The sensitivity and specificity of the antigen test were 82.5% [95%CI 73.8 - 89.3] and 97.9 % [95%CI 92.2 - 98.2] respectively, and the diagnostic accuracy was 84.4% (95% CI: 79.8 - 88.3%). The antigen test was more likely to be positive for samples with RT-PCR Ct values ≤ 32, with a sensitivity of 89.8%;4) Conclusions: The Boson Biotech SARS-CoV-2 Ag Test has good sensitivity and can detect SARS-CoV-2 infection, especially among symptomatic individuals with low viral load. This test could be incorporated into efficient testing algorithms as an alternative to PCR to decrease diagnostic delays and curb viral transmission.
文摘Rapid and timely testing is essential to minimize the COVID-19 spread. Decision makers and policy planners need to determine the equal distribution and accessibility of testing sites. This study mainly examines the spatial equality of COVID-19 testing sites that maintain a zero COVID policy in Guangzhou City. The study has identified the spatial disparities of COVID testing sites, characteristics of testing locations, and accessibility. The study has obtained information on COVID testing sites in Guangzhou City and population data. Point pattern analyses, Euclidian distance and allocation, and network analyses are the main methods used to achieve the research objectives, and 1183 total COVID testing sites can be recognized in Guangzhou City. Results revealed that spatial disparities could be noticed over the study area. Testing locations of Guangzhou City are highly clustered. The most significant testing sites are located in Haizhu District, which has the third largest population. The highest population density can be identified in Yuexiu District. However, only 94 testing sites are located there. According to all the results, higher disparities can be identified, and a lack of testing sites is located in the north part of the study area. Some people in the northern part have to travel more than 10 km to reach a testing site. Finally, this paper suggests increasing the number of testing sites in the north and south parts of the study area and keeping the same distribution, considering the area, total population, and population density. This kind of research will be helpful to decision-makers in making proper decisions to maintain a zero COVID policy.
文摘Background: When continuous scale measurements are available, agreements between two measuring devices are assessed both graphically and analytically. In clinical investigations, Bland and Altman proposed plotting subject-wise differences between raters against subject-wise averages. In order to scientifically assess agreement, Bartko recommended combining the graphical approach with the statistical analytic procedure suggested by Bradley and Blackwood. The advantage of using this approach is that it enables significance testing and sample size estimation. We noted that the direct use of the results of the regression is misleading and we provide a correction in this regard. Methods: Graphical and linear models are used to assess agreements for continuous scale measurements. We demonstrate that software linear regression results should not be readily used and we provided correct analytic procedures. The degrees of freedom of the F-statistics are incorrectly reported, and we propose methods to overcome this problem by introducing the correct analytic form of the F statistic. Methods for sample size estimation using R-functions are also given. Results: We believe that the tutorial and the R-codes are useful tools for testing and estimating agreement between two rating protocols for continuous scale measurements. The interested reader may use the codes and apply them to their available data when the issue of agreement between two raters is the subject of interest.
基金supported by the National Natural Science Foundation(81871691)the Beijing Municipal Natural Science Foundation(KZ202110025034).
文摘Dear Editor,The tuberculin skin test(TST)reagents have continuously improved,with the ESAT6-CFP10(EC)test having recently been introduced,but are seldom based on the direction of the delayed-type hypersensitivity(DTH)mechanism.Previous studies only partially showed the infiltration and activation of immune cells and the production of cytokines of the skin induration[1,2],and lack the detailed measurements of cell proportions and gene expression in the DTH response.Therefore,in this study,we revealed the comprehensive characteristics of DTH by single-cell RNA sequencing(scRNA-seq)in the guinea pig tuberculosis(TB)model[Experimental Animal Welfare Ethics Committee,Beijing Tuberculosis and Thoracic Tumor Research Institute(2021-064)].
文摘Ultrasonic baths and sonochemical reactors are widely used in industrial applications dealing with surface cleaningand chemical synthesis. The processes of erosion, cleaning and structuring of the surface can be typically controlledby changing relevant influential parameters. In particular, in this work, we experimentally investigate theeffect of NaCl concentration (0–5.5 mol/L) on the erosion of an aluminum foil under ultrasonic exposure at afrequency of 28 kHz. Special attention is paid to the determination of cavitation zones and their visualizationusing heat maps. It is found that at low NaCl concentration (0.3 mol/L), the foil destruction rate is higher thanin distilled water. At higher concentrations of salt, cavitation takes place mainly in the upper part of the container.
文摘AIM:To investigate the efficacy of a new visual acuity(VA)screening method,the baby vision test for young children.METHODS:A total 105 eyes of 65 children aged 2-8y were included in the study.Acuity testing was conducted using a standardized recognition acuity chart(Snellen visual chart:at 3 m)and the baby vision model assessment.The baby vision device includes a screen,a near infrared camera and a computer.Children were seated at a measured distance of 33-40 cm from a display for testing.VA was estimated according to the highest resolution the children could follow.Decimal VA data were converted to logarithm of the minimum angle of resolution(logMAR)for statistical analysis.The VA results for each child were recorded and analyzed for consistency.RESULTS:The mean VA measured using the Snellen visual chart was 0.62±0.32,and that assessed using the baby vision test was 0.66±0.27.The 95%limit of agreement was-0.609 to 0.695,with 95.2%(100/105)plots within the 95%limits of agreement.VA values of the baby vision test were significantly correlated with those of the Snellen chart(R=0.274,P=0.005).CONCLUSION:The baby vision test can be used as a relatively reliable method for estimating VA in young children.This new acuity assessment might be a valid predictor of optotype-measured acuity later in preverbal children.