BACKGROUND Diabetic cardiomyopathy is considered as a chronic complication of diabetes mellitus(DM).Therefore,early detection of left ventricular systolic function(LVSF)damage in DM is essential.AIM To explore the use...BACKGROUND Diabetic cardiomyopathy is considered as a chronic complication of diabetes mellitus(DM).Therefore,early detection of left ventricular systolic function(LVSF)damage in DM is essential.AIM To explore the use of the three-dimensional speckle tracking technique(3D-STI)for measuring LVSF in DM patients via meta-analysis.METHODS The electronic databases were retrieved from the initial accessible time to 29 April 2023.The current study involved 9 studies,including 970 subjects.We carried out this meta-analysis to estimate myocardial function in DM compared with controls according to myocardial strain attained by 3D-STI.RESULTS Night articles including 970 subjects were included.No significant difference was detected in the left ventricular ejection fraction between the control and the diabetic group(P>0.05),while differences in global longitudinal strain,global circumferential strain,global radial strain,and global area strain were markedly different between the controls and DM patients(all P<0.05).CONCLUSION The 3D-STI could be applied to accurately measure early LVSF damage in patients with DM.展开更多
In this work,a facile and effective strategy to prepare three-dimensional(3D)hierarchical flower-like Mg–Al layered double hydroxides(3D-LDH)was developed via a one-step double-drop coprecipitation method usingγ-Al ...In this work,a facile and effective strategy to prepare three-dimensional(3D)hierarchical flower-like Mg–Al layered double hydroxides(3D-LDH)was developed via a one-step double-drop coprecipitation method usingγ-Al 2O 3particles as a template.The characterization and experimental results showed that the calcined product,3D-LDO,features a large specific surface area of 204.2 m^(2)/g,abundant active sites,and excellent adsorption performance for Congo red(CR),methyl orange(MO),and methyl blue(MB).The maximum adsorption capacities of 3D-LDO for CR,MO,and MB were 1428.6,476.2,and 1666.7 mg/g,respectively;such performance is superior to that of most reported adsorbents.The adsorption mechanism of organic anionic dyes by 3D-LDO was extensively investigated and attributed to surface adsorption,the memory effect of 3D-LDO,and the unique 3D hierarchical flower-like structure of the adsorbent.Recycling performance tests revealed that3D-LDO has satisfactory reusability for the three organic anionic dyes.展开更多
The application of real-time three-dimensional echocardiography (RT 3DE) in the diagnosis of double orifice mitral valve (DOMV) was explored. Five cases of DOMV were examined by using 2-dimensional echocardiograp...The application of real-time three-dimensional echocardiography (RT 3DE) in the diagnosis of double orifice mitral valve (DOMV) was explored. Five cases of DOMV were examined by using 2-dimensional echocardiography (2DE) and RT 3DE. The spatial morphology of malformed mitral valve and its change in hemodynamics were observed. DOMV associated with partial atrioventricular septal defect was found in 3 cases (in which 2 cases had cleft mitral valve) and isolated DOMV in 2 cases; and moderate to severe mitral regurgitation was detected in 3 cases, and mild mitral regurgitation in 1, and no regurgitation in 1 case; 1 case had complicated rhumatic heart disease. Three cases were preoperatively discovered by 2DE, while 2 missed (1 case was discovered postoperatively). Four cases were diagnosed by RT 3DE preoperatively, and 1 case was diagnosed postoperatively (not examined by RT 3DE preoperatively). It was suggested that RT 3DE is a reliable technique in the diagnosis of DOMV; it permitted comprehensive and noninvasive assessment of mitral valve and may supplement 2D TTE in the assessment of DOMV.展开更多
A series of related electrophysiology phenomena can be caused by the occurrence of interpolated ventricular premature contraction.In our recent three-dimensional Lorenz R-R scatter plot research,we found that atrioven...A series of related electrophysiology phenomena can be caused by the occurrence of interpolated ventricular premature contraction.In our recent three-dimensional Lorenz R-R scatter plot research,we found that atrioventricular node double path caused by interpolated ventricular premature contraction imprints a specifi c pattern on three-dimensional Lorenz plots generated from 24-hour Holter recordings.We found two independent subclusters separated from the interpolated premature beat precluster,the interpolated premature beat cluster,and the interpolated premature beat postcluster,respectively.Combined with use of the trajectory tracking function and the leap phenomenon,our results reveal the presence of the atrioventricular node double conduction path.展开更多
Objective To evaluate left atrial function in essential hypertension patients with different patterns of left ventricular geometric models by real-time three-dimensional echocardiography (RT-3DE) and left atrial tra...Objective To evaluate left atrial function in essential hypertension patients with different patterns of left ventricular geometric models by real-time three-dimensional echocardiography (RT-3DE) and left atrial tracking (EAT).展开更多
The Kuroshio Extension(KE)is one of the most eddy-energetic regions in the global ocean.However,most mesoscale eddy studies in the region are focused on surface eddies and the structure and characteristics of three-di...The Kuroshio Extension(KE)is one of the most eddy-energetic regions in the global ocean.However,most mesoscale eddy studies in the region are focused on surface eddies and the structure and characteristics of three-dimensional(3-D)eddies require additional research.In this study,we proposed a 3-D eddy identification and tracking algorithm based on pressure anomalies,similar to sea level anomalies(SLAs)for surface eddy identification.We applied this scheme to a 5-year(2008-2012)high-resolution numerical product to develop a 3-D eddy dataset in the KE.The reliability of the numerical product was verified by the 5-year temperature/salinity hydrological characteristics and surface eddy distribution.According to the 3-D eddy tracking dataset,the number of eddies decreased dramatically as the eddy existence-time increased and more anticyclonic eddies(AEs)had an existence-time longer than 1 week than cyclonic eddies(CEs).We presented daily variations in the 3-D structure of two 3-D eddy-tracking trajectories that exhibit a certain jump in depth and a shift toward the west and equator.In addition to the bowl,lens,and cone eddies that have been discovered by previous researchers,we found that there is a cylindrical eddy,and its eddy radii are almost consistent across all layers.CEs cause significant negative temperature anomalies,“negative-positive”salinity anomalies,and sinking current fields in the KE region,while AEs cause positive temperature anomalies,“positive-negative”salinity anomalies,and upward current fields.The four types of eddies have different effects on the temperature/salinity anomalies and current field distribution which are related to their structure.展开更多
A 63-year-old man presented at our hospital with right upper abdomen pain and fever for 4 d.The patient's magnetic resonance cholangiopancreatography revealed dilated common bile duct and choledocholithiasis.In hi...A 63-year-old man presented at our hospital with right upper abdomen pain and fever for 4 d.The patient's magnetic resonance cholangiopancreatography revealed dilated common bile duct and choledocholithiasis.In his past history,he received proximal gastrectomy and modified double tracks anastomosis.Endoscopic retrograde cholangiopancretography in modified double tracks anastomosis,especially accompanied with anastomotic stenosis,has been rarely reported.In the present case,the duodenoscope was successfully introduced over the guidewire and the stone taken out using a basket.The patient had good palliation of his symptoms after removal of the stone.展开更多
The double pulse sources (DPS) method is presented for linear track estimation in this work. In the field of noise identification of underwater moving target, the Doppler will distort the frequency and amplitude of ...The double pulse sources (DPS) method is presented for linear track estimation in this work. In the field of noise identification of underwater moving target, the Doppler will distort the frequency and amplitude of the radiated noise. To eliminate this, the track estimation is necessary. In the DPS method, we first estimate bearings of two sinusoidal pulse sources installed in the moving target through baseline positioning method. Meanwhile, the emitted and recorded time of each pulse are also acquired. Then the linear track parameters will be achieved based on the geometry pattern with the help of double sources spacing. The simulated results confirm that the DPS improves the performance of the previous double source spacing method. The simulated experiments were carried out using a moving battery car to further evaluate its performance. When the target is 40-60m away, the experiment results show that biases of track azimuth and abeam distance of DPS are under 0.6° and 3.4m, respectively. And the average deviation of estimated velocity is around 0.25m/s.展开更多
Three-dimensional speckle tracking echocardiography was employed to evaluate the changes of left ventricular systolic strain in 23 heart transplant recipients at 1 st, 3rd, 6th and 12th month after heart transplantati...Three-dimensional speckle tracking echocardiography was employed to evaluate the changes of left ventricular systolic strain in 23 heart transplant recipients at 1 st, 3rd, 6th and 12th month after heart transplantation, and 23 healthy subjects served as controls. The three-dimensional full-volume echocardiographic images of left ventricle were recorded and then were analyzed using EchoPAC software. The strain curves and peak systolic strain values for each segment and overall left ventricular wall were obtained. Left ventricular global peak longitudinal strain (GPSL), global peak radial strain (GPSR), global peak circumferential strain (GPSC) and global peak area strain (GPSA) were measured and then statistically analyzed. There were no significant differences in left ventricular ejection fraction (LVEF) and cardiac output (CO) between heart transplant recipients and controls. The GPSL in heart transplant recipients at 1st month after surgery was significantly lower than that in controls, but close to the normal value at 3rd month after surgery and later. The GPSC, GPSA and GPSR were significantly lower in heart transplant recipients at 1 st, 3rd, 6th and 12th month after surgery than those in controls. It is suggested that three-dimensional speckle tracking echocardiography can be used for monitoring changes of left ventricular systolic strains and evaluating left ventricular systolic function in cardiac allograft.展开更多
Objective:To investigate the value of two-dimensional ultrasound speckle tracking(2D-STI)and three-dimensional ultrasound speckle tracking(3D-STI)in evaluating myocardial function in children with Kawasaki disease.Met...Objective:To investigate the value of two-dimensional ultrasound speckle tracking(2D-STI)and three-dimensional ultrasound speckle tracking(3D-STI)in evaluating myocardial function in children with Kawasaki disease.Methods 92 children with Kawasaki disease admitted to our hospital from February 2017 to February 2019 were retrospectively analyzed.50 children who underwent 3D-STI examination were taken as observation group and 42 children who underwent 2D-STI examination were taken as control group.The left ventricular systolic function index,storage time and analysis time of the image,the diameter of coronary artery,the strain difference of left ventricular basal segment,middle segment,apical segment and whole segment were observed.Results The levels of left ventricular end-diastolic volume(LVEDV),left ventricular end-systolic volume(LVESV),left ventricular myocardial mass(LVMI)in the observation group were higher than those in the control group(P<0.05),but there was no statistical difference in left ventricular ejection fraction(LVEF)between the two groups(P>0.05).The storage time and analysis time of the image in the observation group were significantly lower than those in the control group(P<0.05).The left coronary artery(LCA)and right coronary artery(RCA)in the observation group were higher than those in the control group(P<0.05).There was no statistical difference between left anterior descending(LAD)in the two groups(P>0.05).The longitudinal peak systolic strain(LS),circumferential peak systolic strain(CS)and radial peak systolic strain(RS)in the observation group were higher than those in the control group(P<0.05).The global longitudinal peak strain(GLS),global circumferential peak strain(GCS)and global radial peak strain(GRS)in the observation group were higher than those in the control group(P<0.05).LS and CS in the middle segment of the observation group were higher than those in the control group(P<0.05).Conclusions Compared with 2D-STI,3D-STI can objectively and accurately reflect the myocardial function of children with Kawasaki disease.展开更多
Objective: To study the correlation between three-dimensional speckle tracking imaging (3D-STI) parameter global area strain (GAS) and the cardiotoxicity of chemotherapeutics in patients with lung cancer chemotherapy....Objective: To study the correlation between three-dimensional speckle tracking imaging (3D-STI) parameter global area strain (GAS) and the cardiotoxicity of chemotherapeutics in patients with lung cancer chemotherapy. Methods: Patients with lung cancer who underwent chemotherapy in the Second Affiliated Hospital of Xi'an Medical University between February 2016 and May 2017 were selected as the chemotherapy group, the healthy subjects who received physical examination during the same period were selected as the control group, the 3D-STI examination was performed and GAS was calculated;the serum was collected to determine the contents of cardiotoxicity markers as well as apoptosis and oxidative stress indexes, and the peripheral blood was collected to determine the expression of apoptosis and oxidative stress molecules. Results: GAS level, serum ALDH2 and CAT contents as well as peripheral blood Keap1 and Bcl-2 expression intensity of chemotherapy group were lower than those of control group whereas serum Copeptin, CK-MB, cTnI, cMyBP-c, sTWEAK, sFas, MDA and 8-isoPGF2α contents as well as peripheral blood Nrf-2, gp91phox, p22 phox and Caspase-3 expression intensity were significantly higher than those of control group;the GAS level in chemotherapy group was negatively correlated with serum Copeptin, CK-MB, cTnI, cMyBP-c, sTWEAK, sFas, MDA and 8-isoPGF2α contents as well as peripheral blood Nrf-2, gp91phox, p22 phox and Caspase-3 expression intensity, and positively correlated with serum ALDH2 and CAT contents as well as peripheral blood Keap1 and Bcl-2 expression intensity. Conclusion: The changes of 3D-STI parameter GAS in patients with lung cancer chemotherapy can reflect the degree of cardiotoxicity induced by oxidative stress and apoptosis.展开更多
Objective:To study the correlation between three-dimensional speckle tracking parameters and serum index changes during left ventricular remodeling in patients with coronary heart disease. Methods: Patients who were d...Objective:To study the correlation between three-dimensional speckle tracking parameters and serum index changes during left ventricular remodeling in patients with coronary heart disease. Methods: Patients who were diagnosed with coronary heart disease and angina pectoris in our hospital between March 2015 and May 2017 were selected as the CHD group of the study, and the healthy subjects who received medical examination in our hospital during the same period were taken as the control group;the three-dimensional speckle tracking parameters, peripheral blood signal molecule expression as well as serum cytokine and collagen metabolism index levels of the two groups were measured.Results: GLS and AGS levels in CHD group were significantly lower than those in control group whereas GCS and GRS levels were not significantly different from those in control group, and peripheral blood Notch1, Hes1, NF-κB and PKC expression intensity as well as serum sTWEAK, FGF23, TGF-β1, GDF15, sSema4D, CaN, MMP14, PINP and ICTP contents were significantly higher than those of control group;GLS and AGS levels in CHD group were negatively correlated with peripheral blood Notch1, Hes1, NF-κB and PKC expression intensity as well as serum sTWEAK, FGF23, TGF-β1, GDF15, sSema4D, CaN, MMP14, PINP and ICTP contents.Conclusions:The changes of three-dimensional speckle tracking parameters GLS and AGS in patients with coronary heart disease are closely related to the changes in signal pathway function, cytokine secretion and collagen metabolism during left ventricular remodeling.展开更多
The authoros specialize in the field of optunization and automatic programme oftrain working graph. In this peper, at frist, a mixed 0-1 integer progranimingmodel about this problem for duuble-track lines is set up, t...The authoros specialize in the field of optunization and automatic programme oftrain working graph. In this peper, at frist, a mixed 0-1 integer progranimingmodel about this problem for duuble-track lines is set up, then the principle andProcess of selution are stated, with an application exaiiiple put forward.展开更多
With the continuous development of digital medicine,minimally invasive precision and safety have become the primary development trends in hepatobiliary surgery.Due to the specificity and complexity of hepatobiliary su...With the continuous development of digital medicine,minimally invasive precision and safety have become the primary development trends in hepatobiliary surgery.Due to the specificity and complexity of hepatobiliary surgery,traditional preoperative imaging techniques such as computed tomography and magnetic resonance imaging cannot meet the need for identification of fine anatomical regions.Imaging-based three-dimensional(3D)reconstruction,virtual simulation of surgery and 3D printing optimize the surgical plan through preoperative assessment,improving the controllability and safety of intraoperative operations,and in difficult-to-reach areas of the posterior and superior liver,assistive robots reproduce the surgeon’s natural movements with stable cameras,reducing natural vibrations.Electromagnetic navigation in abdominal surgery solves the problem of conventional surgery still relying on direct visual observation or preoperative image assessment.We summarize and compare these recent trends in digital medical solutions for the future development and refinement of digital medicine in hepatobiliary surgery.展开更多
A magnitude 5.5 earthquakes occurred in Eryuan County,Dali Bai Autonomous Prefecture,Yunnan Province,China,on March 3.And a magnitude 5.0 earthquake occurred in the same place on April 17,2013,i.e.,45 days later.Then,...A magnitude 5.5 earthquakes occurred in Eryuan County,Dali Bai Autonomous Prefecture,Yunnan Province,China,on March 3.And a magnitude 5.0 earthquake occurred in the same place on April 17,2013,i.e.,45 days later.Then,on May 21,2021,multiple earthquakes,one with magnitude 6.4 and several at 5.0 or above,occurred in Yangbi County,Dali Bai Autonomous Prefecture,Yunnan Province,China.All of these occurred in the Weixi-QiaohouWeishan fault zone.In this study,1,874 seismic events in Yangbi and Eryuan counties were identified by automatic micro-seismic identification technology and the first arrivals were picked up manually.Following this,a total of 11,968 direct P-wave absolute arrivals and 73,987 high-quality Pwave relative arrivals were collected for joint inversion via the double difference tomography method.This was done to obtain the regional three-dimensional fine crustal P-wave velocity structure.The results show that the travel time residuals before and after inversion decreased from the initial–0.1–0.1 s to–0.06–0.06 s.The upper crust in the study area,which exhibited a low-velocity anomaly,corresponded to the basin region;this indicated that the low-velocity anomaly in the shallow part of the study area was affected by the basin.Results also showed some correlation between the distribution of the earthquakes and velocity structure,as there was a lowvelocity body Lv1 with a wide distribution at depths ranging from 15–20 km in the Yangbi and Eryuan earthquake regions.In addition,earthquakes occurred predominantly in the highlow velocity abnormal transition zone.The low-velocity body in the middle and lower crust may be prone to concentrating upper crustal stress,thus leading to the occurrence of earthquakes.展开更多
The 2016 MW7.8 Kaikoura earthquake struck the northern part of south Island,New Zealand,within the active and complex Australia-Pacific plate boundary system.Firstly,we used the InSAR method to obtain coseismic LOS de...The 2016 MW7.8 Kaikoura earthquake struck the northern part of south Island,New Zealand,within the active and complex Australia-Pacific plate boundary system.Firstly,we used the InSAR method to obtain coseismic LOS deformation fields based on SAR images and applied offset tracking methods to obtain offset measurements based on optical satellite images.The maximum displacement of about 6 m is detected in the direction away from the satellite on the south-west side and also towards the satellite on the north-east side.The 3D deformation field is then resolved by the combination of these measurements with a least-square solve method,and comparisons with 3 components of GPS stations show good consistency.Despite complex features demonstrated in the 3D deformation field,there are still clear spatial correlations between surface deformation and faults distribution.It reveals that more than ten faults were ruptured during the earthquake,including some faults were previously understudies for their tectonic activities.The maximum horizontal deformation of about 10 m occurs along the Kekerengu fault with the vertical deformation up to 2 m.The 3D deformation shows that the mainshock is a multisegments faulting with a rupture process of strike-slip,compression,transpressional rupture and strike-slip in space along the NE direction.展开更多
We proposed a three-dimensional (3D) image authentication method using binarized phase images in double random phase integral imaging (Ini). Two-dimensional (2D) element images obtained from Ini are encoded using a do...We proposed a three-dimensional (3D) image authentication method using binarized phase images in double random phase integral imaging (Ini). Two-dimensional (2D) element images obtained from Ini are encoded using a double random phase encryption (DRPE) algorithm. Only part of the phase information is used in the proposed method rather than using all of the amplitude and phase information, which can make the final data sparse and beneficial to data compression, storage, and transmission. Experimental results verified the method and successfully proved the developed 3D authentication process using a nonlinear cross correlation method.展开更多
Satisfactory results cannot be obtained when three-dimensional (3D) targets with complex maneuvering characteristics are tracked by the commonly used two-dimensional coordinated turn (2DCT) model. To address the probl...Satisfactory results cannot be obtained when three-dimensional (3D) targets with complex maneuvering characteristics are tracked by the commonly used two-dimensional coordinated turn (2DCT) model. To address the problem of 3D target tracking with strong maneuverability, on the basis of the modified three-dimensional variable turn (3DVT) model, an adaptive tracking algorithm is proposed by combining with the cubature Kalman filter (CKF) in this paper. Through ideology of real-time identification, the parameters of the model are changed to adjust the state transition matrix and the state noise covariance matrix. Therefore, states of the target are matched in real-time to achieve the purpose of adaptive tracking. Finally, four simulations are analyzed in different settings by the Monte Carlo method. All results show that the proposed algorithm can update parameters of the model and identify motion characteristics in real-time when targets tracking also has a better tracking accuracy.展开更多
A new tracking algorithm is proposed aiming at the tracking problem in low bit signal-to- noise ratio (i. e. , Eb/N0 ) scenarios, in which the bit clock regenerated by bit synchronization loop decides loop update mo...A new tracking algorithm is proposed aiming at the tracking problem in low bit signal-to- noise ratio (i. e. , Eb/N0 ) scenarios, in which the bit clock regenerated by bit synchronization loop decides loop update moment. The double frequency processing and non-coherent accumulation tech- nologies are applied to eliminate the impact of data polarity inversion, and then long time accumula- tion improves the input signal-to-noise ratio of discriminator. The frequency locked loop and phase locked loop constitute a carrier loop in parallel, which can meet the high dynamic demands. The ef- fectiveness of this algorithm has been corroborated by theoretical analysis, simulation and measure- ments, and the new tracking algorithm has been used in an aerospace engineering project successfully.展开更多
文摘BACKGROUND Diabetic cardiomyopathy is considered as a chronic complication of diabetes mellitus(DM).Therefore,early detection of left ventricular systolic function(LVSF)damage in DM is essential.AIM To explore the use of the three-dimensional speckle tracking technique(3D-STI)for measuring LVSF in DM patients via meta-analysis.METHODS The electronic databases were retrieved from the initial accessible time to 29 April 2023.The current study involved 9 studies,including 970 subjects.We carried out this meta-analysis to estimate myocardial function in DM compared with controls according to myocardial strain attained by 3D-STI.RESULTS Night articles including 970 subjects were included.No significant difference was detected in the left ventricular ejection fraction between the control and the diabetic group(P>0.05),while differences in global longitudinal strain,global circumferential strain,global radial strain,and global area strain were markedly different between the controls and DM patients(all P<0.05).CONCLUSION The 3D-STI could be applied to accurately measure early LVSF damage in patients with DM.
基金supported by the National Key R&D Program of China(No.2017YFB0602702-02)。
文摘In this work,a facile and effective strategy to prepare three-dimensional(3D)hierarchical flower-like Mg–Al layered double hydroxides(3D-LDH)was developed via a one-step double-drop coprecipitation method usingγ-Al 2O 3particles as a template.The characterization and experimental results showed that the calcined product,3D-LDO,features a large specific surface area of 204.2 m^(2)/g,abundant active sites,and excellent adsorption performance for Congo red(CR),methyl orange(MO),and methyl blue(MB).The maximum adsorption capacities of 3D-LDO for CR,MO,and MB were 1428.6,476.2,and 1666.7 mg/g,respectively;such performance is superior to that of most reported adsorbents.The adsorption mechanism of organic anionic dyes by 3D-LDO was extensively investigated and attributed to surface adsorption,the memory effect of 3D-LDO,and the unique 3D hierarchical flower-like structure of the adsorbent.Recycling performance tests revealed that3D-LDO has satisfactory reusability for the three organic anionic dyes.
文摘The application of real-time three-dimensional echocardiography (RT 3DE) in the diagnosis of double orifice mitral valve (DOMV) was explored. Five cases of DOMV were examined by using 2-dimensional echocardiography (2DE) and RT 3DE. The spatial morphology of malformed mitral valve and its change in hemodynamics were observed. DOMV associated with partial atrioventricular septal defect was found in 3 cases (in which 2 cases had cleft mitral valve) and isolated DOMV in 2 cases; and moderate to severe mitral regurgitation was detected in 3 cases, and mild mitral regurgitation in 1, and no regurgitation in 1 case; 1 case had complicated rhumatic heart disease. Three cases were preoperatively discovered by 2DE, while 2 missed (1 case was discovered postoperatively). Four cases were diagnosed by RT 3DE preoperatively, and 1 case was diagnosed postoperatively (not examined by RT 3DE preoperatively). It was suggested that RT 3DE is a reliable technique in the diagnosis of DOMV; it permitted comprehensive and noninvasive assessment of mitral valve and may supplement 2D TTE in the assessment of DOMV.
文摘A series of related electrophysiology phenomena can be caused by the occurrence of interpolated ventricular premature contraction.In our recent three-dimensional Lorenz R-R scatter plot research,we found that atrioventricular node double path caused by interpolated ventricular premature contraction imprints a specifi c pattern on three-dimensional Lorenz plots generated from 24-hour Holter recordings.We found two independent subclusters separated from the interpolated premature beat precluster,the interpolated premature beat cluster,and the interpolated premature beat postcluster,respectively.Combined with use of the trajectory tracking function and the leap phenomenon,our results reveal the presence of the atrioventricular node double conduction path.
基金Supported by the Natural Science Foundation of Liaoning ProvinceChina(2013023010)
文摘Objective To evaluate left atrial function in essential hypertension patients with different patterns of left ventricular geometric models by real-time three-dimensional echocardiography (RT-3DE) and left atrial tracking (EAT).
文摘The Kuroshio Extension(KE)is one of the most eddy-energetic regions in the global ocean.However,most mesoscale eddy studies in the region are focused on surface eddies and the structure and characteristics of three-dimensional(3-D)eddies require additional research.In this study,we proposed a 3-D eddy identification and tracking algorithm based on pressure anomalies,similar to sea level anomalies(SLAs)for surface eddy identification.We applied this scheme to a 5-year(2008-2012)high-resolution numerical product to develop a 3-D eddy dataset in the KE.The reliability of the numerical product was verified by the 5-year temperature/salinity hydrological characteristics and surface eddy distribution.According to the 3-D eddy tracking dataset,the number of eddies decreased dramatically as the eddy existence-time increased and more anticyclonic eddies(AEs)had an existence-time longer than 1 week than cyclonic eddies(CEs).We presented daily variations in the 3-D structure of two 3-D eddy-tracking trajectories that exhibit a certain jump in depth and a shift toward the west and equator.In addition to the bowl,lens,and cone eddies that have been discovered by previous researchers,we found that there is a cylindrical eddy,and its eddy radii are almost consistent across all layers.CEs cause significant negative temperature anomalies,“negative-positive”salinity anomalies,and sinking current fields in the KE region,while AEs cause positive temperature anomalies,“positive-negative”salinity anomalies,and upward current fields.The four types of eddies have different effects on the temperature/salinity anomalies and current field distribution which are related to their structure.
基金Supported by the Key Research and Development Program of the Science and Technology Department,Jiangsu Province,China,No.BE2015722the Science and Technology Development Fund Project of Nanjing Medical University,Jiangsu Province,China,No.2011NJMU246
文摘A 63-year-old man presented at our hospital with right upper abdomen pain and fever for 4 d.The patient's magnetic resonance cholangiopancreatography revealed dilated common bile duct and choledocholithiasis.In his past history,he received proximal gastrectomy and modified double tracks anastomosis.Endoscopic retrograde cholangiopancretography in modified double tracks anastomosis,especially accompanied with anastomotic stenosis,has been rarely reported.In the present case,the duodenoscope was successfully introduced over the guidewire and the stone taken out using a basket.The patient had good palliation of his symptoms after removal of the stone.
文摘The double pulse sources (DPS) method is presented for linear track estimation in this work. In the field of noise identification of underwater moving target, the Doppler will distort the frequency and amplitude of the radiated noise. To eliminate this, the track estimation is necessary. In the DPS method, we first estimate bearings of two sinusoidal pulse sources installed in the moving target through baseline positioning method. Meanwhile, the emitted and recorded time of each pulse are also acquired. Then the linear track parameters will be achieved based on the geometry pattern with the help of double sources spacing. The simulated results confirm that the DPS improves the performance of the previous double source spacing method. The simulated experiments were carried out using a moving battery car to further evaluate its performance. When the target is 40-60m away, the experiment results show that biases of track azimuth and abeam distance of DPS are under 0.6° and 3.4m, respectively. And the average deviation of estimated velocity is around 0.25m/s.
基金supported by Innovation Research Fund of Huazhong University of Science and Technology,China(No.2012QN183)
文摘Three-dimensional speckle tracking echocardiography was employed to evaluate the changes of left ventricular systolic strain in 23 heart transplant recipients at 1 st, 3rd, 6th and 12th month after heart transplantation, and 23 healthy subjects served as controls. The three-dimensional full-volume echocardiographic images of left ventricle were recorded and then were analyzed using EchoPAC software. The strain curves and peak systolic strain values for each segment and overall left ventricular wall were obtained. Left ventricular global peak longitudinal strain (GPSL), global peak radial strain (GPSR), global peak circumferential strain (GPSC) and global peak area strain (GPSA) were measured and then statistically analyzed. There were no significant differences in left ventricular ejection fraction (LVEF) and cardiac output (CO) between heart transplant recipients and controls. The GPSL in heart transplant recipients at 1st month after surgery was significantly lower than that in controls, but close to the normal value at 3rd month after surgery and later. The GPSC, GPSA and GPSR were significantly lower in heart transplant recipients at 1 st, 3rd, 6th and 12th month after surgery than those in controls. It is suggested that three-dimensional speckle tracking echocardiography can be used for monitoring changes of left ventricular systolic strains and evaluating left ventricular systolic function in cardiac allograft.
基金Shaanxi key research and development plan(No.2019SF-211).
文摘Objective:To investigate the value of two-dimensional ultrasound speckle tracking(2D-STI)and three-dimensional ultrasound speckle tracking(3D-STI)in evaluating myocardial function in children with Kawasaki disease.Methods 92 children with Kawasaki disease admitted to our hospital from February 2017 to February 2019 were retrospectively analyzed.50 children who underwent 3D-STI examination were taken as observation group and 42 children who underwent 2D-STI examination were taken as control group.The left ventricular systolic function index,storage time and analysis time of the image,the diameter of coronary artery,the strain difference of left ventricular basal segment,middle segment,apical segment and whole segment were observed.Results The levels of left ventricular end-diastolic volume(LVEDV),left ventricular end-systolic volume(LVESV),left ventricular myocardial mass(LVMI)in the observation group were higher than those in the control group(P<0.05),but there was no statistical difference in left ventricular ejection fraction(LVEF)between the two groups(P>0.05).The storage time and analysis time of the image in the observation group were significantly lower than those in the control group(P<0.05).The left coronary artery(LCA)and right coronary artery(RCA)in the observation group were higher than those in the control group(P<0.05).There was no statistical difference between left anterior descending(LAD)in the two groups(P>0.05).The longitudinal peak systolic strain(LS),circumferential peak systolic strain(CS)and radial peak systolic strain(RS)in the observation group were higher than those in the control group(P<0.05).The global longitudinal peak strain(GLS),global circumferential peak strain(GCS)and global radial peak strain(GRS)in the observation group were higher than those in the control group(P<0.05).LS and CS in the middle segment of the observation group were higher than those in the control group(P<0.05).Conclusions Compared with 2D-STI,3D-STI can objectively and accurately reflect the myocardial function of children with Kawasaki disease.
文摘Objective: To study the correlation between three-dimensional speckle tracking imaging (3D-STI) parameter global area strain (GAS) and the cardiotoxicity of chemotherapeutics in patients with lung cancer chemotherapy. Methods: Patients with lung cancer who underwent chemotherapy in the Second Affiliated Hospital of Xi'an Medical University between February 2016 and May 2017 were selected as the chemotherapy group, the healthy subjects who received physical examination during the same period were selected as the control group, the 3D-STI examination was performed and GAS was calculated;the serum was collected to determine the contents of cardiotoxicity markers as well as apoptosis and oxidative stress indexes, and the peripheral blood was collected to determine the expression of apoptosis and oxidative stress molecules. Results: GAS level, serum ALDH2 and CAT contents as well as peripheral blood Keap1 and Bcl-2 expression intensity of chemotherapy group were lower than those of control group whereas serum Copeptin, CK-MB, cTnI, cMyBP-c, sTWEAK, sFas, MDA and 8-isoPGF2α contents as well as peripheral blood Nrf-2, gp91phox, p22 phox and Caspase-3 expression intensity were significantly higher than those of control group;the GAS level in chemotherapy group was negatively correlated with serum Copeptin, CK-MB, cTnI, cMyBP-c, sTWEAK, sFas, MDA and 8-isoPGF2α contents as well as peripheral blood Nrf-2, gp91phox, p22 phox and Caspase-3 expression intensity, and positively correlated with serum ALDH2 and CAT contents as well as peripheral blood Keap1 and Bcl-2 expression intensity. Conclusion: The changes of 3D-STI parameter GAS in patients with lung cancer chemotherapy can reflect the degree of cardiotoxicity induced by oxidative stress and apoptosis.
文摘Objective:To study the correlation between three-dimensional speckle tracking parameters and serum index changes during left ventricular remodeling in patients with coronary heart disease. Methods: Patients who were diagnosed with coronary heart disease and angina pectoris in our hospital between March 2015 and May 2017 were selected as the CHD group of the study, and the healthy subjects who received medical examination in our hospital during the same period were taken as the control group;the three-dimensional speckle tracking parameters, peripheral blood signal molecule expression as well as serum cytokine and collagen metabolism index levels of the two groups were measured.Results: GLS and AGS levels in CHD group were significantly lower than those in control group whereas GCS and GRS levels were not significantly different from those in control group, and peripheral blood Notch1, Hes1, NF-κB and PKC expression intensity as well as serum sTWEAK, FGF23, TGF-β1, GDF15, sSema4D, CaN, MMP14, PINP and ICTP contents were significantly higher than those of control group;GLS and AGS levels in CHD group were negatively correlated with peripheral blood Notch1, Hes1, NF-κB and PKC expression intensity as well as serum sTWEAK, FGF23, TGF-β1, GDF15, sSema4D, CaN, MMP14, PINP and ICTP contents.Conclusions:The changes of three-dimensional speckle tracking parameters GLS and AGS in patients with coronary heart disease are closely related to the changes in signal pathway function, cytokine secretion and collagen metabolism during left ventricular remodeling.
文摘The authoros specialize in the field of optunization and automatic programme oftrain working graph. In this peper, at frist, a mixed 0-1 integer progranimingmodel about this problem for duuble-track lines is set up, then the principle andProcess of selution are stated, with an application exaiiiple put forward.
基金Supported by National Natural Science Foundation of China,No.82070638 and No.81770621and JSPS KAKENHI,No.JP18H02866.
文摘With the continuous development of digital medicine,minimally invasive precision and safety have become the primary development trends in hepatobiliary surgery.Due to the specificity and complexity of hepatobiliary surgery,traditional preoperative imaging techniques such as computed tomography and magnetic resonance imaging cannot meet the need for identification of fine anatomical regions.Imaging-based three-dimensional(3D)reconstruction,virtual simulation of surgery and 3D printing optimize the surgical plan through preoperative assessment,improving the controllability and safety of intraoperative operations,and in difficult-to-reach areas of the posterior and superior liver,assistive robots reproduce the surgeon’s natural movements with stable cameras,reducing natural vibrations.Electromagnetic navigation in abdominal surgery solves the problem of conventional surgery still relying on direct visual observation or preoperative image assessment.We summarize and compare these recent trends in digital medical solutions for the future development and refinement of digital medicine in hepatobiliary surgery.
基金funded by the general project of National Natural Science Foundation of China(No.41774072).
文摘A magnitude 5.5 earthquakes occurred in Eryuan County,Dali Bai Autonomous Prefecture,Yunnan Province,China,on March 3.And a magnitude 5.0 earthquake occurred in the same place on April 17,2013,i.e.,45 days later.Then,on May 21,2021,multiple earthquakes,one with magnitude 6.4 and several at 5.0 or above,occurred in Yangbi County,Dali Bai Autonomous Prefecture,Yunnan Province,China.All of these occurred in the Weixi-QiaohouWeishan fault zone.In this study,1,874 seismic events in Yangbi and Eryuan counties were identified by automatic micro-seismic identification technology and the first arrivals were picked up manually.Following this,a total of 11,968 direct P-wave absolute arrivals and 73,987 high-quality Pwave relative arrivals were collected for joint inversion via the double difference tomography method.This was done to obtain the regional three-dimensional fine crustal P-wave velocity structure.The results show that the travel time residuals before and after inversion decreased from the initial–0.1–0.1 s to–0.06–0.06 s.The upper crust in the study area,which exhibited a low-velocity anomaly,corresponded to the basin region;this indicated that the low-velocity anomaly in the shallow part of the study area was affected by the basin.Results also showed some correlation between the distribution of the earthquakes and velocity structure,as there was a lowvelocity body Lv1 with a wide distribution at depths ranging from 15–20 km in the Yangbi and Eryuan earthquake regions.In addition,earthquakes occurred predominantly in the highlow velocity abnormal transition zone.The low-velocity body in the middle and lower crust may be prone to concentrating upper crustal stress,thus leading to the occurrence of earthquakes.
基金co-supported by the National Key Research and Development Program of China(Grant No.2019YFC1509204)the National Nonprofit Fundamental Research Grant of China,Institute of Geology,China Earthquake Administration(Grant No.IGCEA2005 and No.IGCEA2014)the National Science Foundation of China(Grant No.41631073)
文摘The 2016 MW7.8 Kaikoura earthquake struck the northern part of south Island,New Zealand,within the active and complex Australia-Pacific plate boundary system.Firstly,we used the InSAR method to obtain coseismic LOS deformation fields based on SAR images and applied offset tracking methods to obtain offset measurements based on optical satellite images.The maximum displacement of about 6 m is detected in the direction away from the satellite on the south-west side and also towards the satellite on the north-east side.The 3D deformation field is then resolved by the combination of these measurements with a least-square solve method,and comparisons with 3 components of GPS stations show good consistency.Despite complex features demonstrated in the 3D deformation field,there are still clear spatial correlations between surface deformation and faults distribution.It reveals that more than ten faults were ruptured during the earthquake,including some faults were previously understudies for their tectonic activities.The maximum horizontal deformation of about 10 m occurs along the Kekerengu fault with the vertical deformation up to 2 m.The 3D deformation shows that the mainshock is a multisegments faulting with a rupture process of strike-slip,compression,transpressional rupture and strike-slip in space along the NE direction.
基金supported by the National Key Research and Development Program of China(No.2018YFB1005002)the National Natural Science Foundation of China(No.61727808)the National Research Foundation of Singapore(No.NRF-CRP11-2012-01)
文摘We proposed a three-dimensional (3D) image authentication method using binarized phase images in double random phase integral imaging (Ini). Two-dimensional (2D) element images obtained from Ini are encoded using a double random phase encryption (DRPE) algorithm. Only part of the phase information is used in the proposed method rather than using all of the amplitude and phase information, which can make the final data sparse and beneficial to data compression, storage, and transmission. Experimental results verified the method and successfully proved the developed 3D authentication process using a nonlinear cross correlation method.
基金supported by the National Natural Science Foundation of China(51467013)
文摘Satisfactory results cannot be obtained when three-dimensional (3D) targets with complex maneuvering characteristics are tracked by the commonly used two-dimensional coordinated turn (2DCT) model. To address the problem of 3D target tracking with strong maneuverability, on the basis of the modified three-dimensional variable turn (3DVT) model, an adaptive tracking algorithm is proposed by combining with the cubature Kalman filter (CKF) in this paper. Through ideology of real-time identification, the parameters of the model are changed to adjust the state transition matrix and the state noise covariance matrix. Therefore, states of the target are matched in real-time to achieve the purpose of adaptive tracking. Finally, four simulations are analyzed in different settings by the Monte Carlo method. All results show that the proposed algorithm can update parameters of the model and identify motion characteristics in real-time when targets tracking also has a better tracking accuracy.
基金Supported by the National High Technology Research and Development Program of China(863 Program)(2011AA1569)
文摘A new tracking algorithm is proposed aiming at the tracking problem in low bit signal-to- noise ratio (i. e. , Eb/N0 ) scenarios, in which the bit clock regenerated by bit synchronization loop decides loop update moment. The double frequency processing and non-coherent accumulation tech- nologies are applied to eliminate the impact of data polarity inversion, and then long time accumula- tion improves the input signal-to-noise ratio of discriminator. The frequency locked loop and phase locked loop constitute a carrier loop in parallel, which can meet the high dynamic demands. The ef- fectiveness of this algorithm has been corroborated by theoretical analysis, simulation and measure- ments, and the new tracking algorithm has been used in an aerospace engineering project successfully.