Linguistic single-valued neutrosophic set(LSVNS)is a more reliable tool,which is designed to handle the uncertainties of the situations involving the qualitative data.In the present manuscript,we introduce some power ...Linguistic single-valued neutrosophic set(LSVNS)is a more reliable tool,which is designed to handle the uncertainties of the situations involving the qualitative data.In the present manuscript,we introduce some power aggregation operators(AOs)for the LSVNSs,whose purpose is to diminish the influence of inevitable arguments about the decision-making process.For it,first we develop some averaging power operators,namely,linguistic single-valued neutrosophic(LSVN)power averaging,weighted average,ordered weighted average,and hybrid averaging AOs along with their desirable properties.Further,we extend it to the geometric power AOs for LSVNSs.Based on the proposed work;an approach to solve the group decision-making problems is given along with the numerical example.Finally,a comparative study and the validity tests are present to discuss the reliability of the proposed operators.展开更多
The setting values of thresholds for fault feature parameters are critical in all kinds of protection schemes.When the detected feature parameter value exceeds the setting value,the protection will trip.However,the se...The setting values of thresholds for fault feature parameters are critical in all kinds of protection schemes.When the detected feature parameter value exceeds the setting value,the protection will trip.However,the setting value based conventional protection schemes sometimes cannot satisfy the protection requirements of neutral ineffectively earthed power systems(NIEPS)due to wide variations in operating conditions and the complexities of fault cases.In this paper,a novel single phase grounding fault protection scheme without threshold setting is proposed.The fault detection is achieved based on operating states rather than setting values.A fuzzy c-means algorithm is used to divide the operating state of the protected feeder into non-fault states and fault states.The cluster center of each state is then obtained by classifying the historical feature samples of the protected feeder extracted under various operating conditions into their corresponding states in a constructed multi-dimensional fault feature space.The distances between the detected feature samples and the cluster centers of the non-fault and the fault states are calculated.If the distance to the fault state is shorter than that to the non-fault state,a fault is detected.Otherwise,the feeder is considered normal.A PSCAD/EMTDC simulator is used to simulate a 35 kV NIEPS under various operating conditions,non-linear loads,and complex fault cases.Results show that the proposed single phase grounding fault protection scheme without threshold setting can protect the system correctly under all kinds of faults.展开更多
文摘Linguistic single-valued neutrosophic set(LSVNS)is a more reliable tool,which is designed to handle the uncertainties of the situations involving the qualitative data.In the present manuscript,we introduce some power aggregation operators(AOs)for the LSVNSs,whose purpose is to diminish the influence of inevitable arguments about the decision-making process.For it,first we develop some averaging power operators,namely,linguistic single-valued neutrosophic(LSVN)power averaging,weighted average,ordered weighted average,and hybrid averaging AOs along with their desirable properties.Further,we extend it to the geometric power AOs for LSVNSs.Based on the proposed work;an approach to solve the group decision-making problems is given along with the numerical example.Finally,a comparative study and the validity tests are present to discuss the reliability of the proposed operators.
基金supported in part by National Natural Science Foundation of China under Grant 61233008 and Grant 51277014.
文摘The setting values of thresholds for fault feature parameters are critical in all kinds of protection schemes.When the detected feature parameter value exceeds the setting value,the protection will trip.However,the setting value based conventional protection schemes sometimes cannot satisfy the protection requirements of neutral ineffectively earthed power systems(NIEPS)due to wide variations in operating conditions and the complexities of fault cases.In this paper,a novel single phase grounding fault protection scheme without threshold setting is proposed.The fault detection is achieved based on operating states rather than setting values.A fuzzy c-means algorithm is used to divide the operating state of the protected feeder into non-fault states and fault states.The cluster center of each state is then obtained by classifying the historical feature samples of the protected feeder extracted under various operating conditions into their corresponding states in a constructed multi-dimensional fault feature space.The distances between the detected feature samples and the cluster centers of the non-fault and the fault states are calculated.If the distance to the fault state is shorter than that to the non-fault state,a fault is detected.Otherwise,the feeder is considered normal.A PSCAD/EMTDC simulator is used to simulate a 35 kV NIEPS under various operating conditions,non-linear loads,and complex fault cases.Results show that the proposed single phase grounding fault protection scheme without threshold setting can protect the system correctly under all kinds of faults.