The so-called indirect evaporative cooling technology is widely used in air conditioning applications.The thermal characterization of tube-type indirect evaporative coolers,however,still presents challenges which need...The so-called indirect evaporative cooling technology is widely used in air conditioning applications.The thermal characterization of tube-type indirect evaporative coolers,however,still presents challenges which need to be addressed to make this technology more reliable and easy to implement.This experimental study deals with the performances of a tube-type indirect evaporative cooler based on an aluminum tube with a 10 mm diameter.In particular,the required tests were carried out considering a range of dry-bulb temperatures between 16℃ and 18℃ and a temperature difference between the wet-bulb and dry-bulb temperature of 2℃∼4℃.The integrated convective heat transfer coefficient inside the tube in the drenching condition has been found to lie in the range between 36.10 and 437.4(W/(m^(2)⋅K)).展开更多
The material design is used to direct the magnetron cosputtering process. At first, according to the particularity of functionally gradient coat (FGC) the thermal elastic stress analysis for FGC was carried out based ...The material design is used to direct the magnetron cosputtering process. At first, according to the particularity of functionally gradient coat (FGC) the thermal elastic stress analysis for FGC was carried out based on the plane stress hypothesis. It is obtained that the peak value of plane thermal stress within FGC is only determined by the physical properties of materials of FGC and substrate, the composition distribution coefficient only influences the distribution and trend of plane thermal stress. And the plane thermal stress criterion for design of FGC was presented. Then the plane thermal stress of diamond like carbon/titanium alloy FGC was calculated.展开更多
The Low Energy X-ray Instrument (LE) of the Hard X-ray Modulation Telescope (HXMT) uses the Swept Charge Device (SCD) to detect the X-rays in 1-15 keV. The performance of SCD is vulnerable to temperature. We ana...The Low Energy X-ray Instrument (LE) of the Hard X-ray Modulation Telescope (HXMT) uses the Swept Charge Device (SCD) to detect the X-rays in 1-15 keV. The performance of SCD is vulnerable to temperature. We analyzed the thermal condition of LE at different satellite working attitudes with the Finite Element Method (FEM). It is shown that the angle between the sunlight and the normal line of the barrier should be less them 26°, to keep the SCD detectors working in the required temperature range, i.e. -40 ℃ to -80 ℃. We find that the performance of LE is very stable in this temperature range, with a typical energy resolution of 160 eV at 5.9 keV.展开更多
基金This work was supported by Natural Science Basic Research Program of Shaanxi(2021JQ-689).
文摘The so-called indirect evaporative cooling technology is widely used in air conditioning applications.The thermal characterization of tube-type indirect evaporative coolers,however,still presents challenges which need to be addressed to make this technology more reliable and easy to implement.This experimental study deals with the performances of a tube-type indirect evaporative cooler based on an aluminum tube with a 10 mm diameter.In particular,the required tests were carried out considering a range of dry-bulb temperatures between 16℃ and 18℃ and a temperature difference between the wet-bulb and dry-bulb temperature of 2℃∼4℃.The integrated convective heat transfer coefficient inside the tube in the drenching condition has been found to lie in the range between 36.10 and 437.4(W/(m^(2)⋅K)).
文摘The material design is used to direct the magnetron cosputtering process. At first, according to the particularity of functionally gradient coat (FGC) the thermal elastic stress analysis for FGC was carried out based on the plane stress hypothesis. It is obtained that the peak value of plane thermal stress within FGC is only determined by the physical properties of materials of FGC and substrate, the composition distribution coefficient only influences the distribution and trend of plane thermal stress. And the plane thermal stress criterion for design of FGC was presented. Then the plane thermal stress of diamond like carbon/titanium alloy FGC was calculated.
文摘The Low Energy X-ray Instrument (LE) of the Hard X-ray Modulation Telescope (HXMT) uses the Swept Charge Device (SCD) to detect the X-rays in 1-15 keV. The performance of SCD is vulnerable to temperature. We analyzed the thermal condition of LE at different satellite working attitudes with the Finite Element Method (FEM). It is shown that the angle between the sunlight and the normal line of the barrier should be less them 26°, to keep the SCD detectors working in the required temperature range, i.e. -40 ℃ to -80 ℃. We find that the performance of LE is very stable in this temperature range, with a typical energy resolution of 160 eV at 5.9 keV.