As high-rise cooling towers are constantly emerging,wind effects on this kind of wind-sensitive structures have attracted more and more attention,especially in typhoon prone areas.Terrain Type B turbulent flow fields ...As high-rise cooling towers are constantly emerging,wind effects on this kind of wind-sensitive structures have attracted more and more attention,especially in typhoon prone areas.Terrain Type B turbulent flow fields under the normal wind and typhoon are simulated by active wind tunnel technology,and rigid-pressure-measurement model and aero-elastic-vibration-measurement model of a large cooling tower are built.The stagnation point,peak suction point,separation point and leeward point of the throat position shell are selected to analyze pressure coefficient,probability distribution,peak factor,power spectral density and dynamic amplification factor under normal wind and typhoon.It is clarified that there exists a significant non-Gaussian characteristic under typhoon condition,which also exists in structural response level.Resonance response ratio of the total response is higher during typhoon condition.The maximum value of dynamic amplification coefficient under typhoon field is up to 1.18 times over that under normal wind.The findings of this study are expected to be of interest and practical use to professional and researchers involved in the wind-resistant designs of super-large cooling towers in typhoon prone regions.展开更多
Traditional gust load factor(GLF)method,inertial wind load(IWL)method and tri-component method(LRC+IWL)cannot accurately analyze the wind-induced responses of super-large cooling towers,so the real combination formula...Traditional gust load factor(GLF)method,inertial wind load(IWL)method and tri-component method(LRC+IWL)cannot accurately analyze the wind-induced responses of super-large cooling towers,so the real combination formulas of fluctuating wind-induced responses and equivalent static wind loads(ESWLSs)were derived based on structural dynamics and random vibration theory.The consistent coupled method(CCM)was presented to compensate the coupled term between background and resonant response.Taking the super-large cooling tower(H=215 m)of nuclear power plant in Jiangxi Province,China,which is the highest and largest in China,as the example,based on modified equivalent beam-net design method,the aero-elastic model for simultaneous pressure and vibration measurement of super-large cooling tower is firstly carried out.Then,combining wind tunnel test and CCM,the effects of self-excited force on the surface pressures and wind-induced responses are discussed,and the wind-induced response characteristics of background component,resonant component,coupled term between background and resonant response,fluctuating responses,and wind vibration coefficients are discussed.It can be concluded that wind-induced response mechanism must be understood to direct the wind resistant design for super-large cooling towers.展开更多
双烟囱结构在自然风作用下存在气动干扰效应,从而诱发较大风致振动,威胁结构安全.合理计算和预测风振响应是双烟囱抗风设计的关键.以某中心距为8倍平均直径的双烟囱结构为研究对象,开展刚性模型测力和气弹模型测振风洞试验,将试验结果...双烟囱结构在自然风作用下存在气动干扰效应,从而诱发较大风致振动,威胁结构安全.合理计算和预测风振响应是双烟囱抗风设计的关键.以某中心距为8倍平均直径的双烟囱结构为研究对象,开展刚性模型测力和气弹模型测振风洞试验,将试验结果与中国规范、欧洲规范和CICIND(International Committee on Industrial Construction)规范计算值进行比较,详细研究双烟囱在不同风向角下的风致响应特性.研究结果表明:在烟囱串列布置下,迎风侧烟囱具有遮挡和干扰效应,一方面使得背风侧烟囱底部弯矩减小,另一方面使其横风向位移大于在其他风向角下的值;由于厂房的干扰效应,风振系数中国规范计算值与试验值接近;当烟囱高度超过厂房高度后,计算值较试验值偏大;对于横向响应,中国规范计算值较试验值大37.1%,欧洲规范计算值与试验值接近,仅偏小6.9%,CICIND规范计算值比试验值小17.1%.展开更多
基金supported by the National Key Research and Development Program of China (Nos. 2018YFC0809600,2018YFC0809604)the National Natural Science Foundation of China(No.51678451).
文摘As high-rise cooling towers are constantly emerging,wind effects on this kind of wind-sensitive structures have attracted more and more attention,especially in typhoon prone areas.Terrain Type B turbulent flow fields under the normal wind and typhoon are simulated by active wind tunnel technology,and rigid-pressure-measurement model and aero-elastic-vibration-measurement model of a large cooling tower are built.The stagnation point,peak suction point,separation point and leeward point of the throat position shell are selected to analyze pressure coefficient,probability distribution,peak factor,power spectral density and dynamic amplification factor under normal wind and typhoon.It is clarified that there exists a significant non-Gaussian characteristic under typhoon condition,which also exists in structural response level.Resonance response ratio of the total response is higher during typhoon condition.The maximum value of dynamic amplification coefficient under typhoon field is up to 1.18 times over that under normal wind.The findings of this study are expected to be of interest and practical use to professional and researchers involved in the wind-resistant designs of super-large cooling towers in typhoon prone regions.
基金Projects(50978203,51208254)supported by the National Natural Science Foundation of ChinaProject(BK2012390)supported by Natural Science Foundation of Jiangsu Province,ChinaProject supported by the Priority Academic Program Development of Jiangsu Higher Education Institutions,China
文摘Traditional gust load factor(GLF)method,inertial wind load(IWL)method and tri-component method(LRC+IWL)cannot accurately analyze the wind-induced responses of super-large cooling towers,so the real combination formulas of fluctuating wind-induced responses and equivalent static wind loads(ESWLSs)were derived based on structural dynamics and random vibration theory.The consistent coupled method(CCM)was presented to compensate the coupled term between background and resonant response.Taking the super-large cooling tower(H=215 m)of nuclear power plant in Jiangxi Province,China,which is the highest and largest in China,as the example,based on modified equivalent beam-net design method,the aero-elastic model for simultaneous pressure and vibration measurement of super-large cooling tower is firstly carried out.Then,combining wind tunnel test and CCM,the effects of self-excited force on the surface pressures and wind-induced responses are discussed,and the wind-induced response characteristics of background component,resonant component,coupled term between background and resonant response,fluctuating responses,and wind vibration coefficients are discussed.It can be concluded that wind-induced response mechanism must be understood to direct the wind resistant design for super-large cooling towers.
文摘双烟囱结构在自然风作用下存在气动干扰效应,从而诱发较大风致振动,威胁结构安全.合理计算和预测风振响应是双烟囱抗风设计的关键.以某中心距为8倍平均直径的双烟囱结构为研究对象,开展刚性模型测力和气弹模型测振风洞试验,将试验结果与中国规范、欧洲规范和CICIND(International Committee on Industrial Construction)规范计算值进行比较,详细研究双烟囱在不同风向角下的风致响应特性.研究结果表明:在烟囱串列布置下,迎风侧烟囱具有遮挡和干扰效应,一方面使得背风侧烟囱底部弯矩减小,另一方面使其横风向位移大于在其他风向角下的值;由于厂房的干扰效应,风振系数中国规范计算值与试验值接近;当烟囱高度超过厂房高度后,计算值较试验值偏大;对于横向响应,中国规范计算值较试验值大37.1%,欧洲规范计算值与试验值接近,仅偏小6.9%,CICIND规范计算值比试验值小17.1%.