Long Acting Injectable (LAI) medications for patients with schizophrenia is commonly administered to relieve their symptoms. Through shared decision-making and clinical evidence-based, psychiatrists should systematica...Long Acting Injectable (LAI) medications for patients with schizophrenia is commonly administered to relieve their symptoms. Through shared decision-making and clinical evidence-based, psychiatrists should systematically offer LAIs to all patients requiring long-term antipsychotic treatment as a first-line treatment. Gluteal intramuscular (IM) injection requires accurate insertion of needles into the specific muscle area, often the outer upper quadrant of the buttocks, in order to achieve the required blood concentration. The purposes of this study were to compare the “Distance from the Epidermis to the Under-Fascia (DEUF)” and “Distance from the Epidermis to the Iliac Bone (DEB)” of the buttocks IM injection sites at the dorsogluteal and ventrogluteal sites among healthy Japanese volunteer subjects, and to identify the optimal insertion injection needle length. The DEUF and DEB at the gluteal regions were measured by ultrasonography. Welch’s one-way analysis of variance was used to compare the DEUF and the DEB at the gluteal IM injection regions. There was no statistically significant difference observed between the right and left mean values of DEUF for Hochstetter and Clark’s point at the ventrogluteal sites, and the Four and Three-way split or Double Cross point at the dorsogluteal sites. However in the DEB, the Hochstetter’s point (P < 0.01) at ventrogluteal site on the right side, and Clark’s point (P < 0.05) were significantly shorter than the Double Cross point at dorsogluteal sites (F = 4.38). The left buttocks Hochstetter’s point was significantly shorter than the Double Cross point (F = 4.38, P < 0.01). These results, however, did not establish a statistically significant difference in the DEUF among injection sites. It was considered that the difference in the DEB depended on muscle volume and thickness in the gluteal injection sites.展开更多
Risperidone long-acting injectable (RLAI) is approved for the treatment of schizophrenia in many countries. The suggested site is the gluteal muscle with a needle length of two inches (50 mm) in Japan, which is longer...Risperidone long-acting injectable (RLAI) is approved for the treatment of schizophrenia in many countries. The suggested site is the gluteal muscle with a needle length of two inches (50 mm) in Japan, which is longer than the ordinarily used needle for intramuscular injections. The aim of this study was to determine the optimal needle insertion length for accurate delivery of RLAI procedure among subjects who have normal body mass index (BMI: 18 to 25) and high BMI (>25). Thirty-seven patients with schizophrenia were administered RLAI intramuscularly into the dorsogluteal muscle. The standard procedure required inserting 80% of the two inch needle. By using data collected by ultrasonography, the findings confirmed that the median needle insertion lengths for subjects with normal and high BMI were 39.0 and 45.5 mm, respectively. To deliver RLAI effectively and safely, the authors strongly recommend that a specialized needle be used that is “marked” at the 40 mm point from the tip of the needle to the base. In this way regardless of subcutaneous fat content, the RLAI can be safely delivered into the muscle without causing untoward or side effects.展开更多
Adjuvanted vaccines are recommended for administration through an intramuscular route. The Centers for Disease Control and Prevention (CDC) has recommended the anterolateral thigh using a 22 - 25-G 25-mm (1 inch) need...Adjuvanted vaccines are recommended for administration through an intramuscular route. The Centers for Disease Control and Prevention (CDC) has recommended the anterolateral thigh using a 22 - 25-G 25-mm (1 inch) needle for infants, injected at a 90° into the skin surface, and using a 16 mm (5/8 inch) for newborns. Appropriate needle lengths may differ depending on racial backgrounds. In the present study, the thickness of the epidermis and lengths from the skin surface to the muscle fascia and bone were measured using ultrasonic echograms in order to determine suitable needle lengths for Japanese infants aged 2, 3, 4, 5, 6, and 12 - 15 months old. The thickness of the epidermis was 1.44 - 1.54 mm (95% CI), and the lengths from the skin surface to the muscle fascia and bone were 11.52 - 12.28 mm (95% CI), and 25.66 - 26.93 mm (95% CI), respectively, at the anterolateral thigh. At the center of the deltoid muscle, skin thickness was similar to that at the thigh, furthermore the lengths from the skin surface to the muscle fascia and bone were 8.49 - 9.10 mm (95% CI), and 17.38 - 18.31 mm (95% CI), respectively. The lengths from the skin surface to the muscle fascia and bone were 1 - 2 mm shorter in 2-month-old infants than those in older generations. Therefore, the appropriate needle length for intramuscular injections in Japanese infants was 16 mm (5/8 inch) at any age and sites, and with 25 mm (1 inch) needles at a 90° angle being associated with the risk of over-penetration.展开更多
In this paper,the relations between the parameters of stitch structure and the needle penetra-tion force,and the method by using the needle penetration force detected to evaluate the looplength and evenness of knitted...In this paper,the relations between the parameters of stitch structure and the needle penetra-tion force,and the method by using the needle penetration force detected to evaluate the looplength and evenness of knitted fabric indirectly are analysed and discussed.A microcomputer system with a needle sensor and author’s program are used as a pick up setcombined with a data analysis system,for sampling and analysing the needle penetration forcedata.A lot of experimental research work has been done for knitted fabric of some kinds of knittedstitch and loop length.As a summary of this study,some conclusions can be drawn from the linearregression between the needle penetration force and the loop length.Then,the size and evenness ofthe loop length of knitted fabric can be indicated indirectly by detecting the value and variance ofneedle penetration force.It offers an effective method to detect and evaluate the evenness of knit-ted fabric with an efficiently high speed.展开更多
文摘Long Acting Injectable (LAI) medications for patients with schizophrenia is commonly administered to relieve their symptoms. Through shared decision-making and clinical evidence-based, psychiatrists should systematically offer LAIs to all patients requiring long-term antipsychotic treatment as a first-line treatment. Gluteal intramuscular (IM) injection requires accurate insertion of needles into the specific muscle area, often the outer upper quadrant of the buttocks, in order to achieve the required blood concentration. The purposes of this study were to compare the “Distance from the Epidermis to the Under-Fascia (DEUF)” and “Distance from the Epidermis to the Iliac Bone (DEB)” of the buttocks IM injection sites at the dorsogluteal and ventrogluteal sites among healthy Japanese volunteer subjects, and to identify the optimal insertion injection needle length. The DEUF and DEB at the gluteal regions were measured by ultrasonography. Welch’s one-way analysis of variance was used to compare the DEUF and the DEB at the gluteal IM injection regions. There was no statistically significant difference observed between the right and left mean values of DEUF for Hochstetter and Clark’s point at the ventrogluteal sites, and the Four and Three-way split or Double Cross point at the dorsogluteal sites. However in the DEB, the Hochstetter’s point (P < 0.01) at ventrogluteal site on the right side, and Clark’s point (P < 0.05) were significantly shorter than the Double Cross point at dorsogluteal sites (F = 4.38). The left buttocks Hochstetter’s point was significantly shorter than the Double Cross point (F = 4.38, P < 0.01). These results, however, did not establish a statistically significant difference in the DEUF among injection sites. It was considered that the difference in the DEB depended on muscle volume and thickness in the gluteal injection sites.
文摘Risperidone long-acting injectable (RLAI) is approved for the treatment of schizophrenia in many countries. The suggested site is the gluteal muscle with a needle length of two inches (50 mm) in Japan, which is longer than the ordinarily used needle for intramuscular injections. The aim of this study was to determine the optimal needle insertion length for accurate delivery of RLAI procedure among subjects who have normal body mass index (BMI: 18 to 25) and high BMI (>25). Thirty-seven patients with schizophrenia were administered RLAI intramuscularly into the dorsogluteal muscle. The standard procedure required inserting 80% of the two inch needle. By using data collected by ultrasonography, the findings confirmed that the median needle insertion lengths for subjects with normal and high BMI were 39.0 and 45.5 mm, respectively. To deliver RLAI effectively and safely, the authors strongly recommend that a specialized needle be used that is “marked” at the 40 mm point from the tip of the needle to the base. In this way regardless of subcutaneous fat content, the RLAI can be safely delivered into the muscle without causing untoward or side effects.
文摘Adjuvanted vaccines are recommended for administration through an intramuscular route. The Centers for Disease Control and Prevention (CDC) has recommended the anterolateral thigh using a 22 - 25-G 25-mm (1 inch) needle for infants, injected at a 90° into the skin surface, and using a 16 mm (5/8 inch) for newborns. Appropriate needle lengths may differ depending on racial backgrounds. In the present study, the thickness of the epidermis and lengths from the skin surface to the muscle fascia and bone were measured using ultrasonic echograms in order to determine suitable needle lengths for Japanese infants aged 2, 3, 4, 5, 6, and 12 - 15 months old. The thickness of the epidermis was 1.44 - 1.54 mm (95% CI), and the lengths from the skin surface to the muscle fascia and bone were 11.52 - 12.28 mm (95% CI), and 25.66 - 26.93 mm (95% CI), respectively, at the anterolateral thigh. At the center of the deltoid muscle, skin thickness was similar to that at the thigh, furthermore the lengths from the skin surface to the muscle fascia and bone were 8.49 - 9.10 mm (95% CI), and 17.38 - 18.31 mm (95% CI), respectively. The lengths from the skin surface to the muscle fascia and bone were 1 - 2 mm shorter in 2-month-old infants than those in older generations. Therefore, the appropriate needle length for intramuscular injections in Japanese infants was 16 mm (5/8 inch) at any age and sites, and with 25 mm (1 inch) needles at a 90° angle being associated with the risk of over-penetration.
文摘In this paper,the relations between the parameters of stitch structure and the needle penetra-tion force,and the method by using the needle penetration force detected to evaluate the looplength and evenness of knitted fabric indirectly are analysed and discussed.A microcomputer system with a needle sensor and author’s program are used as a pick up setcombined with a data analysis system,for sampling and analysing the needle penetration forcedata.A lot of experimental research work has been done for knitted fabric of some kinds of knittedstitch and loop length.As a summary of this study,some conclusions can be drawn from the linearregression between the needle penetration force and the loop length.Then,the size and evenness ofthe loop length of knitted fabric can be indicated indirectly by detecting the value and variance ofneedle penetration force.It offers an effective method to detect and evaluate the evenness of knit-ted fabric with an efficiently high speed.