The reliability of the eddy current testing (ECT) in flaw detection is quantitatively evaluated by theprobability of detection (POD). Precise and efficient modeling of POD gives direction for the implement of ECTon si...The reliability of the eddy current testing (ECT) in flaw detection is quantitatively evaluated by theprobability of detection (POD). Precise and efficient modeling of POD gives direction for the implement of ECTon sites to avoid false or missing flaw detection. Traditional POD analysis focuses on single uncertain factor orsingle response signal with limited credibility in engineering. This paper considers multiple response signals andmultiple flaw parameters to perform POD. The flaw length, the flaw depth, the coil impedance, and the magneticflux density are comprehensively studied under various lift-off distances. A finite element model (FEM) of ECT isestablished and verified with experiments to obtain sufficient simulation data for discrete POD modeling. Thecontinuous POD function is then fitted based on the discrete values to show the superiority of integrating multiplefactors. A comparison with conventional POD analysis further demonstrates the higher reliability of ECT flawdetection considering multiple flaw parameters and multiple response signals, especially for small flaws.展开更多
A flexible or planar eddy current probe with a differential structure can suppress the lift-off noise during the inspection of defects.However,the extent of the lift-off effect on differential probes,including differe...A flexible or planar eddy current probe with a differential structure can suppress the lift-off noise during the inspection of defects.However,the extent of the lift-off effect on differential probes,including different coil structures,varies.In this study,two planar eddy current probes with differential pickup structures and the same size,Koch and circular probes,were used to compare lift-off effects.The eddy current distributions of the probes perturbed by 0°and 90°cracks were obtained by finite element analysis.The analysis results show that the 90°crack can impede the eddy current induced by the Koch probe even further at relatively low lift-off distance.The peak-to-peak values of the signal output from the two probes were compared at different lift-off distances using finite element analysis and experimental methods.In addition,the effects of different frequencies on the lift-off were studied experimentally.The results show that the signal peak-to-peak value of the Koch probe for the inspection of cracks in 90°orientation is larger than that of the circular probe when the lift-off distance is smaller than 1.2 mm.In addition,the influence of the lift-off distance on the peak-to-peak signal value of the two probes was studied via normalization.This indicates that the influence becomes more evident with an increase in excitation frequency.This research discloses the lift-off effect of differential planar eddy current probes with different coil shapes and proves the detection merit of the Koch probe for 90°cracks at low lift-off distances.展开更多
New materials and manufacturing technologies require applicable non-destructive techniques for quality assurance so as to achieve better performance.This study comprehensively investigated the effect of influencing fa...New materials and manufacturing technologies require applicable non-destructive techniques for quality assurance so as to achieve better performance.This study comprehensively investigated the effect of influencing factors includ-ing excitation frequency,lift-off distance,defect depth and size,residual heat,and surface roughness on the defect EC signals of an Inconel 738LC alloy produced by selective laser melting(SLM).The experimental investigations recorded the impedance amplitude and phase angle of EC signals for each defect to explore the feasibility of detecting sub-surface defects by merely analyzing these two key indicators.Overall,this study revealed preliminary qualitative and roughly quantitative relationships between influencing factors and corresponding EC signals,which provided a prac-tical reference on how to quantitively inspect subsurface defects using eddy current testing(ECT)on SLMed parts,and also made solid progress toward on-line ECT in additive/subtractive hybrid manufacturing(ASHM)for fabricating SLMed parts with enhanced quality and better performance.展开更多
Luquire et al. ' s impedance change model of a rectangular cross section probe coil above a structure with an arbitrary number of parallel layers was used to study the principle of measuring thicknesses of multi-l...Luquire et al. ' s impedance change model of a rectangular cross section probe coil above a structure with an arbitrary number of parallel layers was used to study the principle of measuring thicknesses of multi-layered structures in terms of eddy current testing voltage measurements. An experimental system for multi-layered thickness measurement was developed and several fitting models to formulate the relationships between detected impedance/voltage measurements and thickness are put forward using least square method. The determination of multi-layered thicknesses was investigated after inversing the voltage outputs of the detecting system. The best fitting and inversion models are presented.展开更多
CFRP (carbon fiber reinforced plastic) is used extensively in aircraft and spacecraft structures, because of its excellent mechanical properties. Ultrasonic testing, which is used as a non-destructive testing techni...CFRP (carbon fiber reinforced plastic) is used extensively in aircraft and spacecraft structures, because of its excellent mechanical properties. Ultrasonic testing, which is used as a non-destructive testing technique for CFRP, requires a contact medium. In contrast, eddy current testing does not require a contact medium, and when used for CFRP testing it has advantages not available with other techniques. CFRP is a laminate, with each layer being anisotropically conductive, and the distribution of the induced eddy current is yet to be determined. Here, to determine the eddy current distribution in the detection of flaws in cross-ply CFRP (0°/90°) by using a cross-point probe, we performed an FEM (finite element method) analysis of electromagnetic fields. We investigated the nature of the flaw signals and the differences in eddy current distributions between materials with and without flaws.展开更多
Due to the electrical anisotropy of carbon fiber reinforced polymer(CFRP),this paper presents a method to inverse the anisotropic conductivity of unidirectional CFRP laminate using eddy current testing(ECT). The relat...Due to the electrical anisotropy of carbon fiber reinforced polymer(CFRP),this paper presents a method to inverse the anisotropic conductivity of unidirectional CFRP laminate using eddy current testing(ECT). The relationship between the conductivity and probe signal of ECT is studied by means of numerical simulation. Finally,the accuracy of inversion result is improved by optimizing the initial conductivity by use of experimental data.展开更多
The paper addresses the first eddy current benchmark problem proposed by the World Federation of Nondestructive Evaluation Centers (WFNDEC). The problem simulates the eddy current response to the presence of an axisym...The paper addresses the first eddy current benchmark problem proposed by the World Federation of Nondestructive Evaluation Centers (WFNDEC). The problem simulates the eddy current response to the presence of an axisymmetric circumferential defect in an Inconel-600 tube. All simulations employ the axisymmetric code of the electromagnetic field simulator Finite Element Method Magnetics. For three different frequencies of excitation, it is explained how the displacement of the detecting coil inside the tube leads to a variation in the impedance of the eddy current coil. Variations of the resistive and inductive components of the impedance with distance from the defect region are used to build the impedance trajectory for each frequency of analysis.展开更多
In eddy current testing, the law of attenuation of eddy current(EC) is of great concern. In conductive half space under the excitation of uniform magnetic field, the EC density decreases exponentially in the depth dir...In eddy current testing, the law of attenuation of eddy current(EC) is of great concern. In conductive half space under the excitation of uniform magnetic field, the EC density decreases exponentially in the depth direction. However, in conductor with finite thickness tested by coil, the distribution of EC in the depth direction is more complicated. This paper studies the characteristics of EC attenuation in metallic plate of finite thickness. Simulation results show that there is an EC reflection at the bottom of plate, which changes the law of EC attenuation. A new concept, namely the equivalent attenuation coefficient, is proposed to quantify the speed of EC attenuation. The characteristics of EC attenuation are utilized to explain the nonmonotonic relation between coil voltage and plate thickness. Procedure of selecting frequency is discussed. Thereafter, measurement of plate thickness is carried out and accurate result is obtained.展开更多
The Chinese Proficiency Test(HSK)is a standardized test on Chinese language skills which has been widely introduced both in and outside China and has been playing an important role in the spread of Chinese learning al...The Chinese Proficiency Test(HSK)is a standardized test on Chinese language skills which has been widely introduced both in and outside China and has been playing an important role in the spread of Chinese learning all over the world.In 2003 Bulgaria hosted a beginner level HSK exam,which made it the first location to hold a Chinese language proficiency test on the Balkan Peninsula and ever since it has been very successful.The current paper provides a research on the current state of the Chinese Proficiency Test(HSK)аt the Confucius Institute in Sofia,Bulgaria,analyzes the factors related to the promotion of the Chinese Proficiency Test(HSK)and on this basis presents a few feasible recommendations to the benefit of the Chinese Proficiency Test(HSK).展开更多
There are several elements that affect on the integrity of steam generator tubes. One of the elements is loose parts located on outside of the tubes. It causes erosion which is possible to lead fatal defect like crack...There are several elements that affect on the integrity of steam generator tubes. One of the elements is loose parts located on outside of the tubes. It causes erosion which is possible to lead fatal defect like crack on the outside surface of the tubes. In this study, artificial loose parts on Inconel 690 tube are demonstrated and eddy current testing data of the region is acquired using rotating probe. Ferromagnetic and nonmagnetic foreign materials were used to demonstrate artificial loose parts. Eddy current channel of 100 KHz frequency shows definite signals of those foreign materials but stainless steel was not clearly detected. This result can be explained based on the electrical conductivity of the materials and it can be confirmed with lissajous window and C-scan. In addition, no indication was detected when the distance of the gap between the foreign materials and the tube is increased to more than 3 mm under this test condition. Based on these experimental inspections, we were able to find suitable methods for analyzing the signals obtained under various conditions that could occur when conducting steam generator eddy current test in NPP.展开更多
A differential excitation probe based on eddy current testing technology was designed. Sheet specimens of Q 235 steel with prefabricated micro-cracks of different widths and of aluminum with prefabricated micro-cracks...A differential excitation probe based on eddy current testing technology was designed. Sheet specimens of Q 235 steel with prefabricated micro-cracks of different widths and of aluminum with prefabricated micro-cracks of different depths were detected through the designed detection system. The characteristics of micro-cracks can be clearly showed after signals processing through the short-time Fourier transform( STFT). By changing the parameter and its value in detecting process,the factors including the excitation frequency and amplitude,the lift-off effect and the scanning direction were discussed,respectively. The results showed that the differential excitation probe was insensitive to dimension and surface state of the tested specimen,while it had a high degree of recognition for micro-crack detection. Therefore,when the differential excitation detection technology was used for inspecting micro-crack of turbine blade in aero-engine,and smoothed pseudo Wigner-Ville distribution was used for signal processing,micro-cracks of 0. 3 mm depth and 0. 1 mm width could be identified. The experimental results might be useful for further research on engineering test of turbine blades of aero-engine.展开更多
Eddy current (EC) distribution induced by EC sensors determines the interaction between the defectin the testing specimen and the EC, so quantitatively evaluating EC distribution is crucial to the design of ECsensors....Eddy current (EC) distribution induced by EC sensors determines the interaction between the defectin the testing specimen and the EC, so quantitatively evaluating EC distribution is crucial to the design of ECsensors. In this study, two indices based on the information entropy are proposed to evaluate the EC energyallocated in different directions. The EC vectors induced by a rotational field EC sensor varying in the timedomain are evaluated by the proposed methods. Then, the evaluating results are analyzed by the principle ofEC testing. It can be concluded that the two indices can effectively quantitatively evaluate the EC distributionsvarying in the time domain and are used to optimize the parameters of the rotational EC sensors.展开更多
Composite materials are increasingly used in the aerospace industry.To fully realise the weight saving potential along with superior mechanical properties that composites offer in safety critical applications,reliable...Composite materials are increasingly used in the aerospace industry.To fully realise the weight saving potential along with superior mechanical properties that composites offer in safety critical applications,reliable Non-Destructive Testing(NDT)methods are required to prevent catastrophic failures.This paper will review the state of the art in the field and point to highlight the success and challenges that different NDT methods are faced to evaluate the integrity of critical aerospace composites.The focus will be on advanced certificated NDT methods for damage detection and characterization in composite laminates for use in the aircraft primary and secondary structures.展开更多
An ultra-thin flexible eddy current proximity sensor array was developed for online measurements of tiny gaps between large smooth metallic and nonmetallic surfaces of arbitrary shapes. The probe of the flexible eddy ...An ultra-thin flexible eddy current proximity sensor array was developed for online measurements of tiny gaps between large smooth metallic and nonmetallic surfaces of arbitrary shapes. The probe of the flexible eddy current sensor array, which includes a set of sensor coils, is fabricated on a thin flexible substrate using the flexible printed circuit board process which allows the probe to be very thin and flexible so that it can conform to the surface geometry of the measured objects. The sensor coils are connected to an inductance-capacitance oscillator, which converts the distance between the sensor coil and the metallic target to a frequency output. Experimental results show that the measurement accuracy of the sensor system can reach ±0.5% for a 2-mm gap and the sensor system is suitable for online gap measurements.展开更多
The current interruption test based on an LC resonance circuit for hybrid DC circuit breakers(HVDC CBs)is widely employed to characterize the current interruption capability of CBs.In order to ensure a high-fidelity r...The current interruption test based on an LC resonance circuit for hybrid DC circuit breakers(HVDC CBs)is widely employed to characterize the current interruption capability of CBs.In order to ensure a high-fidelity replica of the fault current in a high voltage application,this paper first proposes an equivalent model of the test circuit,where not only parasitic resistances but also the threshold voltages and on-state resistances of various semiconductor devices are considered.Moreover,the analytical formula of the test current is derived by including the working principle of the HVDC CB.Secondly,the parameter extraction method,which combines finite element analysis and measurements by an impedance analyzer,is given in this paper.The extracted result implies that,in current interruption transients,equivalent resistances of 500 kV CB are as large as 535 mS,which have a significant influence on current waveforms.Thirdly,the 34 kV/25 kA current interruption test for the 500 kV CB is conducted.The measured results are proved to be consistent with the analytical results obtained from the proposed model,and the relative error is less than 2%.展开更多
In this paper,a simple numerical model of offshore currents is presented. A calculation scheme based on the isometric,implicit difference method is used and the points at which various physical quantities are computed...In this paper,a simple numerical model of offshore currents is presented. A calculation scheme based on the isometric,implicit difference method is used and the points at which various physical quantities are computed are distributed in a staggered form.The finite difference scheme designed here conserve total generalized energy and it is solved by splitting into three systems,namely,the adjustment,development and dissipation processes.The results of the numerical verification indicate that this scheme is computational stable,and the simulated results are encouraging.展开更多
The noise as an undesired phenomenon often appears in the pulsed eddy current testing(PECT)signal, and it is difficult to recognize the character of the testing signal. One of the most common noises presented in the P...The noise as an undesired phenomenon often appears in the pulsed eddy current testing(PECT)signal, and it is difficult to recognize the character of the testing signal. One of the most common noises presented in the PECT signal is the Gaussian noise, since it is caused by the testing environment. A new denoising approach based on singular value decomposition(SVD) is proposed in this paper to reduce the Gaussian noise of PECT signal. The approach first discusses the relationship between signal to noise ratio(SNR) and negentropy of PECT signal. Then the Hankel matrix of PECT signal is constructed for noise reduction, and the matrix is divided into noise subspace and signal subspace by a singular valve threshold. Based on the theory of negentropy, the optimal matrix dimension and threshold are chosen to improve the performance of denoising. The denoised signal Hankel matrix is reconstructed by the singular values of signal subspace, and the denoised signal is finally extracted from this matrix. Experiment is performed to verify the feasibility of the proposed approach, and the results indicate that the proposed approach can reduce the Gaussian noise of PECT signal more effectively compared with other existing approaches.展开更多
The overheating problems of terminal connectors severely threaten the operation of ultra-high voltage projects and cause enormous losses of economy,so a higher currentcarrying reliability of the connectors has an impo...The overheating problems of terminal connectors severely threaten the operation of ultra-high voltage projects and cause enormous losses of economy,so a higher currentcarrying reliability of the connectors has an important engineering significance with the development of transmission capacity.In this paper,a bivariate mathematical model of contact resistance as functions of temperature and tightening torque was deduced based on the large current temperature rise tests.To perform such analysis,four typical terminal connectors,namely:overlapping terminal of aluminum plates,overlapping terminal of copper plates,overlapping terminal of plates with clad layer and overlapping terminal of copper rod with aluminum clamp,were chosen for the experiments.The changing rules of DC resistance with different tightening torques and different currents were studied.Then the empirical formula of contact resistance was deduced.Finally,temperature calculations of different terminal connectors were realized to verify the effectiveness of the bivariate mathematical model.展开更多
基金supported by the Key Research and Development Project of Zhejiang Province(Grant No.2023C01248,2023C01069)and the National Natural Science Foundation of China(Grant No.52375135,52305137).
文摘The reliability of the eddy current testing (ECT) in flaw detection is quantitatively evaluated by theprobability of detection (POD). Precise and efficient modeling of POD gives direction for the implement of ECTon sites to avoid false or missing flaw detection. Traditional POD analysis focuses on single uncertain factor orsingle response signal with limited credibility in engineering. This paper considers multiple response signals andmultiple flaw parameters to perform POD. The flaw length, the flaw depth, the coil impedance, and the magneticflux density are comprehensively studied under various lift-off distances. A finite element model (FEM) of ECT isestablished and verified with experiments to obtain sufficient simulation data for discrete POD modeling. Thecontinuous POD function is then fitted based on the discrete values to show the superiority of integrating multiplefactors. A comparison with conventional POD analysis further demonstrates the higher reliability of ECT flawdetection considering multiple flaw parameters and multiple response signals, especially for small flaws.
基金Supported by Gansu Provincial Natural Science Foundation of China(Grant No.22JR5RA229)National Natural Science Foundation of China(Grant Nos.51807086,12162021)Hongliu Youth Found of Lanzhou University of Technology and Gansu Provincial Outstanding Graduate Student Innovation Star of China(Grant No.2021CXZX-453).
文摘A flexible or planar eddy current probe with a differential structure can suppress the lift-off noise during the inspection of defects.However,the extent of the lift-off effect on differential probes,including different coil structures,varies.In this study,two planar eddy current probes with differential pickup structures and the same size,Koch and circular probes,were used to compare lift-off effects.The eddy current distributions of the probes perturbed by 0°and 90°cracks were obtained by finite element analysis.The analysis results show that the 90°crack can impede the eddy current induced by the Koch probe even further at relatively low lift-off distance.The peak-to-peak values of the signal output from the two probes were compared at different lift-off distances using finite element analysis and experimental methods.In addition,the effects of different frequencies on the lift-off were studied experimentally.The results show that the signal peak-to-peak value of the Koch probe for the inspection of cracks in 90°orientation is larger than that of the circular probe when the lift-off distance is smaller than 1.2 mm.In addition,the influence of the lift-off distance on the peak-to-peak signal value of the two probes was studied via normalization.This indicates that the influence becomes more evident with an increase in excitation frequency.This research discloses the lift-off effect of differential planar eddy current probes with different coil shapes and proves the detection merit of the Koch probe for 90°cracks at low lift-off distances.
基金Supported by Basic Research Project of Science and Technology Plan of Shenzhen(Grant No.JCYJ20170817111811303).
文摘New materials and manufacturing technologies require applicable non-destructive techniques for quality assurance so as to achieve better performance.This study comprehensively investigated the effect of influencing factors includ-ing excitation frequency,lift-off distance,defect depth and size,residual heat,and surface roughness on the defect EC signals of an Inconel 738LC alloy produced by selective laser melting(SLM).The experimental investigations recorded the impedance amplitude and phase angle of EC signals for each defect to explore the feasibility of detecting sub-surface defects by merely analyzing these two key indicators.Overall,this study revealed preliminary qualitative and roughly quantitative relationships between influencing factors and corresponding EC signals,which provided a prac-tical reference on how to quantitively inspect subsurface defects using eddy current testing(ECT)on SLMed parts,and also made solid progress toward on-line ECT in additive/subtractive hybrid manufacturing(ASHM)for fabricating SLMed parts with enhanced quality and better performance.
文摘Luquire et al. ' s impedance change model of a rectangular cross section probe coil above a structure with an arbitrary number of parallel layers was used to study the principle of measuring thicknesses of multi-layered structures in terms of eddy current testing voltage measurements. An experimental system for multi-layered thickness measurement was developed and several fitting models to formulate the relationships between detected impedance/voltage measurements and thickness are put forward using least square method. The determination of multi-layered thicknesses was investigated after inversing the voltage outputs of the detecting system. The best fitting and inversion models are presented.
文摘CFRP (carbon fiber reinforced plastic) is used extensively in aircraft and spacecraft structures, because of its excellent mechanical properties. Ultrasonic testing, which is used as a non-destructive testing technique for CFRP, requires a contact medium. In contrast, eddy current testing does not require a contact medium, and when used for CFRP testing it has advantages not available with other techniques. CFRP is a laminate, with each layer being anisotropically conductive, and the distribution of the induced eddy current is yet to be determined. Here, to determine the eddy current distribution in the detection of flaws in cross-ply CFRP (0°/90°) by using a cross-point probe, we performed an FEM (finite element method) analysis of electromagnetic fields. We investigated the nature of the flaw signals and the differences in eddy current distributions between materials with and without flaws.
基金supported by the research fund of State Key Laboratory of Mechanics and Control of Mechanical Structures(Nanjing University of Aeronautics and astronautics)(No. MCMS-I-0518K01&MCMSI-0519G02)Project Funded by the Priority Academic Program Development of Jiangsu Higher Education Institutions (PAPD)the Natural Science Funding (No. 51875277)
文摘Due to the electrical anisotropy of carbon fiber reinforced polymer(CFRP),this paper presents a method to inverse the anisotropic conductivity of unidirectional CFRP laminate using eddy current testing(ECT). The relationship between the conductivity and probe signal of ECT is studied by means of numerical simulation. Finally,the accuracy of inversion result is improved by optimizing the initial conductivity by use of experimental data.
文摘The paper addresses the first eddy current benchmark problem proposed by the World Federation of Nondestructive Evaluation Centers (WFNDEC). The problem simulates the eddy current response to the presence of an axisymmetric circumferential defect in an Inconel-600 tube. All simulations employ the axisymmetric code of the electromagnetic field simulator Finite Element Method Magnetics. For three different frequencies of excitation, it is explained how the displacement of the detecting coil inside the tube leads to a variation in the impedance of the eddy current coil. Variations of the resistive and inductive components of the impedance with distance from the defect region are used to build the impedance trajectory for each frequency of analysis.
基金Supported by National Natural Science Foundation of China(Grant No.51277154)Xiamen Key Laboratory of Optoelectronic Transducer Technology+1 种基金Fujian Key Laboratory of Universities and Colleges for Transducer TechnologyInnovative Talents Program of Far East NDT New Technology&Application Forum
文摘In eddy current testing, the law of attenuation of eddy current(EC) is of great concern. In conductive half space under the excitation of uniform magnetic field, the EC density decreases exponentially in the depth direction. However, in conductor with finite thickness tested by coil, the distribution of EC in the depth direction is more complicated. This paper studies the characteristics of EC attenuation in metallic plate of finite thickness. Simulation results show that there is an EC reflection at the bottom of plate, which changes the law of EC attenuation. A new concept, namely the equivalent attenuation coefficient, is proposed to quantify the speed of EC attenuation. The characteristics of EC attenuation are utilized to explain the nonmonotonic relation between coil voltage and plate thickness. Procedure of selecting frequency is discussed. Thereafter, measurement of plate thickness is carried out and accurate result is obtained.
文摘The Chinese Proficiency Test(HSK)is a standardized test on Chinese language skills which has been widely introduced both in and outside China and has been playing an important role in the spread of Chinese learning all over the world.In 2003 Bulgaria hosted a beginner level HSK exam,which made it the first location to hold a Chinese language proficiency test on the Balkan Peninsula and ever since it has been very successful.The current paper provides a research on the current state of the Chinese Proficiency Test(HSK)аt the Confucius Institute in Sofia,Bulgaria,analyzes the factors related to the promotion of the Chinese Proficiency Test(HSK)and on this basis presents a few feasible recommendations to the benefit of the Chinese Proficiency Test(HSK).
文摘There are several elements that affect on the integrity of steam generator tubes. One of the elements is loose parts located on outside of the tubes. It causes erosion which is possible to lead fatal defect like crack on the outside surface of the tubes. In this study, artificial loose parts on Inconel 690 tube are demonstrated and eddy current testing data of the region is acquired using rotating probe. Ferromagnetic and nonmagnetic foreign materials were used to demonstrate artificial loose parts. Eddy current channel of 100 KHz frequency shows definite signals of those foreign materials but stainless steel was not clearly detected. This result can be explained based on the electrical conductivity of the materials and it can be confirmed with lissajous window and C-scan. In addition, no indication was detected when the distance of the gap between the foreign materials and the tube is increased to more than 3 mm under this test condition. Based on these experimental inspections, we were able to find suitable methods for analyzing the signals obtained under various conditions that could occur when conducting steam generator eddy current test in NPP.
基金Supported by the Ministerial Level Advanced Research Foundation(051317030586)Ph.D.Programs Foundation of the Ministry of Education of China(20121101110018)
文摘A differential excitation probe based on eddy current testing technology was designed. Sheet specimens of Q 235 steel with prefabricated micro-cracks of different widths and of aluminum with prefabricated micro-cracks of different depths were detected through the designed detection system. The characteristics of micro-cracks can be clearly showed after signals processing through the short-time Fourier transform( STFT). By changing the parameter and its value in detecting process,the factors including the excitation frequency and amplitude,the lift-off effect and the scanning direction were discussed,respectively. The results showed that the differential excitation probe was insensitive to dimension and surface state of the tested specimen,while it had a high degree of recognition for micro-crack detection. Therefore,when the differential excitation detection technology was used for inspecting micro-crack of turbine blade in aero-engine,and smoothed pseudo Wigner-Ville distribution was used for signal processing,micro-cracks of 0. 3 mm depth and 0. 1 mm width could be identified. The experimental results might be useful for further research on engineering test of turbine blades of aero-engine.
基金Foundation item:the National Natural Science Foundation of China(No.51807086)the Young Doctoral Fund of Education Department of Gansu Province(No.2021QB-047)the Hongliu Youth Fund of Lanzhou University of Technology(No.07/062003)。
文摘Eddy current (EC) distribution induced by EC sensors determines the interaction between the defectin the testing specimen and the EC, so quantitatively evaluating EC distribution is crucial to the design of ECsensors. In this study, two indices based on the information entropy are proposed to evaluate the EC energyallocated in different directions. The EC vectors induced by a rotational field EC sensor varying in the timedomain are evaluated by the proposed methods. Then, the evaluating results are analyzed by the principle ofEC testing. It can be concluded that the two indices can effectively quantitatively evaluate the EC distributionsvarying in the time domain and are used to optimize the parameters of the rotational EC sensors.
基金the support of NVIDIA Corporation with the donation of the Titan Xp GPU used for this researchsupported by EPSRC grant EP/R002495/1the European Metrology Research Programme through grant 17IND08。
文摘Composite materials are increasingly used in the aerospace industry.To fully realise the weight saving potential along with superior mechanical properties that composites offer in safety critical applications,reliable Non-Destructive Testing(NDT)methods are required to prevent catastrophic failures.This paper will review the state of the art in the field and point to highlight the success and challenges that different NDT methods are faced to evaluate the integrity of critical aerospace composites.The focus will be on advanced certificated NDT methods for damage detection and characterization in composite laminates for use in the aircraft primary and secondary structures.
文摘An ultra-thin flexible eddy current proximity sensor array was developed for online measurements of tiny gaps between large smooth metallic and nonmetallic surfaces of arbitrary shapes. The probe of the flexible eddy current sensor array, which includes a set of sensor coils, is fabricated on a thin flexible substrate using the flexible printed circuit board process which allows the probe to be very thin and flexible so that it can conform to the surface geometry of the measured objects. The sensor coils are connected to an inductance-capacitance oscillator, which converts the distance between the sensor coil and the metallic target to a frequency output. Experimental results show that the measurement accuracy of the sensor system can reach ±0.5% for a 2-mm gap and the sensor system is suitable for online gap measurements.
基金supported by Science and Technology Project of State Grid Corporation of China(No.520201190095).
文摘The current interruption test based on an LC resonance circuit for hybrid DC circuit breakers(HVDC CBs)is widely employed to characterize the current interruption capability of CBs.In order to ensure a high-fidelity replica of the fault current in a high voltage application,this paper first proposes an equivalent model of the test circuit,where not only parasitic resistances but also the threshold voltages and on-state resistances of various semiconductor devices are considered.Moreover,the analytical formula of the test current is derived by including the working principle of the HVDC CB.Secondly,the parameter extraction method,which combines finite element analysis and measurements by an impedance analyzer,is given in this paper.The extracted result implies that,in current interruption transients,equivalent resistances of 500 kV CB are as large as 535 mS,which have a significant influence on current waveforms.Thirdly,the 34 kV/25 kA current interruption test for the 500 kV CB is conducted.The measured results are proved to be consistent with the analytical results obtained from the proposed model,and the relative error is less than 2%.
文摘In this paper,a simple numerical model of offshore currents is presented. A calculation scheme based on the isometric,implicit difference method is used and the points at which various physical quantities are computed are distributed in a staggered form.The finite difference scheme designed here conserve total generalized energy and it is solved by splitting into three systems,namely,the adjustment,development and dissipation processes.The results of the numerical verification indicate that this scheme is computational stable,and the simulated results are encouraging.
文摘The noise as an undesired phenomenon often appears in the pulsed eddy current testing(PECT)signal, and it is difficult to recognize the character of the testing signal. One of the most common noises presented in the PECT signal is the Gaussian noise, since it is caused by the testing environment. A new denoising approach based on singular value decomposition(SVD) is proposed in this paper to reduce the Gaussian noise of PECT signal. The approach first discusses the relationship between signal to noise ratio(SNR) and negentropy of PECT signal. Then the Hankel matrix of PECT signal is constructed for noise reduction, and the matrix is divided into noise subspace and signal subspace by a singular valve threshold. Based on the theory of negentropy, the optimal matrix dimension and threshold are chosen to improve the performance of denoising. The denoised signal Hankel matrix is reconstructed by the singular values of signal subspace, and the denoised signal is finally extracted from this matrix. Experiment is performed to verify the feasibility of the proposed approach, and the results indicate that the proposed approach can reduce the Gaussian noise of PECT signal more effectively compared with other existing approaches.
基金This work was supported by the National Natural Science Foundation of China(51678548)the Science and Technology Project of the State Grid Corporation of China(GC71-16-003).
文摘The overheating problems of terminal connectors severely threaten the operation of ultra-high voltage projects and cause enormous losses of economy,so a higher currentcarrying reliability of the connectors has an important engineering significance with the development of transmission capacity.In this paper,a bivariate mathematical model of contact resistance as functions of temperature and tightening torque was deduced based on the large current temperature rise tests.To perform such analysis,four typical terminal connectors,namely:overlapping terminal of aluminum plates,overlapping terminal of copper plates,overlapping terminal of plates with clad layer and overlapping terminal of copper rod with aluminum clamp,were chosen for the experiments.The changing rules of DC resistance with different tightening torques and different currents were studied.Then the empirical formula of contact resistance was deduced.Finally,temperature calculations of different terminal connectors were realized to verify the effectiveness of the bivariate mathematical model.