Maintaining thermal comfort within the human body is crucial for optimal health and overall well-being.By merely broadening the setpoint of indoor temperatures,we could significantly slash energy usage in building hea...Maintaining thermal comfort within the human body is crucial for optimal health and overall well-being.By merely broadening the setpoint of indoor temperatures,we could significantly slash energy usage in building heating,ventilation,and air-conditioning systems.In recent years,there has been a surge in advancements in personal thermal management(PTM),aiming to regulate heat and moisture transfer within our immediate surroundings,clothing,and skin.The advent of PTM is driven by the rapid development in nano/micro-materials and energy science and engineering.An emerging research area in PTM is personal radiative thermal management(PRTM),which demonstrates immense potential with its high radiative heat transfer efficiency and ease of regulation.However,it is less taken into account in traditional textiles,and there currently lies a gap in our knowledge and understanding of PRTM.In this review,we aim to present a thorough analysis of advanced textile materials and technologies for PRTM.Specifically,we will introduce and discuss the underlying radiation heat transfer mechanisms,fabrication methods of textiles,and various indoor/outdoor applications in light of their different regulation functionalities,including radiative cooling,radiative heating,and dual-mode thermoregulation.Furthermore,we will shine a light on the current hurdles,propose potential strategies,and delve into future technology trends for PRTM with an emphasis on functionalities and applications.展开更多
At present,air handling units are usually used indoors to improve the indoor environment quality.However,while introducing fresh air to improve air quality,air velocity has a certain impact on the occupants’thermal c...At present,air handling units are usually used indoors to improve the indoor environment quality.However,while introducing fresh air to improve air quality,air velocity has a certain impact on the occupants’thermal comfort.Therefore,it is necessary to explore the optimization of air-fluid-body interaction dynamics.In this study,the indoor air flow was changed by changing the opening and closing degree of the blower,and the thermal manikin is introduced to objectively evaluate the human thermal comfort under different air velocities.The main experimental results show that the air change rate increases with the increase of the opening and closing degree of the blower considering an ACH(air changes per hour)range between 3.8 and 10.For a better prediction,a linear correlation with a coefficient of 0.995 is proposed.As the blower’s opening is adjusted to 20%,25%,30%,35%,and 40%,the air velocity sensor positioned directly beneath the air inlet records average velocities of 0.19,0.20,0.21,0.28,and 0.34 m/s over four hours,respectively.Observations on thermal comfort and the average sensation experienced by individuals indicate an initial increase followed by a decline when the blower’s operation begins,with optimal conditions achieved at a 35%opening.These findings offer valuable insights for future indoor air ventilation and heat transfer design strategies.展开更多
Nowadays, the global climate is constantly being destroyed and the fluctuations in ambient temperature are becoming more frequent. However, conventional single-mode thermal management strategies(heating or cooling) fa...Nowadays, the global climate is constantly being destroyed and the fluctuations in ambient temperature are becoming more frequent. However, conventional single-mode thermal management strategies(heating or cooling) failed to resolve such dynamic temperature changes. Moreover, developing thermal management devices capable of accommodating these temperature variations while remaining simple to fabricate and durable has remained a formidable obstacle. To address these bottlenecks, we design and successfully fabricate a novel dual-mode hierarchical(DMH) composite film featuring a micronanofiber network structure, achieved through a straightforward two-step continuous electrospinning process. In cooling mode, it presents a high solar reflectivity of up to 97.7% and an excellent atmospheric transparent window(ATW) infrared emissivity of up to 98.9%. Noted that this DMH film could realize a cooling of 8.1 ℃ compared to the ambient temperature outdoors. In heating mode, it also exhibits a high solar absorptivity of 94.7% and heats up to 11.9 ℃ higher than black cotton fabric when utilized by individuals. In practical application scenarios, a seamless transition between efficient cooling and heating is achieved by simply flipping the film. More importantly, the DMH film combining the benefits of composites demonstrates portability, durability, and easy-cleaning, promising to achieve large-scale production and use of thermally managed textiles in the future. The energy savings offered by film applications provide a viable solution for the early realization of carbon neutrality.展开更多
The landscape environment of urban blocks plays a significant role in improving the comfort of urban thermal environment and promoting green and high-quality development.The 342 papers related to the research on the i...The landscape environment of urban blocks plays a significant role in improving the comfort of urban thermal environment and promoting green and high-quality development.The 342 papers related to the research on the impact of urban block landscape environment on thermal comfort in China,collected by CNKI(China National Knowledge Infrastructure)from 2002 to 2022,are used as the research object.Through bibliometric statistical analysis,LLR algorithm,and cluster analysis,the current research status of the impact of urban block landscape environment on thermal comfort in China is analyzed and processed,and its external characteristics are identified.Using the information visualization software CiteSpace,the research topics in the field of the impact of urban block landscape environment on thermal comfort are presented in the form of knowledge graphs.Through co-occurrence analysis of keywords and trend of word frequency changes,the development trends of research hotspots and cutting-edge fields of the impact of urban block landscape environment on thermal comfort are determined,hoping to provide reference for future research in this field.展开更多
Thermal comfort evaluations for Yuexiu Park,Lushan Park,and Baiyun Lake Park in Guangzhou were conducted using field meteorological data collection,visitor questionnaires,and literature reviews.It analyzed the impact ...Thermal comfort evaluations for Yuexiu Park,Lushan Park,and Baiyun Lake Park in Guangzhou were conducted using field meteorological data collection,visitor questionnaires,and literature reviews.It analyzed the impact of green coverage,water body layout,and facility configuration on thermal comfort.The results showed that good green and water body design effectively lowered the temperature in the park and improved the thermal comfort of visitors,but the insufficient facility configuration in some open areas affected the experience.The visitor’s experience is closely related to the natural environment and facility layout of the park.Therefore,in the future,park design should pay more attention to the rational configuration of shading,ventilation,and cooling facilities to improve thermal comfort,and encourage citizens to participate in the construction and management of parks to improve ecological quality and user experience.This study provides a reference for the improvement of thermal comfort in urban parks in Guangzhou and aims to promote the sustainable and human-oriented development of urban park design.展开更多
This work falls within the context of reducing energy consumption in Côte d’Ivoire. As the building sector is one of the energy consumers worldwide, it could be a major source of energy savings. A major source o...This work falls within the context of reducing energy consumption in Côte d’Ivoire. As the building sector is one of the energy consumers worldwide, it could be a major source of energy savings. A major source of energy savings. With this in mind thermal comfort in buildings in Côte d’Ivoire (Abidjan) in order to determine (Abidjan) to determine thermal comfort conditions. To carry out study, measurement campaigns were carried out in various buildings. These measured parameters were used to calculate comfort indices such as PMV, PDD, SET and operating temperature. A correlation was then made between the PMV index and the operating temperature, then between the SET and the operating temperature to determine the thermoneutrality temperature and the different thermal comfort thermal comfort ranges. The PMV gave a thermoneutrality temperature of 24.87˚C in the rainy season and a thermoneutrality temperature of 25.15˚C during the dry season. In addition, the SET gave comfort ranges, with values ranging from 23.23˚C to 25.70˚C in the rainy season and 23.35˚C to 26.08˚C in the dry season. In addition, the acceptability predicted by the PDD showed that in the rainy season, the premises were more acceptable than in the dry season.展开更多
Buildings constructed with modern materials (cement blocks, sheet metal, reinforced concrete, etc.) in the Sahelian zone often generate excessive electricity consumption and consequently very high electricity bills. T...Buildings constructed with modern materials (cement blocks, sheet metal, reinforced concrete, etc.) in the Sahelian zone often generate excessive electricity consumption and consequently very high electricity bills. This study is a contribution to the development of new building types based on the principle of bioclimatic construction. The aim is to find materials suited to the Sahelian climate and improve thermal comfort. To this end, an experimental study of the hygrothermal behavior of a bioclimatic building prototype with a domed roof is being carried out. Site meteorological data, air temperature and relative humidity of the building’s internal environment were measured for three climatic seasons in Burkina Faso. The data acquisition system consists of thermocouples, solarimeters and humidity meters, and the data are processed using Excel and Origin Pro software. The results show that, despite the high temperature values (between 36˚C and 39˚C) of the internal environment measured in the hot season, good thermal performance is achieved, in particular an average phase shift of 7.17 h and an average damping of 10.81˚C. The dome-roofed building could therefore contribute to limiting heat transmission to the building interior, improving thermal comfort all year round. Analysis of humidity profiles shows that indoor humidity varies between 66% and 80% for the September period, and between 44% and 69% for the January period. The high values of internal ambient humidity could be reduced by very good ventilation of the building. This study shows that the proposed bioclimatic building prototype with domed roof could be integrated into the Sahelian habitat.展开更多
Compressed earth blocks (CEB) are an alternative to cement blocks in the construction of wall masonry. However, the optimal architectural construction methods for adequate thermal comfort for occupants in hot and arid...Compressed earth blocks (CEB) are an alternative to cement blocks in the construction of wall masonry. However, the optimal architectural construction methods for adequate thermal comfort for occupants in hot and arid environments are not mastered. This article evaluates the influence of architectural and constructive modes of buildings made of CEB walls and concrete block walls, to optimize and compare their thermal comfort in the hot and dry tropical climate of Ouagadougou, Burkina Faso. Two identical pilot buildings whose envelopes are made of CEB and concrete blocks were monitored for this study. The thermal models of the pilot buildings were implemented in the SketchUp software using an extension of EnergyPlus. The models were empirically validated after calibration against measured thermal data from the buildings. The models were used to do a parametric analysis for optimization of the thermal performances by simulating plaster coatings on the exterior of walls, airtight openings and natural ventilation depending on external weather conditions. The results show that the CEB building displays 7016 hours of discomfort, equivalent to 80.1% of the time, and the concrete building displays 6948 hours of discomfort, equivalent to 79.3% of the time. The optimization by modifications reduced the discomfort to 2918 and 3125 hours respectively;i.e. equivalent to only 33.3% for the CEB building and 35.7% for the concrete building. More study should evaluate thermal optimizations in buildings in real time of usage such as residential buildings commonly used by the local middle class. The use of CEB as a construction material and passive means of improving thermal comfort is a suitable ecological and economical option to replace cementitious material.展开更多
With the continuous intensification of the global greenhouse effect,thermal comfort has become a highly concerned issue in the living environment.The study explores the influencing factors and improvement strategies o...With the continuous intensification of the global greenhouse effect,thermal comfort has become a highly concerned issue in the living environment.The study explores the influencing factors and improvement strategies of urban street thermal comfort.The urban heat island effect,environmental parameters,building layout,and green planting all have a significant impact on the thermal comfort of streets.Improvement strategies include optimizing cultivating pattern of plants,adjusting street layout,and improving paving materials of road.The multi-layer vegetation structure provides green shade,reduces local temperature,and humidifies the surrounding environment.It should adjust the street orientation and aspect ratio to provide sunlight and ventilation,and reduce ambient temperature.Paving materials with low reflectivity and light color and permeable underlying surface should be chosen to reduce heat absorption,increase shading and greenery,and improve thermal comfort.展开更多
The purpose of this study is to experimentally analyze the thermal behavior of the walls of a prototype experimental house. A Datalogger and thermocouples were used on the experimental house to determine the temperatu...The purpose of this study is to experimentally analyze the thermal behavior of the walls of a prototype experimental house. A Datalogger and thermocouples were used on the experimental house to determine the temperatures of the exterior and interior walls. Also, “MSR” type HygroPuce was used to determine the exterior and interior temperatures and relative humidity of the habitat. The results show that a wall made of bio-based materials with a mixture of “earth + Hibiscus cannabinus L. fibers” allows reducing the fluctuations of the interior temperatures. We observe the peaks of temperatures on the external walls at 11:00 am and for the interior walls, the peaks are observed at 5:00 pm. The maximum thermal phase shift between the peaks of the external and internal temperatures is about 7.5 hours, and the maximum damping factor is 0.9. Also, we note that the thermal performance of the material used in the design of the envelope of the house is determined by the improvement of the response of the envelope in front of the external thermal solicitations.展开更多
The local skin temperatures of 22 subjects at air temperatures of 21,24,26,29 ℃ are measured,and the mean skin temperatures are calculated by ten skin temperature measuring points.The thermal comfort levels and the t...The local skin temperatures of 22 subjects at air temperatures of 21,24,26,29 ℃ are measured,and the mean skin temperatures are calculated by ten skin temperature measuring points.The thermal comfort levels and the thermal sensations of these subjects are also investigated by a questionnaire.The Mahalanobis distance discrimination method is applied to establish the evaluation model for the thermal comfort based on the mean skin temperature.The experimental results indicate that the difference of the mean skin temperatures between the comfort level and the discomfort level is significant.Using the evaluation model,the mean skin temperature at the thermal comfort level is 32.6 to 33.7 ℃,and the thermal comfort levels of 72% of the subjects are correctly evaluated.The accuracy of the evaluation model can be improved when the effects of sex of the subject on the mean skin temperature and the thermal comfort are considered.It can be concluded that the mean skin temperature can be used as an effective physiological indicator to evaluate human thermal comfort in a steady thermal environment.展开更多
This paper introduces a field measurement of an indoor thermal environment in rural housing in suburban Beijing from December 2008 to March 2009.The indoor environment parameters such as air temperature,mean radiant t...This paper introduces a field measurement of an indoor thermal environment in rural housing in suburban Beijing from December 2008 to March 2009.The indoor environment parameters such as air temperature,mean radiant temperature(MRT),airflow velocity and relative humidity are measured.A questionnaire survey of the occupants' thermal sensations in these surveyed houses is conducted and their daily activities and clothing conditions are recorded.The results show that the thermal neutral temperature of rural housing is 18.4 ℃,and the lower limit of acceptable temperature range can be extended to 10.9 ℃.The comfortable indoor temperature is affected by the occupants' clothing and lifestyle.Therefore,the indoor temperature standards of space heating for suburban housing cannot be simply duplicated from that for urban housing.Compared with occupants in suburban Beijing,it is found that the occupants in rural Hunan province feel colder at the same operative temperature due to the high relative humidity in Hunan province.展开更多
Field measurements on thermal comfort were carried out in a building with double-skin faade from January 14th to 16th,2009.Data are obtained by measurements of physical parameters and a questionnaire survey is conduct...Field measurements on thermal comfort were carried out in a building with double-skin faade from January 14th to 16th,2009.Data are obtained by measurements of physical parameters and a questionnaire survey is conducted at the same time in 27 offices of the building.The subjective survey involves questions on demographic information of the occupants,health status,environmental comfort conditions and acceptance.A total of 150 occupants are investigated and 131 questionnaires are completed.The statistical data presents the distributions of predicted mean vote,mean thermal sensation vote,mean thermal comfort vote,thermal acceptability,etc.The results show that low relative humidity is the main reason causing thermal discomfort.The greatest discomfort is dry mouth and eye dryness which are caused by low relative humidity.The females are verified to be more sensitive than the males.Meanwhile,a double-skin faade represents a good noise insulation effect while the glare problem is still unresolved.展开更多
A new ground source heat pump system combined with radiant heating/cooling is proposed, and the principles and the advantages of the system are analyzed. A demonstration of the system is applied to a rebuilt building...A new ground source heat pump system combined with radiant heating/cooling is proposed, and the principles and the advantages of the system are analyzed. A demonstration of the system is applied to a rebuilt building: Xijindu exhibition hall, which is located in Zhenjiang city in China. Numerical studies on the thermal comfort and energy consumption of the system are carded out by using TRNSYS software. The results indicate that the system with the radiant floor method or the radiant ceiling method shows good thermal comfort without mechanical ventilation in winter. However, the system with either of the methods should add mechanical ventilation to ensure good comfort in summer. At the same level of thermal comfort, it can also be found that the annual energy consumption of the radiant ceiling system is less than that of the radiant floor system.展开更多
In this paper,experimental and numerical studies of heat transfer in a test local of side H=0.8 m heated from below are presented and compared.All the walls,the rest of the floor and the ceiling are made from plywood ...In this paper,experimental and numerical studies of heat transfer in a test local of side H=0.8 m heated from below are presented and compared.All the walls,the rest of the floor and the ceiling are made from plywood and polystyrene in sandwich form(3 mmplywood-3 cm polystyrene-3 mmplywood)just on one of the vertical walls contained a glazed door(2 H/3×0.15 m).This local is heated during two heating cycles by a square plate of iron the width L=0.6 H,which represents the heat source,its temperature Th is controlled.The plate is heated for two cycles by an adjustable set-point heat source placed just down the center of it.For each cycle,the heat source is switched“on”for 6 h and switched“off”for 6 h.The outdoor air temperature is kept constant at a low temperature Tc<Th.All measurements are carried out with k-type thermocouples and with flux meters.Results will be qualitatively presented for two cycles of heating in terms of temperatures and heat flux densitiesϕfor various positions of the test local.The temperature evolution of the center and the profile of the temperature along the vertical centerline are compared by two dimensions simulation using the lattice Boltzmann method.The comparison shows a good agreement with a difference that does not exceed±1℃.展开更多
Buildings constructed using modern materials such as cement are energy-intensive, facilitate heat transfer and thus promote warming inside the building. However, the Sudano-Sahelian regions have a hot climate occupyin...Buildings constructed using modern materials such as cement are energy-intensive, facilitate heat transfer and thus promote warming inside the building. However, the Sudano-Sahelian regions have a hot climate occupying a large period of the year, thus requiring not only sustainable construction materials, but also which provide thermal comfort in the building by limiting the energy demand for air conditioning. These qualifications are important for sub-Saharan African countries in general and those of the Sudano-Sahelian zone in particular, which need ecological materials with good thermal performance to limit heating inside buildings. This study is an energy recovery of agricultural waste in buildings with a view to offering the populations of the northern regions of Cameroon suitable materials at lower cost for the construction of buildings. The soil used for this study was extracted from the locality of Yagoua where the populations make abundant use of mud bricks. Fonio waste was incorporated at low levels into the earth bricks, particularly at 0%, 1%, 2%, 3%, and 4%, with a view to strengthening their thermophysical and mechanical properties. The results obtained indicate that earth bricks reinforced with 4% waste showed better thermal and mechanical insulation properties compared to other formulations with an improvement of 16% and 78% respectively compared to the unreinforced samples. This research allows us to conclude that fonio waste can be used practically without expense in the building with a view to its energy recovery and will promote not only thermal comfort and the limitation of the energy supply for air conditioning, but the construction of more sustainable buildings with a cleaner environment.展开更多
There is a huge amount of energy savings potential in public building sector that has yet to be realized.By prioritizing energy efficiency in its own buildings and thus promoting the development of required knowledge ...There is a huge amount of energy savings potential in public building sector that has yet to be realized.By prioritizing energy efficiency in its own buildings and thus promoting the development of required knowledge in terms of new technology and construction methods,the public sector will lead the way in efforts to increase the rate of renovations.The low-cost insulation strategies and a comparison of cost with existing insulation materials has been described in this study.We have repeatedly faced energy crises and will continue to do so in the future if appropriate action is not taken in a timely manner.Properly implementing energy-saving initiatives in for achieving thermal comfort in buildings as well as reducing the energy costs would undoubtedly inspire the residential sector,resulting in significant reductions in energy usage.Simulations were carried out to study insulation layers on various building components like exterior walls,floor and roofs,generating different scenarios for a building as a base model,which were then compared and analysed to verify the literature used to develop the cases.The proposed recommendations,which have been validated,are certain to increase building energy efficiency,achieve thermal comfort in low cost than what is currently being used.展开更多
The existing investigations on thermal comfort mostly focus on the thermal environment conditions, especially of the air-flow field and the temperature distributions in vehicle cabin. Less attention appears to direct ...The existing investigations on thermal comfort mostly focus on the thermal environment conditions, especially of the air-flow field and the temperature distributions in vehicle cabin. Less attention appears to direct to the thermal comfort or thermal sensation of occupants, even to the relationship between thermal conditions and thermal sensation. In this paper, a series of experiments were designed and conducted for understanding the non-uniform conditions and the occupant's thermal responses in vehicle cabin during the heating period. To accurately assess the transient temperature distribution in cabin in common daily condition, the air temperature at a number of positions is measured in a full size vehicle cabin under natural winter environment in South China by using a discrete thermocouples network. The occupant body is divided into nine segments, the skin temperature at each segment and the occupant's local thermal sensation at the head, body, upper limb and lower limb are monitored continuously. The skin temperature is observed by using a discrete thermocouples network, and the local thermal sensation is evaluated by using a seven-point thermal comfort survey questionnaire proposed by American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc(ASHRAE) Standard. The relationship between the skin temperature and the thermal sensation is discussed and regressed by statistics method. The results show that the interior air temperature is highly non-uniform over the vehicle cabin. The locations where the occupants sit have a significant effect on the occupant's thermal responses, including the skin temperature and the thermal sensation. The skin temperaWa-e and thermal sensation are quite different between body segments due to the effect of non-uniform conditions, clothing resistance, and the human thermal regulating system. A quantitative relationship between the thermal sensation and the skin temperature at each body segment of occupant in real life traffic is presented. The investigation result indicates that the skin temperature is a robust index to evaluate the thermal sensation. Applying the skin temperature to designing and controlling parameters of the heating, ventilation and air conditioning(HVAC) system may benefit the thermal comfort and reducing energy consumption.展开更多
To explore the thermal responses under the non-thermal equilibrium cold environmental conditions,a laboratory study was conducted in climate chamber.The local skin temperatures and thermal sensation of 20 subjects wer...To explore the thermal responses under the non-thermal equilibrium cold environmental conditions,a laboratory study was conducted in climate chamber.The local skin temperatures and thermal sensation of 20 subjects were recorded at 10 min intervals for 90 min under air temperatures of 7.4,9.1,11 and 15 °C.The results show that both local skin temperatures and mean skin temperature decrease not only with the drop of ambient air temperature but also with the exposure time.Local thermal sensation and overall the thermal sensation have the similar temperature-varying and time-varying characteristics.Predicted mean vote(PMV) model cannot correctly predict the thermal sensation under non-thermal equilibrium cold environment.The correlation between local thermal sensation and local skin temperatures shows that thermal sensation is closely related to skin temperature.Skin temperature is an effective indicator of thermal sensation.A linear relationship model between overall thermal sensation and mean skin temperature,considering both ambient temperature and exposure time,was established in the non-thermal equilibrium cold environment,which makes the evaluation of thermal sensation more objective.展开更多
Planting trees along urban streets is one of the most important strategies to improve the urban thermal environment.However,the net impacts of urban street trees on human thermal comfort and physiological parameters a...Planting trees along urban streets is one of the most important strategies to improve the urban thermal environment.However,the net impacts of urban street trees on human thermal comfort and physiological parameters are still less clear.On three similar east-west orientated streets with different degrees of tree cover-low(13%),medium(35%),and high(75%),urban microclimatic parameters and human physiological indices for six male students were simultaneously measured on three cloudless days in summer 2018.The results show that the differences in tree cover were predominant in influencing urban thermal environment and comfort.The street with the highest tree cover had significantly lower physiological equivalent temperature(PET) and more comfortable than the other two streets.The frequency of strong heat stress(PET> 35℃) was 64%,11 %,and 0%,respectively,for streets with low,medium,and high tree cover.For the six male university students,human physiological indices varied greatly across the three streets with different tree cover.Systolic blood pressure,diastolic blood pressure,and pulse rate increased with decreasing tree cover.The results also suggest that urban thermal environment and comfort had considerable impact on human physiological parameters.Our study provides reasons for urban planners to plant trees along streets to improve the thermal environment and promote urban sustainability.展开更多
基金support from the Research Grants Council of the Hong Kong Special Administrative Region,China(PolyU152052/21E)Green Tech Fund of Hong Kong(Project No.:GTF202220106)+1 种基金Innovation and Technology Fund of the Hong Kong Special Administrative Region,China(ITP/018/21TP)PolyU Endowed Young Scholars Scheme(Project No.:84CC).
文摘Maintaining thermal comfort within the human body is crucial for optimal health and overall well-being.By merely broadening the setpoint of indoor temperatures,we could significantly slash energy usage in building heating,ventilation,and air-conditioning systems.In recent years,there has been a surge in advancements in personal thermal management(PTM),aiming to regulate heat and moisture transfer within our immediate surroundings,clothing,and skin.The advent of PTM is driven by the rapid development in nano/micro-materials and energy science and engineering.An emerging research area in PTM is personal radiative thermal management(PRTM),which demonstrates immense potential with its high radiative heat transfer efficiency and ease of regulation.However,it is less taken into account in traditional textiles,and there currently lies a gap in our knowledge and understanding of PRTM.In this review,we aim to present a thorough analysis of advanced textile materials and technologies for PRTM.Specifically,we will introduce and discuss the underlying radiation heat transfer mechanisms,fabrication methods of textiles,and various indoor/outdoor applications in light of their different regulation functionalities,including radiative cooling,radiative heating,and dual-mode thermoregulation.Furthermore,we will shine a light on the current hurdles,propose potential strategies,and delve into future technology trends for PRTM with an emphasis on functionalities and applications.
基金supported by the China Scholarship Council(Grant Number 202208120025).
文摘At present,air handling units are usually used indoors to improve the indoor environment quality.However,while introducing fresh air to improve air quality,air velocity has a certain impact on the occupants’thermal comfort.Therefore,it is necessary to explore the optimization of air-fluid-body interaction dynamics.In this study,the indoor air flow was changed by changing the opening and closing degree of the blower,and the thermal manikin is introduced to objectively evaluate the human thermal comfort under different air velocities.The main experimental results show that the air change rate increases with the increase of the opening and closing degree of the blower considering an ACH(air changes per hour)range between 3.8 and 10.For a better prediction,a linear correlation with a coefficient of 0.995 is proposed.As the blower’s opening is adjusted to 20%,25%,30%,35%,and 40%,the air velocity sensor positioned directly beneath the air inlet records average velocities of 0.19,0.20,0.21,0.28,and 0.34 m/s over four hours,respectively.Observations on thermal comfort and the average sensation experienced by individuals indicate an initial increase followed by a decline when the blower’s operation begins,with optimal conditions achieved at a 35%opening.These findings offer valuable insights for future indoor air ventilation and heat transfer design strategies.
基金financially Fundamental Research Funds for the Central Universities (2232021G-04 and 2232020D-20)Student Innovation Fund of Donghua University (GSIF-DH-M-2021003)。
文摘Nowadays, the global climate is constantly being destroyed and the fluctuations in ambient temperature are becoming more frequent. However, conventional single-mode thermal management strategies(heating or cooling) failed to resolve such dynamic temperature changes. Moreover, developing thermal management devices capable of accommodating these temperature variations while remaining simple to fabricate and durable has remained a formidable obstacle. To address these bottlenecks, we design and successfully fabricate a novel dual-mode hierarchical(DMH) composite film featuring a micronanofiber network structure, achieved through a straightforward two-step continuous electrospinning process. In cooling mode, it presents a high solar reflectivity of up to 97.7% and an excellent atmospheric transparent window(ATW) infrared emissivity of up to 98.9%. Noted that this DMH film could realize a cooling of 8.1 ℃ compared to the ambient temperature outdoors. In heating mode, it also exhibits a high solar absorptivity of 94.7% and heats up to 11.9 ℃ higher than black cotton fabric when utilized by individuals. In practical application scenarios, a seamless transition between efficient cooling and heating is achieved by simply flipping the film. More importantly, the DMH film combining the benefits of composites demonstrates portability, durability, and easy-cleaning, promising to achieve large-scale production and use of thermally managed textiles in the future. The energy savings offered by film applications provide a viable solution for the early realization of carbon neutrality.
基金the National Natural Science Foundation of China(51708004)Beijing Youth Teaching Master Team Construction Project(108051360023XN261)Yuyou Talent Training Program of North China University of Technology(215051360020XN160/009).
文摘The landscape environment of urban blocks plays a significant role in improving the comfort of urban thermal environment and promoting green and high-quality development.The 342 papers related to the research on the impact of urban block landscape environment on thermal comfort in China,collected by CNKI(China National Knowledge Infrastructure)from 2002 to 2022,are used as the research object.Through bibliometric statistical analysis,LLR algorithm,and cluster analysis,the current research status of the impact of urban block landscape environment on thermal comfort in China is analyzed and processed,and its external characteristics are identified.Using the information visualization software CiteSpace,the research topics in the field of the impact of urban block landscape environment on thermal comfort are presented in the form of knowledge graphs.Through co-occurrence analysis of keywords and trend of word frequency changes,the development trends of research hotspots and cutting-edge fields of the impact of urban block landscape environment on thermal comfort are determined,hoping to provide reference for future research in this field.
文摘Thermal comfort evaluations for Yuexiu Park,Lushan Park,and Baiyun Lake Park in Guangzhou were conducted using field meteorological data collection,visitor questionnaires,and literature reviews.It analyzed the impact of green coverage,water body layout,and facility configuration on thermal comfort.The results showed that good green and water body design effectively lowered the temperature in the park and improved the thermal comfort of visitors,but the insufficient facility configuration in some open areas affected the experience.The visitor’s experience is closely related to the natural environment and facility layout of the park.Therefore,in the future,park design should pay more attention to the rational configuration of shading,ventilation,and cooling facilities to improve thermal comfort,and encourage citizens to participate in the construction and management of parks to improve ecological quality and user experience.This study provides a reference for the improvement of thermal comfort in urban parks in Guangzhou and aims to promote the sustainable and human-oriented development of urban park design.
文摘This work falls within the context of reducing energy consumption in Côte d’Ivoire. As the building sector is one of the energy consumers worldwide, it could be a major source of energy savings. A major source of energy savings. With this in mind thermal comfort in buildings in Côte d’Ivoire (Abidjan) in order to determine (Abidjan) to determine thermal comfort conditions. To carry out study, measurement campaigns were carried out in various buildings. These measured parameters were used to calculate comfort indices such as PMV, PDD, SET and operating temperature. A correlation was then made between the PMV index and the operating temperature, then between the SET and the operating temperature to determine the thermoneutrality temperature and the different thermal comfort thermal comfort ranges. The PMV gave a thermoneutrality temperature of 24.87˚C in the rainy season and a thermoneutrality temperature of 25.15˚C during the dry season. In addition, the SET gave comfort ranges, with values ranging from 23.23˚C to 25.70˚C in the rainy season and 23.35˚C to 26.08˚C in the dry season. In addition, the acceptability predicted by the PDD showed that in the rainy season, the premises were more acceptable than in the dry season.
文摘Buildings constructed with modern materials (cement blocks, sheet metal, reinforced concrete, etc.) in the Sahelian zone often generate excessive electricity consumption and consequently very high electricity bills. This study is a contribution to the development of new building types based on the principle of bioclimatic construction. The aim is to find materials suited to the Sahelian climate and improve thermal comfort. To this end, an experimental study of the hygrothermal behavior of a bioclimatic building prototype with a domed roof is being carried out. Site meteorological data, air temperature and relative humidity of the building’s internal environment were measured for three climatic seasons in Burkina Faso. The data acquisition system consists of thermocouples, solarimeters and humidity meters, and the data are processed using Excel and Origin Pro software. The results show that, despite the high temperature values (between 36˚C and 39˚C) of the internal environment measured in the hot season, good thermal performance is achieved, in particular an average phase shift of 7.17 h and an average damping of 10.81˚C. The dome-roofed building could therefore contribute to limiting heat transmission to the building interior, improving thermal comfort all year round. Analysis of humidity profiles shows that indoor humidity varies between 66% and 80% for the September period, and between 44% and 69% for the January period. The high values of internal ambient humidity could be reduced by very good ventilation of the building. This study shows that the proposed bioclimatic building prototype with domed roof could be integrated into the Sahelian habitat.
文摘Compressed earth blocks (CEB) are an alternative to cement blocks in the construction of wall masonry. However, the optimal architectural construction methods for adequate thermal comfort for occupants in hot and arid environments are not mastered. This article evaluates the influence of architectural and constructive modes of buildings made of CEB walls and concrete block walls, to optimize and compare their thermal comfort in the hot and dry tropical climate of Ouagadougou, Burkina Faso. Two identical pilot buildings whose envelopes are made of CEB and concrete blocks were monitored for this study. The thermal models of the pilot buildings were implemented in the SketchUp software using an extension of EnergyPlus. The models were empirically validated after calibration against measured thermal data from the buildings. The models were used to do a parametric analysis for optimization of the thermal performances by simulating plaster coatings on the exterior of walls, airtight openings and natural ventilation depending on external weather conditions. The results show that the CEB building displays 7016 hours of discomfort, equivalent to 80.1% of the time, and the concrete building displays 6948 hours of discomfort, equivalent to 79.3% of the time. The optimization by modifications reduced the discomfort to 2918 and 3125 hours respectively;i.e. equivalent to only 33.3% for the CEB building and 35.7% for the concrete building. More study should evaluate thermal optimizations in buildings in real time of usage such as residential buildings commonly used by the local middle class. The use of CEB as a construction material and passive means of improving thermal comfort is a suitable ecological and economical option to replace cementitious material.
基金Sponsored by General Project of Natural Science Foundation of Beijing City(8202017)Youth Talent Support Program of 2018 Beijing Municipal University Academic Human Resources Development(PXM2018_014212_000043).
文摘With the continuous intensification of the global greenhouse effect,thermal comfort has become a highly concerned issue in the living environment.The study explores the influencing factors and improvement strategies of urban street thermal comfort.The urban heat island effect,environmental parameters,building layout,and green planting all have a significant impact on the thermal comfort of streets.Improvement strategies include optimizing cultivating pattern of plants,adjusting street layout,and improving paving materials of road.The multi-layer vegetation structure provides green shade,reduces local temperature,and humidifies the surrounding environment.It should adjust the street orientation and aspect ratio to provide sunlight and ventilation,and reduce ambient temperature.Paving materials with low reflectivity and light color and permeable underlying surface should be chosen to reduce heat absorption,increase shading and greenery,and improve thermal comfort.
文摘The purpose of this study is to experimentally analyze the thermal behavior of the walls of a prototype experimental house. A Datalogger and thermocouples were used on the experimental house to determine the temperatures of the exterior and interior walls. Also, “MSR” type HygroPuce was used to determine the exterior and interior temperatures and relative humidity of the habitat. The results show that a wall made of bio-based materials with a mixture of “earth + Hibiscus cannabinus L. fibers” allows reducing the fluctuations of the interior temperatures. We observe the peaks of temperatures on the external walls at 11:00 am and for the interior walls, the peaks are observed at 5:00 pm. The maximum thermal phase shift between the peaks of the external and internal temperatures is about 7.5 hours, and the maximum damping factor is 0.9. Also, we note that the thermal performance of the material used in the design of the envelope of the house is determined by the improvement of the response of the envelope in front of the external thermal solicitations.
基金The National Natural Science Foundation of China(No.5087125)
文摘The local skin temperatures of 22 subjects at air temperatures of 21,24,26,29 ℃ are measured,and the mean skin temperatures are calculated by ten skin temperature measuring points.The thermal comfort levels and the thermal sensations of these subjects are also investigated by a questionnaire.The Mahalanobis distance discrimination method is applied to establish the evaluation model for the thermal comfort based on the mean skin temperature.The experimental results indicate that the difference of the mean skin temperatures between the comfort level and the discomfort level is significant.Using the evaluation model,the mean skin temperature at the thermal comfort level is 32.6 to 33.7 ℃,and the thermal comfort levels of 72% of the subjects are correctly evaluated.The accuracy of the evaluation model can be improved when the effects of sex of the subject on the mean skin temperature and the thermal comfort are considered.It can be concluded that the mean skin temperature can be used as an effective physiological indicator to evaluate human thermal comfort in a steady thermal environment.
基金The National Natural Science Foundation of China(No.50838003)the National Key Technology R&D Program of China during the 11th Five-Year Plan Period(No.2006BAJ02A06)
文摘This paper introduces a field measurement of an indoor thermal environment in rural housing in suburban Beijing from December 2008 to March 2009.The indoor environment parameters such as air temperature,mean radiant temperature(MRT),airflow velocity and relative humidity are measured.A questionnaire survey of the occupants' thermal sensations in these surveyed houses is conducted and their daily activities and clothing conditions are recorded.The results show that the thermal neutral temperature of rural housing is 18.4 ℃,and the lower limit of acceptable temperature range can be extended to 10.9 ℃.The comfortable indoor temperature is affected by the occupants' clothing and lifestyle.Therefore,the indoor temperature standards of space heating for suburban housing cannot be simply duplicated from that for urban housing.Compared with occupants in suburban Beijing,it is found that the occupants in rural Hunan province feel colder at the same operative temperature due to the high relative humidity in Hunan province.
基金The National Key Technology R&D Program of Chinaduring the 11th Five-Year Plan Period(No.2008BAJ12B05)
文摘Field measurements on thermal comfort were carried out in a building with double-skin faade from January 14th to 16th,2009.Data are obtained by measurements of physical parameters and a questionnaire survey is conducted at the same time in 27 offices of the building.The subjective survey involves questions on demographic information of the occupants,health status,environmental comfort conditions and acceptance.A total of 150 occupants are investigated and 131 questionnaires are completed.The statistical data presents the distributions of predicted mean vote,mean thermal sensation vote,mean thermal comfort vote,thermal acceptability,etc.The results show that low relative humidity is the main reason causing thermal discomfort.The greatest discomfort is dry mouth and eye dryness which are caused by low relative humidity.The females are verified to be more sensitive than the males.Meanwhile,a double-skin faade represents a good noise insulation effect while the glare problem is still unresolved.
基金The National Natural Science Foundation of China(No. 51036001 )the Natural Science Foundation of Jiangsu Province(No. BK2010043)
文摘A new ground source heat pump system combined with radiant heating/cooling is proposed, and the principles and the advantages of the system are analyzed. A demonstration of the system is applied to a rebuilt building: Xijindu exhibition hall, which is located in Zhenjiang city in China. Numerical studies on the thermal comfort and energy consumption of the system are carded out by using TRNSYS software. The results indicate that the system with the radiant floor method or the radiant ceiling method shows good thermal comfort without mechanical ventilation in winter. However, the system with either of the methods should add mechanical ventilation to ensure good comfort in summer. At the same level of thermal comfort, it can also be found that the annual energy consumption of the radiant ceiling system is less than that of the radiant floor system.
文摘In this paper,experimental and numerical studies of heat transfer in a test local of side H=0.8 m heated from below are presented and compared.All the walls,the rest of the floor and the ceiling are made from plywood and polystyrene in sandwich form(3 mmplywood-3 cm polystyrene-3 mmplywood)just on one of the vertical walls contained a glazed door(2 H/3×0.15 m).This local is heated during two heating cycles by a square plate of iron the width L=0.6 H,which represents the heat source,its temperature Th is controlled.The plate is heated for two cycles by an adjustable set-point heat source placed just down the center of it.For each cycle,the heat source is switched“on”for 6 h and switched“off”for 6 h.The outdoor air temperature is kept constant at a low temperature Tc<Th.All measurements are carried out with k-type thermocouples and with flux meters.Results will be qualitatively presented for two cycles of heating in terms of temperatures and heat flux densitiesϕfor various positions of the test local.The temperature evolution of the center and the profile of the temperature along the vertical centerline are compared by two dimensions simulation using the lattice Boltzmann method.The comparison shows a good agreement with a difference that does not exceed±1℃.
文摘Buildings constructed using modern materials such as cement are energy-intensive, facilitate heat transfer and thus promote warming inside the building. However, the Sudano-Sahelian regions have a hot climate occupying a large period of the year, thus requiring not only sustainable construction materials, but also which provide thermal comfort in the building by limiting the energy demand for air conditioning. These qualifications are important for sub-Saharan African countries in general and those of the Sudano-Sahelian zone in particular, which need ecological materials with good thermal performance to limit heating inside buildings. This study is an energy recovery of agricultural waste in buildings with a view to offering the populations of the northern regions of Cameroon suitable materials at lower cost for the construction of buildings. The soil used for this study was extracted from the locality of Yagoua where the populations make abundant use of mud bricks. Fonio waste was incorporated at low levels into the earth bricks, particularly at 0%, 1%, 2%, 3%, and 4%, with a view to strengthening their thermophysical and mechanical properties. The results obtained indicate that earth bricks reinforced with 4% waste showed better thermal and mechanical insulation properties compared to other formulations with an improvement of 16% and 78% respectively compared to the unreinforced samples. This research allows us to conclude that fonio waste can be used practically without expense in the building with a view to its energy recovery and will promote not only thermal comfort and the limitation of the energy supply for air conditioning, but the construction of more sustainable buildings with a cleaner environment.
文摘There is a huge amount of energy savings potential in public building sector that has yet to be realized.By prioritizing energy efficiency in its own buildings and thus promoting the development of required knowledge in terms of new technology and construction methods,the public sector will lead the way in efforts to increase the rate of renovations.The low-cost insulation strategies and a comparison of cost with existing insulation materials has been described in this study.We have repeatedly faced energy crises and will continue to do so in the future if appropriate action is not taken in a timely manner.Properly implementing energy-saving initiatives in for achieving thermal comfort in buildings as well as reducing the energy costs would undoubtedly inspire the residential sector,resulting in significant reductions in energy usage.Simulations were carried out to study insulation layers on various building components like exterior walls,floor and roofs,generating different scenarios for a building as a base model,which were then compared and analysed to verify the literature used to develop the cases.The proposed recommendations,which have been validated,are certain to increase building energy efficiency,achieve thermal comfort in low cost than what is currently being used.
基金supported by National Natural Science Foundation of China(Grant No.51375170)Open Fund of State Key Lab of Environmental Adaptability for Industrial Products of China
文摘The existing investigations on thermal comfort mostly focus on the thermal environment conditions, especially of the air-flow field and the temperature distributions in vehicle cabin. Less attention appears to direct to the thermal comfort or thermal sensation of occupants, even to the relationship between thermal conditions and thermal sensation. In this paper, a series of experiments were designed and conducted for understanding the non-uniform conditions and the occupant's thermal responses in vehicle cabin during the heating period. To accurately assess the transient temperature distribution in cabin in common daily condition, the air temperature at a number of positions is measured in a full size vehicle cabin under natural winter environment in South China by using a discrete thermocouples network. The occupant body is divided into nine segments, the skin temperature at each segment and the occupant's local thermal sensation at the head, body, upper limb and lower limb are monitored continuously. The skin temperature is observed by using a discrete thermocouples network, and the local thermal sensation is evaluated by using a seven-point thermal comfort survey questionnaire proposed by American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc(ASHRAE) Standard. The relationship between the skin temperature and the thermal sensation is discussed and regressed by statistics method. The results show that the interior air temperature is highly non-uniform over the vehicle cabin. The locations where the occupants sit have a significant effect on the occupant's thermal responses, including the skin temperature and the thermal sensation. The skin temperaWa-e and thermal sensation are quite different between body segments due to the effect of non-uniform conditions, clothing resistance, and the human thermal regulating system. A quantitative relationship between the thermal sensation and the skin temperature at each body segment of occupant in real life traffic is presented. The investigation result indicates that the skin temperature is a robust index to evaluate the thermal sensation. Applying the skin temperature to designing and controlling parameters of the heating, ventilation and air conditioning(HVAC) system may benefit the thermal comfort and reducing energy consumption.
基金Project(50838009) supported by the National Natural Science Foundation of China
文摘To explore the thermal responses under the non-thermal equilibrium cold environmental conditions,a laboratory study was conducted in climate chamber.The local skin temperatures and thermal sensation of 20 subjects were recorded at 10 min intervals for 90 min under air temperatures of 7.4,9.1,11 and 15 °C.The results show that both local skin temperatures and mean skin temperature decrease not only with the drop of ambient air temperature but also with the exposure time.Local thermal sensation and overall the thermal sensation have the similar temperature-varying and time-varying characteristics.Predicted mean vote(PMV) model cannot correctly predict the thermal sensation under non-thermal equilibrium cold environment.The correlation between local thermal sensation and local skin temperatures shows that thermal sensation is closely related to skin temperature.Skin temperature is an effective indicator of thermal sensation.A linear relationship model between overall thermal sensation and mean skin temperature,considering both ambient temperature and exposure time,was established in the non-thermal equilibrium cold environment,which makes the evaluation of thermal sensation more objective.
基金The work was supported by the Youth Science Fund Project approved by the Youth Innovation Promotion Association of the Chinese Academy of Sciences under Grant 2020237in part by the National Natural Science Foundation of China under Grant 4170121.
文摘Planting trees along urban streets is one of the most important strategies to improve the urban thermal environment.However,the net impacts of urban street trees on human thermal comfort and physiological parameters are still less clear.On three similar east-west orientated streets with different degrees of tree cover-low(13%),medium(35%),and high(75%),urban microclimatic parameters and human physiological indices for six male students were simultaneously measured on three cloudless days in summer 2018.The results show that the differences in tree cover were predominant in influencing urban thermal environment and comfort.The street with the highest tree cover had significantly lower physiological equivalent temperature(PET) and more comfortable than the other two streets.The frequency of strong heat stress(PET> 35℃) was 64%,11 %,and 0%,respectively,for streets with low,medium,and high tree cover.For the six male university students,human physiological indices varied greatly across the three streets with different tree cover.Systolic blood pressure,diastolic blood pressure,and pulse rate increased with decreasing tree cover.The results also suggest that urban thermal environment and comfort had considerable impact on human physiological parameters.Our study provides reasons for urban planners to plant trees along streets to improve the thermal environment and promote urban sustainability.