The reactivity worth measurement system for control rods of the TRIGA MARK-II research reactor of Bangladesh has been design and developed. The theory of the kinetic technique of measuring reactivity has been used by ...The reactivity worth measurement system for control rods of the TRIGA MARK-II research reactor of Bangladesh has been design and developed. The theory of the kinetic technique of measuring reactivity has been used by this measurement system. The system comprises of indigenous hardware and software for online acquisition of neutron flux signals from reactor console and then computes the reactivity worth accordingly. Here for the TRIGA MARK-II research reactor, the reactivity measurement system was implemented with a dedicated circuit assembly and a conventional personal computer. A high-level Visual Basic real-time programming has been developed for data acquisition, reactivity calculation, online display (numerically as well as graphically), saving data, etc. To measure reactivity worth of TRIGA reactor control rods the rod drop experimental technique has been adopted. The results of tests experiments, carried out with the rod drop method for measuring various reactivity worth of control rods have been presented in the paper. A comparison between this results with the results using period method and that of computation method, demonstrated that the response of this reactivity measurement system is fast enough to monitor and measure the safety-related reactivity and power excursions in the reactor.展开更多
Control rod is used to change the power in nuclear reactor.?Certainly, the core at any moment can be made subcritical condition and shut downs when occurring?to emergency instance in the core. The rod is grouped based...Control rod is used to change the power in nuclear reactor.?Certainly, the core at any moment can be made subcritical condition and shut downs when occurring?to emergency instance in the core. The rod is grouped based?on their function and located at different places in the core where their feature is maximized.?Two methods of control rod calibration are the asymptotic period method and the rod-drop method, which were applied in this experiment. In the first method, the reactor is made supcritical by inserting the control rod to be calibrated a certain level. The rod drop method is to determine the subcritical;at the critical state, the rod to be calibrated is dropped into the core, and the resulting decay of neutron flux is observed and related to the reactivity. In this paper, the regulating rod will be calibrated according to the reactivity in OPR-1000 that corresponds to a certain control rod insert or withdraw, and the reactivity in power reactor depends?on the integral and differential control rod group too. The core simulator OPR1000 is used to test those methods.展开更多
The electrical performance including breakdown voltage and turn-off speed of SOI-LIGBT is improved by incorporating a resistive field plate (RFP) and a p-MOSFET.The p-MOSFET is controlled by a signal detected from a p...The electrical performance including breakdown voltage and turn-off speed of SOI-LIGBT is improved by incorporating a resistive field plate (RFP) and a p-MOSFET.The p-MOSFET is controlled by a signal detected from a point of the RFP.During the turning-off of the IGBT,the p-MOSFET is turned on,which provides a channel for the excessive carriers to flow out of the drift region and prevents the carriers from being injected into the drift region.At the same time,the electric field affected by the RFP makes the excessive carriers flow through a wider region,which almost eliminates the second phase of the turning-off of the SOI-LIGBT caused by the substrate bias.Faster turn-off speed is achieved by above two factors.During the on state of the IGBT,the p-MOSFET is off,which leads to an on-state performance like normal one.At least,the increase of the breakdown voltage for 25% and the decrease of the turn-off time for 65% can be achieved by this structure as can be verified by the numerical simulation results.展开更多
IGBT with high switching speed is described based on the dynamic controlled anode- short,which incorpo- rates a normally- on,p- MOSFET controlled by the anode voltage indirectly.This device works just as normal when ...IGBT with high switching speed is described based on the dynamic controlled anode- short,which incorpo- rates a normally- on,p- MOSFET controlled by the anode voltage indirectly.This device works just as normal when it is in on- state since the channel of the p- MOSFET is pinched- off.During the course of turning off,the channel of the p- MOSFET will prevent the injection of m inorities and introduce an extra access for the carriers to flow to the anode directly,which m akes the IGBT reach its off- state in a shorter time.The simulation results prove that the new structure can reduce the turn- off time by m ore than75 % compared with the normal one under the same break- down voltage and on- state perform ance.Only two more resistors are needed when using this structure,and the re- quirement of the drive circuits is just the sam e as normal.展开更多
紧急停堆棒落棒时间是影响反应堆安全特性的重要参数,以2 MW钍基熔盐堆为研究对象,采用RELAP5-TMSR(Reactor Excursion and Leak Analysis Program-Thorium Molten Salt Reactor)程序,建立熔盐堆系统的瞬态行为分析模型,对控制棒提棒速...紧急停堆棒落棒时间是影响反应堆安全特性的重要参数,以2 MW钍基熔盐堆为研究对象,采用RELAP5-TMSR(Reactor Excursion and Leak Analysis Program-Thorium Molten Salt Reactor)程序,建立熔盐堆系统的瞬态行为分析模型,对控制棒提棒速度的敏感性进行分析,并重点分析探索紧急停堆棒落棒时间对熔盐堆反应性引入瞬态后果的影响规律。结果表明:即使紧急停堆棒落棒时间达到10 min,哈氏合金的最高温度也仅为708.2℃,燃料盐最高温度为709.2℃,均低于安全允许限值,表明该熔盐堆具有良好的应对反应性引入事件的能力。展开更多
文摘The reactivity worth measurement system for control rods of the TRIGA MARK-II research reactor of Bangladesh has been design and developed. The theory of the kinetic technique of measuring reactivity has been used by this measurement system. The system comprises of indigenous hardware and software for online acquisition of neutron flux signals from reactor console and then computes the reactivity worth accordingly. Here for the TRIGA MARK-II research reactor, the reactivity measurement system was implemented with a dedicated circuit assembly and a conventional personal computer. A high-level Visual Basic real-time programming has been developed for data acquisition, reactivity calculation, online display (numerically as well as graphically), saving data, etc. To measure reactivity worth of TRIGA reactor control rods the rod drop experimental technique has been adopted. The results of tests experiments, carried out with the rod drop method for measuring various reactivity worth of control rods have been presented in the paper. A comparison between this results with the results using period method and that of computation method, demonstrated that the response of this reactivity measurement system is fast enough to monitor and measure the safety-related reactivity and power excursions in the reactor.
文摘Control rod is used to change the power in nuclear reactor.?Certainly, the core at any moment can be made subcritical condition and shut downs when occurring?to emergency instance in the core. The rod is grouped based?on their function and located at different places in the core where their feature is maximized.?Two methods of control rod calibration are the asymptotic period method and the rod-drop method, which were applied in this experiment. In the first method, the reactor is made supcritical by inserting the control rod to be calibrated a certain level. The rod drop method is to determine the subcritical;at the critical state, the rod to be calibrated is dropped into the core, and the resulting decay of neutron flux is observed and related to the reactivity. In this paper, the regulating rod will be calibrated according to the reactivity in OPR-1000 that corresponds to a certain control rod insert or withdraw, and the reactivity in power reactor depends?on the integral and differential control rod group too. The core simulator OPR1000 is used to test those methods.
文摘The electrical performance including breakdown voltage and turn-off speed of SOI-LIGBT is improved by incorporating a resistive field plate (RFP) and a p-MOSFET.The p-MOSFET is controlled by a signal detected from a point of the RFP.During the turning-off of the IGBT,the p-MOSFET is turned on,which provides a channel for the excessive carriers to flow out of the drift region and prevents the carriers from being injected into the drift region.At the same time,the electric field affected by the RFP makes the excessive carriers flow through a wider region,which almost eliminates the second phase of the turning-off of the SOI-LIGBT caused by the substrate bias.Faster turn-off speed is achieved by above two factors.During the on state of the IGBT,the p-MOSFET is off,which leads to an on-state performance like normal one.At least,the increase of the breakdown voltage for 25% and the decrease of the turn-off time for 65% can be achieved by this structure as can be verified by the numerical simulation results.
文摘IGBT with high switching speed is described based on the dynamic controlled anode- short,which incorpo- rates a normally- on,p- MOSFET controlled by the anode voltage indirectly.This device works just as normal when it is in on- state since the channel of the p- MOSFET is pinched- off.During the course of turning off,the channel of the p- MOSFET will prevent the injection of m inorities and introduce an extra access for the carriers to flow to the anode directly,which m akes the IGBT reach its off- state in a shorter time.The simulation results prove that the new structure can reduce the turn- off time by m ore than75 % compared with the normal one under the same break- down voltage and on- state perform ance.Only two more resistors are needed when using this structure,and the re- quirement of the drive circuits is just the sam e as normal.