Amid the growing interest in triboelectric nanogenerators(TENGs)as novel energy-harvesting devices,several studies have focused on direct current(DC)TENGs to generate a stable DC output for operating electronic device...Amid the growing interest in triboelectric nanogenerators(TENGs)as novel energy-harvesting devices,several studies have focused on direct current(DC)TENGs to generate a stable DC output for operating electronic devices.However,owing to the working mechanisms of conventional DC TENGs,generating a stable DC output from reciprocating motion remains a challenge.Accordingly,we propose a bidirectional rotating DC TENG(BiR-TENG),which can generate DC outputs,regardless of the direction of rotation,from reciprocating motions.The distinct design of the BiR-TENG enables the mechanical rectification of the alternating current output into a rotational-direction-dependent DC output.Furthermore,it allows the conversion of the rotational-direction-dependent DC output into a unidirectional DC output by adapting the configurations depending on the rotational direction.Owing to these tailored design strategies and subsequent optimizations,the BiR-TENG could generate an effective unidirectional DC output.Applications of the BiR-TENG for the reciprocating motions of swinging doors and waves were demonstrated by harnessing this output.This study demonstrates the potential of the BiR-TENG design strategy as an effective and versatile solution for energy harvesting from reciprocating motions,highlighting the suitability of DC outputs as an energy source for electronic devices.展开更多
The key plasma parameters under different discharge modes, such as heavy-particle and electron temperatures, electron number density, and nonequilibrium volume of plasmas, play important roles in various applications ...The key plasma parameters under different discharge modes, such as heavy-particle and electron temperatures, electron number density, and nonequilibrium volume of plasmas, play important roles in various applications of gas discharge plasmas. In this study, a self-consistent two-dimensional nonequilibrium fluid model coupled with an external circuit model is established to reveal the mechanisms related to the discharge modes, including the normal glow, abnormal glow,arc, and glow-to-arc transition modes, with an atmospheric-pressure direct-current(DC) argon discharge as a model plasma system. The modeling results show that, under different discharge modes, the most significant difference between the preceding four discharge modes lies in the current and energy transfer processes on the cathode side. On one hand, the current to the cathode surface is mainly delivered by the ions coming from the plasma column under the glow discharge mode due to the low temperature of the solid cathode, whereas the thermionic and secondary electrons emitted from the hot cathode surface play a very important role under the arc mode with a higher cathode surface temperature and higher ion flux toward the cathode. On the other hand, the energy transfer channel on the cathode side changes from mainly heating the solid cathode under the glow mode to simultaneously heating both the solid cathode and plasma column under the arc mode with an increase in the discharge current. Consequently, the power density in the cathode sheath(P_c) was used as a key parameter for judging different discharge modes, and the range of(0.28–1.2) × 10^(12) W m^(-3) was determined as a critical window of P_c corresponding to the glow-to-arc-mode transition for the atmospheric-pressure DC argon discharge, which was also verified by comparison with the experimental results in this study and the data in the previous literature.展开更多
The ESA and CAS SMILE mission orbit is highly elliptical and will pass through multiple radiation environments.The Soft X-ray Imager(SXI)instrument aboard has a radiation shutter door designed to close when the surrou...The ESA and CAS SMILE mission orbit is highly elliptical and will pass through multiple radiation environments.The Soft X-ray Imager(SXI)instrument aboard has a radiation shutter door designed to close when the surrounding radiation flux is high.The shutter door will close when passing below an altitude threshold to protect against trapped particles in the Earth’s Van Allen Belts.Therefore,two radiation environments can be approximated based on the shutter door position:open and closed.The instrument background for the CCDs(Charge-Coupled Devices)that form the focal plane array of the SXI were evaluated for the two environments.Due to the correlation of the space environment with the solar cycle,the solar minima and maxima,the background was also evaluated at these two extremes.The results demonstrated that the highest instrument background will occur during solar minima due to the main contributing source being Galactic Cosmic Rays(GCRs).It was also found that the open background was highest for solar minima and that the closed background was highest during solar maxima.This is due to the radiation shutter door acting as a scattering centre and the changes in the energy flux distribution of the GCRs between the two solar extremes.展开更多
Dear Readers:Astronomical Techniques and Instruments is a professional English journal of open access devoted to recent develop-ments,discoveries,and theories in astronomical techniques,methods,and instruments.It will...Dear Readers:Astronomical Techniques and Instruments is a professional English journal of open access devoted to recent develop-ments,discoveries,and theories in astronomical techniques,methods,and instruments.It will serve as a platform for dis-course,learning,and information sharing for astronomic and astrophysics professionals worldwide.展开更多
Through the online and offline practical reform of the Modern Instrumental Analysis course of biotechnology majors from teaching content,teaching method,teaching demonstration to teaching effect,the traditional single...Through the online and offline practical reform of the Modern Instrumental Analysis course of biotechnology majors from teaching content,teaching method,teaching demonstration to teaching effect,the traditional single offline lecture is transformed into diversified and interactive modern teaching.The practical reform enriches and optimizes the course content,perfects and improves the course assessment system,and improves the teaching quality.It achieves the student-centered and application-oriented teaching goal,and also provides reference for further cultivating high-quality applied talents.展开更多
Introduction: The choice of adopting unilateral pedicle screw fixation or using bilateral pedicle screw fixation in lumbar spinal stenosis remains controversial. In our context, very few studies have been performed co...Introduction: The choice of adopting unilateral pedicle screw fixation or using bilateral pedicle screw fixation in lumbar spinal stenosis remains controversial. In our context, very few studies have been performed comparing the clinical effectiveness of unilateral versus bilateral fixation in the surgical management of lumbar spinal canal stenosis. Objective: Evaluate the impact on quality of life and clinical efficacy of unilateral spondylodesis compared to bilateral spondylodesis in the surgical management of lumbar spinal canal stenosis at the Yaounde Central Hospital. Methods: This was a retrospective descriptive cross-sectional study for a period of 4 years, from June 2015 to June 2019. It involved all patients operated for lumbar canal stenosis and who underwent spondylodesis or spinal fusion at the neurosurgery department of the Yaounde Central Hospital. Results: A total of 68 participants were recruited during our study period. 32 (47%) of the study population were in the 50 - 60 age group, with a mean age of 56.98 years ranging from 41 to 75 years. Females, housewives and farmers were the most affected. In our study, 72% of patients had unilateral spondylodesis and 28% had bilateral fusion. Preoperatively, 71% of patients had insurmountable pain, refractory to medical treatment. At 3 months postoperatively, 73.7% of patients with bilateral setup had moderate pain compared to 69% of those with unilateral setup. At 6 months postoperatively, 79% of patients with bilateral fusion had mild pain compared to 82% of patients with unilateral setup. At 1 year postoperatively, all patients had mild pain. Preoperatively, 66.2% of patients were unable to walk and 19.1% of patients were bedridden according to the Oswestry score. At 3 months postoperatively, 10.2% of patients with unilateral setup were unable to walk compared to 10.5% of patients with bilateral fixation, while 67.3% of patients with unilateral fixation had moderate disability compared to 52.6% of patients with bilateral fixation. At 6 months postoperatively, 51% of patients with unilateral setup had moderate disability compared to 47.4% of patients with bilateral fixation, while 42.9% of patients with unilateral fixation had mild disability compared to 42.1% of patients with bilateral fixation. At 1 year postoperatively, 81.6% of patients who underwent unilateral fixation had only mild disability compared to 73.7% of patients with bilateral fixation. Conclusion: The assessment of quality of life according to the set-up used shows similar results at 3 months, 6 months and 1 year, with no statistically significant differences. Single-sided pedicle screw fixation combined with transforaminal lumbar interbody fusion or mounting has the advantage of being faster, with less bleeding and is less expensive compared to bilateral fixation.展开更多
Objective:Validation is an important aspect of an instrument,and it ensures the confidence of researchers to employ the instrument in their studies.This study was conducted to develop and validate an instrument to ass...Objective:Validation is an important aspect of an instrument,and it ensures the confidence of researchers to employ the instrument in their studies.This study was conducted to develop and validate an instrument to assess knowledge,attitudes,and practices(KAP) on digital health among nurses since digital health capacity is a major concern in health care that needs to be assessed.Methods:We conducted a methodological study to assess the content validity and reliability of the instrument.First,items were generated through a comprehensive literature review and by obtaining an expert opinion.Second,content and face validity were assessed by a panel of 7 experts.Both the item-level content validity index(I-CVI) and the scale-level content validity index(S-CVI) were established.Moreover,test–retest reliability and internal consistency of the instrument were assessed.Data were analyzed using SPSS version 25.Results:The initial pool consisted of 60 items and after obtaining content,face,and construct validity,51 items remained.Items with an I-CVI <0.78 were considered relevant.The S-CVI for relevancy,clarity,ambiguity,and simplicity were 0.93,0.91,0.94,and 0.92,respectively.Five subcomponents were constructed in each knowledge and attitudes domain,and the test–retest reliability test revealed that the instrument has good reliability,showing correlation coefficient values for the KAP domains and the total questionnaire of 0.76,0.98,0.99,and 0.99,respectively.The independent Cronbach's α for all items was 0.76,indicating good internal consistency.Conclusions:The present study established the acceptable validity and ensured the good reliability and internal consistency of the instrument,which can serve as an assessment tool of KAP on digital health among healthcare professionals.展开更多
This work is carried out based on the analysis of urban planning instruments,taking the gender perspective as a foundation.It arises from the inclusion of women in the participation of urban development,through an ana...This work is carried out based on the analysis of urban planning instruments,taking the gender perspective as a foundation.It arises from the inclusion of women in the participation of urban development,through an analysis of the gender gaps that have marked the history of women,the inequalities serve as a basis for carrying out this study.It highlights the challenges we face today as a society in the process of building citizen participation,where we must all be recognized and have equal opportunities within the territory in which we live.This article analyzes the extent to which the Municipal Urban Development Programs of the Mexican municipality of Comala,Colima,Mexico,consider the recommendations on gender and urbanism,established since the 1990s by international entities and applied transversally to urban planning policies.Considerable differences are found between women and men in terms of empowerment and participation in urban territorial planning instruments,mainly in the oldest instrument(1997).Significant progress is observed in the most recent document and is currently in force in the municipality of Comala(2009).展开更多
This article explores the topic of fault diagnosis and maintenance strategies for instrument automation control systems,analyzing them through specific cases.The aim of this research is to improve the stability and re...This article explores the topic of fault diagnosis and maintenance strategies for instrument automation control systems,analyzing them through specific cases.The aim of this research is to improve the stability and reliability of the system by conducting a thorough investigation of faults and maintenance in instrument automation control systems.By doing so,this research hopes to provide a strong guarantee for the smooth progress of industrial production.展开更多
To improve the reliability of the light emitting diode(LED)signal lamp filament current monitoring alarm instrument for metro systems,a new type of hot standby online monitoring apparatus was developed which is based ...To improve the reliability of the light emitting diode(LED)signal lamp filament current monitoring alarm instrument for metro systems,a new type of hot standby online monitoring apparatus was developed which is based on synchronous transmission data(STD)bus technology.In this system,a double hot standby mode can be achieved by adopting bus arbitration.In addition,to detect the effective value of alternating current which is from 0 to 200 mA in the signal lamp lighting circuit,a precision rectifier signal conditioning circuit and an isolated acquisition circuit were designed.This new type of alarm instrument has high detection accuracy and could meet the functional requirements for metro signal systems after comparing it with some industry products that were applied on the spot.展开更多
As one of the most important key technologies for future advanced light source based on the energy recovery linac, a photocathode dc electron gun is supported by Institute of High Energy Physics (IHEP) to address th...As one of the most important key technologies for future advanced light source based on the energy recovery linac, a photocathode dc electron gun is supported by Institute of High Energy Physics (IHEP) to address the technical challenges of producing very low ernittance beams at high average current. Construction of the dc gun is completed and a preliminary high voltage conditioning is carried out up to 440 k V. The design, construction and preliminary HV conditioning results for the dc gun are described.展开更多
We investigate the dc Josephson effect in one-dimensional junctions where a ring conductor is sandwiched between two semiconductor nanowires with proximity-induced superconductivity. Peculiar features of the Josephson...We investigate the dc Josephson effect in one-dimensional junctions where a ring conductor is sandwiched between two semiconductor nanowires with proximity-induced superconductivity. Peculiar features of the Josephson effect arise due to the interplay of spin-orbit interaction and external Zeenmn field. By tuning the Zeeman field orientation, the device can vary from 0 to π junction. Afore importantly, nonzero ,losephson current is possible at zero phase difference across the junction. Although this anomalous Josephson current is not relevant to the topological phase transition, its magnitude can be significantly enhanced whe, n the nanowire, s become topological superconductors where Majorana bound states emerge. Distinct modulation patterns are obtained for the semiconductor nanowires in the topologically trivial and non-trivial phases. These results are useful to probe the topological phase transition in semiconductor nanowire junctions via the dc Josephson effect.展开更多
A self-consistent model was adopted to study the time evolution of low-voltage pulsed DC glow discharge. The distributions of electric field, ion density and electron density in nitrogen were investigated in our simul...A self-consistent model was adopted to study the time evolution of low-voltage pulsed DC glow discharge. The distributions of electric field, ion density and electron density in nitrogen were investigated in our simulation, and the temporal shape of the discharge current was also obtained. Our results show that the dynamic behaviors of the discharge depends strongly on the applied pulse voltage, and the use of higher pulse voltages results in a significantly increase of discharge current and a decrease of discharge delay time. The current-voltage characteristic cMculated by adjusting secondary electron emission coefficient for different applied pulse voltage under the gas pressure of 1 Torr is found in a reasonable agreement with the experimental results.展开更多
BACKGROUND Diabetic sensorimotor polyneuropathy is an important risk factor for foot ulceration and amputation.Thus,patients with diabetes should be screened for this disorder according to local guidelines.An obstacle...BACKGROUND Diabetic sensorimotor polyneuropathy is an important risk factor for foot ulceration and amputation.Thus,patients with diabetes should be screened for this disorder according to local guidelines.An obstacle to the diagnosis of this disease may be the lack of unified diagnostic criteria due to the lack of properly validated scales used for assessment.AIM To validate both sections(A and B)of the Michigan Neuropathy Screening Instrument(MNSI)in Polish(PL)patients with diabetes.METHODS A cross-sectional study using a test(A1,B1)and re-test(A2,B2)formula was performed in 80 patients with diabetes.The gold standard used for neuropathy detection was a nerve conduction study(NCS)which was performed in all participants.Reliability of the MNSI-PL was assessed using the Cronbach’s alpha,Kuder-Richardson formula 20(KR-20),split-half reliability,the Gottman split-half tests,and correlation between first and second half was accessed.Stability was assessed using an intraclass correlation coefficient(ICC).For external validation,we used simple linear correlation,binomial regression,and agreement between two different tools using a Bland-Altman plot analysis.RESULTS The scale was internally consistent(Cronbach’s alpha for the full scale:0.81 for A and 0.87 for B).MNSI-PL scores in test/retest showed high stability(ICC=0.73 for A and ICC=0.97 for B).The statistically important correlations between MNSI-PL and NCS were found for B1,B2,and A1(P<0.005).The cut-off points of≥3 for section A(sensitivity of 90%-100%;specificity of 33%-40%)and≥2 for section B(sensitivity of 81%-84%;specificity of 60%-70%)were obtained during neuropathy detection.CONCLUSION The MNSI-PL is a reliable and valid instrument in screening for diabetic neuropathy.展开更多
This paper reports that a series of silver oxide (AgzO) films are deposited on glass substrates by direct-current reactive magnetron sputtering at a substrate temperature of 250 ℃ and an oxygen flux ratio of 15:18...This paper reports that a series of silver oxide (AgzO) films are deposited on glass substrates by direct-current reactive magnetron sputtering at a substrate temperature of 250 ℃ and an oxygen flux ratio of 15:18 by modifying the sputtering power (SP). The AgxO films deposited apparently show a structural evolution from cubic biphased (AgO + Ag20) to cubic single-phased (Ag20), and to biphased (Ag20 + AgO) structure. Notably, the cubic single-phased Ag20 fihn is deposited at the SP = 105 W and an AgO phase with (220) orientation discerned in the Ag^O films deposited using the SP 〉 105 W. The transmissivity and refiectivity of the AgxO films in transparent region decrease with the increase the SP, whereas the absorptivity inversely increases with the increase of the SP. These results may be due to the structural evolution and the increasing film thickness. A redshift of the films' absorption edges determined in terms of Tauc formula clearly occurs from 3.1 eV to 2.73 eV with the increase of the SP.展开更多
BACKGROUND Over the past years,patient specific instrumentation(PSI)for total knee arthroplasty(TKA)has been implemented and routinely used.No clear answer has been given on its associated cost and cost-effectiveness ...BACKGROUND Over the past years,patient specific instrumentation(PSI)for total knee arthroplasty(TKA)has been implemented and routinely used.No clear answer has been given on its associated cost and cost-effectiveness when compared to conventional instrumentation(CI)for TKA.AIM To compare the cost and cost-effectiveness of PSI TKA compared to CI TKA.METHODS A literature search was performed in healthcare,economical healthcare,and medical databases(MEDLINE,EMBASE,CINAHL,Web of Science,Cochrane Library,EconLit).It was conducted in April 2021 and again in January 2022.Relevant literature included randomised controlled trials,retrospective studies,prospective studies,observational studies,and case control studies.All studies were assessed on methodological quality.Relevant outcomes included incremental cost-effectiveness ratio,quality-adjusted life years,total costs,imaging costs,production costs,sterilization associated costs,surgery duration costs and readmission rate costs.All eligible studies were assessed for risk of bias.Meta-analysis was performed for outcomes with sufficient data.RESULTS Thirty-two studies were included into the systematic review.Two were included in the metaanalysis.3994 PSI TKAs and 13267 CI TKAs were included in the sample size.The methodological quality of the included studies,based on Consensus on Health Economic Criteria-scores and risk of bias,ranged from average to good.PSI TKA costs less than CI TKA when considering mean operating room time and its associated costs and tray sterilization per patient case.PSI TKA costs more compared to CI TKA when considering imaging and production costs.Considering total costs per patient case,PSI TKA is more expensive in comparison to CI TKA.Meta-analysis comparing total costs for PSI TKA,and CI TKA showed a significant higher cost for PSI TKA.CONCLUSION Cost for PSI and CI TKA can differ when considering distinct aspects of their implementation.Total costs per patient case are increased for PSI TKA when compared to CI TKA.展开更多
Corona discharge suppression for high-voltage direct-current(HVDC)transmission lines at line terminals such as converter stations is a subject that requires attention.In this paper,a method based on a conductor covere...Corona discharge suppression for high-voltage direct-current(HVDC)transmission lines at line terminals such as converter stations is a subject that requires attention.In this paper,a method based on a conductor covered with dielectric film is proposed and implemented through a bench-scale setup.Compared with the bare conductor,the corona discharge suppression effect of the dielectric-film-covered conductor under positive polarity is studied from the composite field strength and ion current density using a line-plate experimental device.The influences of film thickness and film material on the corona discharge suppression effect are investigated.The charge accumulation and dissipation characteristics of different film materials are also studied.The results show that the conductor covered with dielectric film has excellent ability to inhibit corona discharge.The ground-level composite field strength of the conductor covered with dielectric film is lower than its nominal field strength,and its ion current density is at the nA m^(−2) level.The corona threshold voltage can be promoted by increasing the film thickness,but the ability to inhibit corona discharge becomes weak.The larger the surface electric field strength,the more charge accumulated,but the faster the charge dissipation rate.Compared with polyvinyl chloride film,cross-linked polyethylene film has stronger charge accumulation ability and slower charge dissipation rate,which can better restrain the corona discharge of HVDC transmission lines.展开更多
With the help of surgical navigation system,doctors can operate on patients more intuitively and accurately.The positioning accuracy and real-time performance of surgical instruments are very important to the whole sy...With the help of surgical navigation system,doctors can operate on patients more intuitively and accurately.The positioning accuracy and real-time performance of surgical instruments are very important to the whole system.In this paper,we analyze and design the detection algorithm of surgical instrument location mark,and estimate the posture of surgical instrument.In addition,we optimized the pose by remapping.Finally,the algorithm of location mark detection proposed in this paper and the posture analysis data of surgical instruments are verified and analyzed through experiments.The final result shows a high accuracy.展开更多
Zinc oxide (ZnO) is one of the most promising and frequently used semiconductor materials. In-doped nanos- tructure ZnO thin films are grown on p-type gallium nitride substrates by employing the simultaneous rf and ...Zinc oxide (ZnO) is one of the most promising and frequently used semiconductor materials. In-doped nanos- tructure ZnO thin films are grown on p-type gallium nitride substrates by employing the simultaneous rf and dc magnetron co-sputtering technique. The effect of In-doping on structural, morphological and electrical properties is studied. The different dopant concentrations are accomplished by varying the direct current power of the In target while keeping the fixed radio frequency power of the ZnO target through the co-sputtering deposition technique by using argon as the sputtering gas at ambient temperature. The structural analysis confirms that all the grown thin films preferentially orientate along the c-axis with the wurtzite hexagonal crystal structure without having any kind of In oxide phases. The presenting Zn, 0 and In elements' chemical compositions are identified with EDX mapping analysis of the deposited thin films and the calculated M ratio has been found to decrease with the increasing In power. The surface topographies of the grown thin films are examined with the atomic force microscope technique. The obtained results reveal that the grown film roughness increases with the In power. The Hall measurements ascertain that all the grown films have n-type conductivity and also the other electrical parameters such as resistivity,mobility and carrier concentration are analyzed.展开更多
Journal of Measurement Science and Iustrumentation(CN14-1357/TH,ISSN 1674-8042)is published by North University of China.It is a comprehensive academic journal,aiming to present scientifie research papers in the field...Journal of Measurement Science and Iustrumentation(CN14-1357/TH,ISSN 1674-8042)is published by North University of China.It is a comprehensive academic journal,aiming to present scientifie research papers in the fields of measurement science and instrumentation,ineluding general and instrumentation of measurement and control applied to such academie and industrial fields asprineiples.展开更多
基金This work was supported by the National Research Foundation of Korea(NRF)grant funded by the Korea government(MSIT)(No.2022R1C1C1008831).This work was also supported by the Human Resources Development of the Korea Institute of Energy Technology Evaluation and Planning(KETEP)grant funded by the Ministry of Trade,Industry and Energy of Korea(No.RS-2023-00244330).S J P was supported by Basic Research Program through the National Research Foundation of Korea(NRF)funded by the Ministry of Education(No.2018R1A6A1A03025526).
文摘Amid the growing interest in triboelectric nanogenerators(TENGs)as novel energy-harvesting devices,several studies have focused on direct current(DC)TENGs to generate a stable DC output for operating electronic devices.However,owing to the working mechanisms of conventional DC TENGs,generating a stable DC output from reciprocating motion remains a challenge.Accordingly,we propose a bidirectional rotating DC TENG(BiR-TENG),which can generate DC outputs,regardless of the direction of rotation,from reciprocating motions.The distinct design of the BiR-TENG enables the mechanical rectification of the alternating current output into a rotational-direction-dependent DC output.Furthermore,it allows the conversion of the rotational-direction-dependent DC output into a unidirectional DC output by adapting the configurations depending on the rotational direction.Owing to these tailored design strategies and subsequent optimizations,the BiR-TENG could generate an effective unidirectional DC output.Applications of the BiR-TENG for the reciprocating motions of swinging doors and waves were demonstrated by harnessing this output.This study demonstrates the potential of the BiR-TENG design strategy as an effective and versatile solution for energy harvesting from reciprocating motions,highlighting the suitability of DC outputs as an energy source for electronic devices.
基金supported by National Natural Science Foundation of China (No. 12075132)。
文摘The key plasma parameters under different discharge modes, such as heavy-particle and electron temperatures, electron number density, and nonequilibrium volume of plasmas, play important roles in various applications of gas discharge plasmas. In this study, a self-consistent two-dimensional nonequilibrium fluid model coupled with an external circuit model is established to reveal the mechanisms related to the discharge modes, including the normal glow, abnormal glow,arc, and glow-to-arc transition modes, with an atmospheric-pressure direct-current(DC) argon discharge as a model plasma system. The modeling results show that, under different discharge modes, the most significant difference between the preceding four discharge modes lies in the current and energy transfer processes on the cathode side. On one hand, the current to the cathode surface is mainly delivered by the ions coming from the plasma column under the glow discharge mode due to the low temperature of the solid cathode, whereas the thermionic and secondary electrons emitted from the hot cathode surface play a very important role under the arc mode with a higher cathode surface temperature and higher ion flux toward the cathode. On the other hand, the energy transfer channel on the cathode side changes from mainly heating the solid cathode under the glow mode to simultaneously heating both the solid cathode and plasma column under the arc mode with an increase in the discharge current. Consequently, the power density in the cathode sheath(P_c) was used as a key parameter for judging different discharge modes, and the range of(0.28–1.2) × 10^(12) W m^(-3) was determined as a critical window of P_c corresponding to the glow-to-arc-mode transition for the atmospheric-pressure DC argon discharge, which was also verified by comparison with the experimental results in this study and the data in the previous literature.
文摘The ESA and CAS SMILE mission orbit is highly elliptical and will pass through multiple radiation environments.The Soft X-ray Imager(SXI)instrument aboard has a radiation shutter door designed to close when the surrounding radiation flux is high.The shutter door will close when passing below an altitude threshold to protect against trapped particles in the Earth’s Van Allen Belts.Therefore,two radiation environments can be approximated based on the shutter door position:open and closed.The instrument background for the CCDs(Charge-Coupled Devices)that form the focal plane array of the SXI were evaluated for the two environments.Due to the correlation of the space environment with the solar cycle,the solar minima and maxima,the background was also evaluated at these two extremes.The results demonstrated that the highest instrument background will occur during solar minima due to the main contributing source being Galactic Cosmic Rays(GCRs).It was also found that the open background was highest for solar minima and that the closed background was highest during solar maxima.This is due to the radiation shutter door acting as a scattering centre and the changes in the energy flux distribution of the GCRs between the two solar extremes.
文摘Dear Readers:Astronomical Techniques and Instruments is a professional English journal of open access devoted to recent develop-ments,discoveries,and theories in astronomical techniques,methods,and instruments.It will serve as a platform for dis-course,learning,and information sharing for astronomic and astrophysics professionals worldwide.
基金Supported Biotechnology Application Demonstration Major in Hebei Province(20801001002)Provincial Biotechnology Application Demonstration Major(SYLZY2021-1)+2 种基金School-level Biotechnology Application Demonstration Major(XYYZY2024-1)School-level Education and Teaching Reform Project of Langfang Normal University in 2022(K2022-22)Industry-University Cooperative Education Project of Ministry of Education(20210211904).
文摘Through the online and offline practical reform of the Modern Instrumental Analysis course of biotechnology majors from teaching content,teaching method,teaching demonstration to teaching effect,the traditional single offline lecture is transformed into diversified and interactive modern teaching.The practical reform enriches and optimizes the course content,perfects and improves the course assessment system,and improves the teaching quality.It achieves the student-centered and application-oriented teaching goal,and also provides reference for further cultivating high-quality applied talents.
文摘Introduction: The choice of adopting unilateral pedicle screw fixation or using bilateral pedicle screw fixation in lumbar spinal stenosis remains controversial. In our context, very few studies have been performed comparing the clinical effectiveness of unilateral versus bilateral fixation in the surgical management of lumbar spinal canal stenosis. Objective: Evaluate the impact on quality of life and clinical efficacy of unilateral spondylodesis compared to bilateral spondylodesis in the surgical management of lumbar spinal canal stenosis at the Yaounde Central Hospital. Methods: This was a retrospective descriptive cross-sectional study for a period of 4 years, from June 2015 to June 2019. It involved all patients operated for lumbar canal stenosis and who underwent spondylodesis or spinal fusion at the neurosurgery department of the Yaounde Central Hospital. Results: A total of 68 participants were recruited during our study period. 32 (47%) of the study population were in the 50 - 60 age group, with a mean age of 56.98 years ranging from 41 to 75 years. Females, housewives and farmers were the most affected. In our study, 72% of patients had unilateral spondylodesis and 28% had bilateral fusion. Preoperatively, 71% of patients had insurmountable pain, refractory to medical treatment. At 3 months postoperatively, 73.7% of patients with bilateral setup had moderate pain compared to 69% of those with unilateral setup. At 6 months postoperatively, 79% of patients with bilateral fusion had mild pain compared to 82% of patients with unilateral setup. At 1 year postoperatively, all patients had mild pain. Preoperatively, 66.2% of patients were unable to walk and 19.1% of patients were bedridden according to the Oswestry score. At 3 months postoperatively, 10.2% of patients with unilateral setup were unable to walk compared to 10.5% of patients with bilateral fixation, while 67.3% of patients with unilateral fixation had moderate disability compared to 52.6% of patients with bilateral fixation. At 6 months postoperatively, 51% of patients with unilateral setup had moderate disability compared to 47.4% of patients with bilateral fixation, while 42.9% of patients with unilateral fixation had mild disability compared to 42.1% of patients with bilateral fixation. At 1 year postoperatively, 81.6% of patients who underwent unilateral fixation had only mild disability compared to 73.7% of patients with bilateral fixation. Conclusion: The assessment of quality of life according to the set-up used shows similar results at 3 months, 6 months and 1 year, with no statistically significant differences. Single-sided pedicle screw fixation combined with transforaminal lumbar interbody fusion or mounting has the advantage of being faster, with less bleeding and is less expensive compared to bilateral fixation.
基金supported by the University of Sri Jayewardenepura(No. ASP/01/RE/AHS/2021/91)。
文摘Objective:Validation is an important aspect of an instrument,and it ensures the confidence of researchers to employ the instrument in their studies.This study was conducted to develop and validate an instrument to assess knowledge,attitudes,and practices(KAP) on digital health among nurses since digital health capacity is a major concern in health care that needs to be assessed.Methods:We conducted a methodological study to assess the content validity and reliability of the instrument.First,items were generated through a comprehensive literature review and by obtaining an expert opinion.Second,content and face validity were assessed by a panel of 7 experts.Both the item-level content validity index(I-CVI) and the scale-level content validity index(S-CVI) were established.Moreover,test–retest reliability and internal consistency of the instrument were assessed.Data were analyzed using SPSS version 25.Results:The initial pool consisted of 60 items and after obtaining content,face,and construct validity,51 items remained.Items with an I-CVI <0.78 were considered relevant.The S-CVI for relevancy,clarity,ambiguity,and simplicity were 0.93,0.91,0.94,and 0.92,respectively.Five subcomponents were constructed in each knowledge and attitudes domain,and the test–retest reliability test revealed that the instrument has good reliability,showing correlation coefficient values for the KAP domains and the total questionnaire of 0.76,0.98,0.99,and 0.99,respectively.The independent Cronbach's α for all items was 0.76,indicating good internal consistency.Conclusions:The present study established the acceptable validity and ensured the good reliability and internal consistency of the instrument,which can serve as an assessment tool of KAP on digital health among healthcare professionals.
文摘This work is carried out based on the analysis of urban planning instruments,taking the gender perspective as a foundation.It arises from the inclusion of women in the participation of urban development,through an analysis of the gender gaps that have marked the history of women,the inequalities serve as a basis for carrying out this study.It highlights the challenges we face today as a society in the process of building citizen participation,where we must all be recognized and have equal opportunities within the territory in which we live.This article analyzes the extent to which the Municipal Urban Development Programs of the Mexican municipality of Comala,Colima,Mexico,consider the recommendations on gender and urbanism,established since the 1990s by international entities and applied transversally to urban planning policies.Considerable differences are found between women and men in terms of empowerment and participation in urban territorial planning instruments,mainly in the oldest instrument(1997).Significant progress is observed in the most recent document and is currently in force in the municipality of Comala(2009).
文摘This article explores the topic of fault diagnosis and maintenance strategies for instrument automation control systems,analyzing them through specific cases.The aim of this research is to improve the stability and reliability of the system by conducting a thorough investigation of faults and maintenance in instrument automation control systems.By doing so,this research hopes to provide a strong guarantee for the smooth progress of industrial production.
文摘To improve the reliability of the light emitting diode(LED)signal lamp filament current monitoring alarm instrument for metro systems,a new type of hot standby online monitoring apparatus was developed which is based on synchronous transmission data(STD)bus technology.In this system,a double hot standby mode can be achieved by adopting bus arbitration.In addition,to detect the effective value of alternating current which is from 0 to 200 mA in the signal lamp lighting circuit,a precision rectifier signal conditioning circuit and an isolated acquisition circuit were designed.This new type of alarm instrument has high detection accuracy and could meet the functional requirements for metro signal systems after comparing it with some industry products that were applied on the spot.
基金Supported by the Innovation and Technology Fund of Institute of High Energy Physics
文摘As one of the most important key technologies for future advanced light source based on the energy recovery linac, a photocathode dc electron gun is supported by Institute of High Energy Physics (IHEP) to address the technical challenges of producing very low ernittance beams at high average current. Construction of the dc gun is completed and a preliminary high voltage conditioning is carried out up to 440 k V. The design, construction and preliminary HV conditioning results for the dc gun are described.
基金Supported by the Fundamental Research Funds for the Central Universities under Grant No 15D210901the National Natural Science Foundation of China under Grant Nos 11174049 and 61290301the National University Student Innovation Program under Grant No 14T10902
文摘We investigate the dc Josephson effect in one-dimensional junctions where a ring conductor is sandwiched between two semiconductor nanowires with proximity-induced superconductivity. Peculiar features of the Josephson effect arise due to the interplay of spin-orbit interaction and external Zeenmn field. By tuning the Zeeman field orientation, the device can vary from 0 to π junction. Afore importantly, nonzero ,losephson current is possible at zero phase difference across the junction. Although this anomalous Josephson current is not relevant to the topological phase transition, its magnitude can be significantly enhanced whe, n the nanowire, s become topological superconductors where Majorana bound states emerge. Distinct modulation patterns are obtained for the semiconductor nanowires in the topologically trivial and non-trivial phases. These results are useful to probe the topological phase transition in semiconductor nanowire junctions via the dc Josephson effect.
基金supported by the Program for Innovative Research Team of High Education in Liaoning province of China (No.2009T055)
文摘A self-consistent model was adopted to study the time evolution of low-voltage pulsed DC glow discharge. The distributions of electric field, ion density and electron density in nitrogen were investigated in our simulation, and the temporal shape of the discharge current was also obtained. Our results show that the dynamic behaviors of the discharge depends strongly on the applied pulse voltage, and the use of higher pulse voltages results in a significantly increase of discharge current and a decrease of discharge delay time. The current-voltage characteristic cMculated by adjusting secondary electron emission coefficient for different applied pulse voltage under the gas pressure of 1 Torr is found in a reasonable agreement with the experimental results.
基金Supported by the Ministry of Health Subvention from the IT Simple System of the Wroclaw Medical University by Wroclaw Medical University,No.SUBZ.C310.22.075the MCDTR grant from the National Institute of Diabetes and Digestive and Kidney Diseases,No.P30DK092926.
文摘BACKGROUND Diabetic sensorimotor polyneuropathy is an important risk factor for foot ulceration and amputation.Thus,patients with diabetes should be screened for this disorder according to local guidelines.An obstacle to the diagnosis of this disease may be the lack of unified diagnostic criteria due to the lack of properly validated scales used for assessment.AIM To validate both sections(A and B)of the Michigan Neuropathy Screening Instrument(MNSI)in Polish(PL)patients with diabetes.METHODS A cross-sectional study using a test(A1,B1)and re-test(A2,B2)formula was performed in 80 patients with diabetes.The gold standard used for neuropathy detection was a nerve conduction study(NCS)which was performed in all participants.Reliability of the MNSI-PL was assessed using the Cronbach’s alpha,Kuder-Richardson formula 20(KR-20),split-half reliability,the Gottman split-half tests,and correlation between first and second half was accessed.Stability was assessed using an intraclass correlation coefficient(ICC).For external validation,we used simple linear correlation,binomial regression,and agreement between two different tools using a Bland-Altman plot analysis.RESULTS The scale was internally consistent(Cronbach’s alpha for the full scale:0.81 for A and 0.87 for B).MNSI-PL scores in test/retest showed high stability(ICC=0.73 for A and ICC=0.97 for B).The statistically important correlations between MNSI-PL and NCS were found for B1,B2,and A1(P<0.005).The cut-off points of≥3 for section A(sensitivity of 90%-100%;specificity of 33%-40%)and≥2 for section B(sensitivity of 81%-84%;specificity of 60%-70%)were obtained during neuropathy detection.CONCLUSION The MNSI-PL is a reliable and valid instrument in screening for diabetic neuropathy.
基金supported by the National Natural Science Foundation of China (Grant No. 60807001)the National Basic Research Program of China (Grant No. 2011CB201605)the Foundation of Henan Educational Committee (Grant No. 2010A140017)
文摘This paper reports that a series of silver oxide (AgzO) films are deposited on glass substrates by direct-current reactive magnetron sputtering at a substrate temperature of 250 ℃ and an oxygen flux ratio of 15:18 by modifying the sputtering power (SP). The AgxO films deposited apparently show a structural evolution from cubic biphased (AgO + Ag20) to cubic single-phased (Ag20), and to biphased (Ag20 + AgO) structure. Notably, the cubic single-phased Ag20 fihn is deposited at the SP = 105 W and an AgO phase with (220) orientation discerned in the Ag^O films deposited using the SP 〉 105 W. The transmissivity and refiectivity of the AgxO films in transparent region decrease with the increase the SP, whereas the absorptivity inversely increases with the increase of the SP. These results may be due to the structural evolution and the increasing film thickness. A redshift of the films' absorption edges determined in terms of Tauc formula clearly occurs from 3.1 eV to 2.73 eV with the increase of the SP.
文摘BACKGROUND Over the past years,patient specific instrumentation(PSI)for total knee arthroplasty(TKA)has been implemented and routinely used.No clear answer has been given on its associated cost and cost-effectiveness when compared to conventional instrumentation(CI)for TKA.AIM To compare the cost and cost-effectiveness of PSI TKA compared to CI TKA.METHODS A literature search was performed in healthcare,economical healthcare,and medical databases(MEDLINE,EMBASE,CINAHL,Web of Science,Cochrane Library,EconLit).It was conducted in April 2021 and again in January 2022.Relevant literature included randomised controlled trials,retrospective studies,prospective studies,observational studies,and case control studies.All studies were assessed on methodological quality.Relevant outcomes included incremental cost-effectiveness ratio,quality-adjusted life years,total costs,imaging costs,production costs,sterilization associated costs,surgery duration costs and readmission rate costs.All eligible studies were assessed for risk of bias.Meta-analysis was performed for outcomes with sufficient data.RESULTS Thirty-two studies were included into the systematic review.Two were included in the metaanalysis.3994 PSI TKAs and 13267 CI TKAs were included in the sample size.The methodological quality of the included studies,based on Consensus on Health Economic Criteria-scores and risk of bias,ranged from average to good.PSI TKA costs less than CI TKA when considering mean operating room time and its associated costs and tray sterilization per patient case.PSI TKA costs more compared to CI TKA when considering imaging and production costs.Considering total costs per patient case,PSI TKA is more expensive in comparison to CI TKA.Meta-analysis comparing total costs for PSI TKA,and CI TKA showed a significant higher cost for PSI TKA.CONCLUSION Cost for PSI and CI TKA can differ when considering distinct aspects of their implementation.Total costs per patient case are increased for PSI TKA when compared to CI TKA.
基金by State Grid Shandong Electric Power Company(52062618001M)。
文摘Corona discharge suppression for high-voltage direct-current(HVDC)transmission lines at line terminals such as converter stations is a subject that requires attention.In this paper,a method based on a conductor covered with dielectric film is proposed and implemented through a bench-scale setup.Compared with the bare conductor,the corona discharge suppression effect of the dielectric-film-covered conductor under positive polarity is studied from the composite field strength and ion current density using a line-plate experimental device.The influences of film thickness and film material on the corona discharge suppression effect are investigated.The charge accumulation and dissipation characteristics of different film materials are also studied.The results show that the conductor covered with dielectric film has excellent ability to inhibit corona discharge.The ground-level composite field strength of the conductor covered with dielectric film is lower than its nominal field strength,and its ion current density is at the nA m^(−2) level.The corona threshold voltage can be promoted by increasing the film thickness,but the ability to inhibit corona discharge becomes weak.The larger the surface electric field strength,the more charge accumulated,but the faster the charge dissipation rate.Compared with polyvinyl chloride film,cross-linked polyethylene film has stronger charge accumulation ability and slower charge dissipation rate,which can better restrain the corona discharge of HVDC transmission lines.
基金supported by the Sichuan Science and Technology Program(2021YFQ0003).
文摘With the help of surgical navigation system,doctors can operate on patients more intuitively and accurately.The positioning accuracy and real-time performance of surgical instruments are very important to the whole system.In this paper,we analyze and design the detection algorithm of surgical instrument location mark,and estimate the posture of surgical instrument.In addition,we optimized the pose by remapping.Finally,the algorithm of location mark detection proposed in this paper and the posture analysis data of surgical instruments are verified and analyzed through experiments.The final result shows a high accuracy.
基金Supported by the RU Top-Down under Grant No 1001/CSS/870019
文摘Zinc oxide (ZnO) is one of the most promising and frequently used semiconductor materials. In-doped nanos- tructure ZnO thin films are grown on p-type gallium nitride substrates by employing the simultaneous rf and dc magnetron co-sputtering technique. The effect of In-doping on structural, morphological and electrical properties is studied. The different dopant concentrations are accomplished by varying the direct current power of the In target while keeping the fixed radio frequency power of the ZnO target through the co-sputtering deposition technique by using argon as the sputtering gas at ambient temperature. The structural analysis confirms that all the grown thin films preferentially orientate along the c-axis with the wurtzite hexagonal crystal structure without having any kind of In oxide phases. The presenting Zn, 0 and In elements' chemical compositions are identified with EDX mapping analysis of the deposited thin films and the calculated M ratio has been found to decrease with the increasing In power. The surface topographies of the grown thin films are examined with the atomic force microscope technique. The obtained results reveal that the grown film roughness increases with the In power. The Hall measurements ascertain that all the grown films have n-type conductivity and also the other electrical parameters such as resistivity,mobility and carrier concentration are analyzed.
文摘Journal of Measurement Science and Iustrumentation(CN14-1357/TH,ISSN 1674-8042)is published by North University of China.It is a comprehensive academic journal,aiming to present scientifie research papers in the fields of measurement science and instrumentation,ineluding general and instrumentation of measurement and control applied to such academie and industrial fields asprineiples.