期刊文献+
共找到65,456篇文章
< 1 2 250 >
每页显示 20 50 100
Study on the Influence of Setting Parameters of Tunnel Centralized Smoke Extraction System on Fire Smoke Flow and Temperature Decay
1
作者 Zhisheng Xu SohailMahmood Zihan Yu 《Frontiers in Heat and Mass Transfer》 EI 2024年第3期791-816,共26页
The centralized smoke exhaust system of shield tunnel is an important determinant for tunnel fire safety,and the use of different design parameters of the tunnel smoke exhaust system will affect the smoke exhaust effe... The centralized smoke exhaust system of shield tunnel is an important determinant for tunnel fire safety,and the use of different design parameters of the tunnel smoke exhaust system will affect the smoke exhaust effect in the tunnel,and the influence of different design parameters on the smoke exhaust effect and temperature attenuation of the tunnel can help engineers in designing a more effective centralized smoke exhaust system for the tunnel.In this paper,the Fire Dynamic Simulator(FDS)is utilized to examine smoke exhaust vent settings for a centralized exhaust system in shield tunnel with both flat and sloped conditions,including slopes of+4.5%and−4.5%,under a 30MWfire power with a 150m^(3)/s smoke exhaust rate.The results suggest that maintaining a vent spacing of 60m and a vent size of 4.0 m×1.5 m is a reasonable configuration for centralized smoke exhaust systems in both flat and slope shield tunnels.This choice helpsminimize construction costs and prevent excessive smoke accumulation.It also promotes favorable conditions for maintaining temperature distribution at 2-m height,visibility,smoke spread distance,and temperature below the ceiling,all below the threshold values,while ensuring high smoke extraction efficiency.However,in the slope section,the chimney effect can disrupt exhaust efficiency,visibility,ceiling temperature,and temperature distribution at a height of 2 m.Employing different opening methods,such as having 2 vents up and 4 vents down in a+4.5%slope and 4 vents up and 2 vents down in a−4.5%slope,can help mitigate these effects.Furthermore,the temperature decay formula for shield tunnels follows a bi-exponential decay pattern,and different design parameters of centralized smoke exhaust systems have minimal effects on temperature decay in shield tunnels. 展开更多
关键词 smoke exhaust setting smoke spread efficiency temperature decay
下载PDF
Lung ultrasound score evaluation of the effect of pressure-controlled ventilation volume-guaranteed on patients undergoing laparoscopicassisted radical gastrectomy
2
作者 Jian Tan Cheng-Ming Bao Xiao-Yuan Chen 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第6期1717-1725,共9页
BACKGROUND Laparoscopic-assisted radical gastrectomy(LARG)is the standard treatment for early-stage gastric carcinoma(GC).However,the negative impact of this proce-dure on respiratory function requires the optimized i... BACKGROUND Laparoscopic-assisted radical gastrectomy(LARG)is the standard treatment for early-stage gastric carcinoma(GC).However,the negative impact of this proce-dure on respiratory function requires the optimized intraoperative management of patients in terms of ventilation.AIM To investigate the influence of pressure-controlled ventilation volume-guaranteed(PCV-VG)and volume-controlled ventilation(VCV)on blood gas analysis and pulmonary ventilation in patients undergoing LARG for GC based on the lung ultrasound score(LUS).METHODS The study included 103 patients with GC undergoing LARG from May 2020 to May 2023,with 52 cases undergoing PCV-VG(research group)and 51 cases undergoing VCV(control group).LUS were recorded at the time of entering the operating room(T0),20 minutes after anesthesia with endotracheal intubation(T1),30 minutes after artificial pneumoperitoneum(PP)establishment(T2),and 15 minutes after endotracheal tube removal(T5).For blood gas analysis,arterial partial pressure of oxygen(PaO_(2))and partial pressure of carbon dioxide(PaCO_(2))were observed.Peak airway pressure(P_(peak)),plateau pressure(Pplat),mean airway pressure(P_(mean)),and dynamic pulmonary compliance(C_(dyn))were recorded at T1 and T2,1 hour after PP establishment(T3),and at the end of the operation(T4).Postoperative pulmonary complications(PPCs)were recorded.Pre-and postoperative serum interleukin(IL)-1β,IL-6,and tumor necrosis factor-α(TNF-α)were measured by enzyme-linked immunosorbent assay.RESULTS Compared with those at T0,the whole,anterior,lateral,posterior,upper,lower,left,and right lung LUS of the research group were significantly reduced at T1,T2,and T5;in the control group,the LUS of the whole and partial lung regions(posterior,lower,and right lung)decreased significantly at T2,while at T5,the LUS of the whole and some regions(lateral,lower,and left lung)increased significantly.In comparison with the control group,the whole and regional LUS of the research group were reduced at T1,T2,and T5,with an increase in PaO_(2),decrease in PaCO_(2),reduction in P_(peak) at T1 to T4,increase in P_(mean) and C_(dyn),and decrease in Pplat at T4,all significant.The research group showed a significantly lower incidence of PPCs than the control group within 3 days postoperatively.Postoperative IL-1β,IL-6,and TNF-αsignificantly increased in both groups,with even higher levels in the control group.CONCLUSION LUS can indicate intraoperative non-uniformity and postural changes in pulmonary ventilation under PCV-VG and VCV.Under the lung protective ventilation strategy,the PCV-VG mode more significantly improved intraop-erative lung ventilation in patients undergoing LARG for GC and reduced lung injury-related cytokine production,thereby alleviating lung injury. 展开更多
关键词 Lung ultrasound score Pressure-controlled ventilation volume-guaranteed Laparoscopic-assisted radical gastrectomy Blood gas analysis indexes Pulmonary ventilation
下载PDF
Study of the Influence of the Distance between Smoke Outlets and Fire Source on Smoke Flow Characteristics in Tunnel Fires
3
作者 Liang Yi Zhiqiang Lei +2 位作者 Zhisheng Xu Yaolong Yin Houlin Ying 《Frontiers in Heat and Mass Transfer》 EI 2024年第4期977-996,共20页
This paper explores the smoke flow characteristics in tunnel fires,giving a particular emphasis on the effects of different distances between the smoke outlets and the fire source.It examines the smoke behavior under ... This paper explores the smoke flow characteristics in tunnel fires,giving a particular emphasis on the effects of different distances between the smoke outlets and the fire source.It examines the smoke behavior under different conditions,including variations in heat release rates,exhaust volumetric flow rates,spacing between smoke outlets,and the longitudinal fire source positions.Results indicate that altering the fire source positions and the smoke outlets in the tunnel leads to variations in the properties of smoke flow both the fire source upstream and downstream;the distance between fire source and smoke outlet increases gradually,airflow rate decreases initially and eventually reaches a stable state.Similarly,smoke mass flow rate exhibits an increasing trend that eventually reaches a stable state.Moreover,the heat exchange between the tunnel walls and hot smoke increases as the smoke outlet moves further away from the fire source.This interaction leads to a reduction in the heat exhaust coefficient and a decrease in the distance the smoke spreads.This study investigates the impact of altering the relative longitudinal fire source positions and smoke outlet on smoke flow characteristics by numerical simulation.A theoretical analytical method is used to give a predictive model for the heat exhaust coefficient and the smoke spreading distance.This research can support the theory and technical process of tunnel smoke exhaust prevention and control. 展开更多
关键词 Tunnel fire numerical simulation centralized smoke exhaust heat exhaust coefficient smoke spreading distance
下载PDF
Study on Temperature Distribution and Smoke Spreading Behavior of Different Fire Source Locations in the UnderwaterW-Shaped Island-Crossing Tunnel
4
作者 Zhisheng Xu Juan Wang +1 位作者 Zihan Yu Jiaming Zhao 《Frontiers in Heat and Mass Transfer》 EI 2024年第4期1129-1151,共23页
Called island-crossing tunnels,some specific underwater tunneling projects face constraints imposed by geological and water conditions,necessitating their passage through artificial or natural islands.The longitudinal... Called island-crossing tunnels,some specific underwater tunneling projects face constraints imposed by geological and water conditions,necessitating their passage through artificial or natural islands.The longitudinal of the tunnel follows aW-shaped distribution.The congestion situation does not allowfor immediate longitudinal smoke exhaust at the early stage of the fire,and the natural spread of smoke is complicated.An exhaustive investigation was carried out to analyze the smoke behaviors during a fire incident,employing the fire dynamics software FDS,considering five slopes and four fire locations.The simulation results reveal that the layer of high-temperature smoke becomes thicker as one gets closer to the fire source.The thermal pressure difference significantly impacts the temperature distribution within the tunnel and the distance of smoke spread.The value of the thermal pressure difference is significantly affected by changes in slope.It reaches a maximum of 157 Pa at a 5%slope,while it is only 41 Pa at a 1%slope when the fire occurs at the V-point.Fire hazards vary across locations within the W-shaped tunnel,necessitating separate consideration of the V-point and inverted V-point fire characteristics.The mass flow rate in small and large slope tunnels shows different decay rates due to variations in the main forces acting on the movement.Hence,two equations have been developed to predict the smoke mass flow rate,indicating a nonlinear relationship with the tunnel slope and the distance fromthe fire source.The tunnel slope inversely affects the smoke mass flowrate at the same location.The results can be utilized as a reference for conducting evacuation operations and aiding rescues during aW-shaped tunnel fire. 展开更多
关键词 Tunnel fire tilted tunnel smoke movement temperature distribution
下载PDF
Inhibition of the NF-κB Signaling Pathway Improves Cigarette Mainstream Smoke-Induced Lung Injury and Gut Microbiota Disturbance
5
作者 Hong Huang Shengjie Li +6 位作者 Lifang Zeng Yan Zhang Ying Chen Yanbing Ma Jing Wei Changwei Zou Tingtao Chen 《Biomedical and Environmental Sciences》 SCIE CAS CSCD 2024年第6期676-681,共6页
Currently,cigarette smoke(CS)remains a major contributor to disease morbidity and mortality.CS can be divided into cigarette mainstream smoke(CMS)and side-stream smoke,depending on where it is produced by burning toba... Currently,cigarette smoke(CS)remains a major contributor to disease morbidity and mortality.CS can be divided into cigarette mainstream smoke(CMS)and side-stream smoke,depending on where it is produced by burning tobacco^([1]).CMS is inhaled by smokers from the filter end during cigarette combustion and is strongly associated with the development of several diseases^([2-4]). 展开更多
关键词 smoke CMS CIGARETTE
下载PDF
Small-scale fire tests in the underwater tunnel section model with new sidewall smoke extraction
6
作者 Shunyu Yue Ruifeng Miao +2 位作者 Huihang Cheng Maohua Zhong Xiujun Yang 《Deep Underground Science and Engineering》 2024年第2期247-254,共8页
The Shenzhen–Zhongshan Bridge is a 24‐km‐long bridge and tunnel system,including a 6.8-km-long super cross section subsea tunnel.To solve the smoke exhaust problem of a super large cross-section subsea tunnel,the t... The Shenzhen–Zhongshan Bridge is a 24‐km‐long bridge and tunnel system,including a 6.8-km-long super cross section subsea tunnel.To solve the smoke exhaust problem of a super large cross-section subsea tunnel,the tunnel has a new smoke exhaust system that combines a horizontal smoke exhaust cross section at the top and sidewall smoke exhaust holes.In order to evaluate the potential fire hazards of this type of tunnel,a 1:30 tunnel model was established and 140 smallscale experiments on underwater tunnel fires were conducted.By changing the fire power,fire location,and fan operation mode,different scenarios of submarine immersed tunnel fire were simulated and the related key parameters such as fire smoke diffusion behavior and smoke temperature distribution were studied.On this basis,the optimal smoke control strategy was proposed for different fire scenarios.The research results indicate that the new smoke exhaust system can fully utilize the smoke flow characteristics,significantly improve smoke exhaust efficiency,and increase available evacuation time,thus further enhancing the fire safety of super large cross-section subsea tunnels. 展开更多
关键词 sidewall smoke extraction system small‐scale fire tests smoke control
下载PDF
Influences of the Fresh Air Volume on the Removal of Cough-Released Droplets in a Passenger Car of a High-Speed Train Using CFD
7
作者 Jun Xu Kai Bi +7 位作者 Yibin Lu TiantianWang Hang Zhang Zeyuan Zheng Fushan Shi Yaxin Zheng Xiaoying Li Jingping Yang 《Computer Modeling in Engineering & Sciences》 SCIE EI 2024年第3期2727-2748,共22页
The spread and removal of pollution sources,namely,cough-released droplets in three different areas(front,middle,and rear areas)of a fully-loaded passenger car in a high-speed train under different fresh air flow volu... The spread and removal of pollution sources,namely,cough-released droplets in three different areas(front,middle,and rear areas)of a fully-loaded passenger car in a high-speed train under different fresh air flow volume were studied using computational fluid dynamics(CFD)method.In addition,the structure of indoor flow fields was also analysed.The results show that the large eddies are more stable and flow faster in the air supply under Mode 2(fresh air volume:2200m3/h)compared to Mode 1(fresh air volume:1100m3/h).By analysing the spreading process of droplets sprayed at different locations in the passenger car and with different particle sizes,the removal trends for droplets are found to be similar under the two air supply modes.However,when increasing the fresh air flow volume,the droplets in the middle and front areas of the passenger car are removed faster.When the droplets had dispersed for 60s,Mode 2 exhibited a removal rate approximately 1%–3%higher than Mode 1 for small and medium-sized droplets with diameters of 10 and 50μm.While those in the rear area,the situation is reversed,with Mode 1 slightly surpassing Mode 2 by 1%–3%.For large droplets with a diameter of 100μm,both modes achieved a removal rate of over 96%in all three regions at the 60 s.The results can provide guidance for air supply modes of passenger cars of high-speed trains,thus suppressing the spread of virus-carrying droplets and reducing the risk of viral infection among passengers. 展开更多
关键词 Cough-released pollutants CFD ventilation inside trains supply air volume
下载PDF
Noninvasive Ventilation Interfaces in the Treatment of Acute Respiratory Insufficiency: A Critical Review
8
作者 Andréa Nóbrega Cirino Nogueira Chakira Torres Lima +3 位作者 Renata dos Santos Vasconcelos Suzy Maria Montenegro Pontes Arnaldo Aires Peixoto Junior Renan Magalhães Montenegro Junior 《Open Journal of Emergency Medicine》 2024年第3期95-103,共9页
Background: Noninvasive ventilation (NIV) is an important therapeutic modality for the treatment of acute respiratory failure (ARF). In this review, we critically analyze randomized controlled trials on the most used ... Background: Noninvasive ventilation (NIV) is an important therapeutic modality for the treatment of acute respiratory failure (ARF). In this review, we critically analyze randomized controlled trials on the most used NIV interfaces in the treatments of ARF. Methods: The searches were conducted in the Medline, Lilacs, PubMed, Cochrane, and Pedro databases from June to November 2021. The inclusion criteria were Randomized clinical trials (RCTs) published from 2016 to 2021 in Portuguese, Spanish, or English and involving adults (aged ≥ 18 years). The eligibility criteria for article selection were based on the PICO strategy: Population—Adults with ARF;Intervention—NIV Therapy;Comparison—Conventional oxygen therapy, high-flow nasal cannula (HFNC) oxygen therapy, or NIV;Outcome—improvement in ARF. The search for articles and the implementation of the inclusion criteria were independently conducted by two researchers. Results: Seven scientific articles involving 574 adults with ARF due to various causes, such as chest trauma, decompensated heart failure, coronavirus disease 2019 (COVID-19), and postoperative period, among others, were included. The interfaces cited in the studies included an oronasal mask, nasal mask, full-face mask, and helmet. In addition, some favorable outcomes related to NIV were reported in the studies, such as a reduction in the rate of orotracheal intubation and shorter length of stay in the ICU. Conclusions: The most cited interfaces in the treatment of ARF were the oronasal mask and the helmet. 展开更多
关键词 Noninvasive ventilation Respiratory Insufficiency RESPIRATION Artificial Continuous Positive Airway Pressure
下载PDF
Unveiling the dynamic role of innate and adaptive immune cells in COPD pathogenesis induced by cigarette smoke
9
作者 Dur E Maknoon Razia Syed Sib Tul Hassan Shah Tabish Faheem 《Life Research》 2024年第4期29-41,共13页
Chronic obstructive pulmonary disease(COPD)is a multifaceted syndrome characterized by a dysregulated inflammatory cascade within the respiratory system,primarily triggered by exposure to harmful particles and gases,n... Chronic obstructive pulmonary disease(COPD)is a multifaceted syndrome characterized by a dysregulated inflammatory cascade within the respiratory system,primarily triggered by exposure to harmful particles and gases,notably from cigarette smoke.This inflammatory response is orchestrated by innate immune cells like macrophages and epithelial cells,which recognize danger signals released from damaged cells.Prolonged inflammation prompts an adaptive immune reaction mediated by dendritic cells,culminating in the formation of lymphoid follicles and involving a complex interplay of T and B cells,as well as cytotoxic activity.Additionally,both viral and bacterial infections exacerbate COPD by further igniting inflammatory pathways,perpetuating the chronic inflammatory state.This comprehensive review encapsulates the intricate interplay between innate and adaptive immunity in COPD,with a particular focus on the role of cigarette smoke in its pathogenesis and potential therapeutic targets. 展开更多
关键词 chronic obstructive pulmonary disease innate immunity adaptive immunity cigarette smoke inflammation oxidative stress protease-antiprotease imbalance
下载PDF
The Analysis of Human Behaviour and Evacuation in a Fire Situation in a Building for Higher Education
10
作者 Dan Diaconu-Şotropa 《Journal of Civil Engineering and Architecture》 2024年第2期86-91,共6页
The paper presents the analysis of a human evacuation from a higher education building located in Iassy,Romania,by means of engineering techniques to approach fire safety.Because in Romania(as in other European countr... The paper presents the analysis of a human evacuation from a higher education building located in Iassy,Romania,by means of engineering techniques to approach fire safety.Because in Romania(as in other European countries)fire safety design of buildings is prescriptive and not performance-based,a fire safety engineering approach arouse great interest in many countries such as the U.S.A.,Australia,New Zealand,England,Sweden,Finland,etc.This paper is based on the assumption of starting a fire in the space of a hall for festivities,located on the ground floor of the building,near two human evacuation routes;We consider two building evacuation scenarios:two exits and,respectively,just one exit(assuming that the second would be accidentally blocked). 展开更多
关键词 CFD(computational fluid dynamics) FDS(fire dynamics simulator) fire safety engineering smoke human behaviour fire simulation educational building
下载PDF
Analysis of the Effect of Non-Invasive Positive Pressure Ventilation in Emergency Treatment of Severe Bronchial Asthma with Respiratory Failure
11
作者 Hua Liu 《Journal of Clinical and Nursing Research》 2024年第6期58-63,共6页
Objective:This study aims to evaluate the clinical efficacy of non-invasive positive pressure ventilation(NIPPV)in patients with severe bronchial asthma combined with respiratory failure.Methods:90 patients with sever... Objective:This study aims to evaluate the clinical efficacy of non-invasive positive pressure ventilation(NIPPV)in patients with severe bronchial asthma combined with respiratory failure.Methods:90 patients with severe bronchial asthma combined with respiratory failure between September 2022 and December 2023 were selected for the study and randomly divided into the experimental group(NIPPV-assisted treatment)and the control group.The differences between the two groups were compared in terms of total effective rate of treatment,days of clinical symptom disappearance,days of hospitalization,lung function indexes,incidence of adverse reactions,and quality of life.Results:Patients in the experimental group had a significantly higher total effective rate of treatment(97.78%)than the control group(75.56%).In terms of pulmonary function indexes,patients in the experimental group showed significant improvement after treatment,especially the increase in forced expiratory volume and forced vital capacity,while these improvements were not as obvious in the control group.In addition,the incidence of adverse reactions was significantly lower in the experimental group than in the control group,suggesting that the application of NIPPV is relatively safe.Quality of life assessment also showed that patients in the experimental group had significantly better quality of life than the control group after treatment.Conclusion:This study demonstrated the effectiveness of NIPPV as an adjunctive treatment for severe bronchial asthma combined with respiratory failure.NIPPV can improve lung function,reduce the incidence of adverse effects,increase the overall effectiveness of the treatment,and contribute to the improvement of patients'quality of life.Therefore,NIPPV should be regarded as an effective and safe treatment in clinical management,especially in patients with severe bronchial asthma combined with respiratory failure,where its application has potential clinical significance. 展开更多
关键词 Non-invasive positive pressure ventilation Adjunctive therapy Respiratory failure Severe bronchial asthma combined with respiratory failure Outcome assessment
下载PDF
Simulation of smoke flow and longitudinal ventilation in tunnel fire 被引量:3
12
作者 杨高尚 安永林 +1 位作者 彭立敏 张进华 《中国有色金属学会会刊:英文版》 EI CSCD 2006年第3期741-746,共6页
Understanding the characteristics of smoke flow in tunnel fire is very important for tunnel safety. The characteristics of tunnel fire were analyzed. The smoke development in different situations of an engineering exa... Understanding the characteristics of smoke flow in tunnel fire is very important for tunnel safety. The characteristics of tunnel fire were analyzed. The smoke development in different situations of an engineering example was simulated using commercial CFD software PHOENICS 3.5 by field modeling method. The spreading rules and characteristics of concentration field and temperature field of smoke flow with different longitudinal ventilation speeds were studied, which may provide the theoretical background for evacuation design in tunnel fire. The effective measures of fire rescue and crowd evacuation were also described. 展开更多
关键词 隧道安全 隧道火灾 烟尘流动 纵向通风 模拟
下载PDF
FDS analysis of smoke spreading in the tunnel with flue under fire 被引量:2
13
作者 LI Yan-ling LONG Xin-feng LIANG Ping 《Journal of Chemistry and Chemical Engineering》 2009年第4期39-43,52,共6页
Based on a new type of tunnel configuration model with flue in the top of it, the paper simulated the smoke pervasion when fire happens in this type of tunnel by FDS. The results show that the setting up of the flue o... Based on a new type of tunnel configuration model with flue in the top of it, the paper simulated the smoke pervasion when fire happens in this type of tunnel by FDS. The results show that the setting up of the flue outlet reduces the backing up distance of combustion smoke, and the distance of people fleeing is also shortened. But under this condition the smoke density inside and outside of the two flue outlet increases evidently. However, when the exhausted fans are designed at smoking outlet, the smoke movement is accelerated and almost moved into the upper space. This configuration makes the fire smoke density outside of the flue outlet reduced greatly. When the exhausted velocity increased up to a certain critical level, the smoke concentration outside of the flue outlet will reduce at the value which is no harmonious to people's life. This situation will offer a relatively safe space for people fleeing, and fire rescuing can also be carried out from two directions. Therefore, this tunnel configuration mentioned in this article give a new reference mode for personnel flee, fire rescuing and tunnel maintenance. 展开更多
关键词 FDS fire flue outlet smoke density exhausted velocity
下载PDF
Respiratory Volume Monitoring to Assess the Effect of Airway Maneuvers on Ventilation during Upper Endoscopy 被引量:1
14
作者 Katherine Holley Donald Mathews +2 位作者 Diane Ladd Lisa Campana Howard Schapiro 《Open Journal of Anesthesiology》 2014年第11期281-290,共10页
Introduction: Propofol use during endoscopic procedures has become increasingly popular and assessing and maintaining airway patency is a significant challenge. Anesthesiologists often use airway maneuvers to maintain... Introduction: Propofol use during endoscopic procedures has become increasingly popular and assessing and maintaining airway patency is a significant challenge. Anesthesiologists often use airway maneuvers to maintain airway patency and ventilation during procedural sedation. A novel, non-invasive, Respiratory Volume Monitor (RVM) that provided continuous, real-time measurements of minute ventilation (MV), tidal volume (TV) and respiratory rate (RR) was used to monitor respiratory performance before, during, and after endoscopic procedures, quantify MV changes before and after airway maneuvers, and to quantify propofol-induced respiratory depression. Methods: RVM traces were obtained from 25 patients undergoing sedation for endoscopic procedures. Airway maneuvers were performed in 19/25 patients. All 25 patients received propofol as the primary sedative. Results: Forty-five airway maneuvers were performed. During these maneuvers, all respiratory parameters increased relative to pre-maneuver levels. On average, MV increased by 24% ± 5% (mean ± SEM), TV 14% ± 5% and RR: 17% ± 6%. The cohort average MVBASELINE was 9.5 ± 0.7 L/min (TV = 670 ± 60 ml, RR = 15 ± 0.7). Following propofol MV decreased transiently, reaching nadir five minutes after the last dose of propofol at 82% ± 10% of baseline (MV = 7.5 ± 1.0 L/min). The reduction in MV was driven by reduction in TV, not RR. Conclusions: Data demonstrated that RVM was able to track changes in ventilation and was able to quantify respiratory changes following airway maneuvers. All patients had a significant reduction in ventilatory volumes after propofol. Five minutes after the last dose of propofol, MV and TV were significantly reduced while RR was not, suggesting that monitoring respiratory rate alone was not a sufficient indicator of respiratory status. 展开更多
关键词 Non-Invasive RESPIRATORY volume MONITORING Minute ventilation Airway MANEUVERS PROCEDURAL SEDATION Endoscopy
下载PDF
Effect of glucocorticoid on MIP-1α and NF-кb expressing in the lung of rats undergoing mechanical ventilation with a high tidal volume 被引量:4
15
作者 Zhi-hong Liu Xin-ri Zhang +3 位作者 Xiao-yun Hu Meng-yu Cheng Jian-ying Xu Yong-cheng Du 《World Journal of Emergency Medicine》 CAS 2011年第1期66-69,共4页
BACKGROUND: Ventilator induced lung injury (VILI) is a serious complication in the treatment of mechanical ventilating patients, and it is also the main cause that results in exacerbation or death of patients. In t... BACKGROUND: Ventilator induced lung injury (VILI) is a serious complication in the treatment of mechanical ventilating patients, and it is also the main cause that results in exacerbation or death of patients. In this study, we produced VILI models by using glucocorticoid in rats with high tidal volume mechanical ventilation, and observed the content of macrophage inflammatory protein-1α (MIP-1α) in plasma and bronchoalveolar lavage fluid (BALF) and the expression of MIP-1α mRNA and nuclear factor-kappa B (NF-кB) p65 mRNA in the lung so as to explore the role of glucocorticoid in mechanical ventilation.METHODS: Thirty-two healthy Wistar rats were randomly divided into a control group, a ventilator induced lung injury (VILI) group, a dexamethasone (DEX) group and a budesonide (BUD) group. The content of MIP-1a in plasma and BALF was measured with ELISA and the level of MIP-1α mRNA and NF-кBp65 mRNA expressing in the lung of rats were detected by RT-PCR. The data were expressed as mean±SD and were compared between the groups.RESULTS: The content of MIP-1α in plasma and BALF and the level of MIP-1α mRNA and NF-кBp65 mRNA in the lung in the DEX and BUD groups were signifi cantly lower than those in the VILI group (P〈0.001). Although the content of MIP-1α in plasma and BALF and the level of MIP-1α mRNA and NF-кBp65 mRNA in the lung in the BUD group were higher than those in the DEX group, there were no signifi cant differences between them (P〉0.05).CONCLUSIONS: Glucocorticoid could down-regulate the expression of MIP-1α by inhibiting the activity of NF-кB in the lung and may exert preventive and therapeutic effects on VILI to some extent. The effect of local use of glucocorticoid against VILI is similar to that of systemic use, but there is lesser adverse reaction. 展开更多
关键词 Mechanical ventilation Lung injury Macrophage inflammatory protein-1α Nuclear factor-kappa B GLUCOCORTICOID Infiammation
下载PDF
Theoretical analysis and applications of Y-Inversion Ventilation System in a mine fire zone 被引量:1
16
作者 YANG Shengqlang PANG Weidong +3 位作者 WEN Hu YU Baohua MA Zhihe HUANG Ruiling 《Mining Science and Technology》 EI CAS 2010年第5期672-676,共5页
Based on mine fire fighting practices at the 1110 working face of the Brapukuria Coal Mine,Bangladesh,we introduce and discuss the Y-Inversion Ventilation System,the latest technology used both in mine fire zone manag... Based on mine fire fighting practices at the 1110 working face of the Brapukuria Coal Mine,Bangladesh,we introduce and discuss the Y-Inversion Ventilation System,the latest technology used both in mine fire zone management and the unsealing process.This ventilation system can ensure that all miners breathed fresh air,providing protection for them during fire fighting and unsealing the fire zone.On the other hand,adjusting the amount of air at the working face and forming a CO leakage path controlled the state of the fire and as well ensured that the different fire extinguishing measures could be applied successfully.These are all fundamental techniques which ensured successful fire extinguishing and unsealing of the fire zone.We also analyzed the main reasons for the spontaneous coal combustion that occurred at the 1110 working face.Successful application of advanced composite polymer colloidal perfusion techniques,polymer foam MEA perfusion and fire-prevention technology by infusing nitrogen,used in mine fire zone management and unsealing,are presented.We value the experience with these techniques very highly and are of the opinion that these techniques could be widely used in mine fire fighting practices under similar spontaneous coal combustion conditions elsewhere. 展开更多
关键词 Brapukuria Coal Mine coal mine fire zone management Y-Inversion ventilation System
下载PDF
Simulation on spread of fire smoke in the elevator shaft for a high-rise building
17
作者 Yunchun Xia 《Theoretical & Applied Mechanics Letters》 CAS 2014年第3期80-85,共6页
Spread of fire smoke in the elevator shaft of a high-rise building is influ- enced by many driving facts. We simulate smoke spreading in the elevator shaft, stair room, and pre-chamber with and without different suppl... Spread of fire smoke in the elevator shaft of a high-rise building is influ- enced by many driving facts. We simulate smoke spreading in the elevator shaft, stair room, and pre-chamber with and without different supplied pressurized air. The simulation shows that smoke moves very fast in the elevator shaft. When a 12 floor high-rise building is in fire, smoke can fill up the elevator shaft in less than 1.5 min after a fire started, temperature in the elevator shaft can be higher than 187℃ in 5 rain, and the concentration of CO can also reach a high level. The elevator shaft has a very low visibility in less than about 100 s. 展开更多
关键词 high-rise building elevator shaft stair room smoke spread
下载PDF
Analysis of Smoke Distribution in the Subway Station with Various Main Tunnel Ventilations 被引量:2
18
作者 Yong-Jun Jang Ji-Min Ryu Sung-Huk Park Dong-Hoe Koo 《Journal of Energy and Power Engineering》 2015年第4期405-410,共6页
Fire-driven flow analysis in the underground subway station has been performed with various main tunnel ventilations. Shin-gum-ho station (depth: 46 m) in Seoul is selected as a simulation model. The ventilation mo... Fire-driven flow analysis in the underground subway station has been performed with various main tunnel ventilations. Shin-gum-ho station (depth: 46 m) in Seoul is selected as a simulation model. The ventilation mode is assumed to be emergency state. Various main tunnel ventilations are applied to operate in a proper way for helping of smoke exhaustion in platform. The entire station is covered for simulation. Ventilation diffusers are modeled as 95 square shapes of 0.6 m × 0.6 m in the lobby and as 222 square shapes of 0.6 m × 0.6 m and four rectangular shapes of 1.2 m × 0.8 m in the platform. The total of 7.5 million grids is generated and whole domain is divided to 22 blocks for MPI (massage passing interface) efficiency of calculation. LES (large eddy simulation) is applied to solve the momentum equation. Smagorinsky model (Cs = 0.2) is used as SGS (subgrid scale) model. The distribution of CO (carbon monoxide) is calculated for various capacity of main tunnel ventilation and compared with each other. 展开更多
关键词 Subway station main tunnel ventilation fire-driven flow LES.
下载PDF
The effect of different inflation volumes of laryngeal mask airway on efficacy of closed circuit controlled ventilation in pediatric cancer patients
19
作者 Magda S.Azer Ayman A.Ghoneim Hossam Z.Ghobrial 《The Chinese-German Journal of Clinical Oncology》 CAS 2013年第12期596-601,共6页
Objective: The laryngeal mask airway (LMA) is an established way for airway control during spontaneous ventila- tion. Its ability to deliver positive pressure ventilation without leakage especially in low flow stat... Objective: The laryngeal mask airway (LMA) is an established way for airway control during spontaneous ventila- tion. Its ability to deliver positive pressure ventilation without leakage especially in low flow states is still controversy. The aim of this study is to test the possibility of using LMA in pediatric closed circuit controlled ventilation, and to find out the optimum cuff volume to perform closed system ventilation. Methods: Twenty children scheduled for elective surgeries were enrolled in a crossover study. Laryngeal mask airway was used. In stage I, the cuff was inflated with the maximum volume of air as rec- ommended by the manufacturers. Adjustment of volume of air inflated into the LMA cuff to the minimum volume to obtain the effective seal was done at stage II. The leak pressure, intracuff pressure and the leak volume were measured in both stages. Results: The cuff filling volume was significantly lower compared to the maximum cuff inflation volume in stage I. Leakage values showed significantly less values in stage II of the study with smaller cuff inflation volumes. The airway leakage pressure was significantly lower in stage fl in comparison to stage I. Cuff inflation pressure in stage I showed marked elevation which dropped significantly after adjustment of cuff volume in stage I1. Conclusion: Laryngeal mask airway is an effective tool to provide closed circuit controlled ventilation in pediatrics. Inflation of the cuff by the minimum volume of air needed to reach the just sealing pressure is suggested to minimize the leakage volume. 展开更多
关键词 laryngeal mask airway (LMA) PEDIATRIC controlled ventilation closed circuit intracuff volume leak pressure
下载PDF
A study on the characterization of smoke movement in shafts with different fire source positions
20
作者 Zhu Jie Yang Tianyou +1 位作者 Wu Jianbo Du Lulu 《Engineering Sciences》 EI 2013年第6期72-79,共8页
In this study,experimental and numerical simulation methods were combined to simulate the changing course of the temperature and velocity fields in nine different fire scenes. The characteristics of smoke movement in ... In this study,experimental and numerical simulation methods were combined to simulate the changing course of the temperature and velocity fields in nine different fire scenes. The characteristics of smoke movement in shafts with different fire source position factors(h/H) were quantitatively investigated,and the non-dimensional fitting function between the fire source position factors and the maximum temperature was deduced. The results showed that the location of the neutral plane moved upward as the fire source rose,and all the generated smoke spread to the upper areas;however,there was barely any smoke in the lower areas. The maximum temperature was inversely proportional to the fire source position factor;the higher the source position is,i.e. the higher the ratio factor is,the lower the maximum temperature is in the shaft. The experimental verification of the fire dynamics simulator(FDS) showed good results. 展开更多
关键词 different fire source position shaft structure smoke movement FDS field simulation TEMPERATURE fitting function
下载PDF
上一页 1 2 250 下一页 到第
使用帮助 返回顶部