通过测量样品的磁化强度-温度曲线、电阻率-温度曲线及磁电阻-温度曲线.研究了 Dy 掺杂(0.00≤x≤0.30)对 La_(0.7-x)Dy_xSr_(0.3)MnO_3 体系磁电性质的影响.实验发现,随 Dy 掺杂量的增加,体系磁结构从长程铁磁有序向自旋团簇玻璃态、...通过测量样品的磁化强度-温度曲线、电阻率-温度曲线及磁电阻-温度曲线.研究了 Dy 掺杂(0.00≤x≤0.30)对 La_(0.7-x)Dy_xSr_(0.3)MnO_3 体系磁电性质的影响.实验发现,随 Dy 掺杂量的增加,体系磁结构从长程铁磁有序向自旋团簇玻璃态、反铁磁状态转变;x=0.20、0.30时的低温磁行为发生异常,电行为存在低温电阻率极小值现象.这些奇特现象不仅来源于掺杂引起的晶格效应,也来源于掺杂引起的额外磁性耦合.展开更多
AIM:to study the prevalence and patterns of hepatic abnormal perfusion(HAP)visible by magnetic resonance imaging(MRI)in acute pancreatitis(AP).METHODS:Enhanced abdominal MRI was performed on 51 patients with AP.these ...AIM:to study the prevalence and patterns of hepatic abnormal perfusion(HAP)visible by magnetic resonance imaging(MRI)in acute pancreatitis(AP).METHODS:Enhanced abdominal MRI was performed on 51 patients with AP.these patients were divided into two groups according to the MRI results:those with signs of gallstones,cholecystitis,common bile duct(CBD)stones or dilatation of the CBD on MRI and those without.the prevalence,shape and distribution of HAP in the two groups were analyzed and compared.the severity of AP was graded using the MR severity index(MRSI).the correlation between the MRSI and HAP was then analyzed.RESULTS:Of the 51 patients with AP,32(63%)showed at least one sign of gallbladder and CBD abnormalities on the MR images,while 19(37%)showed no sign of gallbladder or CBD abnormalities.Nineteen patients(37%)had HAP visible in the enhanced images,including strip-,wedge-or patch-shaped HAP distributed in the hepatic tissue adjacent to the gallbladder and left and right liver lobes.there were no significant differences in the prevalence of HAP(χ2=0.305,P=0.581>0.05)or HAP distribution in the liver(χ2=2.181,P=0.536>0.05)between patients with and without gallbladder and CBD abnormalities.there were no significant differences in the MRSI score between patients with and without HAP(t=0.559,P=0.552>0.05).HAP was not correlated with the MRSI score.CONCLUSION:HAP is common in patients with AP and appears strip-,patch-or wedge-shaped on MRI.HAP on MRI cannot be used to indicate the severity of AP.展开更多
Insomnia is one of the most frequently observed sleep disorders, affecting nearly 10% of the general population. It has multiple etiological factors. Recently, it has been reported that EEG abnormalities are associate...Insomnia is one of the most frequently observed sleep disorders, affecting nearly 10% of the general population. It has multiple etiological factors. Recently, it has been reported that EEG abnormalities are associated with insomnia in patients previously diagnosed as idiopathic insomniacs. In addition, transcranial magnetic stimulation (TMS) has shown to be effective in the treatment of disorders characterized by neural hyper-excitability. Method: In the present study, patients with insomnia and EEG abnormalities were submitted to slow repetitive trans-cranial magnetic stimulation, for 15 minutes daily during 10 days. Polysomnographic recordings were performed before and after TMS. Results: The results indicate that the presence of EEG abnormalities significantly decreased after TMS. In addition, most of the sleep parameters showed significant improvement. Conclusions: These data support the notion that TMS is a reliable therapeutic tool for patients affected with abnormalities linked to neuronal hyper-excitability.展开更多
Residual stresses in ferromagnetic material affect the direction and structure of domains and generate magnetic field abnormality on the surface. In the formation of stress induced magnetic field, the influence of geo...Residual stresses in ferromagnetic material affect the direction and structure of domains and generate magnetic field abnormality on the surface. In the formation of stress induced magnetic field, the influence of geomagnetic field is unclear. Residual stress specimen was produced by tight matching of a round ring and a peg. The magnetic fields of contrast specimens, which were produced in geomagnetic field or in shielding geomagnetic field, were inspected with 8 mm lift-off. The results show that mean amplitude of magnetic field of the specimen produced in geomagnetic field is 0.85% larger than that of specimen produced in shielding geomagnetic field. So the formation of stress induced magnetic field abnormality above the surface of inspected ferromagnetic material geomagnetic field gives little contribution.展开更多
Abstract In the four-anode device, the mirror magnetic field affects the characteristics of charged particles motion, so that the current-voltage relations of glow discharge are changed. Firstly, the discharge device ...Abstract In the four-anode device, the mirror magnetic field affects the characteristics of charged particles motion, so that the current-voltage relations of glow discharge are changed. Firstly, the discharge device is introduced, and the distribution of mirror magnetic field generated by the loops surrounding the discharge chamber is presented. Both the discharge current-voltage characteristics and the radial distributions of electron density are measured, respectively, with/without the magnetic field. When the discharge occurs in a 99.99% helium with a pressure ranging from 100 Pa to 800 Pa without magnetic field, the voltage, sustaining a certain abnormal glow discharge current, decreases with the increase in gas pressure. With a mirror magnetic field of certain intensity, the discharge voltage increases with the current in a rate slower than that without the magnetic field. Moreover, when the magnetic field intensity increases, the discharge voltage first decreases then increases. Simultaneously, the mirror magnetic field affects the moving characteristics of charged particles, and causes a more inhomogeneous electron density.展开更多
The abnormal growth of grains of sintering Nd13.6 Dy0.4 Fe79.5 B6.5 magnets were investigated in low oxygen manufacturing process.The abnormal growth of grains occurs easily when the sintering temperature is higher th...The abnormal growth of grains of sintering Nd13.6 Dy0.4 Fe79.5 B6.5 magnets were investigated in low oxygen manufacturing process.The abnormal growth of grains occurs easily when the sintering temperature is higher than 1080℃ during the manufacture process.In the magnets, the oxygen content is less than 700 × 10-6 and the average particle size of powder is smaller than 4 μm.The squareness of demagnetization curve of magnet is deteriorated.For high performance magnets, the abnormal growth grain should be avoided by selecting a suitable sintering temperature.展开更多
Detecting stress concentration, especially critical stress state leading to structure damage or failure, is one of the most important tasks of equipment diagnosis. Metal magnetic memory technique needs further researc...Detecting stress concentration, especially critical stress state leading to structure damage or failure, is one of the most important tasks of equipment diagnosis. Metal magnetic memory technique needs further research to evaluate stress concentration quantitatively due to ambiguous physical mechanism, though it has potential to detect early defects in ferromagnetic materials. Mild Q235 steel defective specimens in demagnetization state were loaded in tension up to visible necking, with magnetic memory signals measurement made at increasing stress levels. Magnetic signals varied greatly under first several loadings and subsequently tended to stability in the elastic region, which showed that the magnetization always approaches the anhysteretic magnetization curve and was explained by the theory of magnetomechanical effect. In the plastic stage, an abnormal wave occurred in the stress concentration zone and its height value was sensitive to plastic deformation levels and dependent on the distance between the probe and defect, in accordance with the simulation results based on the magnetic dipole model. Different magnetic signal characteristics in the elastic-plastic region indicate that the magnetic memory technique can identify macroyielding and early damage, which is of profound significance for ensuring safe operation of equipment in service.展开更多
Our previous study used regional homogeneity analysis and found that activity in some brain areas of patients with ischemic stroke changed significantly. In the current study, we examined structural changes in these b...Our previous study used regional homogeneity analysis and found that activity in some brain areas of patients with ischemic stroke changed significantly. In the current study, we examined structural changes in these brain regions by taking structural magnetic resonance imaging scans of 11 ischemic stroke patients and 15 healthy participants, and analyzing the data using voxel-based morphometry. Compared with healthy participants, patients exhibited higher gray matter density in the left inferior occipital gyrus and right anterior white matter tract. In contrast, gray matter density in the right cerebellum, left precentral gyrus, right middle frontal gyrus, and left middle temporal gyrus was less in ischemic stroke patients. The changes of gray matter density in the middle frontal gyrus were negatively associated with the clin- ical rating scales of the Fugl-Meyer Motor Assessment (r = -0.609, P = 0.047) and the left middle temporal gyrus was negatively correlated with the clinical rating scales of the nervous functional deficiency scale (r = -0.737, P = 0.010). Our findings call objectively identify the functional abnormality in some brain regions of ischemic stroke patients.展开更多
Statistical model of magnetization reversal was used to simulate the magnetization reversal behavior in the sintered Nd-Fe-B magnets with double grain-size distributions due to the abnormal grain growth (AGG). The mag...Statistical model of magnetization reversal was used to simulate the magnetization reversal behavior in the sintered Nd-Fe-B magnets with double grain-size distributions due to the abnormal grain growth (AGG). The magnetic properties and mechanical properties due to the formation of AGG grains in Nd-Fe-B sintered magnets were tested. The results show that the magnetic properties, especially the rectangularity were severely deteriorated after the formation of the AGG grains and a step was shown on the demagnetization curve, and the occurrence of AGG may account for the poor rectangularity and existence of the step on demagnetization curve according to the statistical model of magnetization reversal. The fracture toughness and bending strength are lowered because of the stress concentration in the AGG grains. The SEM images show that the formation of AGG grains is caused by the solid sintering due to the absence of RE-rich phase. Statistical model of magnetization reversal can qualitative by explain the dependence of the magnetization reversal behavior on the grain size in the Nd-Fe-B sintered magnets.展开更多
A novel classification algorithm based on abnormal magnetic signals is proposed for ground moving targets which are made of ferromagnetic material. According to the effect of diverse targets on earth's magnetism,t...A novel classification algorithm based on abnormal magnetic signals is proposed for ground moving targets which are made of ferromagnetic material. According to the effect of diverse targets on earth's magnetism,the moving targets are detected by a magnetic sensor and classified with a simple computation method. The detection sensor is used for collecting a disturbance signal of earth magnetic field from an undetermined target. An optimum category match pattern of target signature is tested by training some statistical samples and designing a classification machine. Three ordinary targets are researched in the paper. The experimental results show that the algorithm has a low computation cost and a better sorting accuracy. This classification method can be applied to ground reconnaissance and target intrusion detection.展开更多
Investigation into the magnets with different squareness of hysteresis loop(SHL) reveals that the microstructure of sintered NdFeB magnets has great effects on the SHL of the magnets. The abnormal grain growth deterio...Investigation into the magnets with different squareness of hysteresis loop(SHL) reveals that the microstructure of sintered NdFeB magnets has great effects on the SHL of the magnets. The abnormal grain growth deteriorates the SHL seriously. The shape of the grain and the grain boundary affect the intensity of demagnetization field, and consequently on the SHL. The added elements have effects on the phase structures and distributions in the magnets, which influences the uniform of demagnetization field.展开更多
Schizophrenia(SZ)is one of the most common mental diseases.Its main characteristics are abnormal social behavior and inability to correctly understand real things.In recent years,the magnetic resonance imaging(MRI)tec...Schizophrenia(SZ)is one of the most common mental diseases.Its main characteristics are abnormal social behavior and inability to correctly understand real things.In recent years,the magnetic resonance imaging(MRI)technique has been popularly utilized to study SZ.However,it is still a great challenge to reveal the essential information contained in the MRI data.In this paper,we proposed a biomarker selection approach based on the multiple hypothesis testing techniques to explore the difference between SZ and healthy controls by using both functional and structural MRI data,in which biomarkers represent both abnormal brain functional connectivity and abnormal brain regions.By implementing the biomarker selection approach,six abnormal brain regions and twenty-three abnormal functional connectivity in the brains of SZ are explored.It is discovered that compared with healthy controls,the significantly reduced gray matter volumes are mainly distributed in the limbic lobe and the basal ganglia,and the significantly increased gray matter volumes are distributed in the frontal gyrus.Meanwhile,it is revealed that the significantly strengthened connections are those between the middle frontal gyrus and the superior occipital gyrus,the superior occipital gyrus and the middle occipital gyrus as well as the middle occipital gyrus and the fusiform gyrus,and the rest connections are significantly weakened.展开更多
基金This work was supported by the National Nature Science Foundation of China (No. 19934003) the State Key Project of Fundamental Research of China (No.001CB610604) the Item of Nature Science Research of Anhui (No. 2001kj244).
文摘通过测量样品的磁化强度-温度曲线、电阻率-温度曲线及磁电阻-温度曲线.研究了 Dy 掺杂(0.00≤x≤0.30)对 La_(0.7-x)Dy_xSr_(0.3)MnO_3 体系磁电性质的影响.实验发现,随 Dy 掺杂量的增加,体系磁结构从长程铁磁有序向自旋团簇玻璃态、反铁磁状态转变;x=0.20、0.30时的低温磁行为发生异常,电行为存在低温电阻率极小值现象.这些奇特现象不仅来源于掺杂引起的晶格效应,也来源于掺杂引起的额外磁性耦合.
文摘AIM:to study the prevalence and patterns of hepatic abnormal perfusion(HAP)visible by magnetic resonance imaging(MRI)in acute pancreatitis(AP).METHODS:Enhanced abdominal MRI was performed on 51 patients with AP.these patients were divided into two groups according to the MRI results:those with signs of gallstones,cholecystitis,common bile duct(CBD)stones or dilatation of the CBD on MRI and those without.the prevalence,shape and distribution of HAP in the two groups were analyzed and compared.the severity of AP was graded using the MR severity index(MRSI).the correlation between the MRSI and HAP was then analyzed.RESULTS:Of the 51 patients with AP,32(63%)showed at least one sign of gallbladder and CBD abnormalities on the MR images,while 19(37%)showed no sign of gallbladder or CBD abnormalities.Nineteen patients(37%)had HAP visible in the enhanced images,including strip-,wedge-or patch-shaped HAP distributed in the hepatic tissue adjacent to the gallbladder and left and right liver lobes.there were no significant differences in the prevalence of HAP(χ2=0.305,P=0.581>0.05)or HAP distribution in the liver(χ2=2.181,P=0.536>0.05)between patients with and without gallbladder and CBD abnormalities.there were no significant differences in the MRSI score between patients with and without HAP(t=0.559,P=0.552>0.05).HAP was not correlated with the MRSI score.CONCLUSION:HAP is common in patients with AP and appears strip-,patch-or wedge-shaped on MRI.HAP on MRI cannot be used to indicate the severity of AP.
文摘Insomnia is one of the most frequently observed sleep disorders, affecting nearly 10% of the general population. It has multiple etiological factors. Recently, it has been reported that EEG abnormalities are associated with insomnia in patients previously diagnosed as idiopathic insomniacs. In addition, transcranial magnetic stimulation (TMS) has shown to be effective in the treatment of disorders characterized by neural hyper-excitability. Method: In the present study, patients with insomnia and EEG abnormalities were submitted to slow repetitive trans-cranial magnetic stimulation, for 15 minutes daily during 10 days. Polysomnographic recordings were performed before and after TMS. Results: The results indicate that the presence of EEG abnormalities significantly decreased after TMS. In addition, most of the sleep parameters showed significant improvement. Conclusions: These data support the notion that TMS is a reliable therapeutic tool for patients affected with abnormalities linked to neuronal hyper-excitability.
文摘Residual stresses in ferromagnetic material affect the direction and structure of domains and generate magnetic field abnormality on the surface. In the formation of stress induced magnetic field, the influence of geomagnetic field is unclear. Residual stress specimen was produced by tight matching of a round ring and a peg. The magnetic fields of contrast specimens, which were produced in geomagnetic field or in shielding geomagnetic field, were inspected with 8 mm lift-off. The results show that mean amplitude of magnetic field of the specimen produced in geomagnetic field is 0.85% larger than that of specimen produced in shielding geomagnetic field. So the formation of stress induced magnetic field abnormality above the surface of inspected ferromagnetic material geomagnetic field gives little contribution.
基金Program for New Century Excellent Talents in University (NCET) of ChinaFundation of the Key Lab of Infrared and Low Temperature Plasma of Anhui Province of China(No.2007A003003U)
文摘Abstract In the four-anode device, the mirror magnetic field affects the characteristics of charged particles motion, so that the current-voltage relations of glow discharge are changed. Firstly, the discharge device is introduced, and the distribution of mirror magnetic field generated by the loops surrounding the discharge chamber is presented. Both the discharge current-voltage characteristics and the radial distributions of electron density are measured, respectively, with/without the magnetic field. When the discharge occurs in a 99.99% helium with a pressure ranging from 100 Pa to 800 Pa without magnetic field, the voltage, sustaining a certain abnormal glow discharge current, decreases with the increase in gas pressure. With a mirror magnetic field of certain intensity, the discharge voltage increases with the current in a rate slower than that without the magnetic field. Moreover, when the magnetic field intensity increases, the discharge voltage first decreases then increases. Simultaneously, the mirror magnetic field affects the moving characteristics of charged particles, and causes a more inhomogeneous electron density.
文摘The abnormal growth of grains of sintering Nd13.6 Dy0.4 Fe79.5 B6.5 magnets were investigated in low oxygen manufacturing process.The abnormal growth of grains occurs easily when the sintering temperature is higher than 1080℃ during the manufacture process.In the magnets, the oxygen content is less than 700 × 10-6 and the average particle size of powder is smaller than 4 μm.The squareness of demagnetization curve of magnet is deteriorated.For high performance magnets, the abnormal growth grain should be avoided by selecting a suitable sintering temperature.
基金supported by National Natural Science Foundation of China(Grant No. 10772061)Heilongjiang Provincial Natural Science Foundation of China(Grant No. A200907)Specialized Research Fundfor the Doctoral Program of Higher Education of China(Grant No.20092322120001)
文摘Detecting stress concentration, especially critical stress state leading to structure damage or failure, is one of the most important tasks of equipment diagnosis. Metal magnetic memory technique needs further research to evaluate stress concentration quantitatively due to ambiguous physical mechanism, though it has potential to detect early defects in ferromagnetic materials. Mild Q235 steel defective specimens in demagnetization state were loaded in tension up to visible necking, with magnetic memory signals measurement made at increasing stress levels. Magnetic signals varied greatly under first several loadings and subsequently tended to stability in the elastic region, which showed that the magnetization always approaches the anhysteretic magnetization curve and was explained by the theory of magnetomechanical effect. In the plastic stage, an abnormal wave occurred in the stress concentration zone and its height value was sensitive to plastic deformation levels and dependent on the distance between the probe and defect, in accordance with the simulation results based on the magnetic dipole model. Different magnetic signal characteristics in the elastic-plastic region indicate that the magnetic memory technique can identify macroyielding and early damage, which is of profound significance for ensuring safe operation of equipment in service.
基金financially supported by the National Program on Key Basic Research Project of China(973 Program)No.2012CB518501the National Natural Science Foundation of China,No.81072864
文摘Our previous study used regional homogeneity analysis and found that activity in some brain areas of patients with ischemic stroke changed significantly. In the current study, we examined structural changes in these brain regions by taking structural magnetic resonance imaging scans of 11 ischemic stroke patients and 15 healthy participants, and analyzing the data using voxel-based morphometry. Compared with healthy participants, patients exhibited higher gray matter density in the left inferior occipital gyrus and right anterior white matter tract. In contrast, gray matter density in the right cerebellum, left precentral gyrus, right middle frontal gyrus, and left middle temporal gyrus was less in ischemic stroke patients. The changes of gray matter density in the middle frontal gyrus were negatively associated with the clin- ical rating scales of the Fugl-Meyer Motor Assessment (r = -0.609, P = 0.047) and the left middle temporal gyrus was negatively correlated with the clinical rating scales of the nervous functional deficiency scale (r = -0.737, P = 0.010). Our findings call objectively identify the functional abnormality in some brain regions of ischemic stroke patients.
基金This work was financially supported by the National Natural Science Foundation of China (No.50371019) and Beijing Municipal Science & Technology Commission Key Project (D0406002000091).
文摘Statistical model of magnetization reversal was used to simulate the magnetization reversal behavior in the sintered Nd-Fe-B magnets with double grain-size distributions due to the abnormal grain growth (AGG). The magnetic properties and mechanical properties due to the formation of AGG grains in Nd-Fe-B sintered magnets were tested. The results show that the magnetic properties, especially the rectangularity were severely deteriorated after the formation of the AGG grains and a step was shown on the demagnetization curve, and the occurrence of AGG may account for the poor rectangularity and existence of the step on demagnetization curve according to the statistical model of magnetization reversal. The fracture toughness and bending strength are lowered because of the stress concentration in the AGG grains. The SEM images show that the formation of AGG grains is caused by the solid sintering due to the absence of RE-rich phase. Statistical model of magnetization reversal can qualitative by explain the dependence of the magnetization reversal behavior on the grain size in the Nd-Fe-B sintered magnets.
基金Sponsored by the National Natural Science Foundation of China (60773129)the Excellent Youth Science and Technology Foundation of Anhui Province of China ( 08040106808)
文摘A novel classification algorithm based on abnormal magnetic signals is proposed for ground moving targets which are made of ferromagnetic material. According to the effect of diverse targets on earth's magnetism,the moving targets are detected by a magnetic sensor and classified with a simple computation method. The detection sensor is used for collecting a disturbance signal of earth magnetic field from an undetermined target. An optimum category match pattern of target signature is tested by training some statistical samples and designing a classification machine. Three ordinary targets are researched in the paper. The experimental results show that the algorithm has a low computation cost and a better sorting accuracy. This classification method can be applied to ground reconnaissance and target intrusion detection.
基金Project supported by Shanghai Leading Academic Discipline (P1502)
文摘Investigation into the magnets with different squareness of hysteresis loop(SHL) reveals that the microstructure of sintered NdFeB magnets has great effects on the SHL of the magnets. The abnormal grain growth deteriorates the SHL seriously. The shape of the grain and the grain boundary affect the intensity of demagnetization field, and consequently on the SHL. The added elements have effects on the phase structures and distributions in the magnets, which influences the uniform of demagnetization field.
基金This work was supported by NSFC(No.11471006 and No.81601456),Science and Technology Innovation Plan of Xi’an(No.2019421315KYPT004JC006)and the HPC Platform,Xi’an Jiaotong University.
文摘Schizophrenia(SZ)is one of the most common mental diseases.Its main characteristics are abnormal social behavior and inability to correctly understand real things.In recent years,the magnetic resonance imaging(MRI)technique has been popularly utilized to study SZ.However,it is still a great challenge to reveal the essential information contained in the MRI data.In this paper,we proposed a biomarker selection approach based on the multiple hypothesis testing techniques to explore the difference between SZ and healthy controls by using both functional and structural MRI data,in which biomarkers represent both abnormal brain functional connectivity and abnormal brain regions.By implementing the biomarker selection approach,six abnormal brain regions and twenty-three abnormal functional connectivity in the brains of SZ are explored.It is discovered that compared with healthy controls,the significantly reduced gray matter volumes are mainly distributed in the limbic lobe and the basal ganglia,and the significantly increased gray matter volumes are distributed in the frontal gyrus.Meanwhile,it is revealed that the significantly strengthened connections are those between the middle frontal gyrus and the superior occipital gyrus,the superior occipital gyrus and the middle occipital gyrus as well as the middle occipital gyrus and the fusiform gyrus,and the rest connections are significantly weakened.