Artificial ground freezing of underground mines in cold regions using thermosyphons with air insulation
1
作者 Ahmad F.Zueter Mohammad Zolfagharroshan +1 位作者 Navid Bahrani Agus P.Sasmito 《International Journal of Mining Science and Technology》 SCIE EI CAS CSCD 2024年第5期643-654,共12页
Current practice of underground artificial ground freezing(AGF)typically involves huge refrigeration systems of large economic and environmental costs.In this study,a novel AGF technique is proposed deploying availabl... Current practice of underground artificial ground freezing(AGF)typically involves huge refrigeration systems of large economic and environmental costs.In this study,a novel AGF technique is proposed deploying available cold wind in cold regions.This is achieved by a static heat transfer device called thermosyphon equipped with an air insulation layer.A refrigeration unit can be optionally integrated to meet additional cooling requirements.The introduction of air insulation isolates the thermosyphon from ground zones where freezing is not needed,resulting in:(1)steering the cooling resources(cold wind or refrigeration)towards zones of interest;and(2)minimizing refrigeration load.This design is demonstrated using well-validated mathematical models from our previous work based on two-phase enthalpy method of the ground coupled with a thermal resistance network for the thermosyphon.Two Canadian mines are considered:the Cigar Lake Mine and the Giant Mine.The results show that our proposed design can speed the freezing time by 30%at the Giant Mine and by two months at the Cigar Lake Mine.Further,a cooling load of 2.4 GWh can be saved at the Cigar Lake Mine.Overall,this study provides mining practitioners with sustainable solutions of underground AGF. 展开更多
关键词 Artificial ground freezing Underground mining Sustainable mining THERMOSYPHON Air insulation Cold regions
下载PDF
Performance analyses of two-phase closed thermosyphons for road embankments in the high-latitude permafrost regions
2
作者 WANG Guan-fu LIN Chuang +3 位作者 ZHU Long FENG De-cheng XIN Yang-yang ZHANG Feng 《Journal of Mountain Science》 SCIE CSCD 2023年第11期3138-3153,共16页
Two-phase closed thermosyphons(TPCTs)are widely used in infrastructure constructions in permafrost regions.Due to different climatic conditions,the effectiveness of TPCT will also be different,especially in the extrem... Two-phase closed thermosyphons(TPCTs)are widely used in infrastructure constructions in permafrost regions.Due to different climatic conditions,the effectiveness of TPCT will also be different,especially in the extremely cold region of the Da Xing'anling Mountains.In this study,a series of three-dimensional finite element TPCT embankment models were established based on the ZhanglingMohe highway TPCT test section in Da Xing'anling Mountains,and the thermal characteristics and the cooling effect of the TPCTs were analyzed.The results indicated that the TPCTs installed in the northeastern high-latitude regions is effective in cooling and stabilizing the embankment.The working cycle of the TPCTs is nearly 7 months,and the cooling range of the TPCTs can reach 3 m in this region.However,due to the extremely low temperature,the TPCT generates a large radial gradient in the permafrost layer.Meanwhile,by changing the climate conditions,the same type of TPCT embankment located in the Da Xing'anling Mountains,the Xiao Xing'anling Mountains,and the Qinghai-Tibet Plateau permafrost regions were simulated.Based on the comparison of the climate differences between the Qinghai-Tibet Plateau and Northeast China,the differences in the effectiveness of TPCTs were studied.Finally,the limitations of using existing TPCTs in high-latitude permafrost regions of China were discussed and the potential improvements of the TPCT in cold regions were presented. 展开更多
关键词 PERMAFROST Highway embankment Two-phase closed thermosyphon Numerical simulation Climatic condition Cooling performance
下载PDF
Laboratory test on the combined cooling effect of L-shaped thermosyphons and thermal insulation on high-grade roadway construction in permafrost regions 被引量:3
3
作者 YuanHong Dong,YuanMing Lai,MingYi Zhang,ShuangYang Li State Key Laboratory of Frozen Soil Engineering,Cold and Arid Regions Environmental and Engineering Research Institute,Chinese Academy of Sciences,Lanzhou,Gansu 730000,China. 《Research in Cold and Arid Regions》 2009年第4期307-315,共9页
With the completion of the Qinghai-Tibetan Railway,economic development of related areas has been greatly accelerated.This,in return,calls for building or upgrading more roadways,especially high-grade roadways.In cold... With the completion of the Qinghai-Tibetan Railway,economic development of related areas has been greatly accelerated.This,in return,calls for building or upgrading more roadways,especially high-grade roadways.In cold regions,the thawing of permafrost can induce settlement damage of and even failure to railway (or roadway) embankments.Thermosyphons (self-powered refrigera-tion devices that are used to help keep the permafrost cool) have proved effective in mitigating thaw settlement by maintaining the thermal stability of the embankments.However,for high-grade roadway embankments of great width,stabilizing or cooling ef-fects of traditional geotechnological measures may be limited.To enhance the cooling effect of thermosyphons,an L-shaped thermosyphon was designed.A laboratory test was carried out to study the combined cooling effect of the L-shaped thermosyphon and thermal insulation applying to roadbed construction.The angle between the evaporator and condenser sections of the L-shaped thermosyphon is 134 degrees,and the L-shaped thermosyphon was inserted into the soil at an angle of 5 degrees with the road surface.The tested results show that the L-shaped thermosyphon is effective in removing heat from a roadway in winter.When the ambient air temperature is lower than the soil temperature,the thermosyphon is active and extracts the heat in the soil around it.When the ambient air temperature is higher than the soil temperature,the thermosyphon is inactive,and no heat is in-jected into the soil through the L-shaped thermosyphon.Compared to embankments with straight thermosyphons,the inner parts of the embankments with L-shaped thermosyphons were significantly cooled.It is hoped that the present study would be useful to the application of L-shaped thermosyphons in the construction of high-grade roadways in cold regions. 展开更多
关键词 L-shaped thermosyphon thermal insulation cooling effect foundation soils high-grade roadway
下载PDF
Strengthening effect of crushed rock revetment and thermosyphons in a traditional embankment in permafrost regions under warming climate 被引量:5
4
作者 MEI Qi-Hang CHEN Ji +5 位作者 WANG Jin-Chang HOU Xin ZHAO Jing-Yi ZHANG Shou-Hong DANG Hai-Ming GAO Jia-Wei 《Advances in Climate Change Research》 SCIE CSCD 2021年第1期66-75,共10页
The embankment of the Qinghai-Tibet Railway(QTR)has been experiencing severe problems due to permafrost degradation,especially in warm and ice-rich permafrost regions.Based on ground temperature and deformation data o... The embankment of the Qinghai-Tibet Railway(QTR)has been experiencing severe problems due to permafrost degradation,especially in warm and ice-rich permafrost regions.Based on ground temperature and deformation data of the embankment at location K1497+150 of the QTR in 2006-2018,the thermal regime and deformation process were analysed.The results showed that 1)the degradation rate of permafrost under the embankment was faster than that under the natural site without engineering construction,and 2)the deformation rate of the embankment had exceeded the safety range for the QTR embankment before adopting mitigative measures.In addition,this study evaluated the cooling effect on the underlying permafrost and working mechanism of two strengthening measures.Two measures,crushed rock revetment(CRR)and thermosyphons,were adopted to protect the underlying permafrost from continual degradation.The individual cooling effect of the CRR was not as good as that of the thermosyphons.However,the combination of the two could enhance the protective effects of each on the underlying permafrost,effectively cooling the permafrost and improving the stability of the embankment. 展开更多
关键词 Climate warming PERMAFROST Crushed rock revetment(CRR) thermosyphons SETTLEMENT
原文传递
Causes and detection of coalfield fires, control techniques, and heat energy recovery: A review 被引量:3
5
作者 He-tao Su Fu-bao Zhou +2 位作者 Bo-bo Shi Hai-ning Qi Jin-chang Deng 《International Journal of Minerals,Metallurgy and Materials》 SCIE EI CAS CSCD 2020年第3期275-291,共17页
Coalfield fires are considered a global crisis that contributes significantly to environmental destruction and loss of coal resources and poses a serious threat to human safety and health. In this paper, research rela... Coalfield fires are considered a global crisis that contributes significantly to environmental destruction and loss of coal resources and poses a serious threat to human safety and health. In this paper, research related to the initiation, development, and evolution of coalfield fires is reviewed. The existing detection and control techniques of coalfield fires are also reviewed. Traditional firefighting is associated with waste of resources, potential risks of recrudescence, potential safety hazards, extensive and expensive engineering works, and power shortages. Recently,coalfield fires have been recognized as having significant potential for energy conservation and heat energy recovery. Thermoelectric power generation is regarded as a suitable technology for the utilization of heat from coalfield fires. The extraction of heat from coalfield fires can also control coalfield fires and prevent reignition leading to combustion. Technologies for absorbing heat from burning coal and overlying rocks are also analyzed. In addition, the control mode of "three-region linkage" is proposed to improve firefighting efficiency. Integrating heat energy recovery with firefighting is an innovative method to control coalfield fires. 展开更多
关键词 spontaneous coal combustion oxygen supply FIREFIGHTING THERMOELECTRIC THERMOSYPHON three-region linkage
下载PDF
CONDENSING HEAT TRANSFER IN AN ADVANCED TWO-PHASE CLOSED THERMOSYPHON 被引量:1
6
作者 李修伦 闻建平 +1 位作者 单岩昆 黄鸿鼎 《Chinese Journal of Chemical Engineering》 SCIE EI CAS CSCD 1996年第1期88-92,共5页
1 INTRODUCTIONClosed thermosyphon has been developed to enhance heat transfer and recover wasteheat in various process industries [1,2].Stimulated by this success,a new type oftwo-phase closed thermosyphon was designe... 1 INTRODUCTIONClosed thermosyphon has been developed to enhance heat transfer and recover wasteheat in various process industries [1,2].Stimulated by this success,a new type oftwo-phase closed thermosyphon was designed by inserting respectively two inner tubesinto the thermosyphon,one in the boiling section and the other in the condensing sec-tion.The two-phase flow boiling heat transfer coefficient was calculated successfully onthe basis of Chen’s dual-mechanism [3].A boiling heat transfer model for thetwo-phase closed thermosyphon with an inner tube in the boiling section was pro- 展开更多
关键词 TWO-PHASE CLOSED THERMOSYPHON heat TRANSFER NARROW ANNULUS
下载PDF
Centrifuge model test on performance of thermosyphon cooled sandbags stabilizing warm oil pipeline buried in permafrost 被引量:1
7
作者 GuoYu Li HongYuan Jing +2 位作者 Nikolay Volkov Wei Ma PengChao Chen 《Research in Cold and Arid Regions》 CSCD 2021年第3期234-255,共22页
The thaw settlement of pipeline foundation soils in response to the operation of the first China-Russia Crude Oil Pipeline along the eastern flank of the northern Da Xing'anling Mountains in Northeast China was si... The thaw settlement of pipeline foundation soils in response to the operation of the first China-Russia Crude Oil Pipeline along the eastern flank of the northern Da Xing'anling Mountains in Northeast China was simulated in a physical model test(with a similitude ratio of 1/73) in a geotechnical centrifuge. Two pipes of a supported and an unsupported section were evaluated over a testing period for simulating 20 years of actual pipeline operation with seasonal cyclically changing oil and ambient temperatures. The results show that pipe settlement of the supported pipe was 45% of settlement of the unsupported pipe. Settlement for the unsupported section was approximately 35% of the thaw bulb depth below the initial pipe elevation, only 30% of that for the supported pipe due to the influence of the supports. The final thaw bulbs extended approximately 3.6 and 1.6 times of the pipe diameter below the unsupported and supported pipe bottom elevations, respectively. The sandbag supports kept frozen during the test period because of cooling effect of the thermosyphons. The maximum bending stress induced over the 20 m span length from bearing of the full cover over the pipe would be equivalent to40% specified minimum yield strength(SMYS). Potential buckling of the pipe should be considered as the ground thaws.This study also offers important data for calibration and validation of numerical simulation models. 展开更多
关键词 centrifuge test oil pipeline frost heave THERMOSYPHON thaw settlement permafrost engineering
下载PDF
Thermal Modeling of Thermosyphon Integrated Heat Sink for CPU Cooling 被引量:2
8
作者 A. Shanmuga Sundaram Anirudh Bhaskaran 《Journal of Electronics Cooling and Thermal Control》 2011年第2期15-21,共7页
A thermal model has been developed to study the thermal behavior of Thermosyphon integrated Heat Sink during CPU cooling. An Indirect cooling module has been experimentally studied and analyzed under steady state cond... A thermal model has been developed to study the thermal behavior of Thermosyphon integrated Heat Sink during CPU cooling. An Indirect cooling module has been experimentally studied and analyzed under steady state condition for both natural and forced convection. The thermal model is employed to determine the actual heat transfer and the effectiveness of the present model and compared it with the conventional cooling method and found that there is an appreciable improvement in the present model. 展开更多
关键词 THERMOSYPHON HEAT SINK EFFECTIVENESS CONVENTIONAL COOLING Method
下载PDF
Numerical analysis on the thermal regimes of thermosyphon embankment in snowy permafrost area
9
作者 Yan Lu Xin Yi +1 位作者 WenBing Yu WeiBo Liu 《Research in Cold and Arid Regions》 CSCD 2017年第6期668-674,共7页
Snow covers the road embankments in winter in high latitude permafrost zones. The effect of snow cover on embankments was simulated based on field measurements of boundary conditions and initial ground temperature pro... Snow covers the road embankments in winter in high latitude permafrost zones. The effect of snow cover on embankments was simulated based on field measurements of boundary conditions and initial ground temperature profile in Mohe,China. The effect of thermosyphons on the embankment warmed by snow cover was evaluated by numerical simulations as well. The results indicate that the difference of thermal regimes between non-thermosyphon and thermosyphon embankments reaches to 22 m in depth below the ground surface. It is much warmer in the non-thermosyphon embankment body in winter. Affected by the snow cover, heat flux gradually spreads into the deep ground of the subgrade over time. The permafrost table under the slope toe of a thermosyphon embankment is 1.2 m higher than that of a non-thermosyphon embankment in the 20 th year. In addition, the permafrost table at the slope toe of a thermosyphon embankment is 26 cm deeper over 20 years. These results indicate that thermosyphons can greatly weaken the warm effect of snow cover. However,thermosyphons cannot avoid the degradation of permafrost under the scenarios of snow cover. Therefore, composite measures need to be adopted to keep embankment stability in snowy permafrost zones. 展开更多
关键词 SNOW cover PERMAFROST EMBANKMENT thaw SETTLEMENT THERMOSYPHON
下载PDF
Temperature distribution of fluids in a two-section two-phase closed thermosyphon wellbore
10
作者 Zhang Yufeng Zhao Lun +5 位作者 Fan Zifei Wu Xiaodong Fu Libing Xu Bifeng Kong Fanshun Jiang Shengdong 《Petroleum Science》 SCIE CAS CSCD 2014年第2期287-292,共6页
Compared with a conventional single section two-phase closed thermosyphon (TPCT) wellbore, a two-section TPCT wellbore has better heat transfer performance, which may improve the temperature distribution of fluid in... Compared with a conventional single section two-phase closed thermosyphon (TPCT) wellbore, a two-section TPCT wellbore has better heat transfer performance, which may improve the temperature distribution of fluid in wellbores, increase the temperature of fluid in wellheads and even more effectively reduce the failure rate of conventional TPCT wellbores. Heat transfer performance of two-section TPCT wellbores is affected by working medium, combination mode and oil flow rate. Different working media are introduced into the upper and lower TPCTs, which may achieve a better match between the working medium and the temperature field in the wellbores. Interdependence exists between the combination mode and the flow rate of the oil, which affects the heat transfer performance of a two-section TPCT wellbore. The experimental results show that a two-section TPCT wellbore, with equal upper and lower TPCTs respectively filled with Freon and methanol, has the best heat transfer performance when the oil flow rate is 200 L/h. 展开更多
关键词 Two-section two-phase closed thermosyphon temperature distribution combination mode heat transfer performance
下载PDF
A Loop Thermosyphon Type Cooling System for High Heat Flux
11
作者 Jiwon Yeo Seiya Yamashita +1 位作者 Mizuki Hayashida Shigeru Koyama 《Journal of Electronics Cooling and Thermal Control》 2014年第4期128-137,共10页
With rapid development of the semiconductor technology, more efficient cooling systems for electronic devices are needed. In this situation, in the present study, a loop thermosyphon type cooling system, which is comp... With rapid development of the semiconductor technology, more efficient cooling systems for electronic devices are needed. In this situation, in the present study, a loop thermosyphon type cooling system, which is composed mainly of a heating block, an evaporator and an air-cooled condenser, is investigated experimentally in order to evaluate the cooling performance. At first, it is examined that the optimum volume filling rate of this cooling system is approximately 40%. Next, four kinds of working fluids, R1234ze(E), R1234ze(Z), R134a and ethanol, are tested using a blasted heat transfer surface of the evaporator. In cases of R1234ze(E), R1234ze(Z), R134a and ethanol, the effective heat flux, at which the heating block surface temperature reaches 70°C, is 116 W/cm2, 106 W/cm2, 104 W/cm2 and 60 W/cm2, respectively. This result indicates that R1234ze(E) is the most suitable for the present cooling system. The minimum boiling thermal resistance of R1234ze(E) is 0.05 (cm2&middot;K)/W around the effective heat flux of 100 W/cm2. Finally, four kinds of heat transfer surfaces of the evaporator, smooth, blasted, copper-plated and finned surfaces, are tested using R1234ze(E) as working fluid. The boiling thermal resistance of the blasted surface is the smallest among tested heat transfer surfaces up to 116 W/cm2 in effective heat flux. However, it increases drastically due to the appearance of dry-patch if the effective heat flux exceeds 116 W/cm2. On the other hand, in cases of copper-plated and finned surfaces, the dry-patch does not appear up to 150 W/cm2 in effective heat flux, and the boiling thermal resistances of those surfaces keep 0.1 (cm2&middot;K)/W. 展开更多
关键词 COOLING BOILING LOOP THERMOSYPHON Grobal WARMING Potential Thermal RESISTANCE
下载PDF
Effect of Non-Condensable Gas Leakage on Long Term Cooling Performance of Loop Thermosyphon
12
作者 Hiroyuki Toyoda Yoshihiro Kondo 《Journal of Electronics Cooling and Thermal Control》 2013年第4期131-135,共5页
We have developed a loop thermosyphon for cooling electronic devices. The cooling performance of a thermosyphon deteriorates with an increasing amount of non-condensable gas (NCG). Design of a thermosyphon must consid... We have developed a loop thermosyphon for cooling electronic devices. The cooling performance of a thermosyphon deteriorates with an increasing amount of non-condensable gas (NCG). Design of a thermosyphon must consider NCG to provide guaranteed performance for a long time. In this study, the heat transfer performance of a thermosyphon was measured while changing the amount of NCG. The resultant performances were expressed as approximations. These approximations enabled us to predict the total thermal resistance of the thermosyphon by the amount of NCG and input heating. Then, using the known leakage in the thermosyphon and the amount of dissolved NCG in the water, we can predict the amount of NCG and the total thermal resistance of the thermosyphon after ten years. Although there is a slight leakage in the thermosyphon, we are able to design a thermosyphon with a guaranteed level of cooling performance for a long time using the proposed design method. 展开更多
关键词 THERMOSYPHON BOILING CONDENSATION Non-Condensable Gas Heat Transfer PERFORMANCE CPU COOLING
下载PDF
Performance Analysis of Solar Water Heater
13
作者 Shahidul Islam Khan Asif Islam 《Smart Grid and Renewable Energy》 2011年第4期396-398,共3页
Two solar water heaters of 100 liter and 200 liter were installed on the roof-top of electronics laboratory at Old Academic Building (OAB) of Electrical and Electronics Engineering Department of BUET. The data of 12 m... Two solar water heaters of 100 liter and 200 liter were installed on the roof-top of electronics laboratory at Old Academic Building (OAB) of Electrical and Electronics Engineering Department of BUET. The data of 12 months have been collected and analyzed in this paper. It is found that the incoming hot tap water is about 30℃ higher than the room temperature during day time during winter months. This is about 25℃ in afternoon hours. 展开更多
关键词 SOLAR IRRADIATION SOLAR WATER HEATER THERMOSYPHON
下载PDF
Application of a concrete thermal pile in cooling the warming permafrost under climate change
14
作者 Yun-Hu SHANG Fu-Jun NIU +2 位作者 Guo-Yu LI Jian-Hong FANG Ze-Yong GAO 《Advances in Climate Change Research》 SCIE CSCD 2024年第1期170-183,共14页
Permafrost degradation caused by climate warming is posing a serious threat to the stability of cast-in-place pile foundations in warm permafrost regions.Ambient cold energy can be effectively utilized by two-phase cl... Permafrost degradation caused by climate warming is posing a serious threat to the stability of cast-in-place pile foundations in warm permafrost regions.Ambient cold energy can be effectively utilized by two-phase closed thermosyphons(TPCTs)to cool the permafrost.Therefore,we installed TPCTs in a cast-in-place pile foundation to create a unique structure called a thermal pile,which effectively utilizes the TPCTs to regulate ground temperature.And we conducted a case study and numerical simulation to exhibit the cooling performance,and optimize the structure of the thermal pile.The purpose of this study is to promote the application of thermal piles in unstable permafrost regions.Based on the findings,the thermal pile operated for approximately 53%of the entire year and effectively reduced the deep ground temperature at a rate of at least-0.1℃per year.Additionally,it successfully raised the permafrost table that is 0.35 m shallower than the natural ground level.These characteristics prove highly beneficial in mitigating the adverse effects of permafrost degradation and enhancing infrastructure safety.Expanding the length of the condenser section and the diameter of the TPCT in a suitable manner can effectively enhance the cooling capability of the thermal pile and ensure the long-term mechanical stability of the pile foundation even under climate warming. 展开更多
关键词 Heat transfer Cold energy Warm permafrost Two-phase closed thermosyphons Cast-in-place pile foundation
原文传递
Climate warming is likely to weaken the performance of two-phase closed thermosyphon on the Qinghai-Tibet Plateau
15
作者 Guan-Li JIANG Zi-Teng FU +4 位作者 Xin-Yu MEN Hong-Ting ZHAO Si-Ru GAO Yong-Zhi LI Qing-Bai WU 《Advances in Climate Change Research》 SCIE CSCD 2024年第1期90-100,共11页
Over the years,numerous geotechnical approaches have been implemented to mitigate the adverse effects of climate warming on various infrastructures in the permafrost region of the Qinghai-Tibet Plateau(QTP),such as th... Over the years,numerous geotechnical approaches have been implemented to mitigate the adverse effects of climate warming on various infrastructures in the permafrost region of the Qinghai-Tibet Plateau(QTP),such as the Qinghai-Tibet Highway and Railway,and achieved the expected engineering outcomes.However,little attention has been given to whether the performance of these geotechnical approaches has changed during the ongoing process of climate warming.To investigate the performance variation of one of these geotechnical approaches,which is two-phase closed thermosyphon(TPCT),during sustained climate warming,we conducted a statistical analysis of soil temperature monitoring data in 2003-2020 from eight regular embankments and six TPCT embankments in our permafrost monitoring network.The results indicate that TPCT undeniably has a cooling effect on the permafrost beneath embankments,even rapidly eliminated previously formed taliks beneath embankment.However,further analysis reveals that the performance of TPCT has been weakening during sustained climate warming,which has confirmed by the re-forming of the taliks beneath embankment where they had been previously eliminated.Based on the current understanding,we attributed the weakening of thermosyphon performance to a significant reduction in the air temperature freezing index caused by ongoing climate warming.Through this study,we aimed to draw attention to the evolving performance of geotechnical approaches in permafrost regions amid climate warming,prompting necessary engineering innovations to address this situation and ensure the sustainable development of the permafrost region on the QTP. 展开更多
关键词 Two-phase closed thermosyphon Climate warming Supra-permafrost talik Permafrost degradation Qinghai-Tibet Highway
原文传递
Thermal and mechanical characteristics of a thermal pile in permafrost regions 被引量:2
16
作者 Yun-Hu SHANG Fu-Jun NIU +2 位作者 Kun YUAN Tian SUN Li-Bo WU 《Advances in Climate Change Research》 SCIE CSCD 2023年第2期255-266,共12页
Cast-in-place pile foundations are widely used in permafrost regions to support buildings.The stability of cast-in-place pile foundations is highly sensitive to permafrost thermal regime changes.Permafrost degradation... Cast-in-place pile foundations are widely used in permafrost regions to support buildings.The stability of cast-in-place pile foundations is highly sensitive to permafrost thermal regime changes.Permafrost degradation caused by climate change is increasing the disaster risk of castin-place pile foundations.However,proactive cooling methods for cast-in-place pile foundations are seldom reported.The cold energy produced by two-phase closed thermosyphons(TPCTs)can efficiently prevent the permafrost thermal regime from being disturbed by engineering activities and climate change.TPCTs were installed in a concrete pile forming a thermal pile.Then,a model experiment was conducted to explore the thermal regime,influence scope,dissipation process of cold energy,and freezing strength of the thermal pile.The results indicated that the thermal pile may significantly cool the foundation soil.Most of cold energy produced by the thermal pile dissipated during the warm period,and the cooling scope of the thermal pile can cover the area within a 40 cm(twice the pile diameter)radius around the pile.Additionally,the TPCTs can significantly improve freezing strength between the thermal pile and frozen soil.The lesson learned from this study can provide a new approach to control the thermal regime of cast-in-place pile foundation in permafrost,which was of valuable to the construction of pile foundations in cold regions. 展开更多
关键词 Pile foundation Cold energy Two-phase closed thermosyphon Freezing strength Permafrost regions
原文传递
Dynamic simulation and experimental validation of a two-phase closed thermosyphon for geothermal application 被引量:3
17
作者 Johann-Christoph Ebeling Xing Luo +2 位作者 Stephan Kabelac Sebastian Luckmann Horst Kruse 《Propulsion and Power Research》 SCIE 2017年第2期107-116,共10页
The heat transfer perfonmance of a vertical two-phase closed thermosyphon(TPCT)used in a geothermal heat pump was experimentally investigated.The TPCT is a verticalplain steel pipe with inner diameter of 114 mm and bo... The heat transfer perfonmance of a vertical two-phase closed thermosyphon(TPCT)used in a geothermal heat pump was experimentally investigated.The TPCT is a verticalplain steel pipe with inner diameter of 114 mm and bored 368 m deep underground.Carbon dioxide(CO_(2))is used as working fluid.In the TPCT there is no condensation section.CO_(2)is condensed by the evaporator pf the heat pump,flows into the head of the TPCT and nuns down as a falling film along the inner wall of the pipe.For the heat transfer simulation in the TPCT,a quasi-dynamic model in which the mass transfer between the liquid and vapor phases as well as the conduction heat transfer from the surrounding soil towards the pipe is treated dynamically.However the film flow modeling is based on the Nusselt theory of frilm condenssation.The compauison of the experimental data with the numerical simulation is presented and discussed. 展开更多
关键词 Two-phase closed thermosyphon(TPCT) Geothermal thermosy-phon Falling film evaporation Geothermal heat pump Dynamic simulation Experimental validation
原文传递
What is Going on in a Critical Thermosyphon? 被引量:1
18
作者 E. Hahne, U. Gross , G. BarthauInstitut für Thermodynamik und Warmetechnik, Universitat Stuttgart, Pfaffenwaldring 6, D 70550 Stuttgart, Germany, E mail: pm@itw.uni stuttgart.de TU Bergakademie Freiberg, Institut für Technische Th 《Tsinghua Science and Technology》 SCIE EI CAS 2002年第2期109-115,共7页
Critically filled thermosyphons for heat transport differ in size and temperature distribution from critically filled testcells for property research. Consequently, the thermodynamic states within a thermosyphon are... Critically filled thermosyphons for heat transport differ in size and temperature distribution from critically filled testcells for property research. Consequently, the thermodynamic states within a thermosyphon are distributed more heterogeneously. In a glass thermosyphon, flows and phase distributions were observed. A break down of the heat transport mechanism was found as a consequence of flooding the cooling region with liquid. Observed and explained-by use of a density/pressure diagram-were the effects of heating, of pressure and of fluid quantity on the distribution of the phases, the appearance of pulsations and the propagation of a heat pulse near the critical state. 展开更多
关键词 critical state THERMOSYPHON heat pipe opalesence
原文传递
Thermal Hydraulic Stability in a Coaxial Thermosyphon
19
作者 杨健慧 卢文强 +2 位作者 李青 李强 周远 《Tsinghua Science and Technology》 SCIE EI CAS 2005年第3期391-397,共7页
The heat transfer and thermal hydraulic stability in a two-phase thermosyphon with coaxial riser and down-comer has been experimentally investigated and theoretically analyzed to facilitate its application in cold neu... The heat transfer and thermal hydraulic stability in a two-phase thermosyphon with coaxial riser and down-comer has been experimentally investigated and theoretically analyzed to facilitate its application in cold neutron source. The flow in a coaxial thermosyphon was studied experimentally for a variety of heat- ing rates, transfer tube lengths, charge capacities, and area ratios. A numerical analysis of the hydraulic balance between the driving pressure head and the resistance loss has also been performed. The results show that the presented coaxial thermosyphon has dynamic performance advantages relative to natural cir- culation in a boiling water reactor. 展开更多
关键词 coaxial thermosyphon thermal hydraulic stability two-phase flow