Microfiltration membrane technology has been widely used in various industries for solid-liquid separation. However, pore clogging remains a persistent challenge. This study employs (CFD) and discrete element method (...Microfiltration membrane technology has been widely used in various industries for solid-liquid separation. However, pore clogging remains a persistent challenge. This study employs (CFD) and discrete element method (DEM) models to enhance our understanding of microfiltration membrane clogging. The models were validated by comparing them to experimental data, demonstrating reasonable consistency. Subsequently, a parametric study was conducted on a cross-flow model, exploring the influence of key parameters on clogging. Findings show that clogging is a complex phenomenon affected by various factors. The mean inlet velocity and transmembrane flux were found to directly impact clogging, while the confinement ratio and cosine of the membrane pore entrance angle had an inverse relationship with it. Two clog types were identified: internal (inside the pore) and external (arching at the pore entrance), with the confinement ratio determining the type. This study introduced a dimensionless number as a quantitative clogging indicator based on transmembrane flux, Reynolds number, filtration time, entrance angle cosine, and confinement ratio. While this hypothesis held true in simulations, future studies should explore variations in clogging indicators, and improved modeling of clogging characteristics. Calibration between numerical and physical times and consideration of particle volume fraction will enhance understanding.展开更多
This paper reports a study on the role of fluid flow pattern and dynamic pressure on the permeate flux through a micro filtration membrane in laboratory scale.For this purpose,a dead-end membrane cell equipped with a ...This paper reports a study on the role of fluid flow pattern and dynamic pressure on the permeate flux through a micro filtration membrane in laboratory scale.For this purpose,a dead-end membrane cell equipped with a marine type impeller was used.The impeller was set to rotate in the clockwise and counter clockwise directions with the same angular velocities in order to illustrate the effect of rotation direction on permeate flux.Consequently, permeate fluxes were measured at various impeller rotational speeds.The computational fluid dynamics(CFD)predicted dynamic pressure was related to the fluxes obtained in the experiments.Using the CFD modeling,it is proven that the change in dynamic pressure upon the membrane surface has direct effect on the permeate flux.展开更多
To understand the adsorption behavior of endocrine disrupting chemicals(EDCs) is important for enhancing the treatment performance and preventing potential secondary pollution caused by EDCs desorption in a microfil...To understand the adsorption behavior of endocrine disrupting chemicals(EDCs) is important for enhancing the treatment performance and preventing potential secondary pollution caused by EDCs desorption in a microfiltration system. The dynamic adsorption of four representative EDCs, namely estriol(E3), 17β-estradiol(E2), 17α-ethynylestradiol(EE2), and 4-nonylphenol(4-NP) in a microfiltration system was investigated using the Thomas' model.The product of the equilibrium constant and the total adsorption capacity of the membrane,Ka, for E3, E2, EE2, and 4-NP were 4.91, 9.78, 15.6, and 826, respectively, strongly correlating with the compound octanol–water partition coefficient(KOW). Adsorption appeared to be enhanced when organic fouling formed on the surface of membrane, indicating the role of an additional adsorption column for EDCs acted by a fouling layer in microfiltration. Results of a comparison between the Ka values for clean membrane and fouled membrane illustrated that the significant contribution made by fouling layers may be attributed to the foulant layer's hydrophobicity(in the case of calcium humate layer) and thickness(in the case of calcium alginate layer). This study provided a novel perspective to quantitatively analyze the dynamic adsorption behavior of trace pollutants in membrane process.展开更多
文摘Microfiltration membrane technology has been widely used in various industries for solid-liquid separation. However, pore clogging remains a persistent challenge. This study employs (CFD) and discrete element method (DEM) models to enhance our understanding of microfiltration membrane clogging. The models were validated by comparing them to experimental data, demonstrating reasonable consistency. Subsequently, a parametric study was conducted on a cross-flow model, exploring the influence of key parameters on clogging. Findings show that clogging is a complex phenomenon affected by various factors. The mean inlet velocity and transmembrane flux were found to directly impact clogging, while the confinement ratio and cosine of the membrane pore entrance angle had an inverse relationship with it. Two clog types were identified: internal (inside the pore) and external (arching at the pore entrance), with the confinement ratio determining the type. This study introduced a dimensionless number as a quantitative clogging indicator based on transmembrane flux, Reynolds number, filtration time, entrance angle cosine, and confinement ratio. While this hypothesis held true in simulations, future studies should explore variations in clogging indicators, and improved modeling of clogging characteristics. Calibration between numerical and physical times and consideration of particle volume fraction will enhance understanding.
文摘This paper reports a study on the role of fluid flow pattern and dynamic pressure on the permeate flux through a micro filtration membrane in laboratory scale.For this purpose,a dead-end membrane cell equipped with a marine type impeller was used.The impeller was set to rotate in the clockwise and counter clockwise directions with the same angular velocities in order to illustrate the effect of rotation direction on permeate flux.Consequently, permeate fluxes were measured at various impeller rotational speeds.The computational fluid dynamics(CFD)predicted dynamic pressure was related to the fluxes obtained in the experiments.Using the CFD modeling,it is proven that the change in dynamic pressure upon the membrane surface has direct effect on the permeate flux.
基金supported by the National Natural Science Foundation of China(No.51678336)the KWEF-AIT Research Grant,the President Fund for Science and Education Fusion of UCAS(No.Y552022Y00)the special fund of SKLECE,Chinese Academy of Sciences(No.KF2016-19)
文摘To understand the adsorption behavior of endocrine disrupting chemicals(EDCs) is important for enhancing the treatment performance and preventing potential secondary pollution caused by EDCs desorption in a microfiltration system. The dynamic adsorption of four representative EDCs, namely estriol(E3), 17β-estradiol(E2), 17α-ethynylestradiol(EE2), and 4-nonylphenol(4-NP) in a microfiltration system was investigated using the Thomas' model.The product of the equilibrium constant and the total adsorption capacity of the membrane,Ka, for E3, E2, EE2, and 4-NP were 4.91, 9.78, 15.6, and 826, respectively, strongly correlating with the compound octanol–water partition coefficient(KOW). Adsorption appeared to be enhanced when organic fouling formed on the surface of membrane, indicating the role of an additional adsorption column for EDCs acted by a fouling layer in microfiltration. Results of a comparison between the Ka values for clean membrane and fouled membrane illustrated that the significant contribution made by fouling layers may be attributed to the foulant layer's hydrophobicity(in the case of calcium humate layer) and thickness(in the case of calcium alginate layer). This study provided a novel perspective to quantitatively analyze the dynamic adsorption behavior of trace pollutants in membrane process.
文摘以陶瓷膜管为基质,研究了高岭土动态膜的制备过程.实验以高岭土为动态膜预涂材料,采用错流操作对膜管进行涂膜,通过记录和分析涂膜过程中的渗透液通量和测定在此过程中涂上的高岭土的量随时间的变化,研究了高岭土粒径、涂膜液浓度、跨膜压力、错流速度和涂膜时间对涂膜效果及清水通量的影响,对涂膜过程有了较好的认识,并得出最佳涂膜条件为:涂膜液质量浓度0.3 g/L、跨膜压力0.2 MPa、错流速度0.5 m/s及涂膜时间10 min.