Electrochemical impedance spectroscopy(EIS)flow cytometry offers the advantages of speed,affordability,and portability in cell analysis and cytometry applications.However,the integration challenges of microfluidic and...Electrochemical impedance spectroscopy(EIS)flow cytometry offers the advantages of speed,affordability,and portability in cell analysis and cytometry applications.However,the integration challenges of microfluidic and EIS read-out circuits hinder the downsizing of cytometry devices.To address this,we developed a thermal-bubble-driven impedance flow cytometric application-specific integrated circuit(ASIC).The thermal-bubble micropump avoids external piping and equipment,enabling high-throughput designs.With a total of 36 cell counting channels,each measuring 884×220μm^(2),the chip significantly enhances the throughput of flow cytometers.Each cell counting channel incorporates a differential trans-impedance amplifier(TIA)to amplify weak biosensing signals.By eliminating the parasitic parameters created at the complementary metal-oxidesemiconductor transistor(CMOS)-micro-electromechanical systems(MEMS)interface,the counting accuracy can be increased.The on-chip TIA can adjust feedback resistance from 5 to 60 kΩto accommodate solutions with different impedances.The chip effectively classifies particles of varying sizes,demonstrated by the average peak voltages of 0.0529 and 0.4510 mV for 7 and 14μm polystyrene beads,respectively.Moreover,the counting accuracies of the chip for polystyrene beads and MSTO-211H cells are both greater than 97.6%.The chip exhibits potential for impedance flow cytometer at low cost,high-throughput,and miniaturization for the application of point-of-care diagnostics.展开更多
基金supported by the Key Project of the National Natural Science Foundation of China(Grant No.82130069).
文摘Electrochemical impedance spectroscopy(EIS)flow cytometry offers the advantages of speed,affordability,and portability in cell analysis and cytometry applications.However,the integration challenges of microfluidic and EIS read-out circuits hinder the downsizing of cytometry devices.To address this,we developed a thermal-bubble-driven impedance flow cytometric application-specific integrated circuit(ASIC).The thermal-bubble micropump avoids external piping and equipment,enabling high-throughput designs.With a total of 36 cell counting channels,each measuring 884×220μm^(2),the chip significantly enhances the throughput of flow cytometers.Each cell counting channel incorporates a differential trans-impedance amplifier(TIA)to amplify weak biosensing signals.By eliminating the parasitic parameters created at the complementary metal-oxidesemiconductor transistor(CMOS)-micro-electromechanical systems(MEMS)interface,the counting accuracy can be increased.The on-chip TIA can adjust feedback resistance from 5 to 60 kΩto accommodate solutions with different impedances.The chip effectively classifies particles of varying sizes,demonstrated by the average peak voltages of 0.0529 and 0.4510 mV for 7 and 14μm polystyrene beads,respectively.Moreover,the counting accuracies of the chip for polystyrene beads and MSTO-211H cells are both greater than 97.6%.The chip exhibits potential for impedance flow cytometer at low cost,high-throughput,and miniaturization for the application of point-of-care diagnostics.