Pitting corrosion is harmful during bridge construction,which will lead to uneven roughness of steel surfaces and reduce the thickness of steel.Hence,the effect of pitting corrosion on the mechanical properties of col...Pitting corrosion is harmful during bridge construction,which will lead to uneven roughness of steel surfaces and reduce the thickness of steel.Hence,the effect of pitting corrosion on the mechanical properties of cold-formed thin-walled steel stub columns is studied,and the empirical formulas are established through regression fitting to predict the ultimate load of web and flange under pitting corrosion.In detail,the failure modes and load-displacement curves of specimens with different locations,area ratios,and depths are obtained through a large number of non-linear finite element analysis.As for the specimens with pitting corrosion on the web,all the specimens are subject to local buckling failure,and the failure mode will not change with pitting corrosion,but the failure location will change with pitting corrosion location;the size,location,and area ratio of pitting corrosion have little influence on the ultimate load of cold-formed thin-walled steel short columns,but the loss rate of pitting corrosion section area has a greater impact on the ultimate bearing capacity.As for the specimen with flange pitting corrosion,the location and area ratio of pitting corrosion have less influence on the ultimate load of cold-formed thin-walled steel short columns,and the section area loss rate has greater influence on the ultimate bearing capacity;the impact of web pitting corrosion on the ultimate load is greater than that of flange pitting corrosion under the same condition of pitting corrosion section area.The prediction formulas of limit load which are suitable for pitting corrosion of web and flange are established,which can provide a reference for performance evaluation of corroded cold-formed thin-walled steel.展开更多
The steel-bamboo composite structure is a newly developed structure,combining phyllostachys pubescens(also called Moso bamboo)plywood and cold-formed thin-walled steel with structural adhesive.The reliability of steel...The steel-bamboo composite structure is a newly developed structure,combining phyllostachys pubescens(also called Moso bamboo)plywood and cold-formed thin-walled steel with structural adhesive.The reliability of steelbamboo interface is the premise of composite effect.13 specimens were prepared to investigate the failure modes and mechanism of the steel-bamboo interface on the basis of push-out test,and the strain difference analysis method was proposed to study the distribution of shear stress.The results show that the main failure modes of steel-bamboo interface are adhesion failure and splitting of bamboo plywood.The shear stress is not evenly distributed along the longitudinal direction of the interface,showing a shape of“larger at two ends and smaller in the middle”.The lower end of the interface is the initial location of the interface failure and the shear stress concentration degree is positively correlated with the thickness of the externally bonded bamboo plate.The shear resistance of steel-bamboo interface can be enhanced by improving the adhesion between steel and structural adhesive and ameliorating the quality of bamboo products.展开更多
In the past, blast-resistant designs for structures were often constructed with massive type structural systems, which relied more on brute strength than on finesse to achieve the required blast resistance. However, s...In the past, blast-resistant designs for structures were often constructed with massive type structural systems, which relied more on brute strength than on finesse to achieve the required blast resistance. However, structures composed of COLD-FORMED steel components, such as sheet metal and metal studs, have shown great promise in providing blast resistance with the added benefits of low cost and ease of construction. Some examples of using such structures to provide containment for package handling facilities (PHF) are described in the paper for situations where blast containment is needed, such as a potential package bomb being discovered during the package vetting process. Results from tests and analytic data are used to illustrate aspects of design peculiar to such types of applications. Designs for specific capacities of PHF are described.展开更多
A good understanding of the effects of galvanizing on the short-and long-term behaviours of steel components is essential for structural design.This review paper is motivated by a series of recent reports on cracking ...A good understanding of the effects of galvanizing on the short-and long-term behaviours of steel components is essential for structural design.This review paper is motivated by a series of recent reports on cracking in galvanized cold-formed tubular steel structures and the limitations of current steel product standards and steel design specifications in this field.The steel-related and galvanizing-related factors,different pre-galvanizing countermeasures for brittle cracking and the available technical documents are summarized.An extensive bibliography is provided as a basis for future research and development in this field.展开更多
This paper presents a literature review focused on the material performance of cold-formed, carbon steel, hollow structural sections under impulsive (highly dynamic) loading. Impulsive loading, represented by impact...This paper presents a literature review focused on the material performance of cold-formed, carbon steel, hollow structural sections under impulsive (highly dynamic) loading. Impulsive loading, represented by impact and blast, is characterized by a very rapid, time-dependent loading regime in the affected members and materials. Thus, the effect of high-strain-rate loading is initially reviewed. Next the material toughness, an important energy-absorption property and one measure of a material's ability to arrest fracture, is considered by means of studying the Charpy V-notch behavior. The response of hollow sections under axial and lateral impact loading is then reviewed. Studies of blast on hollow sections, most of which fall under the categories of contact/near-field loading or far-field loading are presented. Under large-scale field blast experiments, cold-formed hollow sections have shown excellent behavior. Software for modeling blast loading and structural response, the latter including single degree of freedom analysis and explicit finite element analysis, is described and discussed.展开更多
基金funded by the‘Research Project of the Sucheng to Sihong Section of the Yanluo Expressway-Measurement Technology and Application of Bridge Quality Project Based on UAV Binocular Imaging(No.00-00-JSFW-20230203-029)’,received by H.Z.Wang.
文摘Pitting corrosion is harmful during bridge construction,which will lead to uneven roughness of steel surfaces and reduce the thickness of steel.Hence,the effect of pitting corrosion on the mechanical properties of cold-formed thin-walled steel stub columns is studied,and the empirical formulas are established through regression fitting to predict the ultimate load of web and flange under pitting corrosion.In detail,the failure modes and load-displacement curves of specimens with different locations,area ratios,and depths are obtained through a large number of non-linear finite element analysis.As for the specimens with pitting corrosion on the web,all the specimens are subject to local buckling failure,and the failure mode will not change with pitting corrosion,but the failure location will change with pitting corrosion location;the size,location,and area ratio of pitting corrosion have little influence on the ultimate load of cold-formed thin-walled steel short columns,but the loss rate of pitting corrosion section area has a greater impact on the ultimate bearing capacity.As for the specimen with flange pitting corrosion,the location and area ratio of pitting corrosion have less influence on the ultimate load of cold-formed thin-walled steel short columns,and the section area loss rate has greater influence on the ultimate bearing capacity;the impact of web pitting corrosion on the ultimate load is greater than that of flange pitting corrosion under the same condition of pitting corrosion section area.The prediction formulas of limit load which are suitable for pitting corrosion of web and flange are established,which can provide a reference for performance evaluation of corroded cold-formed thin-walled steel.
基金supported by National Key R&D Program of China[grant number 2017YFC0703502]the National Natural Science Foundation of China(NSFC)[grant numbers 51978345,51678310 and 51708304]K.C.Wong Magna Fund at the Ningbo University.
文摘The steel-bamboo composite structure is a newly developed structure,combining phyllostachys pubescens(also called Moso bamboo)plywood and cold-formed thin-walled steel with structural adhesive.The reliability of steelbamboo interface is the premise of composite effect.13 specimens were prepared to investigate the failure modes and mechanism of the steel-bamboo interface on the basis of push-out test,and the strain difference analysis method was proposed to study the distribution of shear stress.The results show that the main failure modes of steel-bamboo interface are adhesion failure and splitting of bamboo plywood.The shear stress is not evenly distributed along the longitudinal direction of the interface,showing a shape of“larger at two ends and smaller in the middle”.The lower end of the interface is the initial location of the interface failure and the shear stress concentration degree is positively correlated with the thickness of the externally bonded bamboo plate.The shear resistance of steel-bamboo interface can be enhanced by improving the adhesion between steel and structural adhesive and ameliorating the quality of bamboo products.
文摘In the past, blast-resistant designs for structures were often constructed with massive type structural systems, which relied more on brute strength than on finesse to achieve the required blast resistance. However, structures composed of COLD-FORMED steel components, such as sheet metal and metal studs, have shown great promise in providing blast resistance with the added benefits of low cost and ease of construction. Some examples of using such structures to provide containment for package handling facilities (PHF) are described in the paper for situations where blast containment is needed, such as a potential package bomb being discovered during the package vetting process. Results from tests and analytic data are used to illustrate aspects of design peculiar to such types of applications. Designs for specific capacities of PHF are described.
文摘A good understanding of the effects of galvanizing on the short-and long-term behaviours of steel components is essential for structural design.This review paper is motivated by a series of recent reports on cracking in galvanized cold-formed tubular steel structures and the limitations of current steel product standards and steel design specifications in this field.The steel-related and galvanizing-related factors,different pre-galvanizing countermeasures for brittle cracking and the available technical documents are summarized.An extensive bibliography is provided as a basis for future research and development in this field.
文摘This paper presents a literature review focused on the material performance of cold-formed, carbon steel, hollow structural sections under impulsive (highly dynamic) loading. Impulsive loading, represented by impact and blast, is characterized by a very rapid, time-dependent loading regime in the affected members and materials. Thus, the effect of high-strain-rate loading is initially reviewed. Next the material toughness, an important energy-absorption property and one measure of a material's ability to arrest fracture, is considered by means of studying the Charpy V-notch behavior. The response of hollow sections under axial and lateral impact loading is then reviewed. Studies of blast on hollow sections, most of which fall under the categories of contact/near-field loading or far-field loading are presented. Under large-scale field blast experiments, cold-formed hollow sections have shown excellent behavior. Software for modeling blast loading and structural response, the latter including single degree of freedom analysis and explicit finite element analysis, is described and discussed.