[Objective] The aim was to develop a rapid, simple method for determination of chromium and zinc in soil samples by flame atomic absorption spectrometry.[Method] The method for determination of Cr and Zn in soil by co...[Objective] The aim was to develop a rapid, simple method for determination of chromium and zinc in soil samples by flame atomic absorption spectrometry.[Method] The method for determination of Cr and Zn in soil by combined flame atomic absorption spectrometry and microwave digestion was used. [Result] The concentration curve was linear within the range of 0-0.8 mg/L for Cr and 0-0.8 mg/L for Zn, the detection limits of Cr and Zn was 0.0025 mg/L and 0.002 3 mg/L, respectively. Recoveries of 102.4%-103.2% for Cr and 97.7%-98.3% for Zn were obtained for there soil samples. [Conclusion] The proposed method has the advantages of simple operation, high sensitivity, and high efficiency; it was successfully used for determination of Cr and Zn in soil samples.展开更多
[Objective] This study aimed to analyze the contents of trace elements in potatoes from different production areas in Qinghai Province. [Method] By flame atomic absorption spectrometry (FAAS), the contents of variou...[Objective] This study aimed to analyze the contents of trace elements in potatoes from different production areas in Qinghai Province. [Method] By flame atomic absorption spectrometry (FAAS), the contents of various trace elements in potatoes were determined. [Result] Potatoes contain abundant trace elements such as Cu, Zn, Fe, Mn, Ca, K and Mg. To be specific, the contents of Ca, K and Mg were relatively high. [Conclusion] By using FAAS, the relative standard deviation was 1.17%-2.75% and the recovery rate was 97%-99.5%, indicating accurate and reli-able results with high precision.展开更多
A new method based on the cloud point extraction(CPE) for separation and preconcentration of nickel(Ⅱ) and its subsequent determination by graphite furnace atomic absorption spectrometry(GFAAS) was proposed, 8-...A new method based on the cloud point extraction(CPE) for separation and preconcentration of nickel(Ⅱ) and its subsequent determination by graphite furnace atomic absorption spectrometry(GFAAS) was proposed, 8-hydroxyquinoline and Triton X-100 were used as the ligand and surfactant respectively. Nickel(Ⅱ) can form a hy-drophobic complex with 8-hydroxyquinoline, the complex can be extracted into the small volume surfactant rich phase at the cloud point temperature(CPT) for GFAAS determination. The factors affecting the cloud point extraction, such as pH, ligand concentration, surfactant concentration, and the incubation time were optimized. Under the optimal conditions, a detection limit of 12 ng/L and a relative standard deviation(RSD) of 2.9% were obtained for Ni(Ⅱ) determination. The enrichment factor was found to be 25. The proposed method was successfully applied to the determination of nickel(Ⅱ) in certified reference material and different types of water samples and the recovery was in a range of 95%―103%.展开更多
In this study we investigated the enrichment ability of oxidized multiwalled carbon nanotubes (MWCNTs) and established a new method for the determination of trace cadmium in environment with flame atomic absorption ...In this study we investigated the enrichment ability of oxidized multiwalled carbon nanotubes (MWCNTs) and established a new method for the determination of trace cadmium in environment with flame atomic absorption spectrometry. The MWCNTs were oxidized by potassium permanganate under appropriate conditions before use as preconcentration packing. Parameters influencing the recoveries of target analytes were optimized. Under optimal conditions, the target analyte exhibited a good linearity (R^2=0.9992) over the concentration range 0.5-50 ng/ml. The detection limit and precision of the proposed method were 0.15 ng/ml and 2.06%, respectively. The proposed method was applied to the determination of cadmium in real-world environmental samples and the recoveries were in the range of 91.3%-108.0%. All these experimental results indicated that this new procedure could be applied to the determination of trace cadmium in environmental waters.展开更多
A procedure for the preconcentration of copper was described in this paper using multi-walled carbon nanotubes (MWCNTs) oxidized by potassium permanganate as the adsorbent for the enrichment of trace copper in water s...A procedure for the preconcentration of copper was described in this paper using multi-walled carbon nanotubes (MWCNTs) oxidized by potassium permanganate as the adsorbent for the enrichment of trace copper in water samples. Important parameters, such as the sample pH, the concentration and volume of eluent, sample flow rate and volume, and interference of coexisting ions, were investigated. The obtained results indicated that proposed method possessed an excellent analytical performance. The linear range, the detection limit, and precison (RSD) were 1–100 ng/mL (R(2) = 0.9993), 0.32 ng/mL and 2.88%, respectively. The results showed that copper could be adsorbed quantitatively on the pretreated MWCNTs with potassium permanganate, and proposed method was very useful in the monitoring of copper in the environment.展开更多
The effects of matrix silicate and experimental conditions on the determination of iron in flame atomic absorption spectrometry (FAAS) were investigated. It was found that boric acid as a matrix modifier obviously e...The effects of matrix silicate and experimental conditions on the determination of iron in flame atomic absorption spectrometry (FAAS) were investigated. It was found that boric acid as a matrix modifier obviously eliminated silicate interference. Under the optimum operating conditions, the determination results of iron in layered crystal sodium disilicate and sodium silicate samples by FAAS were satisfactory. The linear range of calibration curve is 0-10.5 μg.mL^-1, the relative standard deviation of method is 1.2%-2.2%, the recovery of added iron is 96.0%- 101%, the sensitivity is 0.19 μg.mL^-l and the detection limit is 77 ng.mL^-1. The effect of the determination of iron of the standard curve method, standard addition calibration and colorimetry method was the same, but the first has the merits of rapid sample preparation, reduced contamination risks and fast analysis.展开更多
A new method is proposed for the preconcentration of vanadium(Ⅴ) with crosslinked chitosan (CCTS) and determination by graphite furnace atomic absorption spectrometry (GFAAS). The adsorption rate of vanadium(Ⅴ) by C...A new method is proposed for the preconcentration of vanadium(Ⅴ) with crosslinked chitosan (CCTS) and determination by graphite furnace atomic absorption spectrometry (GFAAS). The adsorption rate of vanadium(Ⅴ) by CCTS was 97% at pH 4.0, and vanadium(Ⅴ) was eluted from crosslinked chitosan with 2 mL 2.0 mol·L -1 chlorhydric acid and determined by GFAAS. The detection limit (3σ,n=7) for vanadium(Ⅴ) was 4.8×1 0 -12g and the relative standard deviation (R.S.D) at concentration level of 2.6 μg·L -1 is less than 3.6%. The method shows a good selectivity and high sensitivity, and it was applied to determination of vanadium(Ⅴ) in oyster and water samples. The analytic recoveries are (97±5)%.展开更多
A method is described for the direct determination of iron in high purity sodium fluoride using graphite furnace atomic absorption spectrometry. Interferences caused by the matrix are investigated. It is shown that th...A method is described for the direct determination of iron in high purity sodium fluoride using graphite furnace atomic absorption spectrometry. Interferences caused by the matrix are investigated. It is shown that the ashing temperature can be increased to 1 400°C and matrix interferences eliminated, the sensitivity of iron increased in 1. 27 fold by the addition of nickel nitrate. The method is applied to the determination of iron in sodium fluoride and satisfactory results are obtained.展开更多
The liquid phase microextraction (LPME) was combined with the modified Graphite furnace atomic absorption spectrometry (GF-AAS) for determination of lead in the water and solid samples. In a preconcentration step, lea...The liquid phase microextraction (LPME) was combined with the modified Graphite furnace atomic absorption spectrometry (GF-AAS) for determination of lead in the water and solid samples. In a preconcentration step, lead was extracted from a 2 ml of its aqueous sample in the pH = 5 as lead-Pyrimidine-2-thiol cationic complex into a 4 μl drop of 1,2 dichloroethane and ammonium tetraphenylborate as counter ion immersed in the solution. In the drop, the lead-Pyrimidine-2-thiol ammonium tetraphenylborate ion associated complex was formed. After extraction, the microdrop was retracted and directly transferred into a graphite tube modified by [W.Pd.Mg] (c). Some effective parameters on extraction and complex formation, such as type and volume of organic solvent, pH, concentration of chelating agent and counter ion, extraction time, stirring rate and effect of salt were optimized. Under the optimum conditions, the enrichment factor and recovery were 525% and 94%, respectively. The calibration graph was linear in the range of 0.01 - 12 μg?L–1 with correlation coefficient of 0.9975 under the optimum conditions of the recommended procedure. The detection limit based on the 3Sb criterion was 0.0072 μg?L–1 and relative standard deviation (RSD) for ten replicate measurement of 0.1 μg?L–1 and 0.4 μg?L–1 lead was 4.5% and 3.8% respectively. The characteristic concentration was 0.0065 μg?L–1 equivalent to a characteristic mass of 26 fg. The results for determination of lead in reference materials, spiked tap water and seawater demonstrated the accuracy, recovery and applicability of the presented method.展开更多
A simple on-line sonodigestion system was successfully used for breakdown organic nickel complexes in environmental waters acidified with diluted nitric acid prior to flow injection total dissolved nickel preconcentra...A simple on-line sonodigestion system was successfully used for breakdown organic nickel complexes in environmental waters acidified with diluted nitric acid prior to flow injection total dissolved nickel preconcentration in a microcolumn containing a chelating resin (Chelite Che with iminodiacetic acid groups) and determination by flame atomic absorption spectrometry. For the determination of the dissolved labile nickel fraction, microcolumns packed with the chelating resin were loaded in-situ with the sample without sample pH modification, and once in the laboratory were inserted in the flow injection device where nickel elution-detection was carried out. The performance of the chelating resin was investigated in order to elucidate its behavior in the presence of dissolved nickel species. The results obtained reveal that the resin, at the experimental employed conditions, retained only dissolved free nickel ions and nickel bound to weak complexes (labile fraction). The figures of merit for determinations in both nickel fractions are given and the obtained values are discussed. The speciation scheme is applied to the analysis of nickel in river and seawater samples collected in Galicia (Northwest, Spain). The results of fractionation showed that Ni are mainly in the dissolved labile fraction in river water, while in seawater samples analyzed was mainly present in the organic fraction.展开更多
In general, biological organisms have the ability to absorb a specific element selectively. Holcombe and his co-workers reported that copper, nickel and cobalt could be separated from riverine and sea-water samples an...In general, biological organisms have the ability to absorb a specific element selectively. Holcombe and his co-workers reported that copper, nickel and cobalt could be separated from riverine and sea-water samples and cadmium from river water samples by unicellular green algae and were determined by slurry GFAAS. Dar-展开更多
[Objectives] The contents of copper and lead in the soil of the Yellow River Wetland were determined by flame atomic absorption spectrometry, which provides a theoretical basis for the treatment of soil pollution. [Me...[Objectives] The contents of copper and lead in the soil of the Yellow River Wetland were determined by flame atomic absorption spectrometry, which provides a theoretical basis for the treatment of soil pollution. [Methods] The soil was digested with a concentrated nitric acid-hydrofluoric acid-perchloric acid system, and the contents of heavy metals such as copper and lead in the Yellow River Wetland of Shaanxi Province were determined by flame atomic absorption spectrometry. [Results] The correlation coefficients reached 0.999 5 in the range of 0.00-1.00 mg/L, indicating good linearity. [Conclusions] The method is simple in operation, good in reproducibility, high in sensitivity to most elements, and can be widely used.展开更多
[ Objective] A method was established to determine trace Pb in soil by graphite furnace atomic absorption spectrometry. [ Method] The pre-treatment of soil sample was conducted by nitric acid -perchloric acid -hydroch...[ Objective] A method was established to determine trace Pb in soil by graphite furnace atomic absorption spectrometry. [ Method] The pre-treatment of soil sample was conducted by nitric acid -perchloric acid -hydrochloric acid system. Palladium nitrate was added to eliminate ma- trix interference. Digestion acid, ashing and atomization temperature of the sample were selected. The operating parameters of instrument and tem- perature-rise program of graphite furnace were optimized. National standard matter was used to verify accuracy of the method. [Result] The detec- tion limit for Pb was 0.27 μg/g by graphite furnace atomic absorption spectrometry, and the recovery rate was 91.0% -96.1%. [ Conclusion The method had rapid analysis velocity, high sensitivity, less interference and easy operation. When applied to determination of trace Pb in the soil, the method obtained satisfactory results.展开更多
In graphite furnace atomic absorption spectrometry (GF-AAS), the atomization process of lead occurring in graphite atomizers with/without a platform plate was investigated when palladium was added to an iron-matrix sa...In graphite furnace atomic absorption spectrometry (GF-AAS), the atomization process of lead occurring in graphite atomizers with/without a platform plate was investigated when palladium was added to an iron-matrix sample solution containing trace amounts of lead. Absorption profiles of a lead line were meas- ured at various compositions of iron and palladium. Variations in the gas temperature were also estimated with the progress of atomization, by using a two-line method under the assumption of a Boltzmann distribu- tion. Each addition of iron and palladium increased the lead absorbance in both the atomizers, indicating that iron or palladium became an effective matrix modifier for the determination of lead. Especially, palladium played a significant role for controlling chemical species of lead at the charring stage in the platform-type atomizer, to change several chemical species to a single species and eventually to yield a dominant peak of the lead absorbance at the atomizing stage. Furthermore, the addition of palladium delayed the peak after the gas atmosphere in the atomizer was heated to a higher temperature. These phenomena would be because the temperature of the platform at the charring stage was elevated more slowly compared to that of the furnace wall, and also because a thermally-stable compound, such as a palladium-lead solid solution, was produced by their metallurgical reaction during heating of the charring stage. A platform-type atomizer with palladium as the matrix modifier is recommended for the determination of lead in GF-AAS. The optimum condition for this was obtained in a coexistence of 1.0 × 10–2 g/dm3 palladium, when the charring at 973 K and then the atomizing at 3073 K were conducted.展开更多
Lead and cadmium in herbal medicines are highly toxic to living organisms even in low concentrations. An effective method is developed for analysis of trace lead and cadmium in Chinese herbal medicines and their decoc...Lead and cadmium in herbal medicines are highly toxic to living organisms even in low concentrations. An effective method is developed for analysis of trace lead and cadmium in Chinese herbal medicines and their decoctions by graphite furnace atomic absorption spectrometry (GFAAS). The effects of analytical conditions on absorbance were investigated and optimized. A water-dissolving capability for Pb and Cd was investigated, and the contents of different species in five Chinese herbal medicines and their decoctions were analyzed. The content ratios (kow) of n-octanol-soluble Pb or Cd to water-soluble Pb or Cd were evaluated, and the distribution of Pb and Cd in water decoction at stomach and intestine acidities was developed, in the first time. The contents of water-soluble Pb and Cd, n-octanol-soluble Pb and Cd, and their content ratios were related with the kind of medicine and the acidity of the decoction. The proposed method has the advantages of simple operation, high sensitivity and high speed, with 3 σ detection limits of 4.2 pg for Pb and 0.1 pg for Cd.展开更多
A direct analysis method combining an iminodiacetate extraction disk (IED) with graphite furnace atomic absorption spectrometry was developed for the determination of Co, Ni, Cu, Cd, Sn, Pb, and Bi at sub-ppb levels i...A direct analysis method combining an iminodiacetate extraction disk (IED) with graphite furnace atomic absorption spectrometry was developed for the determination of Co, Ni, Cu, Cd, Sn, Pb, and Bi at sub-ppb levels in water. A 100 mL water sample was adjusted to pH 5.6 with nitric acid and a 1 mol?L–1 ammonium acetate solution, and then passed through an IED (diameter, 47 mm;effective filtering diameter, 35 mm) at a flow rate of 80 - 100 mL?min–1 to preconcentrate seven analytes. The IED was dried at 100?C for 20 min in an electric oven, and 110 - 145 small disks, each 2 mm in diameter, were punched out from the IED. A small disk was introduced into the graphite furnace and atomized according to a heating program. For Cd, Sn, Pb, and Bi measurements, Pd was used as a chemical modifier to enhance the absorbances. Calibration was performed using aqueous standard solutions. The detection limits, corresponding to three times the standard deviation (n = 5) of the blank values, were 0.092 μg·L–1 for Co, 0.12 μg·L–1 for Ni, 0.40 μg·L–1 for Cu, 0.077 μg·L–1 for Cd, 0.92 μg·L–1 for Sn, 0.61 μg·L–1 for Pb, and 0.80 μg·L–1 for Bi with an enrichment factor of 140 using a 100-mL water sample. A spike test for the seven analytes in tap water, rainwater, river water, and mineral drinking water showed quantitative recoveries (93% - 108%).展开更多
Tricalcium phosphate Anhydrous Powder typically contains less than 10 ppm (mg/Kg) (w/w) manganese. This level can be determined utilizing Flame Atomic Absorption Spectrometer (AAS) and standard based on known standard...Tricalcium phosphate Anhydrous Powder typically contains less than 10 ppm (mg/Kg) (w/w) manganese. This level can be determined utilizing Flame Atomic Absorption Spectrometer (AAS) and standard based on known standards. A number of analytical methods are presently used for the analysis of metals in the biochemical. The instrumental techniques available are Inductively Coupled Plasma (ICP/MS), X-Ray Fluorescence, UV-VIS Spectrophotometry, and Atomic Absorption Spectrometry. Flame AA has gained widespread acceptance as an analytical technique and is used for many applications. In this study, we have determined the amount of manganese metal present in Tricalcium Phosphate (TCP) using Flame Atomic Absorption Spectrophotometer. The method has high precision and accuracy. The percent recovery was found to be 99.8% for spiked sample. The results meet the requirement.展开更多
A simple and reliable method has been developed for separation and preconcentration of trace amounts of copper ions in cereals food for subsequent measurement by flame atomic absorption spectrometry (FAAS). The Cu^2...A simple and reliable method has been developed for separation and preconcentration of trace amounts of copper ions in cereals food for subsequent measurement by flame atomic absorption spectrometry (FAAS). The Cu^2+ ions are adsorbed selectively and quantitatively during the passage. The retained copper ions were desorbed from the potassium tetratitanate whisker with 10.0mL of 2mol/L sulphuric acid solutions as eluent and were determined by FAAS. The linear range was 0.05μg/mL-0.20μg/mL in the original solution with a correlation coefficient of 0.9998. The detection limit of the proposed method is 2. lng/mL in the original solution (3σ, n=9). Determination of copper in standard ions showed that the proposed method has good accuracy (recovery was more than 95%). The method was successfully applied for recovery and determination of copper in cereals food samples展开更多
A flow injection preconcentration system for the flame atomic absorption spectrometric determination of hexavalent chromium has been developed. The method employs on-line preconcentration of Cr(VI) on a minicolumn pac...A flow injection preconcentration system for the flame atomic absorption spectrometric determination of hexavalent chromium has been developed. The method employs on-line preconcentration of Cr(VI) on a minicolumn packed with Cr(VI)-imprinted poly(4-vinyl pyridineco-2-hydroxyethyl methacrylate) placed into a flow injection system. Hexava-lent chromium was eluted with a small volume of diluted hydrochloric acid into the nebulizer-burner system of a flame atomic absorption spectrometer. An enrichment factor of 550 and a 3σ detection limit of 0.04 μg·L-1 along a sampling frequency of 4 h-1 at a sample flow rate of 3.5 mL·min-1. The relative standard deviation is 2.9% for 1 μg·L-1 Cr(VI) (n = 11). The flow injection system proposed has the advantage of being simpler because the use of expensive and sophisticated instruments is avoided. Ease of use, continuous process and selectivity make this method suitable for Cr(VI) determination in different environmental samples such as sea and river waters, soils and sediments.展开更多
基金Supported by Key Fund of Guangxi Academy of Agricultural Sciences(2014JZ01 and2013YZ07)~~
文摘[Objective] The aim was to develop a rapid, simple method for determination of chromium and zinc in soil samples by flame atomic absorption spectrometry.[Method] The method for determination of Cr and Zn in soil by combined flame atomic absorption spectrometry and microwave digestion was used. [Result] The concentration curve was linear within the range of 0-0.8 mg/L for Cr and 0-0.8 mg/L for Zn, the detection limits of Cr and Zn was 0.0025 mg/L and 0.002 3 mg/L, respectively. Recoveries of 102.4%-103.2% for Cr and 97.7%-98.3% for Zn were obtained for there soil samples. [Conclusion] The proposed method has the advantages of simple operation, high sensitivity, and high efficiency; it was successfully used for determination of Cr and Zn in soil samples.
文摘[Objective] This study aimed to analyze the contents of trace elements in potatoes from different production areas in Qinghai Province. [Method] By flame atomic absorption spectrometry (FAAS), the contents of various trace elements in potatoes were determined. [Result] Potatoes contain abundant trace elements such as Cu, Zn, Fe, Mn, Ca, K and Mg. To be specific, the contents of Ca, K and Mg were relatively high. [Conclusion] By using FAAS, the relative standard deviation was 1.17%-2.75% and the recovery rate was 97%-99.5%, indicating accurate and reli-able results with high precision.
基金Supported by the National Natural Science Foundation of China(No.20075009)
文摘A new method based on the cloud point extraction(CPE) for separation and preconcentration of nickel(Ⅱ) and its subsequent determination by graphite furnace atomic absorption spectrometry(GFAAS) was proposed, 8-hydroxyquinoline and Triton X-100 were used as the ligand and surfactant respectively. Nickel(Ⅱ) can form a hy-drophobic complex with 8-hydroxyquinoline, the complex can be extracted into the small volume surfactant rich phase at the cloud point temperature(CPT) for GFAAS determination. The factors affecting the cloud point extraction, such as pH, ligand concentration, surfactant concentration, and the incubation time were optimized. Under the optimal conditions, a detection limit of 12 ng/L and a relative standard deviation(RSD) of 2.9% were obtained for Ni(Ⅱ) determination. The enrichment factor was found to be 25. The proposed method was successfully applied to the determination of nickel(Ⅱ) in certified reference material and different types of water samples and the recovery was in a range of 95%―103%.
基金Project supported by the Hi-Tech Research and Development Program (863) of China (No.2006AA06Z424)Personal Innovation Foundation of Universities in Henan Province (No.[2005]-126)+1 种基金Youth Science Foundation of Henan Normal University (No.2004005)Natural Science Foundation of Henan Province (No.072300460010).
文摘In this study we investigated the enrichment ability of oxidized multiwalled carbon nanotubes (MWCNTs) and established a new method for the determination of trace cadmium in environment with flame atomic absorption spectrometry. The MWCNTs were oxidized by potassium permanganate under appropriate conditions before use as preconcentration packing. Parameters influencing the recoveries of target analytes were optimized. Under optimal conditions, the target analyte exhibited a good linearity (R^2=0.9992) over the concentration range 0.5-50 ng/ml. The detection limit and precision of the proposed method were 0.15 ng/ml and 2.06%, respectively. The proposed method was applied to the determination of cadmium in real-world environmental samples and the recoveries were in the range of 91.3%-108.0%. All these experimental results indicated that this new procedure could be applied to the determination of trace cadmium in environmental waters.
文摘A procedure for the preconcentration of copper was described in this paper using multi-walled carbon nanotubes (MWCNTs) oxidized by potassium permanganate as the adsorbent for the enrichment of trace copper in water samples. Important parameters, such as the sample pH, the concentration and volume of eluent, sample flow rate and volume, and interference of coexisting ions, were investigated. The obtained results indicated that proposed method possessed an excellent analytical performance. The linear range, the detection limit, and precison (RSD) were 1–100 ng/mL (R(2) = 0.9993), 0.32 ng/mL and 2.88%, respectively. The results showed that copper could be adsorbed quantitatively on the pretreated MWCNTs with potassium permanganate, and proposed method was very useful in the monitoring of copper in the environment.
文摘The effects of matrix silicate and experimental conditions on the determination of iron in flame atomic absorption spectrometry (FAAS) were investigated. It was found that boric acid as a matrix modifier obviously eliminated silicate interference. Under the optimum operating conditions, the determination results of iron in layered crystal sodium disilicate and sodium silicate samples by FAAS were satisfactory. The linear range of calibration curve is 0-10.5 μg.mL^-1, the relative standard deviation of method is 1.2%-2.2%, the recovery of added iron is 96.0%- 101%, the sensitivity is 0.19 μg.mL^-l and the detection limit is 77 ng.mL^-1. The effect of the determination of iron of the standard curve method, standard addition calibration and colorimetry method was the same, but the first has the merits of rapid sample preparation, reduced contamination risks and fast analysis.
文摘A new method is proposed for the preconcentration of vanadium(Ⅴ) with crosslinked chitosan (CCTS) and determination by graphite furnace atomic absorption spectrometry (GFAAS). The adsorption rate of vanadium(Ⅴ) by CCTS was 97% at pH 4.0, and vanadium(Ⅴ) was eluted from crosslinked chitosan with 2 mL 2.0 mol·L -1 chlorhydric acid and determined by GFAAS. The detection limit (3σ,n=7) for vanadium(Ⅴ) was 4.8×1 0 -12g and the relative standard deviation (R.S.D) at concentration level of 2.6 μg·L -1 is less than 3.6%. The method shows a good selectivity and high sensitivity, and it was applied to determination of vanadium(Ⅴ) in oyster and water samples. The analytic recoveries are (97±5)%.
文摘A method is described for the direct determination of iron in high purity sodium fluoride using graphite furnace atomic absorption spectrometry. Interferences caused by the matrix are investigated. It is shown that the ashing temperature can be increased to 1 400°C and matrix interferences eliminated, the sensitivity of iron increased in 1. 27 fold by the addition of nickel nitrate. The method is applied to the determination of iron in sodium fluoride and satisfactory results are obtained.
文摘The liquid phase microextraction (LPME) was combined with the modified Graphite furnace atomic absorption spectrometry (GF-AAS) for determination of lead in the water and solid samples. In a preconcentration step, lead was extracted from a 2 ml of its aqueous sample in the pH = 5 as lead-Pyrimidine-2-thiol cationic complex into a 4 μl drop of 1,2 dichloroethane and ammonium tetraphenylborate as counter ion immersed in the solution. In the drop, the lead-Pyrimidine-2-thiol ammonium tetraphenylborate ion associated complex was formed. After extraction, the microdrop was retracted and directly transferred into a graphite tube modified by [W.Pd.Mg] (c). Some effective parameters on extraction and complex formation, such as type and volume of organic solvent, pH, concentration of chelating agent and counter ion, extraction time, stirring rate and effect of salt were optimized. Under the optimum conditions, the enrichment factor and recovery were 525% and 94%, respectively. The calibration graph was linear in the range of 0.01 - 12 μg?L–1 with correlation coefficient of 0.9975 under the optimum conditions of the recommended procedure. The detection limit based on the 3Sb criterion was 0.0072 μg?L–1 and relative standard deviation (RSD) for ten replicate measurement of 0.1 μg?L–1 and 0.4 μg?L–1 lead was 4.5% and 3.8% respectively. The characteristic concentration was 0.0065 μg?L–1 equivalent to a characteristic mass of 26 fg. The results for determination of lead in reference materials, spiked tap water and seawater demonstrated the accuracy, recovery and applicability of the presented method.
文摘A simple on-line sonodigestion system was successfully used for breakdown organic nickel complexes in environmental waters acidified with diluted nitric acid prior to flow injection total dissolved nickel preconcentration in a microcolumn containing a chelating resin (Chelite Che with iminodiacetic acid groups) and determination by flame atomic absorption spectrometry. For the determination of the dissolved labile nickel fraction, microcolumns packed with the chelating resin were loaded in-situ with the sample without sample pH modification, and once in the laboratory were inserted in the flow injection device where nickel elution-detection was carried out. The performance of the chelating resin was investigated in order to elucidate its behavior in the presence of dissolved nickel species. The results obtained reveal that the resin, at the experimental employed conditions, retained only dissolved free nickel ions and nickel bound to weak complexes (labile fraction). The figures of merit for determinations in both nickel fractions are given and the obtained values are discussed. The speciation scheme is applied to the analysis of nickel in river and seawater samples collected in Galicia (Northwest, Spain). The results of fractionation showed that Ni are mainly in the dissolved labile fraction in river water, while in seawater samples analyzed was mainly present in the organic fraction.
文摘In general, biological organisms have the ability to absorb a specific element selectively. Holcombe and his co-workers reported that copper, nickel and cobalt could be separated from riverine and sea-water samples and cadmium from river water samples by unicellular green algae and were determined by slurry GFAAS. Dar-
基金Supported by Scientific Research Program Funded by Shaanxi Provincial Education Department(16JK1275)Fund for Supporting National Undergraduate Scientific and Technological Innovation(16XK046)
文摘[Objectives] The contents of copper and lead in the soil of the Yellow River Wetland were determined by flame atomic absorption spectrometry, which provides a theoretical basis for the treatment of soil pollution. [Methods] The soil was digested with a concentrated nitric acid-hydrofluoric acid-perchloric acid system, and the contents of heavy metals such as copper and lead in the Yellow River Wetland of Shaanxi Province were determined by flame atomic absorption spectrometry. [Results] The correlation coefficients reached 0.999 5 in the range of 0.00-1.00 mg/L, indicating good linearity. [Conclusions] The method is simple in operation, good in reproducibility, high in sensitivity to most elements, and can be widely used.
文摘[ Objective] A method was established to determine trace Pb in soil by graphite furnace atomic absorption spectrometry. [ Method] The pre-treatment of soil sample was conducted by nitric acid -perchloric acid -hydrochloric acid system. Palladium nitrate was added to eliminate ma- trix interference. Digestion acid, ashing and atomization temperature of the sample were selected. The operating parameters of instrument and tem- perature-rise program of graphite furnace were optimized. National standard matter was used to verify accuracy of the method. [Result] The detec- tion limit for Pb was 0.27 μg/g by graphite furnace atomic absorption spectrometry, and the recovery rate was 91.0% -96.1%. [ Conclusion The method had rapid analysis velocity, high sensitivity, less interference and easy operation. When applied to determination of trace Pb in the soil, the method obtained satisfactory results.
文摘In graphite furnace atomic absorption spectrometry (GF-AAS), the atomization process of lead occurring in graphite atomizers with/without a platform plate was investigated when palladium was added to an iron-matrix sample solution containing trace amounts of lead. Absorption profiles of a lead line were meas- ured at various compositions of iron and palladium. Variations in the gas temperature were also estimated with the progress of atomization, by using a two-line method under the assumption of a Boltzmann distribu- tion. Each addition of iron and palladium increased the lead absorbance in both the atomizers, indicating that iron or palladium became an effective matrix modifier for the determination of lead. Especially, palladium played a significant role for controlling chemical species of lead at the charring stage in the platform-type atomizer, to change several chemical species to a single species and eventually to yield a dominant peak of the lead absorbance at the atomizing stage. Furthermore, the addition of palladium delayed the peak after the gas atmosphere in the atomizer was heated to a higher temperature. These phenomena would be because the temperature of the platform at the charring stage was elevated more slowly compared to that of the furnace wall, and also because a thermally-stable compound, such as a palladium-lead solid solution, was produced by their metallurgical reaction during heating of the charring stage. A platform-type atomizer with palladium as the matrix modifier is recommended for the determination of lead in GF-AAS. The optimum condition for this was obtained in a coexistence of 1.0 × 10–2 g/dm3 palladium, when the charring at 973 K and then the atomizing at 3073 K were conducted.
文摘Lead and cadmium in herbal medicines are highly toxic to living organisms even in low concentrations. An effective method is developed for analysis of trace lead and cadmium in Chinese herbal medicines and their decoctions by graphite furnace atomic absorption spectrometry (GFAAS). The effects of analytical conditions on absorbance were investigated and optimized. A water-dissolving capability for Pb and Cd was investigated, and the contents of different species in five Chinese herbal medicines and their decoctions were analyzed. The content ratios (kow) of n-octanol-soluble Pb or Cd to water-soluble Pb or Cd were evaluated, and the distribution of Pb and Cd in water decoction at stomach and intestine acidities was developed, in the first time. The contents of water-soluble Pb and Cd, n-octanol-soluble Pb and Cd, and their content ratios were related with the kind of medicine and the acidity of the decoction. The proposed method has the advantages of simple operation, high sensitivity and high speed, with 3 σ detection limits of 4.2 pg for Pb and 0.1 pg for Cd.
文摘A direct analysis method combining an iminodiacetate extraction disk (IED) with graphite furnace atomic absorption spectrometry was developed for the determination of Co, Ni, Cu, Cd, Sn, Pb, and Bi at sub-ppb levels in water. A 100 mL water sample was adjusted to pH 5.6 with nitric acid and a 1 mol?L–1 ammonium acetate solution, and then passed through an IED (diameter, 47 mm;effective filtering diameter, 35 mm) at a flow rate of 80 - 100 mL?min–1 to preconcentrate seven analytes. The IED was dried at 100?C for 20 min in an electric oven, and 110 - 145 small disks, each 2 mm in diameter, were punched out from the IED. A small disk was introduced into the graphite furnace and atomized according to a heating program. For Cd, Sn, Pb, and Bi measurements, Pd was used as a chemical modifier to enhance the absorbances. Calibration was performed using aqueous standard solutions. The detection limits, corresponding to three times the standard deviation (n = 5) of the blank values, were 0.092 μg·L–1 for Co, 0.12 μg·L–1 for Ni, 0.40 μg·L–1 for Cu, 0.077 μg·L–1 for Cd, 0.92 μg·L–1 for Sn, 0.61 μg·L–1 for Pb, and 0.80 μg·L–1 for Bi with an enrichment factor of 140 using a 100-mL water sample. A spike test for the seven analytes in tap water, rainwater, river water, and mineral drinking water showed quantitative recoveries (93% - 108%).
文摘Tricalcium phosphate Anhydrous Powder typically contains less than 10 ppm (mg/Kg) (w/w) manganese. This level can be determined utilizing Flame Atomic Absorption Spectrometer (AAS) and standard based on known standards. A number of analytical methods are presently used for the analysis of metals in the biochemical. The instrumental techniques available are Inductively Coupled Plasma (ICP/MS), X-Ray Fluorescence, UV-VIS Spectrophotometry, and Atomic Absorption Spectrometry. Flame AA has gained widespread acceptance as an analytical technique and is used for many applications. In this study, we have determined the amount of manganese metal present in Tricalcium Phosphate (TCP) using Flame Atomic Absorption Spectrophotometer. The method has high precision and accuracy. The percent recovery was found to be 99.8% for spiked sample. The results meet the requirement.
基金Imburse Fund of Science and Technology Office (05C26213100474)
文摘A simple and reliable method has been developed for separation and preconcentration of trace amounts of copper ions in cereals food for subsequent measurement by flame atomic absorption spectrometry (FAAS). The Cu^2+ ions are adsorbed selectively and quantitatively during the passage. The retained copper ions were desorbed from the potassium tetratitanate whisker with 10.0mL of 2mol/L sulphuric acid solutions as eluent and were determined by FAAS. The linear range was 0.05μg/mL-0.20μg/mL in the original solution with a correlation coefficient of 0.9998. The detection limit of the proposed method is 2. lng/mL in the original solution (3σ, n=9). Determination of copper in standard ions showed that the proposed method has good accuracy (recovery was more than 95%). The method was successfully applied for recovery and determination of copper in cereals food samples
基金This work has been funded by the Spain’s Ministry of Science and Innovation,within the framework of Project CTQ2009-12282.
文摘A flow injection preconcentration system for the flame atomic absorption spectrometric determination of hexavalent chromium has been developed. The method employs on-line preconcentration of Cr(VI) on a minicolumn packed with Cr(VI)-imprinted poly(4-vinyl pyridineco-2-hydroxyethyl methacrylate) placed into a flow injection system. Hexava-lent chromium was eluted with a small volume of diluted hydrochloric acid into the nebulizer-burner system of a flame atomic absorption spectrometer. An enrichment factor of 550 and a 3σ detection limit of 0.04 μg·L-1 along a sampling frequency of 4 h-1 at a sample flow rate of 3.5 mL·min-1. The relative standard deviation is 2.9% for 1 μg·L-1 Cr(VI) (n = 11). The flow injection system proposed has the advantage of being simpler because the use of expensive and sophisticated instruments is avoided. Ease of use, continuous process and selectivity make this method suitable for Cr(VI) determination in different environmental samples such as sea and river waters, soils and sediments.