期刊文献+
共找到1,704篇文章
< 1 2 86 >
每页显示 20 50 100
Three-dimensional computed tomography reconstruction diagnosed digestive tract perforation and acute peritonitis caused by Monopterus albus:A case report
1
作者 Jin-Han Yang Jin-Ying Lan +2 位作者 An-Yuan Lin Wei-Biao Huang Jin-Yuan Liao 《World Journal of Gastrointestinal Surgery》 SCIE 2023年第10期2351-2356,共6页
BACKGROUND Few reports have described living foreign bodies in the human body.The current manuscript demonstrates that computed tomography(CT)is an effective tool for accurate preoperative evaluation of living foreign... BACKGROUND Few reports have described living foreign bodies in the human body.The current manuscript demonstrates that computed tomography(CT)is an effective tool for accurate preoperative evaluation of living foreign bodies in clinic.The threedimensional(3D)reconstruction technology could clearly display anatomical structures,lesions and adjacent organs,improving diagnostic accuracy and guiding the surgical decision-making process.CASE SUMMARY Herein we describe a 68-year-old man diagnosed with digestive tract perforation and acute peritonitis caused by a foreign body of Monopterus albus.The patient pre-sented to the emergency department with complaints of dull abdominal pain,profuse sweating and a pale complexion during work.A Monopterus albus had entered the patient’s body through the anus two hours ago.During hospitalization,the 3D reconstruction technology revealed a perforation of the middle rectum complicated with acute peritonitis and showed a clear and complete Monopterus albus bone morphology in the abdominal and pelvic cavities,with the Monopterus albus biting the mesentery.Laparoscopic examination detected a large(diameter of about 1.5 cm)perforation in the mid-rectum.It could be seen that a Monopterus albus had completely entered the abdominal cavity and had tightly bitten the mesentery of the small intestine.During the operation,the dead Monopterus albus was taken out.CONCLUSION The current manuscript demonstrates that CT is an effective tool for accurate preoperative evaluation of living foreign bodies in clinic. 展开更多
关键词 Digestive tract perforation Acute peritonitis Monopterus albus three-dimensional computed tomography reconstruction Case report
下载PDF
Computed tomography three-dimensional reconstruction in the diagnosis of bleeding small intestinal polyps:A case report
2
作者 Shu-Hui Zhang Ming-Wei Fan +2 位作者 Yan Chen Ying-Bin Hu Cheng-Xia Liu 《World Journal of Clinical Cases》 SCIE 2024年第16期2831-2836,共6页
BACKGROUND Computed tomography(CT)small bowel three-dimensional(3D)reconstruction is a powerful tool for the diagnosis of small bowel disease and can clearly show the intestinal lumen and wall as well as the outside s... BACKGROUND Computed tomography(CT)small bowel three-dimensional(3D)reconstruction is a powerful tool for the diagnosis of small bowel disease and can clearly show the intestinal lumen and wall as well as the outside structure of the wall.The horizontal axis position can show the best adjacent intestinal tube and the lesion between the intestinal tubes,while the coronal position can show the overall view of the small bowel.The ileal end of the localization of the display of excellent,and easy to quantitative measurement of the affected intestinal segments,the sagittal position for the rectum and the pre-sacral lesions show the best,for the discovery of fistulae is also helpful.Sagittal view can show rectal and presacral lesions and is useful for fistula detection.It is suitable for the assessment of inflammatory bowel disease,such as assessment of disease severity and diagnosis and differential diagnosis of the small bowel and mesenteric space-occupying lesions as well as the judgment of small bowel obstruction points.CASE SUMMARY Bleeding caused by small intestinal polyps is often difficult to diagnose in clinical practice.This study reports a 29-year-old male patient who was admitted to the hospital with black stool and abdominal pain for 3 months.Using the combination of CT-3D reconstruction and capsule endoscopy,the condition was diagnosed correctly,and the polyps were removed using single-balloon enteroscopyendoscopic retrograde cholangiopancreatography without postoperative complications.CONCLUSION The role of CT-3D in gastrointestinal diseases was confirmed.CT-3D can assist in the diagnosis and treatment of gastrointestinal diseases in combination with capsule endoscopy and small intestinal microscopy. 展开更多
关键词 computed tomography three-dimensional reconstruction Capsule endoscopy Single-balloon enteroscopy Gastrointestinal bleeding Case report
下载PDF
Evaluating the use of three-dimensional reconstruction visualization technology for precise laparoscopic resection in gastroesophageal junction cancer
3
作者 Dan Guo Xiao-Yan Zhu +2 位作者 Shuai Han Yu-Shu Liu Da-Peng Cui 《World Journal of Gastrointestinal Surgery》 SCIE 2024年第5期1311-1319,共9页
BACKGROUND Laparoscopic gastrectomy for esophagogastric junction(EGJ)carcinoma enables the removal of the carcinoma at the junction between the stomach and esophagus while preserving the gastric function,thereby provi... BACKGROUND Laparoscopic gastrectomy for esophagogastric junction(EGJ)carcinoma enables the removal of the carcinoma at the junction between the stomach and esophagus while preserving the gastric function,thereby providing patients with better treatment outcomes and quality of life.Nonetheless,this surgical technique also presents some challenges and limitations.Therefore,three-dimensional reconstruction visualization technology(3D RVT)has been introduced into the procedure,providing doctors with more comprehensive and intuitive anatomical information that helps with surgical planning,navigation,and outcome evaluation.AIM To discuss the application and advantages of 3D RVT in precise laparoscopic resection of EGJ carcinomas.METHODS Data were obtained from the electronic or paper-based medical records at The First Affiliated Hospital of Hebei North University from January 2020 to June 2022.A total of 120 patients diagnosed with EGJ carcinoma were included in the study.Of these,68 underwent laparoscopic resection after computed tomography(CT)-enhanced scanning and were categorized into the 2D group,whereas 52 underwent laparoscopic resection after CT-enhanced scanning and 3D RVT and were categorized into the 3D group.This study had two outcome measures:the deviation between tumor-related factors(such as maximum tumor diameter and infiltration length)in 3D RVT and clinical reality,and surgical outcome indicators(such as operative time,intraoperative blood loss,number of lymph node dissections,R0 resection rate,postoperative hospital stay,postoperative gas discharge time,drainage tube removal time,and related complications)between the 2D and 3D groups.RESULTS Among patients included in the 3D group,27 had a maximum tumor diameter of less than 3 cm,whereas 25 had a diameter of 3 cm or more.In actual surgical observations,24 had a diameter of less than 3 cm,whereas 28 had a diameter of 3 cm or more.The findings were consistent between the two methods(χ^(2)=0.346,P=0.556),with a kappa consistency coefficient of 0.808.With respect to infiltration length,in the 3D group,23 patients had a length of less than 5 cm,whereas 29 had a length of 5 cm or more.In actual surgical observations,20 cases had a length of less than 5 cm,whereas 32 had a length of 5 cm or more.The findings were consistent between the two methods(χ^(2)=0.357,P=0.550),with a kappa consistency coefficient of 0.486.Pearson correlation analysis showed that the maximum tumor diameter and infiltration length measured using 3D RVT were positively correlated with clinical observations during surgery(r=0.814 and 0.490,both P<0.05).The 3D group had a shorter operative time(157.02±8.38 vs 183.16±23.87),less intraoperative blood loss(83.65±14.22 vs 110.94±22.05),and higher number of lymph node dissections(28.98±2.82 vs 23.56±2.77)and R0 resection rate(80.77%vs 61.64%)than the 2D group.Furthermore,the 3D group had shorter hospital stay[8(8,9)vs 13(14,16)],time to gas passage[3(3,4)vs 4(5,5)],and drainage tube removal time[4(4,5)vs 6(6,7)]than the 2D group.The complication rate was lower in the 3D group(11.54%)than in the 2D group(26.47%)(χ^(2)=4.106,P<0.05).CONCLUSION Using 3D RVT,doctors can gain a more comprehensive and intuitive understanding of the anatomy and related lesions of EGJ carcinomas,thus enabling more accurate surgical planning. 展开更多
关键词 Gastroesophageal junction cancer ENDOSCOPY Tumor resection three-dimensional reconstruction visualization Two-dimensional imaging computed tomography
下载PDF
Artificial Intelligence-Based Image Reconstruction for Computed Tomography: A Survey
4
作者 Quan Yan Yunfan Ye +3 位作者 Jing Xia Zhiping Cai Zhilin Wang Qiang Ni 《Intelligent Automation & Soft Computing》 SCIE 2023年第6期2545-2558,共14页
Computed tomography has made significant advances since its intro-duction in the early 1970s,where researchers have mainly focused on the quality of image reconstruction in the early stage.However,radiation exposure p... Computed tomography has made significant advances since its intro-duction in the early 1970s,where researchers have mainly focused on the quality of image reconstruction in the early stage.However,radiation exposure poses a health risk,prompting the demand of the lowest possible dose when carrying out CT examinations.To acquire high-quality reconstruction images with low dose radiation,CT reconstruction techniques have evolved from conventional reconstruction such as analytical and iterative reconstruction,to reconstruction methods based on artificial intelligence(AI).All these efforts are devoted to con-structing high-quality images using only low doses with fast reconstruction speed.In particular,conventional reconstruction methods usually optimize one aspect,while AI-based reconstruction has finally managed to attain all goals in one shot.However,there are limitations such as the requirements on large datasets,unstable performance,and weak generalizability in AI-based reconstruction methods.This work presents the review and discussion on the classification,the commercial use,the advantages,and the limitations of AI-based image reconstruction methods in CT. 展开更多
关键词 computed tomography image reconstruction artificial intelligence
下载PDF
Fast parallel algorithm for three-dimensional distance-driven model in iterative computed tomography reconstruction
5
作者 陈建林 李磊 +5 位作者 王林元 蔡爱龙 席晓琦 张瀚铭 李建新 闫镔 《Chinese Physics B》 SCIE EI CAS CSCD 2015年第2期513-520,共8页
The projection matrix model is used to describe the physical relationship between reconstructed object and projection.Such a model has a strong influence on projection and backprojection,two vital operations in iterat... The projection matrix model is used to describe the physical relationship between reconstructed object and projection.Such a model has a strong influence on projection and backprojection,two vital operations in iterative computed tomographic reconstruction.The distance-driven model(DDM) is a state-of-the-art technology that simulates forward and back projections.This model has a low computational complexity and a relatively high spatial resolution;however,it includes only a few methods in a parallel operation with a matched model scheme.This study introduces a fast and parallelizable algorithm to improve the traditional DDM for computing the parallel projection and backprojection operations.Our proposed model has been implemented on a GPU(graphic processing unit) platform and has achieved satisfactory computational efficiency with no approximation.The runtime for the projection and backprojection operations with our model is approximately 4.5 s and 10.5 s per loop,respectively,with an image size of 256×256×256 and 360 projections with a size of 512×512.We compare several general algorithms that have been proposed for maximizing GPU efficiency by using the unmatched projection/backprojection models in a parallel computation.The imaging resolution is not sacrificed and remains accurate during computed tomographic reconstruction. 展开更多
关键词 computed tomography iterative reconstruction parallelizable algorithm distance-driven model
下载PDF
Value of liver computed tomography with iodixanol 270, 80 kVp and iterative reconstruction 被引量:5
6
作者 Diomidis Botsikas Isabelle Barnaure +3 位作者 Sylvain Terraz Christoph D Becker Anastasia Kalovidouri Xavier Montet 《World Journal of Radiology》 CAS 2016年第7期693-699,共7页
AIM: To evaluate the image quality of hepatic multidetector computed tomography(MDCT) with dynamic contrast enhancement. METHODS: It uses iodixanol 270 mg/m L(Visipaque 270) and 80 kVp acquisitions reconstructed with ... AIM: To evaluate the image quality of hepatic multidetector computed tomography(MDCT) with dynamic contrast enhancement. METHODS: It uses iodixanol 270 mg/m L(Visipaque 270) and 80 kVp acquisitions reconstructed with sinogram affirmed iterative reconstruction(SAFIRE?) in comparison with a standard MDCT protocol. Fiftythree consecutive patients with known or suspected hepatocellular carcinoma underwent 55 CT examinations, with two different four-phase CT protocols. The first group of 30 patients underwent a standard 120 kVp acquisition after injection of Iohexol 350 mg/m L(Accupaque 350~?) and reconstructed with filtered back projection. The second group of 25 patients underwent a dual-energy CT at 80-140 kVp with iodixanol 270. The 80 kVp component of the second group was reconstructed iteratively(SAFIRE?-Siemens). All hyperdense and hypodense hepatic lesions ≥ 5 mm were identified with both protocols. Aorta and portal vessels/liver parenchyma contrast to noise ratio(CNR) in arterial phase, hypervascular lesion/liver parenchyma CNR in arterial phase, hypodense lesion/liver parenchyma CNR in portal and late phase were calculated in both groups.RESULTS: Aorta/liver and focal lesions altogether/liver CNR were higher for the second protocol(P = 0.0078 and 0.0346). Hypervascular lesions/liver CNR was not statistically different(P = 0.86). Hypodense lesion/liver CNR in the portal phase was significantly higher for the second group(P = 0.0107). Hypodense lesion/liver CNR in the late phase was the same for both groups(P = 0.9926).CONCLUSION: MDCT imaging with 80 kVp with iterative reconstruction and iodixanol 270 yields equal or even better image quality. 展开更多
关键词 Multiphasic dynamic LIVER computed tomography Low-kVp computed tomography Iso-osmolar IODINE CONTRAST AGENT Low IODINE concentration CONTRAST AGENT Iterative reconstruction
下载PDF
Non-enhanced Low-tube-voltage High-pitch Dual-source Computed Tomography with Sinogram Affirmed Iterative Reconstruction Algorithm of the Abdomen and Pelvis 被引量:3
7
作者 Hao Sun Hua-dan Xue +5 位作者 Zheng-yu Jin Xuan Wang Yu Chen Yong-lan He Da-ming Zhang Liang Zhu 《Chinese Medical Sciences Journal》 CAS CSCD 2014年第4期214-220,共7页
Objective To investigate the image quality, radiation dose and diagnostic value of the low-tube-voltage high-pitch dual-source computed tomography(DSCT) with sinogram affirmed iterative reconstruction(SAFIRE) for non-... Objective To investigate the image quality, radiation dose and diagnostic value of the low-tube-voltage high-pitch dual-source computed tomography(DSCT) with sinogram affirmed iterative reconstruction(SAFIRE) for non-enhanced abdominal and pelvic scans. Methods This institutional review board-approved prospective study included 64 patients who gave written informed consent for additional abdominal and pelvic scan with DSCT in the period from November to December 2012. The patients underwent standard non-enhanced CT scans(protocol 1) [tube voltage of 120 k Vp/pitch of 0.9/filtered back-projection(FBP) reconstruction] followed by high-pitch non-enhanced CT scans(protocol 2)(100 k Vp/3.0/SAFIRE). The total scan time, mean CT number, signal-to-noise ratio(SNR), image quality, lesion detectability and radiation dose were compared between the two protocols. Results The total scan time of protocol 2 was significantly shorter than that of protocol 1(1.4±0.1 seconds vs. 7.6±0.6 seconds, P<0.001). There was no significant difference between protocol 1 and protocol 2 in mean CT number of all organs(liver, 55.4±6.3 HU vs. 56.1±6.8 HU, P=0.214; pancreas, 43.6±5.9 HU vs. 43.7±5.8 HU, P=0.785; spleen, 47.9±3.9 HU vs. 49.4±4.3 HU, P=0.128; kidney, 32.2±2.3 HU vs. 33.1±2.3 HU, P=0.367; abdominal aorta, 44.8±5.6 HU vs. 45.0±5.5 HU, P=0.499; psoas muscle, 50.7±4.1 HU vs. 50.3±4.5 HU, P=0.279). SNR on images of protocol 2 was higher than that of protocol 1(liver, 5.0±1.2 vs. 4.5±1.1, P<0.001; pancreas, 4.0±1.0 vs. 3.6±0.8, P<0.001; spleen, 4.7±1.0 vs. 4.1±0.9, P<0.001; kidney, 3.1±0.6 vs. 2.8±0.6, P<0.001; abdominal aorta, 4.1±1.0 vs. 3.8±1.0, P<0.001; psoas muscle, 4.5±1.1 vs. 4.3±1.2, P=0.012). The overall image noise of protocol 2 was lower than that of protocol1(9.8±3.1 HU vs. 11.1±3.0 HU, P<0.001). Image quality of protocol 2 was good but lower than that of protocol 1(4.1±0.7 vs. 4.6±0.5, P<0.001). Protocol 2 perceived 229 of 234 lesions(97.9%) that were detected in protocol 1 in the abdomen and pelvis. Radiation dose of protocol 2 was lower than that of protocol 1(4.4±0.4 m Sv vs. 7.3±2.4 m Sv, P<0.001) and the mean dose reduction was 41.4%. Conclusion The high-pitch DSCT with SAFIRE can shorten scan time and reduce radiation dose while preserving image quality in non-enhanced abdominal and pelvic scans. 展开更多
关键词 high PITCH dual-source computed tomography iterative reconstruction imagequality radiation DOSE
下载PDF
An algorithm for computed tomography image reconstruction from limited-view projections 被引量:5
8
作者 王林元 李磊 +3 位作者 闫镔 江成顺 王浩宇 包尚联 《Chinese Physics B》 SCIE EI CAS CSCD 2010年第8期642-647,共6页
With the development of the compressive sensing theory, the image reconstruction from the projections viewed in limited angles is one of the hot problems in the research of computed tomography technology. This paper d... With the development of the compressive sensing theory, the image reconstruction from the projections viewed in limited angles is one of the hot problems in the research of computed tomography technology. This paper develops an iterative algorithm for image reconstruction, which can fit the most cases. This method gives an image reconstruction flow with the difference image vector, which is based on the concept that the difference image vector between the reconstructed and the reference image is sparse enough. Then the l1-norm minimization method is used to reconstruct the difference vector to recover the image for flat subjects in limited angles. The algorithm has been tested with a thin planar phantom and a real object in limited-view projection data. Moreover, all the studies showed the satisfactory results in accuracy at a rather high reconstruction speed. 展开更多
关键词 limited-view problem computed tomography image reconstruction algorithms reconstruction-reference difference algorithm adaptive steepest descent-projection onto convex sets algorithm
下载PDF
Effects of dry-wet cycles on three-dimensional pore structure and permeability characteristics of granite residual soil using X-ray micro computed tomography 被引量:13
9
作者 Ran An Lingwei Kong +1 位作者 Xianwei Zhang Chengsheng Li 《Journal of Rock Mechanics and Geotechnical Engineering》 SCIE CSCD 2022年第3期851-860,共10页
Due to seasonal climate alterations,the microstructure and permeability of granite residual soil are easily affected by multiple dry-wet cycles.The X-ray micro computed tomography(micro-CT)acted as a nondestructive to... Due to seasonal climate alterations,the microstructure and permeability of granite residual soil are easily affected by multiple dry-wet cycles.The X-ray micro computed tomography(micro-CT)acted as a nondestructive tool for characterizing the microstructure of soil samples exposed to a range of damage levels induced by dry-wet cycles.Subsequently,the variations of pore distribution and permeability due to drywet cycling effects were revealed based on three-dimensional(3D)pore distribution analysis and seepage simulations.According to the results,granite residual soils could be separated into four different components,namely,pores,clay,quartz,and hematite,from micro-CT images.The reconstructed 3D pore models dynamically demonstrated the expanding and connecting patterns of pore structures during drywet cycles.The values of porosity and connectivity are positively correlated with the number of dry-wet cycles,which were expressed by exponential and linear functions,respectively.The pore volume probability distribution curves of granite residual soil coincide with the χ^(2)distribution curve,which verifies the effectiveness of the assumption of χ^(2)distribution probability.The pore volume distribution curves suggest that the pores in soils were divided into four types based on their volumes,i.e.micropores,mesopores,macropores,and cracks.From a quantitative and visual perspective,considerable small pores are gradually transformed into cracks with a large volume and a high connectivity.Under the action of dry-wet cycles,the number of seepage flow streamlines which contribute to water permeation in seepage simulation increases distinctly,as well as the permeability and hydraulic conductivity.The calculated hydraulic conductivity is comparable with measured ones with an acceptable error margin in general,verifying the accuracy of seepage simulations based on micro-CT results. 展开更多
关键词 Granite residual soil Dry-wet cycle X-ray micro computed tomography(micro-CT) three-dimensional(3D)pore distribution Seepage simulations PERMEABILITY
下载PDF
Preoperative diagnosis and operative effect of intracranial aneurysm with three-dimensional computed tomography angiography 被引量:11
10
作者 Xuxin Zhang Junhong Guan Duo Chen Yongjie Yang Xiangtai Wei 《Neural Regeneration Research》 SCIE CAS CSCD 2006年第4期358-360,共3页
BACKGROUND : Digital subtraction angiography (DSA) is always regarded as the golden standard for diagnosis of intracranial aneurysm; however, the procedure is complex, traumatic, expensive and easy to induce vascul... BACKGROUND : Digital subtraction angiography (DSA) is always regarded as the golden standard for diagnosis of intracranial aneurysm; however, the procedure is complex, traumatic, expensive and easy to induce vascular complication. Three-dimensional computed tomography angiography (3D-CTA) can make up deficiencies of DSA; therefore, it is used in clinical therapy wider and wider. OBJECTIVE : To evaluate the clinical effect of 3D-CTA on disruption and hemorrhage of intracranial aneurysm pre- and post-operation and compare with the effect of DSA. DESIGN : Auto-control contrast observation SETTING : Department of Neurosurgery, Shengjing Hospital of China Medical University PARTICIPANTS : A number of 106 patients with disruption and hemorrhage of intracranial aneurysm were selected from the Department of Neurosurgery, Shengjing Hospital of China Medical University from January 2003 to April 2006. All patients were diagnosed with cranial operation and consent. There were 47 males and 59 females aged from 3-76 years with the mean age of (47±13) years. Among them, 82 patients had extensive subarachnoid hemorrhage (SAH), 7 had hemorrhage at longitudinal fissure, and 17 had hemorrhage at ambiens cistema and lateral fissure. Moreover, intraventricular hematocele was accompanied on 13 patients and hematom on 9 patients. METHODS: (1) 3D-CTA examination: Siemens SOMATOM Sensation 64 CT was used in this study. The thickness was 1 mm and interval of reconstruction was 0.8 mm. Localizing section was plainly scanned as the standard of canthus line. Scan ranged from 30 mm below sella to 50 mm above sella. Non-ion contrast medium of Omnipaque 350 (concentration of iodine was 350 g/L) was inserted into anterior vein of elbow with 18G trochar retained with high-pressured injectoc pum. The speed was 4.5 mL/s and the total volume was 80-100 mL with the means of 90 mL. Scan started at 10-20 s after injection of contrast medium. Original image was dealt with Leonardo workstation and retreated with Syngo software. Volume rendering and maximum intensity projection were used to reconstructed images, (2) All 106 patients suffered from occlusion of aneurysm clamp. Before operation, 3D-CTA was undertaken and DSA was followed. After operation, patients were rechecked with 3D-CTA. MAIN OUTCOME MEASURES: Comparisons between 3D-CTA and DSA. RESULTS : All 106 patients were involved in the final analysis. (1) Examination of 3D-CTA and DSA: Among 118 patients with aneurysm, 110 were checked with 3D-CTA and the detected rate was 93.2% (110/118). Among other 8 cases, 3 were negative and checked again with DSA; 1 had pericallosal aneurysm, 1 ophthalmic aneurysm, and 1 anterior choroidal artery of aneurysm. 3D-CTA results of other 5 cases were suspicious, and then, they were regarded as having aneurysm with DSA. Before operation, correlation among site, body, neck of aneurysm and peripheral anatomic structure were shown sufficiently. After operation, 82 patients were rechecked with 3D-CTA, which was complete occlusion, precise, unobvious constriction, emphraxis or remains as compared with 3D-CTA those pre-operation. (2) Characteristics of 3D-CTA: With multiple vessels and angles, 3D-CTA observed the relationship between aneurysm neck and carried artery and showed thrombosis in cavity of aneurysm, calcification of aneurysm wall and peripheral structure of vessel at the same time. However, DSA could not detect the reactions mentioned above. It could delete image of cranium, simulate image of operative route, eliminate artifact induced by metal, but not distinguish blood stream direction. Meanwhile, posterior communicating artery was always poor during circle of Willis artery showing. CONCLUSION: (1) 3D-CTA is characterized by simple operation and non-invasive showing vascular stereo structure and correlation. Therefore, it is significant for diagnosis and designing plan of operative approach and focal location pre-operation and evaluating effect post-operation. (2) 3D-CTA does not completely replace DSA on the diagnosis of intracranial aneurysm. 展开更多
关键词 Preoperative diagnosis and operative effect of intracranial aneurysm with three-dimensional computed tomography angiography CTA
下载PDF
Three-dimensional visualization of soil pore structure using computed tomography 被引量:1
11
作者 Qiaoling Han Xibo Zhou +2 位作者 Lei Liu Yandong Zhao Yue Zhao 《Journal of Forestry Research》 SCIE CAS CSCD 2019年第3期1053-1061,共9页
The geometric and spatial characteristics of pore structures determine the permeability and water retention of soils, which have important effects on soil functional diversity and ecological restoration. Until recentl... The geometric and spatial characteristics of pore structures determine the permeability and water retention of soils, which have important effects on soil functional diversity and ecological restoration. Until recently, there have not been tools and methods to visually and quantitatively describe the characteristics of soil pores. To solve this problem, this research reconstructs the geometry and spatial distribution of soil pores by the marching cubes method, texture mapping method and the ray casting method widely used in literature. The objectives were to explore an optimal method for three-dimensional visualization of soil pore structure by comparing the robustness of the three methods on soil CT images with single pore structure and porosity ranging from low (2–5%) to high (12–18%), and to evaluate the reconstruction performance of the three methods with different geometric features. The results demonstrate that there are aliases (jagged edges) and deficiency at the boundaries of the model reconstructed by the marching cubes method and pore volumes are smaller than the ground truth, whereas the results of the texture mapping method lack the details of pore structures. For all the soil images, the ray casting method is preferable since it better preserves the pore characteristics of the ground truth. Furthermore, the ray casting method produced the best soil pore model with higher rendering speed and lower memory consumption. Therefore, the ray casting method provides a more advanced method for visualization of pore structures and provides an optional technique for the study of the transport of moisture and the exchange of air in soil. 展开更多
关键词 Soil PORE STRUCTURE X-ray computed tomography three-dimensional reconstruction PORE VISUALIZATION
下载PDF
Hybrid reconstruction algorithm for computed tomography based on diagonal total variation 被引量:1
12
作者 Lu-Zhen Deng Peng He +3 位作者 Shang-Hai Jiang Mian-Yi Chen Biao Wei Peng Feng 《Nuclear Science and Techniques》 SCIE CAS CSCD 2018年第3期172-180,共9页
Inspired by total variation(TV), this paper represents a new iterative algorithm based on diagonal total variation(DTV) to address the computed tomography image reconstruction problem. To improve the quality of a reco... Inspired by total variation(TV), this paper represents a new iterative algorithm based on diagonal total variation(DTV) to address the computed tomography image reconstruction problem. To improve the quality of a reconstructed image, we used DTV to sparsely represent images when iterative convergence of the reconstructed algorithm with TV-constraint had no effect during the reconstruction process. To investigate our proposed algorithm, the numerical and experimental studies were performed, and rootmean-square error(RMSE) and structure similarity(SSIM)were used to evaluate the reconstructed image quality. The results demonstrated that the proposed method could effectively reduce noise, suppress artifacts, and reconstruct highquality image from incomplete projection data. 展开更多
关键词 computed tomography (CT) Sparse-view reconstruction DIAGONAL total variation (DTV) COMPRESSIVE sensing (CS)
下载PDF
Three-dimensional computed tomography mapping of posterior malleolar fractures 被引量:2
13
作者 Qi-Hang Su Juan Liu +5 位作者 Yan Zhang Jun Tan Mei-Jun Yan Kai Zhu Jin Zhang Cong Li 《World Journal of Clinical Cases》 SCIE 2020年第1期29-37,共9页
BACKGROUND Posterior malleolar fractures have been reported to occur in<40%of ankle fractures.AIM To reveal the recurrent patterns and characteristics of posterior malleolar fractures by creating fracture maps of t... BACKGROUND Posterior malleolar fractures have been reported to occur in<40%of ankle fractures.AIM To reveal the recurrent patterns and characteristics of posterior malleolar fractures by creating fracture maps of the posterior malleolar fractures through the use of computed tomography mapping.METHODS A consecutive series of posterior malleolar fractures was used to create threedimensional reconstruction images,which were oriented and superimposed to fit an ankle model template by both aligning specific biolandmarks and reducing reconstructed fracture fragments.Fracture lines were found and traced in order to generate an ankle fracture map.RESULTS This study involved 112 patients with a mean age of 49,comprising 32 pronationexternal rotation grade IV fractures and 80 supination-external rotation grade IV fractures according to the Lauge-Hansen classification system.Three-dimensional maps showed that the posterior ankle fracture fragments in the supinationexternal rotation grade IV group were relatively smaller than those in the pronation-external rotation grade IV group after posterior malleolus fracture.In addition,the distribution analyses on posterior malleolus fracture lines indicated that the supination-external rotation grade IV group tended to have higher linear density but more concentrated and orderly distribution fractures compared to the pronation-external rotation grade IV group.CONCLUSION Fracture maps revealed the fracture characteristics and recurrent patterns of posterior malleolar fractures,which might help to improve the understanding of ankle fracture as well as increase opportunities for follow-up research and aid clinical decision-making. 展开更多
关键词 three-dimensional imaging MAPS Ankle fractures computed tomography
下载PDF
Terahertz Three-Dimensional Imaging Based on Computed Tomography with Photonics-Based Noise Source 被引量:3
14
作者 周涛 张戎 +3 位作者 姚辰 符张龙 邵棣祥 曹俊诚 《Chinese Physics Letters》 SCIE CAS CSCD 2017年第8期76-78,共3页
Computed tomography has been proven to be useful for non-destructive inspection of structures and materials. We build a three-dimensional imaging system with the photonically generated incoherent noise source and the ... Computed tomography has been proven to be useful for non-destructive inspection of structures and materials. We build a three-dimensional imaging system with the photonically generated incoherent noise source and the Schottky barrier diode detector in the terahertz frequency band (90–140GHz). Based on the computed tomography technique, the three-dimensional image of a ceramic sample is reconstructed successfully by stacking the slices at different heights. The imaging results not only indicate the ability of terahertz wave in the non-invasive sensing and non-destructive inspection applications, but also prove the effectiveness and superiority of the uni-traveling-carrier photodiode as a terahertz source in the imaging applications. 展开更多
关键词 THz Terahertz three-dimensional Imaging Based on computed tomography with Photonics-Based Noise Source
下载PDF
Three-Dimensional Computed Tomography Assessment and Planning for Severe Lower Limb Deformities: A Case Report of Bilateral Fibular Hemimelia 被引量:2
15
作者 Yoshiteru Kawasaki Mitsuhiko Takahashi Natsuo Yasui 《Open Journal of Orthopedics》 2013年第3期167-171,共5页
To correct a lower limb deformity, orthopedic surgeons must have an exact understanding of the deformity. In general, preoperative planning is carried out using anterior-posterior (AP) and lateral radiographs. However... To correct a lower limb deformity, orthopedic surgeons must have an exact understanding of the deformity. In general, preoperative planning is carried out using anterior-posterior (AP) and lateral radiographs. However, for severe cases with a combination of angular and rotational deformities of the lower limb, obtaining true AP and lateral radiographs is difficult and accurate calculation of the rotational deformity from radiographs is impossible. In this report, we propose to focus on preoperative assessment using three-dimensional (3D) reconstruction images of computed tomography (CT) scans for severe lower limb deformity in a patient with bilateral fibular hemimelia type II according to the Achterman- Kalamchi classification. She underwent bifocal deformity corrections of the bilateral tibiae using Taylor spatial frames in combination with the Ilizarov external fixator. Complete bony union was achieved, without angular deformity or limb length discrepancy. 展开更多
关键词 DEFORMITY Correction PREOPERATIVE PLANNING three-dimensional computed tomography FIBULAR Hemimelia TAYLOR Spatial Frame
下载PDF
Three-dimensional stereotactic surface projection in the statistical analysis of single photon emission computed tomography data for distinguishing between Alzheimer's disease and depression 被引量:1
16
作者 Eiji Kirino 《World Journal of Psychiatry》 SCIE 2017年第2期121-127,共7页
AIM To evaluate usefulness of single photon emission computed tomography(SPECT) with three-dimensional stereotactic surface projection(3D-SSP) in distinguishing between Alzheimer's disease(AD) and depression.METHO... AIM To evaluate usefulness of single photon emission computed tomography(SPECT) with three-dimensional stereotactic surface projection(3D-SSP) in distinguishing between Alzheimer's disease(AD) and depression.METHODS We studied 43 patients who presented with both depressive symptoms and memory disturbance. Each subject was evaluated using the following:(1) the Minimal Mental State Examination;(2) the Hamilton Rating Scale for Depression;(3) Clinical Global Impression-Severity scale(CGI-S); and(4) SPECT imaging with 3D-SSP.RESULTS The MMSE scores correlated significantly with the maximum Z-scores of AD-associated regions. CGI-S scores correlated significantly with the maximum Z-scores of depression-associated regions. Factor analysis identified three significant factors. Of these, Factor 1 could be interpreted as favouring a tendency for AD, Factor 2 as favouring a tendency for pseudo-dementia, and Factor 3 as favouring a depressive tendency.CONCLUSION We investigated whether these patients could be categorized as types: Type A(true AD), Type B(pseudodementia), Type C(occult AD), and Type D(true depression). The factor scores in factor analysis supported the validity of this classification. Our results suggest that SPECT with 3D-SSP is highly useful for distinguishing between depression and depressed mood in the early stage of AD. 展开更多
关键词 Alzheimer’s disease three-dimensional STEREOTACTIC surface projection Single photon emission computed tomography Pseudo-dementia DEPRESSION
下载PDF
Optimization-based image reconstruction in x-ray computed tomography by sparsity exploitation of local continuity and nonlocal spatial self-similarity 被引量:1
17
作者 张瀚铭 王林元 +3 位作者 李磊 闫镔 蔡爱龙 胡国恩 《Chinese Physics B》 SCIE EI CAS CSCD 2016年第7期557-565,共9页
The additional sparse prior of images has been the subject of much research in problems of sparse-view computed tomography(CT) reconstruction. A method employing the image gradient sparsity is often used to reduce t... The additional sparse prior of images has been the subject of much research in problems of sparse-view computed tomography(CT) reconstruction. A method employing the image gradient sparsity is often used to reduce the sampling rate and is shown to remove the unwanted artifacts while preserve sharp edges, but may cause blocky or patchy artifacts.To eliminate this drawback, we propose a novel sparsity exploitation-based model for CT image reconstruction. In the presented model, the sparse representation and sparsity exploitation of both gradient and nonlocal gradient are investigated.The new model is shown to offer the potential for better results by introducing a similarity prior information of the image structure. Then, an effective alternating direction minimization algorithm is developed to optimize the objective function with a robust convergence result. Qualitative and quantitative evaluations have been carried out both on the simulation and real data in terms of accuracy and resolution properties. The results indicate that the proposed method can be applied for achieving better image-quality potential with the theoretically expected detailed feature preservation. 展开更多
关键词 computed tomography image reconstruction sparsity exploitation nonlocal gradient
下载PDF
Preliminary clinical application of an adaptive iterative statistical reconstruction algorithm inhead and neck computed tomography angiography with low tube voltage and a low concentration of contrast medium 被引量:1
18
作者 Shan Hu Wenzhen Zhu +4 位作者 Daoyu Hu XiaoYan Meng Jinhua Zhang Weijia Wan Li Zhou 《Oncology and Translational Medicine》 CAS 2015年第4期171-176,共6页
Objective To evaluate the feasibility of using a low concentration of contrast medium(Visipaque 270 mg I/m L), low tube voltage, and an advanced image reconstruction algorithm in head and neck computed tomography angi... Objective To evaluate the feasibility of using a low concentration of contrast medium(Visipaque 270 mg I/m L), low tube voltage, and an advanced image reconstruction algorithm in head and neck computed tomography angiography(CTA).Methods Forty patients(22 men and 18 women; average age 48.7 ± 14.25 years; average body mass index 23.9 ± 3.7 kg/m2) undergoing CTA for suspected vascular diseases were randomly assigned into two groups. Group A(n = 20) was administered 370 mg I/m L contrast medium, and group B(n = 20) was administered 270 mg I/m L contrast medium. Both groups were administered at a rate of 4.8 m L/s and an injection volume of 0.8 m L/kg. Images of group A were obtained with 120 k Vp and filtered back projection(FBP) reconstruction, whereas images of group B were obtained with 80 k Vp and 80% adaptive iterative statistical reconstruction algorithm(ASi R). The CT values and standard deviations of intracranial arteries and image noise on the corona radiata were measured to calculate the contrast-to-noise ratio(CNR) and signal-to-noise ratio(SNR). The beam-hardening artifacts(BHAs) around the skull base were calculated. Two readers evaluated the image quality with volume rendered images using scores from 1 to 5. The values between the two groups were statistically compared.Results The mean CT value of the intracranial arteries in group B was significantly higher than that in group A(P < 0.001). The CNR and SNR values in group B were also statistically higher than those in group A(P < 0.001). Image noise and BHAs were not significantly different between the two groups. The image quality score of VR images of in group B was significantly higher than that in group A(P = 0.001). However, the quality scores of axial enhancement images in group B became significantly smaller than those in group A(P< 0.001). The CT dose index volume and dose-length product were decreased by 63.8% and 64%, respectively, in group B(P < 0.001 for both).Conclusion Visipaque combined with 80 k Vp and 80% ASi R provided similar image quality in intracranial CTA with 64% radiation dose reduction compared with the use of Iopamidol, 120 k Vp, and FBP reconstruction. 展开更多
关键词 肿瘤学 临床 理论 化疗
下载PDF
Computed Tomography Using Level Set Method and Algebraic Reconstruction Technique
19
作者 薛倩 王化祥 《Transactions of Tianjin University》 EI CAS 2011年第6期418-423,共6页
In this paper, a novel reconstruction technique based on level set method and algebraic reconstruction technique is proposed for multiphase flow computed tomography (CT) system. The curvature-driven noise reduction me... In this paper, a novel reconstruction technique based on level set method and algebraic reconstruction technique is proposed for multiphase flow computed tomography (CT) system. The curvature-driven noise reduction method is inserted into the conventional iteration procedure of algebraic reconstruction technique to improve the image quality and convergence speed with limited projection data. By evolving the image as a set of iso-intensity contours after each updation, the sufficient number of iterations for acceptable results is reduced by 80%-90%, while the image quality is enhanced obviously. Quantitative evaluation of image quality is given by using both relative image error and correlation coefficient. The resultant images can be utilized to detect flow regimes for monitoring industrial multiphase flow. Laboratory results demonstrate the feasibility of the proposed method. Phantoms of four typical flow regimes can be reconstructed from few-view projection data efficiently, and the corresponding image errors and correlation coefficients are acceptable for the cases tested in this paper. 展开更多
关键词 代数重建技术 计算机断层扫描 Level SET方法 图像质量 电脑 迭代过程 相关系数
下载PDF
Reproducibility of 3 mm-Slice-Thick Reconstruction of Paranasal Sinus Computed Tomography Scans
20
作者 Matti Karjalainen Anna Julkunen +7 位作者 Antti Markkola Prasun Dastidar Heini Huhtala Mikko Suvinen Anna-Maija Kuukka Markus Rautiainen Jura Numminen Sanna Toppila-Salmi 《Open Journal of Radiology》 2016年第1期39-48,共10页
Background: After the failure of medical treatment, the surgery of chronic rhinosinusitis (CRS) is planned according to endoscopic and paranasal sinus computed tomography (CT) findings. Objective: The aim of this pros... Background: After the failure of medical treatment, the surgery of chronic rhinosinusitis (CRS) is planned according to endoscopic and paranasal sinus computed tomography (CT) findings. Objective: The aim of this prospective study was to evaluate whether this study method might be eligible in studies aiming at radiation dose reduction. Sinus CT scans were chosen as a model because of the high variation of the radiological anatomy of surgically important sinonasal structures. We hypothesized that 3 mm-slice-thick reconstruction CT had poor reproducibility. Methods: 59 CRS patients underwent routine multi-detector sinus CT (CT<sub>MD</sub>). CT<sub>3mm</sub> was reconstructed from CT<sub>MD</sub> data-sets. Lund-Mackay (LM) scores and 43 other structural parameters were analyzed blinded. Agreement was studied between CT<sub>MD</sub> and CT<sub>3mm</sub> (intra-observer reproducibility), and between three observers (inter-observer reproducibility) by using Cohen’s kappa. Results: The inter-observer agreement was moderate (kappa 0.4 - 0.6, p < 0.01) in the majority of structures of CT<sub>3mm</sub> scans. The intra-observer reproducibility of CT<sub>3mm</sub> scans was very good in most structures, however, it was poor in important structures such as frontal and spheno-ethmoid recess, lamina papyracae, and location of optic nerve or anterior ethmoidal artery. The grade of surgeon’s confidence of CT<sub>3mm</sub> in comparison to CT<sub>MD</sub> was lower (kappa 0.2 - 0.4, P < 0.05). Conclusion: This methodology might have some use in studies aiming at radiation dose reduction. As was expected, 3 mm-slice-thick reconstruction CT had poor reproducibility and surgeon’s confidence. More recent methods such as cone beam computed tomography scans have nowadays more relevant dose reduction potential. 展开更多
关键词 Chronic Rhinosinusitis computed tomography Image reconstruction Inter-Observer Agreement Intra-Observer Agreement KAPPA Radiation-Dose Reduction REPRODUCIBILITY Paranasal Sinus Sinus Imaging
下载PDF
上一页 1 2 86 下一页 到第
使用帮助 返回顶部