Several media report highlight on that the pharmaceutical companies require ultra-low temperatures -80<span style="white-space:nowrap;">°</span>C to transport and store its COVID-19 vaccines...Several media report highlight on that the pharmaceutical companies require ultra-low temperatures -80<span style="white-space:nowrap;">°</span>C to transport and store its COVID-19 vaccines. This research presents the thermodynamic analysis on cascade refrigeration system (CRS) with several refrigerant pairs which are R32/R170, R123/R170, R134a/R170, R404A/R170, R407c/R170, R410/R170, and the hydrocarbon (HC) refrigerant pair Propane/Ethane, namely R290/R170. Besides, the results of R22/R170 pair, which is not recommended to be used due to phase out of R22 as per Montréal Protocol, are included as base case to compare the novel hydrocarbon pairs in CRS and the old trend of refrigerant pairs. Thermodynamic properties of all these pairs were investigated and compared under different intermediate temperature used in CRS heat exchanger, which thermally connected both the Low and High temperature cycles (LTC) and (HTC). By applying the first law of thermodynamics, the coefficients of performance (COPs) and the specific power consumptions (SPC) in kW/TR are presented and compared. In addition, by applying the second law of thermodynamics the exergetic efficiencies were estimated. The results reveal the promising opportunity of using the HC pair (R290/R170). The minimum SPC in kW/TR is recorded for the pair R123/R170. One the other hand, the highest exegetic efficiency values are observed to be 40%, 38%, and 35% for the pairs R123/R170, R290/R170, and R134/R170, respectively. This research concludes that the HC pair (R290/R170) is highly recommended for CRS applications either to transport the COVID-19 or store it in cold storage rooms in hospitals and clinics. All precautionary measures should be carefully applied in design and operation of HC pair (R290/R170) due to its flammability hazard.展开更多
Faced with economic recession,firms struggle to find ways to stay competitive and maintain market share.Effective coordination of the supply chain can solve this problem,but this may fail if existing capital constrain...Faced with economic recession,firms struggle to find ways to stay competitive and maintain market share.Effective coordination of the supply chain can solve this problem,but this may fail if existing capital constraints and financial flows are ignored.This study addresses the challenge by exploiting coordination through joint decision-making on the physical and financial flows of a capital-constrained supply chain.We also consider the capital-constrained member’s financing limitations that lead to lost sales.Two scenarios based on non-coordinated and coordinated structures are modeled in the form of bi-objective optimization problems that simultaneously optimize system costs and service levels.The models are solved using the-constraint method.The results indicate that the non-coordinated model cannot satisfy more than about 50%of the demand due to capital shortage and financing limitations,while the coordinated model can satisfy all of the demand via internal financing.Furthermore,the proposed coordination scheme leads to cost reduction for the members and the total system.To motivate all members to accept the proposed coordination scheme,a cost-sharing mechanism is applied to the coordination procedure.Finally,a sensitivity analysis concerning financial parameters is provided for validating the coordination model.展开更多
文摘Several media report highlight on that the pharmaceutical companies require ultra-low temperatures -80<span style="white-space:nowrap;">°</span>C to transport and store its COVID-19 vaccines. This research presents the thermodynamic analysis on cascade refrigeration system (CRS) with several refrigerant pairs which are R32/R170, R123/R170, R134a/R170, R404A/R170, R407c/R170, R410/R170, and the hydrocarbon (HC) refrigerant pair Propane/Ethane, namely R290/R170. Besides, the results of R22/R170 pair, which is not recommended to be used due to phase out of R22 as per Montréal Protocol, are included as base case to compare the novel hydrocarbon pairs in CRS and the old trend of refrigerant pairs. Thermodynamic properties of all these pairs were investigated and compared under different intermediate temperature used in CRS heat exchanger, which thermally connected both the Low and High temperature cycles (LTC) and (HTC). By applying the first law of thermodynamics, the coefficients of performance (COPs) and the specific power consumptions (SPC) in kW/TR are presented and compared. In addition, by applying the second law of thermodynamics the exergetic efficiencies were estimated. The results reveal the promising opportunity of using the HC pair (R290/R170). The minimum SPC in kW/TR is recorded for the pair R123/R170. One the other hand, the highest exegetic efficiency values are observed to be 40%, 38%, and 35% for the pairs R123/R170, R290/R170, and R134/R170, respectively. This research concludes that the HC pair (R290/R170) is highly recommended for CRS applications either to transport the COVID-19 or store it in cold storage rooms in hospitals and clinics. All precautionary measures should be carefully applied in design and operation of HC pair (R290/R170) due to its flammability hazard.
文摘Faced with economic recession,firms struggle to find ways to stay competitive and maintain market share.Effective coordination of the supply chain can solve this problem,but this may fail if existing capital constraints and financial flows are ignored.This study addresses the challenge by exploiting coordination through joint decision-making on the physical and financial flows of a capital-constrained supply chain.We also consider the capital-constrained member’s financing limitations that lead to lost sales.Two scenarios based on non-coordinated and coordinated structures are modeled in the form of bi-objective optimization problems that simultaneously optimize system costs and service levels.The models are solved using the-constraint method.The results indicate that the non-coordinated model cannot satisfy more than about 50%of the demand due to capital shortage and financing limitations,while the coordinated model can satisfy all of the demand via internal financing.Furthermore,the proposed coordination scheme leads to cost reduction for the members and the total system.To motivate all members to accept the proposed coordination scheme,a cost-sharing mechanism is applied to the coordination procedure.Finally,a sensitivity analysis concerning financial parameters is provided for validating the coordination model.