This work reports that the intensity ratio of spectral lines having similar self-absorption characteristics during laser induced breakdown spectroscopy(LIBS) analysis can become nearly constant over a wide range of ir...This work reports that the intensity ratio of spectral lines having similar self-absorption characteristics during laser induced breakdown spectroscopy(LIBS) analysis can become nearly constant over a wide range of irradiation conditions if the intensities are integrated over a sufficiently long time. It is shown that the plasma temperature and intensity ratio of these spectral lines have temporal similarity. The spectral lines with similar self-absorption properties may be selected to improve the accuracy and consistency of LIBS analysis results under an environment with fluctuating measurement conditions.展开更多
A new method for quantitative phase analysis is proposed by using X-ray diffraction multi-peak match intensity ratio. This method can obtain the multi-peak match intensity ratio among each phase in the mixture sample ...A new method for quantitative phase analysis is proposed by using X-ray diffraction multi-peak match intensity ratio. This method can obtain the multi-peak match intensity ratio among each phase in the mixture sample by using all diffraction peak data in the mixture sample X-ray diffraction spectrum and combining the relative intensity distribution data of each phase standard peak in JCPDS card to carry on the least square method regression analysis. It is benefit to improve the precision of quantitative phase analysis that the given single line ratio which is usually adopted is taken the place of the multi-peak match intensity ratio and is used in X-ray diffraction quantitative phase analysis of the mixture sample. By analyzing four-group mixture sample, adopting multi-peak match intensity ratio and X-ray diffraction quantitative phase analysis principle of combining the adiabatic and matrix flushing method, it is tested that the experimental results are identical with theory.展开更多
The vibration reduction characteristics of composite beams filled with magnetorheological elastomer core are studied experimentally.The fiber metal laminates with magnetorheological elastomers core is self-designed an...The vibration reduction characteristics of composite beams filled with magnetorheological elastomer core are studied experimentally.The fiber metal laminates with magnetorheological elastomers core is self-designed and prepared.Internal magnetic field is applied to the beam to explore its action of damping vibration performance under the magnetic field for the first time.The composite elements test system with controllable magnetic field intensity is designed and the function of each part is introduced.Then,a set of reasonable and standard vibration test flow of this type of composite beam under different magnetic field intensity is clarified,and the practical test is conducted.It has been found that the composite beam has excellent damping performance with the first 4 damping ratios being greater than 10%.Moreover,after the magnetic field is applied,its damping results can be further improved to meet the active control purpose.展开更多
Kr L X-ray and Au M X-ray emission for Kr13+ ions with energies of 1.5 MeV and 3.9 MeV impacting on an Au target are investigated at heavy ion research facility in Lanzhou (HIRFL). The L-shell X-ray yield per ion o...Kr L X-ray and Au M X-ray emission for Kr13+ ions with energies of 1.5 MeV and 3.9 MeV impacting on an Au target are investigated at heavy ion research facility in Lanzhou (HIRFL). The L-shell X-ray yield per ion of Kr is measured as a function of incident energy. In addition, Kr L X-ray production cross section is extracted from the yield and compared with the result obtained from the classical binary-encounter approximation (BEA) model. Furthermore, the intensity ratio of the Au M/33 to Ma1 X-ray is investigated as a function of incident energy.展开更多
Spectra of KX-rays emitted from pure 3 dtransition metals and their oxide and sulfate compounds were measured using a single crystal wavelength dispersive X-ray spectroscopy(WDXRF).The measurements were performed usin...Spectra of KX-rays emitted from pure 3 dtransition metals and their oxide and sulfate compounds were measured using a single crystal wavelength dispersive X-ray spectroscopy(WDXRF).The measurements were performed using a ZSX-100 esequential spectrometer equipped with an RhX-ray tube operated.An accurate analytical representation of each line was obtained by a fit to a Lorentz function.The spectra were analyzed in order to examine the KX-ray peak parameters such as asymmetry index,peak energy and relative intensity ratios.The energy shifts and relative intensities weredetermined tobetter understand the chemical effect.展开更多
基金supported by the R&D Center for Valuable Recycling (Global-Top R&BD Program) of the Ministry of Environment (Project No. 2016002250003)
文摘This work reports that the intensity ratio of spectral lines having similar self-absorption characteristics during laser induced breakdown spectroscopy(LIBS) analysis can become nearly constant over a wide range of irradiation conditions if the intensities are integrated over a sufficiently long time. It is shown that the plasma temperature and intensity ratio of these spectral lines have temporal similarity. The spectral lines with similar self-absorption properties may be selected to improve the accuracy and consistency of LIBS analysis results under an environment with fluctuating measurement conditions.
文摘A new method for quantitative phase analysis is proposed by using X-ray diffraction multi-peak match intensity ratio. This method can obtain the multi-peak match intensity ratio among each phase in the mixture sample by using all diffraction peak data in the mixture sample X-ray diffraction spectrum and combining the relative intensity distribution data of each phase standard peak in JCPDS card to carry on the least square method regression analysis. It is benefit to improve the precision of quantitative phase analysis that the given single line ratio which is usually adopted is taken the place of the multi-peak match intensity ratio and is used in X-ray diffraction quantitative phase analysis of the mixture sample. By analyzing four-group mixture sample, adopting multi-peak match intensity ratio and X-ray diffraction quantitative phase analysis principle of combining the adiabatic and matrix flushing method, it is tested that the experimental results are identical with theory.
基金This study was supported by the National Natural Science Foundation of China(granted No.51505070)the Fundamental Research Funds for the Central Universities of China(granted No.N160313002,N160312001,N170302001,N180302004,N180703018,N180312012 and N180313006)the National Key Laboratory of Science and Technology on Advanced Composites in Special Environments,Harbin Institute of Technology(granted No.6142905192512).
文摘The vibration reduction characteristics of composite beams filled with magnetorheological elastomer core are studied experimentally.The fiber metal laminates with magnetorheological elastomers core is self-designed and prepared.Internal magnetic field is applied to the beam to explore its action of damping vibration performance under the magnetic field for the first time.The composite elements test system with controllable magnetic field intensity is designed and the function of each part is introduced.Then,a set of reasonable and standard vibration test flow of this type of composite beam under different magnetic field intensity is clarified,and the practical test is conducted.It has been found that the composite beam has excellent damping performance with the first 4 damping ratios being greater than 10%.Moreover,after the magnetic field is applied,its damping results can be further improved to meet the active control purpose.
基金Project supported by the National Natural Science Foundation of China (Grant Nos.11075135,11075192,and 11075125)the Scientific Research Foundation of the Education Department of Shaanxi Province,China (Grant No.2010JK895)the Special Foundation of Xianyang Normal University,China (Grant No.11XSYK308)
文摘Kr L X-ray and Au M X-ray emission for Kr13+ ions with energies of 1.5 MeV and 3.9 MeV impacting on an Au target are investigated at heavy ion research facility in Lanzhou (HIRFL). The L-shell X-ray yield per ion of Kr is measured as a function of incident energy. In addition, Kr L X-ray production cross section is extracted from the yield and compared with the result obtained from the classical binary-encounter approximation (BEA) model. Furthermore, the intensity ratio of the Au M/33 to Ma1 X-ray is investigated as a function of incident energy.
基金the Scientific and Technological Research Council of Turkey (TUBITAK), under the project No. 10GT045
文摘Spectra of KX-rays emitted from pure 3 dtransition metals and their oxide and sulfate compounds were measured using a single crystal wavelength dispersive X-ray spectroscopy(WDXRF).The measurements were performed using a ZSX-100 esequential spectrometer equipped with an RhX-ray tube operated.An accurate analytical representation of each line was obtained by a fit to a Lorentz function.The spectra were analyzed in order to examine the KX-ray peak parameters such as asymmetry index,peak energy and relative intensity ratios.The energy shifts and relative intensities weredetermined tobetter understand the chemical effect.