Semi-supervised surface defect detection of wind turbine blades with YOLOv4
1
作者 Chao Huang Minghui Chen Long Wang 《Global Energy Interconnection》 EI CSCD 2024年第3期284-292,共9页
Timely inspection of defects on the surfaces of wind turbine blades can effectively prevent unpredictable accidents.To this end,this study proposes a semi-supervised object-detection network based on You Only Looking ... Timely inspection of defects on the surfaces of wind turbine blades can effectively prevent unpredictable accidents.To this end,this study proposes a semi-supervised object-detection network based on You Only Looking Once version 4(YOLOv4).A semi-supervised structure comprising a generative adversarial network(GAN)was designed to overcome the difficulty in obtaining sufficient samples and sample labeling.In a GAN,the generator is realized by an encoder-decoder network,where the backbone of the encoder is YOLOv4 and the decoder comprises inverse convolutional layers.Partial features from the generator are passed to the defect detection network.Deploying several unlabeled images can significantly improve the generalization and recognition capabilities of defect-detection models.The small-scale object detection capacity of the network can be improved by enhancing essential features in the feature map by adding the concurrent spatial and channel squeeze and excitation(scSE)attention module to the three parts of the YOLOv4 network.A balancing improvement was made to the loss function of YOLOv4 to overcome the imbalance problem of the defective species.The results for both the single-and multi-category defect datasets show that the improved model can make good use of the features of the unlabeled images.The accuracy of wind turbine blade defect detection also has a significant advantage over classical object detection algorithms,including faster R-CNN and DETR. 展开更多
关键词 Defect detection Generative adversarial network scSE attention Semi-supervision wind turbine
下载PDF
Wind Turbine Noise Reduction through Blade Retrofitting
2
作者 Sarah Seevers Robin Ward +4 位作者 Scotty Hutto Darryl House Nick Zelenka Manuel Perea Daniel Fonseca 《Open Journal of Modelling and Simulation》 2024年第3期75-88,共14页
This paper outlines a plan for the effective reduction of the audible sound level produced by aerodynamic noise from the power-generating turbine blades. The contribution of aerodynamic noise can be divided into two c... This paper outlines a plan for the effective reduction of the audible sound level produced by aerodynamic noise from the power-generating turbine blades. The contribution of aerodynamic noise can be divided into two categories: inflow turbulence and airfoil self-noise. The base model and retrofit blade designs were modeled in SolidWorks. Subsequently, noise prediction simulations were conducted and compared to the base blade model to determine which modification provided the greatest benefit using SolidWorks Flow Simulation. The result of this project is a series of blade retrofit recommendations that produce a more acoustically efficient design and reduce noise complaints while enabling turbines to be placed in locations that require quieter operations. 展开更多
关键词 wind turbine Noise Blade Retrofitting Aerodynamic Noise Electricity Generation
下载PDF
The Multi-Objective Optimization of AFPM Generators with Double-Sided Internal Stator Structures for Vertical Axis Wind Turbines
3
作者 Dandan Song Lianjun Zhou +2 位作者 Ziqi Peng Senhua Luo Jun Zhu 《Energy Engineering》 EI 2021年第5期1439-1452,共14页
The axial flux permanent magnet(AFPM)generator with double-sided internal stator structure is highly suitable for vertical axis wind turbines due to its high power density.The performance of the AFPM generator with do... The axial flux permanent magnet(AFPM)generator with double-sided internal stator structure is highly suitable for vertical axis wind turbines due to its high power density.The performance of the AFPM generator with double-sided internal stator structure can be improved by the reasonable design of electromagnetic parameters.To further improve the overall performance of the AFPM generator with double-sided internal stator structure,multivariable(coil widthω_(c),permanent magnet thickness h,pole arc coefficient α_(p) and working air gap l_(g))and multi-objective(generator efficiencyη,total harmonic distortion of the voltage THD and induced electromotive force amplitude EMF)functional relationships are innovatively established.Orthogonal analysis,mean analysis and variance analysis are performed on the influence parameters by combining the Taguchi method and response surface methodology to study the influence degrees of each influence parameter on the optimization objectives to determine the most appropriate electromagnetic parameters.The optimization results are verified by 3D finite element analysis.The optimized APFM generator with double-sided internal stator structure exhibits superior economy,stronger magnetic density,higher efficiency and improved power quality. 展开更多
关键词 wind turbine double-sided internal stator structure multi-objective optimization axial flux permanent magnet generator
下载PDF
Application of SABO-VMD-KELM in Fault Diagnosis of Wind Turbines
4
作者 Yuling HE Hao CUI 《Mechanical Engineering Science》 2023年第2期23-29,共7页
In order to improve the accuracy of wind turbine fault diagnosis,a wind turbine fault diagnosis method based on Subtraction-Average-Based Optimizer(SABO)optimized Variational Mode Decomposition(VMD)and Kernel Extreme ... In order to improve the accuracy of wind turbine fault diagnosis,a wind turbine fault diagnosis method based on Subtraction-Average-Based Optimizer(SABO)optimized Variational Mode Decomposition(VMD)and Kernel Extreme Learning Machine(KELM)is proposed.Firstly,the SABO algorithm was used to optimize the VMD parameters and decompose the original signal to obtain the best modal components,and then the nine features were calculated to obtain the feature vectors.Secondly,the SABO algorithm was used to optimize the KELM parameters,and the training set and the test set were divided according to different proportions.The results were compared with the optimized model without SABO algorithm.The experimental results show that the fault diagnosis method of wind turbine based on SABO-VMD-KELM model can achieve fault diagnosis quickly and effectively,and has higher accuracy. 展开更多
关键词 wind turbine generator Fault diagnosis Subtraction-Average-Based Optimizer(SABO) Variational Mode Decomposition(VMD) Kernel Extreme Learning Machine(KELM)
下载PDF
Performance analysis of 20 Pole 1.5 KW Three Phase Permanent Magnet Synchronous Generator for low Speed Vertical Axis Wind Turbine 被引量:2
5
作者 Shahrukh Adnan Khan Rajprasad K. Rajkumar +1 位作者 Rajparthiban K. Rajkumar Aravind CV 《Energy and Power Engineering》 2013年第4期423-428,共6页
This paper gives performance analysis of a three phase Permanent Magnet Synchronous Generator (PMSG) connected to a Vertical Axis Wind Turbine (VAWT). Low speed wind condition (less than 5 m/s) is taken in considerati... This paper gives performance analysis of a three phase Permanent Magnet Synchronous Generator (PMSG) connected to a Vertical Axis Wind Turbine (VAWT). Low speed wind condition (less than 5 m/s) is taken in consideration and the entire simulation is carried in Matlab/Simulink environment. The rated power for the generator is fixed at 1.5 KW and number of pole at 20. It is observed under low wind speed of6 m/s, a turbine having approximately1 mof radius and2.6 mof height develops 150 Nm mechanical torque that can generate power up to 1.5 KW. The generator is designed using modeling tool and is fabricated. The fabricated generator is tested in the laboratory with the simulation result for the error analysis. The range of error is about 5%-27% for the same output power value. The limitations and possible causes for error are presented and discussed. 展开更多
关键词 Vertical Axis wind turbine Three Phase Multi-pole PERMANENT MAGNET SYNCHRONOUS generator Low wind Speed Modeling Performance Analysis
下载PDF
An analytic electromagnetic calculation method for performance evolution of doubly fed induction generators for wind turbines 被引量:1
6
作者 张文娟 黄守道 +1 位作者 高剑 CHEN Zhe 《Journal of Central South University》 SCIE EI CAS 2013年第10期2763-2774,共12页
An analytic electromagnetic calculation method for doubly fed induction generator(DFIG) in wind turbine system was presented. Based on the operation principles, steady state equivalent circuit and basic equations of D... An analytic electromagnetic calculation method for doubly fed induction generator(DFIG) in wind turbine system was presented. Based on the operation principles, steady state equivalent circuit and basic equations of DFIG, the modeling for electromagnetic calculation of DFIG was proposed. The electromagnetic calculation of DFIG was divided into three steps: the magnetic flux calculation, parameters derivation and performance checks. For each step, the detailed numeric calculation formulas were all derived. Combining the calculation formulas, the whole electromagnetic calculation procedure was established, which consisted of three iterative calculation loops, including magnetic saturation coefficient, electromotive force and total output power. All of the electromagnetic and performance data of DIFG can be calculated conveniently by the established calculation procedure, which can be used to evaluate the new designed machine. A 1.5 MW DFIG designed by the proposed procedure was built, for which the whole type tests including no-load test, load test and temperature rising test were carried out. The test results have shown that the DFIG satisfies technical requirements and the test data fit well with the calculation results which prove the correctness of the presented calculation method. 展开更多
关键词 ELECTROMAGNETIC calculation DOUBLY fed INDUCTION generator(DFIG) wind turbine
下载PDF
Dynamic modeling and direct power control of wind turbine driven DFIG under unbalanced network voltage conditions 被引量:2
7
作者 Jia-bing HU Yi-kang HE Lie XU 《Journal of Zhejiang University-Science A(Applied Physics & Engineering)》 SCIE EI CAS CSCD 2008年第12期1731-1740,共10页
This paper proposes an analysis and a direct power control (DPC) design of a wind turbine driven doubly-fed induction generator (DFIG) under unbalanced network voltage conditions. A DFIG model described in the positiv... This paper proposes an analysis and a direct power control (DPC) design of a wind turbine driven doubly-fed induction generator (DFIG) under unbalanced network voltage conditions. A DFIG model described in the positive and negative synchronous reference frames is presented. Variations of the stator output active and reactive powers are fully deduced in the presence of negative sequence supply voltage and rotor flux. An enhanced DPC scheme is proposed to eliminate stator active power oscillation during network unbalance. The proposed control scheme removes rotor current regulators and the decomposition processing of positive and negative sequence rotor currents. Simulation results using PSCAD/EMTDC are presented on a 2-MW DFIG wind power generation system to validate the feasibility of the proposed control scheme under balanced and unbalanced network conditions. 展开更多
关键词 Doubly-fed induction generator (DFIG) wind turbine Direct power control (DPC) Stator voltage oriented (SVO) Unbalanced network
下载PDF
A Sliding Mode Approach to Enhance the Power Quality of Wind Turbines Under Unbalanced Voltage Conditions 被引量:2
8
作者 Mohammad Javad Morshed Afef Fekih 《IEEE/CAA Journal of Automatica Sinica》 SCIE EI CSCD 2019年第2期566-574,共9页
An integral terminal sliding mode-based control design is proposed in this paper to enhance the power quality of wind turbines under unbalanced voltage conditions. The design combines the robustness, fast response, an... An integral terminal sliding mode-based control design is proposed in this paper to enhance the power quality of wind turbines under unbalanced voltage conditions. The design combines the robustness, fast response, and high quality transient characteristics of the integral terminal sliding mode control with the estimation properties of disturbance observers. The controller gains were auto-tuned using a fuzzy logic approach.The effectiveness of the proposed design was assessed under deep voltage sag conditions and parameter variations. Its dynamic response was also compared to that of a standard SMC approach.The performance analysis and simulation results confirmed the ability of the proposed approach to maintain the active power,currents, DC-link voltage and electromagnetic torque within their acceptable ranges even under the most severe unbalanced voltage conditions. It was also shown to be robust to uncertainties and parameter variations, while effectively mitigating chattering in comparison with the standard SMC. 展开更多
关键词 Doubly fed induction generators(DFIG) fuzzy approach integral terminal sliding mode control(ITSMC) OBSERVER power quality voltage unbalances wind turbines
下载PDF
Experimental Study on Aerodynamic Characteristics of the Model Wind Rotor System and on Characterization of A Wind Generation System 被引量:2
9
作者 MENG Long HE Yan-ping +2 位作者 ZHAO Yong-sheng PENG Tao YANG Jie 《China Ocean Engineering》 SCIE EI CSCD 2019年第2期137-147,共11页
In order to investigate the aerodynamic characteristics of 6-MW wind turbine, experimental study on the aerodynamic characteristics of the model rotor system and on characterization of a wind generation system is carr... In order to investigate the aerodynamic characteristics of 6-MW wind turbine, experimental study on the aerodynamic characteristics of the model rotor system and on characterization of a wind generation system is carried out. In the test, a thrust-matched rotor system and a geometry-matched rotor system, which utilize redesigned thrustmatched and original geometry-matched blades, respectively, are applied. The 6-MW wind turbine system is introduced briefly. The proper scaling laws for model tests are established in the paper, which are then implemented in the construction of a model wind turbine with optimally designed blades. And the parameters of the model are provided. The aerodynamic characteristics of the proposed 6-MW wind rotor system are explored by testing a 1:65.3 scale model at the State Key Laboratory of Ocean Engineering at Shanghai Jiao Tong University. Before carrying out the wind rotor system test, the turbulence intensity and spatial uniformity of the wind generation system are tested and results demonstrate that the characterization of the wind generation system is satisfied and the average turbulence intensity of less than 10% within the wind rotor plane is proved in the test. And then, the aerodynamic characteristics of 6-MW wind rotor system are investigated. The response characteristic differences between the thrust-matched rotor system and the geometry-matched rotor system are presented. Results indicate that the aerodynamic characteristics of 6-MW wind rotor with the thrust-matched rotor system are satisfied. The conclusion is that the thrust-matched rotor system can better reflect the characteristics of the prototype wind turbine. A set of model test method is proposed in the work and preparations for further model basin test of the 6-MW SPAR-type floating offshore wind turbine system are made. 展开更多
关键词 thrust-matched ROTOR SYSTEM geometry-matched ROTOR SYSTEM wind generation SYSTEM experimental study aerodynamic characteristics
下载PDF
PI-MPC Frequency Control of Power System in the Presence of DFIG Wind Turbines 被引量:1
10
作者 Michael Z. Bernard T. H. Mohamed +2 位作者 Raheel Ali Yasunori Mitani Yaser Soliman Qudaih 《Engineering(科研)》 2013年第9期43-50,共8页
For the recent expansion of renewable energy applications, Wind Energy System (WES) is receiving much interest all over the world. However, area load change and abnormal conditions lead to mismatches in frequency and ... For the recent expansion of renewable energy applications, Wind Energy System (WES) is receiving much interest all over the world. However, area load change and abnormal conditions lead to mismatches in frequency and scheduled power interchanges between areas. These mismatches have to be corrected by the LFC system. This paper, therefore, proposes a new robust frequency control technique involving the combination of conventional Proportional-Integral (PI) and Model Predictive Control (MPC) controllers in the presence of wind turbines (WT). The PI-MPC technique has been designed such that the effect of the uncertainty due to governor and turbine parameters variation and load disturbance is reduced. A frequency response dynamic model of a single-area power system with an aggregated generator unit is introduced, and physical constraints of the governors and turbines are considered. The proposed technique is tested on the single-area power system, for enhancement of the network frequency quality. The validity of the proposed method is evaluated by computer simulation analyses using Matlab Simulink. The results show that, with the proposed PI-MPC combination technique, the overall closed loop system performance demonstrated robustness regardless of the presence of uncertainties due to variations of the parameters of governors and turbines, and loads disturbances. A performance comparison between the proposed control scheme, the classical PI control scheme and the MPC is carried out confirming the superiority of the proposed technique in presence of doubly fed induction generator (DFIG) WT. 展开更多
关键词 DOUBLY Fed Induction generator Power SYSTEM Model PREDICTIVE Control) Proportional Integral Controller DFIG wind turbine wind Energy SYSTEM (WES)
下载PDF
Isolated MicroGrid’s Voltage and Frequency Characteristic with Induction Generator Based Wind Turbine 被引量:1
11
作者 Woo-Kyu Chae Hak-Ju Lee +2 位作者 Sung-Wook Hwang Il-Keun Song Jae-Eon Kim 《Smart Grid and Renewable Energy》 2014年第7期180-192,共13页
To save on the island area's power supply cost and protect the clean environment, the Isolated MicroGrid is being duly considered. Consisting of the Wind Turbine Generator (WT), photovoltaic generator, battery sys... To save on the island area's power supply cost and protect the clean environment, the Isolated MicroGrid is being duly considered. Consisting of the Wind Turbine Generator (WT), photovoltaic generator, battery system, back-up diesel generator, etc., Isolated MicroGrid, which usually uses the inverter to maintain voltage and frequency of the system, is very weak in terms of voltage and frequency stability compared to the large-scale electrical power system. If wind turbine generator is applied to this weak power system, it could experience many problems in terms of maintaining its voltage and frequency. In this paper, the measurement result of voltage and frequency is presented for MicroGrid, which consists of the Wind Turbine Generator adopting the induction generator and the battery system. MicroGrid’s voltage waveform distortion and Wind Turbine Generator’s output oscillation problems are analyzed using PSCAD/EMTDC. Based on the analyzed result, the importance of type and capacity choice has been suggested in case the Wind Turbine Generator is applied to the Isolated MicroGrid. 展开更多
关键词 MICROGRID wind turbine INDUCTION generator Battery VOLTAGE Frequency PSCAD/EMTDC
下载PDF
Impact of the Fermeuse Wind Farm on Newfoundland Grid
12
作者 Seyedali Meghdadi Tariq Iqbal 《Energy and Power Engineering》 2015年第6期258-269,共12页
This paper aims to study the impact of the Fermeuse wind farm (46&deg58'42'N 52&deg57'18'W) through simulation of wind turbines driven by doubly fed induction generator which feed AC power to t... This paper aims to study the impact of the Fermeuse wind farm (46&deg58'42'N 52&deg57'18'W) through simulation of wind turbines driven by doubly fed induction generator which feed AC power to the isolated utility grid of Newfoundland. The focus is on the determination of both voltage and system stability constraints. The complete system is modeled and simulated in Matlab Simulink environment. 展开更多
关键词 Renewable ENERGY SYSTEMS Fermeuse wind FARM wind turbine DOUBLY Fed Induction generator wind ENERGY Conversion SYSTEMS
下载PDF
Characteristics of Mechanical and Electrical Power Transmission for Small-Scaled Wind Turbine
13
作者 Kyu-Jin Lee Hyun-Dai Yang +3 位作者 Sung-Hoon Park Sung-Do Song Byung-Sun Kim Joong-Ho Shin 《World Journal of Engineering and Technology》 2016年第3期82-90,共10页
Small-scaled wind turbine is converted to mechanical power of windmill to electric power by generator. However almost all studies seems to have overlooked converting relation of mechanical & electric power. It the... Small-scaled wind turbine is converted to mechanical power of windmill to electric power by generator. However almost all studies seems to have overlooked converting relation of mechanical & electric power. It the reason for was very difficult establishing wind turbine system. In this paper, it is define equation of converting relation of mechanical & electric power. And it is verified by experimental methods. Defined equation will be used in developing electric devices such as inverter and controller in wind turbines. In addition this method can be used in the fields that utilize the rotational power into electrical power through generator. 展开更多
关键词 wind turbine generator Mechanical Power Electrical Power
下载PDF
The Measuring System for Estimation of Power of Wind Flow Generated by Train Movement and Its Experimental Testing
14
作者 Oleksandr Mokin Borys Mokin Vadym Bazalytskyy 《Energy and Power Engineering》 2014年第11期333-339,共7页
The measuring system for estimation of power of wind flow generated by the train movement has been created. The advantages of the proposed system are the cheapness and simple design. With its simplicity of design and ... The measuring system for estimation of power of wind flow generated by the train movement has been created. The advantages of the proposed system are the cheapness and simple design. With its simplicity of design and easy build-up of channels, designed measuring system can be used for a wide range of technical problems. This paper describes the design process, validation and conducting the first field test of this measuring system. 展开更多
关键词 POWER Generation wind turbine wind Flow Sensor Measurement
下载PDF
Analysis of Offshore Wind Power: Application to Southern Thailand
15
作者 J. Waewsak C. Kongruang +1 位作者 M. Landry Y. Gagnon 《Journal of Energy and Power Engineering》 2011年第11期1096-1101,共6页
This paper presents an analysis of a pre-feasibility study of a 10 MW offshore wind power project in Nakhon Si Thammarat province, southern Thailand. The wind speeds at the hub heights of large scale wind turbine gene... This paper presents an analysis of a pre-feasibility study of a 10 MW offshore wind power project in Nakhon Si Thammarat province, southern Thailand. The wind speeds at the hub heights of large scale wind turbine generators (WTG), i.e. 80-100 m, were extrapolated using monthly mean wind shear coefficients and the l/7th exponent. Using WAsP 9.0, the annual energy production from several models of offshore wind farms using different WTG was analyzed. The capacity factor and the cost of energy were then computed. Using best available estimates, the analysis shows that the estimated annual mean offshore wind speeds at 80-100 m were in the range of 6.4 and 8.3 m/s. The annual energy production by the wind farm from nine models of wind turbine generators were in the range of 20-39 GWh/year, corresponding to a capacity factor in the range of 26-46%, while the cost of energy was 12-15 US cent/kWh. 展开更多
关键词 offshore wind energy annual energy production Weibull distribution wind turbine generator wind resource assessment.
下载PDF
Maximum Power Point Tracking in Variable Speed Wind Turbine Based on Permanent Magnet Synchronous Generator Using Maximum Torque Sliding Mode Control Strategy 被引量:3
16
作者 Esmaeil Ghaderi Hossein Tohidi Behnam Khosrozadeh 《Journal of Electronic Science and Technology》 CAS CSCD 2017年第4期391-399,共9页
The present study was carried out in order to track the maximum power point in a variable speed turbine by minimizing electromechanical torque changes using a sliding mode control strategy. In this strategy, first, th... The present study was carried out in order to track the maximum power point in a variable speed turbine by minimizing electromechanical torque changes using a sliding mode control strategy. In this strategy, first, the rotor speed is set at an optimal point for different wind speeds. As a result of which, the tip speed ratio reaches an optimal point, mechanical power coefficient is maximized, and wind turbine produces its maximum power and mechanical torque. Then, the maximum mechanical torque is tracked using electromechanical torque. In this technique, tracking error integral of maximum mechanical torque, the error, and the derivative of error are used as state variables. During changes in wind speed, sliding mode control is designed to absorb the maximum energy from the wind and minimize the response time of maximum power point tracking(MPPT). In this method, the actual control input signal is formed from a second order integral operation of the original sliding mode control input signal. The result of the second order integral in this model includes control signal integrity, full chattering attenuation, and prevention from large fluctuations in the power generator output. The simulation results, calculated by using MATLAB/m-file software, have shown the effectiveness of the proposed control strategy for wind energy systems based on the permanent magnet synchronous generator(PMSG). 展开更多
关键词 Maximum power point tracking permanent magnet synchronous generator(PMSG) sliding mode control wind turbine
下载PDF
Prediction of Short-Term Distributions of Load Extremes of Offshore Wind Turbines 被引量:2
17
作者 王迎光 《China Ocean Engineering》 SCIE EI CSCD 2016年第6期851-866,共16页
This paper proposes a new methodology to select an optimal threshold level to be used in the peak over threshold (POT) method for the prediction of short-term distributions of load extremes of offshore wind turbines... This paper proposes a new methodology to select an optimal threshold level to be used in the peak over threshold (POT) method for the prediction of short-term distributions of load extremes of offshore wind turbines. Such an optimal threshold level is found based on the estimation of the variance-to-mean ratio for the occurrence of peak values, which characterizes the Poisson assumption. A generalized Pareto distribution is then fitted to the extracted peaks over the optimal threshold level and the distribution parameters are estimated by the method of the maximum spacing estimation. This methodology is applied to estimate the short-term distributions of load extremes of the blade bending moment and the tower base bending moment at the mudline of a monopile-supported 5MW offshore wind turbine as an example. The accuracy of the POT method using the optimal threshold level is shown to be better, in terms of the distribution fitting, than that of the POT methods using empirical threshold levels. The comparisons among the short-term extreme response values predicted by using the POT method with the optimal threshold levels and with the empirical threshold levels and by using direct simulation results further substantiate the validity of the proposed new methodology. 展开更多
关键词 extreme responses monopile-supported offshore wind turbine peak over threshold method optimalthreshold level variance-to-mean ratio generalized Pareto distribution maximum spacing estimation
下载PDF
Fractional-Order Control of a Wind Turbine Using Manta Ray Foraging Optimization 被引量:2
18
作者 Hegazy Rezk Mohammed Mazen Alhato +1 位作者 Mohemmed Alhaider Soufiene Bouallègue 《Computers, Materials & Continua》 SCIE EI 2021年第7期185-199,共15页
In this research paper,an improved strategy to enhance the performance of the DC-link voltage loop regulation in a Doubly Fed Induction Generator(DFIG)based wind energy system has been proposed.The proposed strategy u... In this research paper,an improved strategy to enhance the performance of the DC-link voltage loop regulation in a Doubly Fed Induction Generator(DFIG)based wind energy system has been proposed.The proposed strategy used the robust Fractional-Order(FO)Proportional-Integral(PI)control technique.The FOPI control contains a non-integer order which is preferred over the integer-order control owing to its benefits.It offers extra flexibility in design and demonstrates superior outcomes such as high robustness and effectiveness.The optimal gains of the FOPI controller have been determined using a recent Manta Ray Foraging Optimization(MRFO)algorithm.During the optimization process,the FOPI controller’s parameters are assigned to be the decision variables whereas the objective function is the error racking that to be minimized.To prove the superiority of the MRFO algorithm,an empirical comparison study with the homologous particle swarm optimization and genetic algorithm is achieved.The obtained results proved the superiority of the introduced strategy in tracking and control performances against various conditions such as voltage dips and wind speed variation. 展开更多
关键词 Renewable energy MODELING wind turbine doubly fed induction generator fractional order control manta ray foraging optimization
下载PDF
Model of DFIG Wind Farm and Study on Its LVRT Capability 被引量:1
19
作者 He Guo Ding-Zhong Huang +1 位作者 Li-Gang Gu Fang-Yuan Wu 《Journal of Electronic Science and Technology》 CAS 2013年第1期78-83,共6页
As a typical clean and renewable energy, wind power is becoming more and more widely used in electrical industry. However, its characteristics of random and intermittent have brought serious problems to the power syst... As a typical clean and renewable energy, wind power is becoming more and more widely used in electrical industry. However, its characteristics of random and intermittent have brought serious problems to the power system, such as voltage fluctuation and insufficient reactive power. Based on the K-means clustering algorithm, this paper classifies the doubly-fed induction generators (DFIG) according to the operation of propeller pitch angle control. At the same time, to obtain the optimal parameter, advanced particle swarm optimization (PSO) is used. Then the dynamic model of DFIG under the network fault condition is built. What is more, the role that crowbar circuit plays in low voltage ride through (LVRT) is discussed. Finally, simulations in DigSILENT verify the model. 展开更多
关键词 CROWBAR doubly-fed induction generators low voltage ride through MODEL wind turbine.
下载PDF
Dynamic Circulation Control for a Vertical Axis Wind Turbine using Virtual Solidity Matching 被引量:1
20
作者 Jay P. Wilhelm Andrew C. Nix +2 位作者 Chad C. Panther Wade W. Huebsch James E. Smith 《Smart Grid and Renewable Energy》 2017年第4期99-113,共15页
Vertical Axis Wind Turbines (VAWTs) with fixed pitch blades have a limited power capture performance envelope as the Tip Speed Ratio (TSR) changes. Circulation Control (CC) has been proposed and simulated to possibly ... Vertical Axis Wind Turbines (VAWTs) with fixed pitch blades have a limited power capture performance envelope as the Tip Speed Ratio (TSR) changes. Circulation Control (CC) has been proposed and simulated to possibly increase power capture of a VAWT using constant CC jet momentum, but a practical method of minimizing CC usage has yet to be explored. In addition, VAWTs are typically limited in power capture performance either by a maximum peak at a small set of TSR or wide operating TSR at fractions of the peak performance based on the design solidity. Both the reduced jet usage and solidity limitation were addressed by developing a method of dynamically using CC to perform a virtual solidity change. The developed method described within this work used CC to change blade aerodynamics to specifically match a maximum performing static solidity or wake shape at a given TSR. Simulation results using an existing aerodynamics model indicated a significant reduction in the re-quired CC jet momentum compared to a constant CC system along with control over power capture for a CC-VAWT. 展开更多
关键词 CIRCULATION CONTROL Vertical Axis wind turbine VAWT Flow CONTROL SOLIDITY matchING